7
-
.
~
APR 2 i 1986
~
In Reply Refer To:
Docket:
50-382/86-04
Louisiana Power & Light Company
ATTN:
G. W. Muench, Director
Nuclear Operations
317 Baronne Street
P.O. Box 60340
New Orleans, Louisiana 70160
Gentlemen:
This refers to the inspection conducted by Messrs. J. B.-Baird and N. M. Terc
3
during the period February 10-14, 1986, of activities authorized by NRC
' Operating License NPF-38 for the Waterford 3 Steam Electric Station, and to the
discussion of our findings with members of your staff at the conclusion of the
inspection.
Areas examined during the inspection included emergency detection and
classification, protective action decisionmaking, dose calculation and
assessment and emergency program review. Within these areas, the inspection
consisted of selective examination of procedures and representative records,
interviews with personnel, and observations by the inspectors.
These findings
are documented in the enclosed inspection report.
During this inspection,-'it was found that certain of your activities were in
violation of NRC requirements.
Consequently, you are required to respond to
this violation, in writing, in accordance with the provisions of Section 2.201
of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal
Regulations. Your response should be based on the specifics contained in the
Notice of Violation enclosed with this letter.
We are concerned that the violation identified in the Notice of Violation
indicates that effective corrective action was not implemented subsequent to a
similar violation documented in NRC Inspection Report 50-382/85-23.
Therefore,
in response to the current violation you should give particular attention to
the corrective steps which you will take to avoid further violations.
The response directed by this letter ano the tccompanying Notice is not subject
to clearance procedures of the Office of Managament and Budget as required by
the paperwork Reduction Act of 1980, PL 96-511.
RIV: EP&$
EP&S
C:EP&SP
0:0
C: S
C:RPB
'
JBBaird/Jw
NTer
LAYand
rt
GL onstable
JEGagl
do
3/A5/86
tr/8 /
4 / 8 /86
g/ll /86
4 /g /86
//1
,
. . ,
E
8604290125 860421
l
ADOCK O
y2
G
SS%
- T
.
'
'
. .
l
L
Louisiana Power & Light' Company
-2-
.
Should you have any questions concerning this inspection, we will be pleased to
discuss them with you.
-Sincerely,
,edg)nd_MM
s
J. E. Gagliardo, Chief
Reactor Projects Branch
. - Enclosures:
1.
Appendix A - Notice of Violation
2.
Appendix B - NRC Inspection Report
50-382/86-04
e
cc w/ enclosures:
Louisiana Power & Light Company
ATTN:
G. E. Wuller, Onsite
Licensing Coordinator
P. O. Box B
Killona, Louisiana
70066
Louisiana Power & Light Company
- ATTN:
R. P. Barkhurst, Plant Manager
P. O. Box B
Killona, Louisiana
70066
Middle South Services
ATTN:
Mr. R. T. Lally
P. O. Box 61000
New Orleans, Louisiana
70161
Louisiana Power & Light Company
ATTN:
K._W.-Cook, Nuclear Support
and Licensing Manager
142 Delaronde Street
New Orleans, Louisiana
70174
,
Louisiana Radiation Control Program Director
bec to DMB (IE35)
bec distrib. by RIV:
- RPB
- D. Weiss, LFMB (AR-2015)
- Resident Inspector
R. D. Martin, RA
- Section Chief (RPB/C)
DRSP
- R&SPB *
RSB
- MIS SYSTEM
- RSTS Operator
- RIV File
- J. B. Baird
- N. M.-Terc
- L. A. Yandell
R. L. Bangart
- w/766
.