_

DISCHARGE MONITORING REPORT I-COMMENTS:

l ni-arnI r w Toledo Edison Company u,,q:o Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak liarbor, Ohio 43449-9760 g

(419) 249-5000 t

(4-161 (17-19) 21800011*DD 001 y g3= 5' N 41' 35'

-l1 rueur unen.

oss

., ic iarin te u u;nn =:

t 258-2i H.'2-2 tit 24 - 25 3 4 26-27 H 2it-29 h 30 - 3 t h asurrna: suuio nu es 816 01 81 11 lu 3 16 0 18 31 1 (IAle a)

My YlJut

22 Lan (12-173

( 3 carri onlylle c.ard onlyt

( t.4 - me. )

(bil 70)

(131-451 144 S]I (54-61) 162-6) # 38 - 4 '. I 14e, 51)

I '.4 *. l i (62 e,1, i Pa t.1423 Y ggggy l9 ti u$.;n; l9til mman wue.a:

mxran mns N

mnasa mxnim xa w.a mns 00011 8e 5m2' 63 72 76

.p 1/1 CONT Wat er Temperature ocar (IFI'Irt:N 00400 re u n2) 7.4 8.2 pli 0

1/1 GRAB pil es seu r S. ll.

o voiria, 6.0 9.0 50050 im m2) 1h 24 0.60 2.35

'8.00 Mc0 i Conduit Flow n.wur G 24)lrlt N 50064

"'"'"2' Free Available O.0 0.0 0.0 mg/l 0

1/1 GRAB n aur Chlorine o va >< T ii n 0.5 0.2 m r vensi 11INIT O toITI' t' 8610230179 861016 u m arr PDR R

ADOCK 05000346

" '" n PDR

'"0""

1439 enD J :1 izi.:

Pf J ' WrTm U~..e i wr Irat. imurr.t i i is Tiid 7 'nT~TiTi3 tZiE -

.i r. 4,,:,a c :, ;E.T.Mr.; ! ~ T

_l,. T' f

ca ra4a<.f.a r>u s ser i r a,. s ts. e - t r..

6. s r.

IIIIAMS,.IR.,

JOE Sit VICE PRES / NUCLEAR 81 6 Gi 9 111

  • t=(ed e aad be f a d wi * ** 4 =' t * *'

i Miin nn0.i~il-

.titz inni r

]

e ter u

inu an m mr

' ' . 8 a 2c c ed ' < -

i o i' i n c.v ua.r I

ou a: 1

.e-

DISCHARGE MONITORING REPORT I._

COMMENTS:

v. '-*rrnr twe Toletlo Eillson Company l

Davis-Besse Nuclear Power Station 2,y,s 5501 North State Route 2 Oak liarbor, Ohio 43449-9760 L

(419) 249-5000 J

t vi (4-10 (17-19p 21B000ll*DD 002 W 83* 5' N 41 ' 35 '

+

.r it.lftIT taMu Je Das sie (A rlit t a.

kN ;1114 9.

(20-21 tf 22-21H 24 1$ 3 (26-27 H 28 -29 k l0 -Ill l

IGR4rrIW I'UtItX)

IMM R l6 OlR 0] ]

lu 8: 6 @

311 i

(IAH Pts tar grAst

E tav

( B2-III t I c arti only)I4 c.m1 <mly) t e.4 we,)

t e.H - 70 )

t 62 -% g f a 181 - 4 '. e

  • "U i M-45)

(46 51)

(54 6ti

'"D" v 4..

it;

.4 s ta,,1 : ' 3 \\808T i

rm u, lstil vuoan mein a., ri. a imis 9 ti

,y [,s,.;

miuwn nim r w rn.*

iru rs m:

00400 p,2, ern2)

PH 8.0 8.4 pil 0

1/7 GRAB n ma r S.U.

l

~'

.t es.i rr. e, 6.0 9.0

^

00530 Total nonfilterable 10.0 36.5 2I.9 mg/1 0

1/7 CRAB n mir Res iilue n iairn. ra 30 50050

'41"m2) 0.051

'O.103 0.526 Contluit Flow MGD

~ ~~ ~

n ieu r

.in,a n ta 00550 se p un2' O.4 3.2 1.3 0

011 anti Grease mg/1 n mir o ra,t ii. e4 20 15 1/] _

CRAB HI I' 4rn 1) ti ltil r O t4>Illt #4 Hij' arnD liEMIT dvaitT! -

i4 J' 4rn D l'.ti!!

Jr2!!!r; 14 3' 4r!1 D

r... g c r.n 1 s.

MJ M

.v n. i e tx ts A1. amurrx < e i i. u ri rit r4 ilt >n tiim t e n.

t a t. i, rh.i t I a. ; u... n.. ts. ri,....,-w...,

uu ta<n t ut th< s sen., r a,a tha t te o.. te r. 5

'lI I IMtS,.I R.,

.IO E SR, VICE P'tFS/NUCl_ EAR 816 01 9 Ill i

tadid ir ud 6*(' < 4 $u 6

  • a 4..me r.. " * ' ' m
  • a I

D I K;T Mt rillE (int 4) 3Al

    • I*'IE*

'"'I C u M =

a aarnt Y Tutir u e anru.

(R!t T h e r M M25 rarl + 1

DISCHARGE MONITORING REPORT p

COMMENTS:

u,mrnz tw Toledo Edison Company u..g.s Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak liarbor, Ohio 43449-9760 L

(419) 249-5000 J

s, gi 14-161

" ' 19 )

3 21B000ll*DD 003 y g3. S' N 41

  • 35 '

1 FTfMIT toDittJ O1s sir' 1AT!11 E t IAD411111*:

( 20- 21 lt 22-21 t( 14 - 2%

(26-27 K 28 -29 k 30 -Il l d

OlR Ol ]

TT) 8l 6 (j F 3 l]

SERWT!?O fYJtito IMM nu ni tar vru

D tm

( 12 - 17 D (I c u11 onlyt (4 cel m1yl t

  • I * *> p f ul - 7t H 118-45) l46 5))

(54 61)

( 62 -e. ) I19-4 6 4 4..

.h li (f 2 hli

'"'"I8 i nwe n3

?Jgg gj:

a hT3l

  • tINI*t M L1JW 2

'9Jt Dt N tti!IS

'U f 4 D I N

.h !!9 et bi lV. J I R4 II'i W l.1 Nag,:,gs D I E.

50050 Pt3' am3 s

0. m
0. m m

1/1 24 Conduit Flow sum t (Itai!TI to

      • 2' To t.n l N t e rab l e 17.5 17.5 17.5 mg/l 1/30 GRAB Res i clue nma r o sa a t ri. 34 ILJ8 4mD it Wi!T (1 st st r!. e4 PI 15 4mI) 11&MIT 0 34 1T1: la Rt )e 4rt1D 11 }fil r

~

LIROITli te WIP wi1D 816CtIT t t ta al Tt' te Hi le 4m p I' ?t!

  • PI P FT13*

g,

-,g :

ar: 3.

s.1 4 i s t:a. inu. t.vurrr.1. e i ias Tsin < 4 m in co n tatt i m t4 4., e xa r r u. i s.... u.. ri, r...., m,,.

,, FA g

e

.cnfdened 4e th43 tesvtf.en.1 (kJ( f.

f..-

(g)(.i 1 i 1. I A!!S,.l R.,

.lO E Ek VIf'E PRES / NUCLEAR 816 Of9 11 1

  • *a ~ted# aad t>'f a d

$'* * **'4.'*'t.

sbau niet a nuin:n t

.v rii i 7r e i.e.T u

T: n1 (tu u tav a=ri. dad deca u '<-

<n saa im umasu i nr swa; 1 v 1

DISCHARGE MONITORING REPORT I.

COMMENTS:

l m ; nt twe.

Toledo I:411 son Company Davis-liesse Nuclear Power Station 5501 North State Route 2 Oak liarbor. Ohio 43449-9760 l_

(419) 249-5000 J

e_.

(4-16e i17 IH ol t 21B000ll*DD 601 w 83* 5' N 41

  • 35' 7'

It set 1 T *a H14 B i.1,

s i, IA T I Ti t i.

[174;111 M I M - 21 )i 22-2118 J4 - /M

( 26 -2 7 M 29 -29 h 30-ll t

  1. erernts; sus'n san 10 81 6 08 311 e tu o

ia sua

n tar t12-17) 11 CMY1 Ortlyll4 CMd < Wily!

404 '%)

IhN ' MI

< m au n.sn

'J"'"l

isi. n i 42 -~ i s is-4 a u...i.'"'"'^'o4

.ii a se.. i1 rwn er

[9 b Arr$.. sis l95 u.m n v.wa winr4 unis ut4mn w nta a i /. 2 unn 00083 pun-n n Severit 3

g i

1/1 GRAB Color Units su 4 r I

tYW3 3I TI N l

01310 O

O O

Severit 1/1 CRAB Odor smu r Units

<us >s n us 01350

    • I"m2>

1 2

1 Severit 1/1 GRAB Turbidity

"'"rr Units sl ati!T I' N 50050 0.027 0.027 0.027 MCD I/I 24 Conduit Flow n.*4 r ana n.n 00530 kn *mn 2.7 24.0 13.3 0

2/30 CRAB Total Nonfilterable-n,,,,,

mg/l Residue a vaari n 45 30 "8 " *m D 00310 3

11 7

mg/l 0

2/30 GRAB BOD (5-day) 8 " "37

.uaa n n 45 30 Pf D WI1D 11 m: r

' 5 III ;

sai enn

'I 1' ',,

]

,1 i i.it. t: nt. in nnr.t 411 1~ -'

niu >* na.otilu ta tt i o r i, tha t I a-i.-..n..r.r.

i o.

a. r44us 4.

n< s it,vi r.m; th a r.

ro.

+.sr.5 II I IVtS, JR.,

JOE

.SR.VICE PRES /11UC1 EAR 81 6 0l9 111

    • t ac*te.tv a=J bet 4 m 4.

.e

. n s..r a : 4 i, i; u

.a.

ei rifu num o tar

  • * * " ' '. J.'d 'c oo'

.r eucr au

'n Icts in um i

> us2rr swa: 14 _

1

DISCHARGE MONITORING REPORT COMMENTS:

I l

eueurnz iwe Toledo Edison Company Davis-Besse Nuclear Power Station m

5501 North State Route 2 Oak liarbor, Ohio 43449-9760 (419) 249-5000 L

J egi (4-166 (17-191 of 21B000ll*DD n02 W 83* 5' N 41* 35' T

staur ams ois src tarinrt unc:nu

(20-21H 2 2-21)(24-25 3 426-27 H 24-29h 30-118 suurrac rauco rum 816 018 01 1 10 81 6 (E

3 11 (IAJt ro tar tEAJt

23 QAx (32-37)

(3 card cely)(4 card only)

( 64 -% I (68-708 I

U (18-45)

46-531 154-61) 862 + 3 838-4!n 146-51s
  1. 54.*t)

(62-61 SApatz l95l l9 cl m u.ysis N

aunutm muuz mxem u4 Ts

.unnta msnm x.uu r turts ll 00530 PDuMD 0.8 15.0 5.3 mg/l 0 2 30 CRAB Total Nonfilterable Re3idue m orrrcN 100 30 ll 00550 0.0 0.9 0.5 0 2/30 CRAB Total oil & grease Smur "8N cuorito.

20 15

'e'mn 0.089 0.089 0.089 ll

( l 1/1 50050 MCD 24 Conduit Flow "7

G20!TI( N EtiftIT LTROITICN It1P V!TD f1 teuT aw0 tTICH ll ll Il ietti (TrLIItse fGP 4'T1D mm Jr !!I.

R13' 'f'TTD l:=c -

~

Any w

,.*ccrm. murr.1 ui t u Trns or x a m a cart

.<1r ;., cuc J,

wa ai. rs, t.

...u..,

.c Ci'*LLued s e the tap.'t r JNJ ik{ (.

f,g bg 3 (. $

.IIIMt3, JR.,

JOE SR.VICE PRES / NUCLEAR 816 019 11 1

  • a ca s edu ud bet a 4 e. 4u w r..

o r.t.

srt2.uwt rw od:enLr_n/,,.nr c,

1, m

.e

,m

..,u u. - _ m.

m,_,, _

ruzl D

DISCHARGE MONITORING REPORT r_

COMMENTS:

Toledo EdIsen Company

-I o intnz

  • arc

,,. m Davis-Besse Nuclear Power Station 5501 North State Route 2 Oak liarbor, 01: 1 0 43449-9760 (419) 249-5000 og (4-163 f17-193

>I' 21800011*DD 801 W 83* 5' N 41

  • 35 '

7' T1)e11T *A Mu R ties sic 1AT! Tit a_

haa.i tt l e.

( 20 - 21 H 2 2-2 lis 24 - P.3 (26-27)t 20 -29 5. 30 11)

M 018 01 1 10 86 311 e scitu;ru m s w ei

.iu rt>

iar axe

.m tai i 12 17) 6I candemly 14 cMit wilyI t 8

  • e.1 l' '4

!")

I14-853 e4% 13)

(54 61) 16 * -, g Il9-4'l ft.

.se D e. li

& 2

e. l :

FNg tJ

  • wve m.
  • ti?al's N E1Mv 2 SJL DtP*

t *Ji l3 pd

'tif4 tFS H

'W. !!9 't

.I'

.J I "* l l-*

91.1 lw s.l. :.1:;

r. : '

00011

    • '"D F

70 76 79 W.it er Temperature su e.i t 1/1 CONT (1886!T1 #1 j

R13' $1*T1 D 81]et1 T 4138 8 l ria 74 i

54JWr71D E

61 Ril T 41 et 1TI* es li l' S"Tlb E

It sti!T 0 t2'111 t4 M1 P 1rI1D E

fiFNiT

  • 143:1 TI 94 p} Iv IFTYD E

111f1!T i.t t0! Tl' e4 se v ernD I*

!t:!

mr ri

  • N11' 4rr1D g,..;-

v2t\\ : ~e.

~

r, 6 M

s.:n

.4 satraa m.exn vrr.1 centiis rina 4 11e un tiu (Att

c r. g gu,a r
a. s im o. n... g, tu..4..,..

.. ta<nei <n tk<s

,e.

,e

.a that t raw teu. 5 b6 0; 9 tl

1 I 1. I A*ts, J R.,

.IOE Si( VICE PRES /NUCIIAR l

i

.., e r,a y. a e,.. < 4,,,,,,. s. m, r...,..,.,.

sigsita p i g,n, i,.., xi. 9 c i.

-~

s 1.or m

ra nJ.

! itx4 se

Ae

' *r ' ' k. *8 d e r" -

<ei stu ue uma nD A3Mr.

'cu l.c 1

TOLEDO

% EDISON EOISON PLAZA 303 MACISON AVENUE Tm.EDO. OHIO 43652 RR 2 P-12-86-08 E 2.40.1.1.2 CA86-0527L September 12, 1986 U.S. EPA - Region V (SWQP)

Water Quality Branch 230 S. Dearborn Strect Chicago, Illinois 60604 ATTENTION:

Kenneth Fenner, Chief

Dear Mr. Fenner:

Attached is a copy of the August, 1986, Ohio EPA Discharge Monitoring Report for Davis-Besse Nuclear Power Station, Permit Number 2IB00011*DD.

Power was lost to the beach sampling station (outfall 001) on August 21, 1986, due to the failure of a transformer.

A temporary generator was installed to reinstate power to the sampling station.

Yours truly.

I.. F. Storz <I Plant Manager, Davis-Besse Davis-Besse Nuclear Power Station (419) 249-5000. Ext. 7589 LFS/PJM/jjh Attachments cc:

P. Byron, U.S. NRC Resident Inspector A. F. Cephart J. L. Scott-Wasilk J. F. Stolz, NRC J. E. Sullivan bec: