_ _ _ _
60 - 3c.2 pm k
UNITED STATES g-g j
NUCLEAR REGULATORY COMMISSION Y
WASHINGTON. D.C. 30666 6 1
'44.....,&
(ktober 7,1997
~
Mr. Roy A. Anderson Senior Vice President. Nuclear Operations Florida Power Corporation ATTN: Manager. Nuclear Licensing Crystal River Energy Complex (SA2A) 15760 W Power Line Street Crystal River. Florida 34428 6708
SUBJECT:
CRYSTAL RIVER UNIT 3 - REQUEST FOR ADDITIONAL INFORMATION RELATED TO PROPOSED LICENSE AMENDMENT FOR LOW-TEMPERATURE OVERPRESSURE PROTECTION TECHNICAL SPECIFICATION (TAC NO. M99277)
Dear Mr. Anderson:
This letter is a follow up to your response to our request for additional information (RAl) relating to your proposed license amendment for providing low-temperature overpressure (120P) technical specification (TS) features.
1.
By letter dated August 12. 1997 and subsequent telephone conversations with your staff, we requested that the LTOP limits / values listed in the proposed TS be adjusted for instrument uncertainties.
By letter dated September 5, 1997. you provided a response to our request.
You indicated that the applicable instrument uncertainties will be accounted for in the operating procedures rather than in the TS.
You stated that this would allow revisions to setpoints in procedures due to any instrument modifications and that your position is consistent with other setpoints in the CR3 TS. We do not concur with your position. We have determined that the values for the power operated relief valve (PORV) lift setpoint, pressurizer level and LTOP enable temperature values specified in the TS should be consistent with the methodology described in the TS Bases 3.3.1. (see page B 3.3-10) for the Reactor Protection
'g System and should be conservatively adjusted for instrument uncertainties. Accordingly, please submit a revised license amendment request.
I 2.
We also requested, in our August 12. 1997 RAI. that the temperature difference between the reactor coolant and the vessel metal at a distance one-fourth of the vessel wall thickness from the inside surface (i.e.
quarter t location) should be accounted into the determination of the LTOP enable temperature as is stated in the ASME Code Case N-514.
Your September 5.1997 letter indicated that your LTOP analysis is based 971022o378 971007
- 88R"
^
ll l.l! I.I:l 1:l.l !I.I!I.I ll 3 p pp gy r
l 2 m.a
-(
R. Anderson 2
metal temperature to be equal to the water temperature.
This is not consistent with the ASME Code Case N-514 and the NRC Branch Technical Position 5.2.2.
Therefore, please account for the quarter-t temperature difference.
3)
Please describe the operator actions to terminate an LTOP event within 10 minutes.
We request your response as expeditiously as possible.
If you have any questions, please write or call me at (301) 415-1471.
Sincerely.
ORIGINAL SIGNID BY:
L. Raghavan. Sr. Project Manager Project Directorate 11-3 Division of Reactor Projects - I/11 Office of Nuclear Reactor Regulation Dc:ket No. 50-302 cc:
See next page Distribution Docket File PUBLIC CR-3 r/f B. Boger J. Zwolinski OGC ACRS C. Liang T. Collins B.
Beckner J. Jaudon, Region II J.
Wermiel DOCUMENT NAME: G:\\ CRYSTAL \\99277.rai Tu receive a copy of this document. Indicate in the boa: "C" = Copy w:thout attar.hment> enclosure
'E' = Copy with attechmentlenclosure
- N' = No copy OFFICE PDll 3/PM l l PDil 3/LA l l D TSB l ) PDil 3/D
_)
lE SRXB l
HICB l
NAME LRaghavan W BClayt on MO W.
Beckner H.-
FHebdon N T.
Collins &
JWermiel %
DATE 10/ ') /97 10/71 /97 10/ /97 10/ ] /97 10/ /97 10/ /97
/
OFFICIAL RECORD COPY
f R. Anderson 2
on steady state or isothermal conditions and considered the quarter-t metal temperature to be equal to the water temperature. This is not consistent with the ASME Code Case N-514 and the NRC Branch Technical Position 5.2.2.
Therefore, please account for the quarter-t temperature difference due to temperature gradient across the reactor vessel wall.
3)
Please describe the operator actions to terminate an LTOP event within 10 minutes.
We request your response as expeditiously as possible.
If you have any questions, please write or call me at (301) 4151471.
Sincerely.
A.(
L. Raghavan. Sr. Project Manager Project Directorate 11-3 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation Docket No. 50-302 cc:
See next page
t w
1 Mr. Roy A. Anderson CRYSTAL RIVER UNIT NO. 3 Florida Power Corporation ec:
Mr. R. Alexander Glenn Corporate Counsel Mr. Robert E. Grazio, Director Florida Power Corporation Nuclear Regulatory Affairs (SA2A)
MAC-A5A Florida Power Corporation P.O. Box 14042 Crystal River Energy Complex St. Petersburg, Florida 33733-4042 15760 W. Power Line Street Crystal River, Florida 34428-6708 Mr. Charles Pardee, Director Nuclear Plant Operations (NA2C)-
Senior Resident inspector Florida Power Corporation Crystal River Unit 3 Crystal River Energy Complex U.S. Nuclear Regulatory Commission 15760 W. Power Line Street 6745 N. Tallahassee Road Crystal River, Florida 34428-6708 Crystal River, Florida 34428 Mr. Bruce J. Hickle, Director Mr. John P. Cowan Director, Restart (NA20)
Vice President, Nuclear Production Florida Power Corporation (NA2E)
Crystal River Energy Complex Florida Power Corporation 15760 W. Power Line Street Crystal River Energy Complex Crystal River, Florida 34428-6708 15760 W. Power Line Street Crystal River, Florida 34428-6708 Mr. Robert B. Borsum B&W Nuclear Technologies Mr. James S. Baumstark 1700 Rockville Pike, Suite 525 Director, Quality Programs (SA2C)
Rockville, Maryland 20852 Florida Power Corporation Crystal River Energy Complex Mr. Bill Passetti 15760 W. Power Line Stree.t Office of Radiation Control Crystal River, Florida 34428-6708 Department of Health and Rehabilitative Services Regional Administrator, Region 11 1317 Winewood Blvd.
U.S. Nuclear Regulatory Commission Tallahassee, Florida 32399-0700 61 Forsyth Street, SW., Suite 23T85 Atlanta, GA 30303-3415 Attorney' General Department of Legal Affairs Mr. Kerry Landis The Capitol U.S. Nuclear Regulatory Cominission Tallahassee, Florida 32304 61 Forsyth Street. SW., Suite 23T85 Atlanta, GA 30303-3415 Mr. Joe Myers, Director Division of Emergency Preparedness Department of Community Affairs 2740 Centerview Drive Tallahassee, Florida 32399-2100 Chairman Board of County Commissionors Citrus CotJnty 110 North Apopka Avenue Iverness, Florida 34450-4245