ML20210L645

From kanterella
Jump to navigation Jump to search
Final Deficiency Rept (55(e)-86-02) Re Rejectable Alloy Stainless Products Co ASME III Class 1 Fittings.Initially Reported on 860313.Fittings Scrapped & Unavailable to Evaluate Probable Cause of Failure
ML20210L645
Person / Time
Site: Nine Mile Point 
Issue date: 04/15/1986
From: Mangan C
NIAGARA MOHAWK POWER CORP.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
(55(E)-86-02), (55(E)-86-2), (NMP-0686), (NMP-686), NUDOCS 8605020012
Download: ML20210L645 (2)


Text

y

__/2 Af

' ~ ~

N3tMWe NIAGARA AdOHAWK POWER CORPORAT10N/300 ERIE BOULEVARD WEST, SYRACUSE, N.Y.13202/ TELEPHONE (315) 4741511 April 15, 1986 (NMP2L 0686)

Mr. R. W. Starostecki, Director U.S. Nuclear Regulatory Comission

. Region I Division of Reactor Projects '

631 Park Avenue King of Prussia, PA 19406 Re:

Nine Mile Point - Unit 2 Docket No. 50-410

Dear Mr. Starostecki:

Enclosed is a final report in accordance with 10CFR50.55(e), for the problem concerning rejectable ASME III Class 1 fittings.

This probl em was reported via tele-con to L. Doerfl ein of your staff on March 13,1986 Very truly yours, C. V. Mangan Senior Vice President CVM/GG/cla (1522H) xc: Director of Inspection and Enforcement U.S. Nuclear Regulatory Comission Washington, DC 20555 R. A. Gram, NRC Senior Resident Inspector NMPC Project File kDR3jjjjK05000410.

2 860415 s

PDR l67/1

NIAGARA M0 HAWK POWER CORPORATION NINE MILE POINT - UNIT 2 DOCKET NO. 50-410 Final Report For a Problem Concerning Rejectable ASME III Class 1 Fittings (55(e)-86-02)

Description of the Problem It was determined by Field Quality Control personnel that 22 fittings out of 124 ASME III Class 1 fittings supplied by Alloy Stainless Products Company, exhibited rejectable indications as found by liouid penetrant examination.

The 22 fittings in ouestion did not meet the reouirements of ASME III NB-2546.3 as reoutred by the procurement specification.

The 22 fittings were identified and re.iected prior to use.

The 124 fittings represent all material on site that we have identied as being supplied by Alloy Stainless Products Company.

Analysis of Safety Implications Further investigation of the size and nature of the indications would be necessary to determine the probability of failure of the fittings if installed.

However, the fittings have been scrapped and are not available for evaluation.

Therefore, had the defects gone uncorrected, the safety of operation of the plant may have been adversely affected.

Corrective Action The 22 defective fittings have been scrapped.

4