Forwards Tech Spec Surveillance Requirement 4.4.6.2.2 & List of RCS Pressure Isolation Valves W/Description of Measures Performed to Assure Integrity of Valves as Independent Barriers,Per Generic Ltr 87-06
ML20210B129
Person / Time
Site: Callaway Ameren icon.png
Issue date: 04/29/1987
From: Schnell D
UNION ELECTRIC CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
GL-87-06, GL-87-6, ULNRC-1504, NUDOCS 8705050237
Download: ML20210B129 (4)


Text

.

Umon Etscraic s

1901 Gratiot Street. St Louis April 29, 1987 U.S. Nuclear Regulatory Commission ATTN:

Document Control Desk Washington, D.C.

20555 Gentlemen:

ULNRC-150 4 CALLAWAY PLANT DOCKET NO. 50-483 PERIODIC VERIFICATION OF LEAK TIGHT INTEGRITY OF CALLAWAY PLANT PRESSURE ISOLATION VALVES

Reference:

Generic Letter 87-06, dated March 13, 1987 Union Electric received NRC Generic Letter 87-06 in March 1987.

The generic letter requested a list of all pressure isolation valves and a description of the measures performed to assure the integrity of the valves as independent barriers at the reactor coolant pressure boundary.

This submittal provides the requested information.

Callaway Technical Specification Surveillance Requirements 4.4.6.2.2 requires leak rate testing of all pressure isolation valves, and Table 3.4-1 provides a listing of all the reactor coolant system pressure isolation valves.

For your convenience the surveillance requirement is provided as Attachment A to this letter and Table 3.4-1 is provided as Attachment B.

Should additional information be required, please contact us.

Very truly yours, C

Donald F. Schnell DJW/ lad Attachments

$f hY g*gsS28/SIOII 87050 h h [5 83 g6 DR PDR pg

[

/g f[

Ma:!rng Adoress' P O Bow 149. St Louis. MO 63166

. _ ATTAcHHeMT A

~

~

l REVISlay 1

,{.

.t

)

HEACTOR COOLANT SYSTEM s

SURVEILLANCE REQUIREMENTS 4.4.6.2.1 Reactor Coolant System leakages shall be demonstrated to be within each of the above limits by:

Monitoring the containment atmosphere gaseous or particulate a.

radioactivity monitor at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; b.

Monitoring the containment normal sump inventory and discharge at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />; Measurement of the CONTROLLED LEAKAGE from the reactor coolant pump c.

seals when the Reactor Coolant System pressure is 2235 2 20 psig at least once per 31 days. The provisions of Specification 4.0.4 are not applicable for entry into MODE 3.or 4; d.

Performance of a Reactor Coolant System water inventory balarice at least once per 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />; and Monitoring the Reactor Head' Flange Leakoff System at least once per e.

24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

M.4.6.2.2 Each Reactor Coolant System Pressure Isolation Valve specified in

- )

Table 3.4-1 shall be demonstrated OPERABLE by verifying leakage to be within

)

its limit:

a.

At least once per 18 months; b.

Prior to entering MODE 2 whenever the unit has been in COLD SHUTDOWN for 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or more and if leakage testing has not been performed in the previous 9 months; c.

Prior to returning the valve to service following maintenance, repair or replacement work on the valve; and d.

Within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> following valve actuation due to automatic or manual action or flow through the valve except for valves 88PV8702 A/B and EJHV8701 A/S.

The provisinns of Specification 4.0.4 are not applicable for entry into MODE 3 or 4.

I

%. )

CALLAWAY - UNIT 1 3/4 4-20

^

ATTACHt1EMT B

l REvigIOAt i

y.,

TABLE 3.4-1 i

REACTOR COOLANT SYSTEM PRESSURE ISOLATION VALVES l

(

VALVE NUMBER FUNCTION BBV8948 A, B, C, D SI/RHR/Accum Cold Leg Injection BBV8949 A, B, C, D SI/RHR Hot Leg Injection BBV001, 022, 040, 059 BIT Cold Leg Injection BSPV8702 A, B RHR Normal Suction EJV8841 A, B RHR Hot Leg Recirc Ctat 150 EJHV8701 A, B RHR Normal Suction EMV001, 002, 003, 004 SI Hot Leg Inj Ctmt ISO EM8815 BIT Inj'Ctat Isolation EPV010, 020, 030, 040 SI Cold Leg Inj Ctat ISO EPV8818 A, B, C, D RHR Cold Leg Inj Ctat ISO EPV8956 A, B, C. 0 Accum Inj Isolation 6

9 e

t O

8 e

CALLAWAY - UNII 1 3/4 4-21

s I

cc:

Gerald Charnoff, Esq.

Shaw, Pittman, Potts & Trowbridge 2300 N. Street, N.W.

Washing ton, D.C.

20037 Dr. J. O. Cermak CFA, Inc.

4 Professional Drive (Suite 110)

Gaithersburg, MD 20879 1

W. L. Forney Division of Projects and Resident Programs, Chief, Section lA U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, Illinois 60137 Bruce Little Callaway Resident Office U.S. Nuclear Regulatory Commission RRil Steedman, Missouri 65077 Tom Alexion (2)

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Mail Stop 316 7920 Norfolk Avenue Be the sda, MD 20014 i

Manager, Electric Department Missouri Public Service Commission P.O. Box 360 Jefferson City, MO 65102 L

__,