ML20211F638

From kanterella
Jump to navigation Jump to search
Forwards Resident Safety Insp Rept 50-353/86-12 on 860804-0928 & Notice of Violation
ML20211F638
Person / Time
Site: Limerick 
Issue date: 10/22/1986
From: Gallo R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Kemper J
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
Shared Package
ML20211F642 List:
References
NUDOCS 8610310219
Download: ML20211F638 (2)


See also: IR 05000353/1986012

Text

,

.

e

'

22 0CT 1986

Docket No. 50-353

l

Philadelphia Electric Company

l

ATTN: Mr. John S. Kemper

Vice President

Engineering and Research

2301 Market Street

Philadelphia, PA

19101

Gentlemen:

Subject:

Inspection Report 50-353/86-12

This refers to the routine resident safety inspection by Mr. R. A. Gramm on

-

August 4 - September 28, 1986 at the Limerick Generating Station, Unit 2,

Limerick, Pennsylvania of activities authorized by NRC License No. CPPR-107

and to the discussions held by Mr. Gramm with Mr. J. M. Corcoran and other

members of your staff at the conclusion of the inspection,

j

Examinations of as-built pipe supports identified one instance where the

installed support configuration was not in accordance with the applicable

.

engineering drawing. This example of inadequate inspection by field

engineering and quality control has been cited in the enclosed Appendix A

Notice of Violation.

Review of long-term maintenance records identified that the diesel generator

Woodward governors have not been stored in accordance with the vendor

'

instructions which require lubricating oil to be maintained in the governor.

This instance of non-adherence to vendor storage requirements has been cited

in the enclosed Appendix A, Notice of Violation. A response to this. report is

required by 10 CFR 2.201, please follow the instructions in Appendix A in the

preparation of your response.

The response directed by Appendix A, Notice of Violation, is not subject to

the clearance procedures of the Office of Management and Budget as required by

the Paperwork Reduction Act of 1980, PL 96-511.

Your cooperation is appreciated.

Sincerely,

gjO3gCK05000353

19 861022

b

G

PDR

Robert M. Gallo, Chief

Projects Branch No. 2

Division of Reactor Projects

Enclosures:

1. Appendix A, Notice of Violation

2. NRC Region I Inspection Report 50-353/86-12

0FFICIAL RECORD COPY

IR LIM 86-12 - 0001.0.0

10/21/86A '

'h

.

.

.

22 OCT 1986

Philadelphia Electric Company

2

cc w/ enc 1:

V. S. Boyer, Senior Vice President, Nuclear Power

W. T. Ullrich, Superintendent, Limerick 2 Project

Troy B. Conner, Jr., Esquire (Receives All 2.790 Information)

Eugene J. Bradley, Esquire, Assistant General Counsel

Public Document Room (PDR)

Local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

NRC Resident Inspector

Commonwealth of Pennsylvania

bec:

Region I Docket Room (with concurrences)

Management Assistant, DRMA (w/o enclosures)

P. Eselgroth, Section Chief DRP

State Liaison Officer (SLO)

R

RP

h "f,l'

'pp

$h

-

0FFICIAL RECORD COPY

IR LIM 86-12 - 0001.1.0

10/10/86