Fct'ruary 11, 1987 Docket Nos. STN'50-454, DISTRIBUTION 50-455, seemet: Fila._ NRC PDR 50-456, PDf3 Rdg.
Local PDR and STN 50-457 T. Novak OGC E. Jordsn B. Grimes Mr. D. L. Farrar J. Partlow N. Thompson Director of Nuclear Licensing L. Olshan C. Vogan Comonwealth Edison Company ACRS(10)
Post Office Box 767 Chicago, Illinois 60690
Dear Mr. Farrar:
SUBJECT:
RECONSTITUTION OF A FUEL ASSEMBLY - REQUEST FOR ADDITIONAL INFORMATION By letter dated January 6,1987, you requested an 3mendment to the Technical Specifications that would allow the reconstitution of a fuel assembly on Byron /
Braidwood. Enclosed is a request for additional information that we need to complete our review.
The reporting and/or recording requirements of this letter affect fewer than ten respondents; therefore, OMB clearance is not required under PL 96-511.
Sincerely, Leonard N. 01shan, Project Manager Project Directorate #3 Division of PWR Licensing-A
Enclosure:
As stated cc:
See next page PD#3 PDf39 PD#3 CVogan #
JStevhhs L01shan 2/s /87 2/II/87 2/H/87 o
l l
2180077 870211 ADOCK 05000454 p
PDR h
f Mr. Dennis L. Farrar Commonwealth Edison Company Byron /Braidwood k
cc:
Mr. William Kortier Dr. Bruce von Zellen Atomic Power Distribution Department of Biological Sciences Westinghouse Electric Corporation Northern Illinois University Post Office Box 355 DeKalb, Illinois 61107 Pittsburgh, Pennsylvania 15230 t
Joseph Gallo Esq.
U. S. huclear Regulatory Commission Isham, Lincoln & Beale Byron / Resident Inspectors Office 1150 Connecticut Ave., N.W.
4448 German Church Road Suite 1100 Byron, Illinois 61010 Washington, D. C. 20036 Ms. Diane Chavez C. Allen Bock, Esquire 528 Gregory Street Post Office Box 342 Rockford, Illinois 61108
)
Urbana, Illinois 61801
[
Mrs. Phillip B. Johnson i
Thomas J. Gordon, Esquire 1907 Stratford Lane
{_
Waaler, Evans A Gordon Rockford, Illinois 61107 2503 S. Neil I
Champaign, Illinois 61820 Douglass Cassel, Esq.
l:
109 N. Dearborn Street
(
L Ms. Bridget Little Rorem Suite 1300 Appleseed Coordinator Chicago, Illinois 60602 E
117 North Linden Street I
Essex, Illinois 60935 Ps. Pat Morrison i
5568 Thunderidge Drive l
Mr. Edward R. Crass Rockford, Illinois 61107
[
Nuclear Safeguards and Licensing t
Division David C. Thomas, Esq.
j Sargent A Lundy Engineers 77 S. Wacker Drive 6
55 East Monroe Street Chicago, Illinois 60601 Chicaco, Illinois 60603 Elena Z. Kezelis, Esq.
U. S. Nuclear Regulatory Comission Isham, Lincoln A 9eale Resident Inspectors Office Three First National Plaza RR#1, Box 79 Suite 5200 Braceville, Illinois 60407 Chicago, Illinois 60602 s
l 3
f 4
a u
F
~
h k
L
<- q-
=
I i
8 7 Byron /Braidwood cc:
Regional Administrator U. S. NPC, Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Mr. Charles D. Jones, Director Illinois Emergency Services and Disaster Agency 110 East Adams Street Springfield, Illinois 62706 Ms. Lorraine Creek Rt. 1, Box 182 Manteno, Illinois 60950 Mr. Michael C. Parker, Chief Division of Engineering Illinois Department of Nuclear Safety 1035 Outer Park Drive Springfield, Illinois 6?704 Michael Miller Isham, Lincoln & Beale One First National Plaza 42nd Floor Chicago, Illinois 60603 George L. Edgar Newman & Holtzinger, P.C.
1615 L Street, N.W.
Washington, D.C.
20036 I
l 6-ENCLOSURE
)
RECONSTITUTION OF A FUEL ASSEMBLY REQUEST FOR ADDITIONAL INFORMATION Commonwealth Edison should supply additional information that provides assurance of adequate radiation protection of workers during the reconstitution operation. Specific issues to be addressed include:
1.
The qualifications, authority and reporting level of the radiation protection manager; 2.
Radiation protection planning and preparations, including utilizing and learning from experience at other plants with similar operations; 3.
The' extent of coverage of the operation by trained health physics technicians; 4.
Any special radiation or contamination monitoring equipment that will be utilized; 5.
Estimates of worker doses; including both the maximum doses to individuals and the cumulative dose to the group; and 6.
Provisions for coping with potential accidents and releases.
-