Text

i,,

Commonwealth Ednon Company i.,

140n Opus Place.

Ibwners Gros e, II,(10515 57o1 August 21,1997 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 -

Subject:

Additional Infonnation Pertaining to the Technical Specification Amendment for the Reduction in in Dose Equivalent Iodine Byron Units I and 2 NRC Docket Numbers: 50:454/4M

References:

1)

J. Ilosmer letter to the Nuclear Regulatory Commission dated January 31, 1997 transmitting Technical Specification Amendment Request.

2)

Teleconference dated August 6,1997, between the Commomvealth Edison Company and the Nuclear Regulatory Conunission.

The referenced letter transmitted the Commonwealth Edison Company (Comed) request to amend the Technical Specification for the reactor coolant system Dose Equivalent lodine-131 for Byron Unit 1. Subsequent to that transmit +al teleconferences were held to clarify information pertaining to the dose consumption in the unlikely event of a main steam line break. In the referenced teleconference the Nuclear Regulatory Commission requested the dose calculations for the control room, exclusion area boundary and low population zone. Attached are the exclusion area boundary and low population zone calculations. As a result of your review of the calculations you will conclude that the Loss of Coolant Accident dose consequences bound those for a main steam line break.

As discussed August 21,1997, the final control room calculation will be transmitted August 22, 1997.

Comed is looking forward to meeting with the Staff on August 26th to further discuss these calculations along with any additional issues related to the Technical Specification Amendment.

If you have any questions, please contact this ofTice.

Sincerely,

,4;. e ^^~"

CD Jolm B. llosmer Engineering Vice President Attachment cc:

A. Beach, Regional Administrator - Rill G. Dick, Byron Project Manager - NRR C C 013,i S. Burgess, Senior Resident inspector - Byron lipyRKit Rijl 9708260454 970821 PDR ADOCK 050004544 p

PDR A Unicum comp.my

-