16 00T 1986 Docket No.
50-410 Niagara Mohawk Power Corporation ATTN: Mr. C. V. Mangan Senior Vice President
'300 Erie Boulevard, West Syracuse, New York 13202 Gentlemen:
Subject:
Concerns About Nine Mile Point Unit 2 Control Room Environmental Envelope On October 8,1986 our resident inspectors received concerns from Mr. J.
Richard Jones about the environmental envelope for the control room of Nine Mile Point Unit 2 and the ventilation systems designed to maintain the temperatures and pressures in the control room within specified limits.
These concerns had been documented in a letter from Mr. Jones to Mr. John Conway dated August 1, 1986, with copies to other plant personnel. Mr. Jones stated that he had been unable-to get satisfactory resolution of his concerns from his supervision and did not feel that the Quality First Program could properly address them.
As you already have the details of Mr. Jones' concerns, we request that you provide us with a report of the results of your evaluation of this matter.
Further, we request that you evaluate why this matter was not resolved by your program for addressing worker concerns and report these findings also. To preclude any impact on the issuance of the operating license, we request that your report be expedited to the maximum extent practical.
If you have any further questions on this matter, please contact either the NRC resident inspectors or Mr. James Linville of this office at 215-337-5122.
ypsina.1. Signed By:
Robert M. Gallo, Chief Projects Branch No. 2 Division of Reactor Projects 8610210318 861016 ADOCK0500gO PDR A
0FFICIAL RECORD COPY 322 MEYERS 10/10/86 - 0001.0.0 l-10/16/86 ho1
Niagra Mohawk Power 2
Corporation 16 0CT 1986 cc:
Connor & Wetterhahn John W. Keib, Esquire J. A. Perry, Vice President, Quality Assurance W. Hansen, Manager of Quality Assurance D. Quamme, NMP-2 Project Director C. Beckham, NMPC QA Manager T. J. Perkins, General Superintendent R. B. Abbott, Station Superintendent Department of Public Service, State of New York Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector State of New York bec:
Region I Docket Room (with concurrences)
Management Assistant, DRMA (w/o encl)
DRP Section Chief Region I SLO Robert J. Bores, DRSS Allegation File RI-86-A-121 M. Haughey, NRR W. Cook RI:DRP RI:DRP Meyer/rbl Linville Ghllo 10/( /86 10/b/6 10/.b/86 0FFICIAL RECORD COPY 322 MEYERS 10/10/86 - 0002.0.0 10/14/86
-