SEP 0 81986 Docket Nos. 50-528 and 50-529 Arizona Nuclear Power Project P. O. Box 52034 Phoenix, Arizona 85t72-2034 Attention:
J. G. llaynes, Vice President Nuclear Production Gentlemen:
This is to acknowledge your letter of August 1, 1986 in which you furnished us with your 1986 Annual Emergency Plan Exercise Objectives. Additionally, this letter is intended to confirm the results of an August 25, 1986 telephone discussion between Ms. Gail M. Temple and Mr. Dennis Yows.
Ilased on our review of your objectives, we concluded that (a) they are too general in nature and do not contain discrete, observable measures of success, (b) there are no objectives directly related to the area of llealth Physics and, (c) the Extent of Play portion had been omitted from the letter.
Ms. Gail M. Temple, of my staff, discussed these three matters with Mr. Dennis Yows, of your staff, during a telephone conversation on August 25, 1986.
During this telephone conversation, Mr. Yows confirmed that the Extent of Play portion had indeed been omitted from the letter.
Ms. Temple and Mr. Yows agreed that since this information would be included in the complete scenario package, which would be sent in the near future, this matter would be addressed as part of our scenario review.
Further, Mr. Yows agreed to develop an exercise objective related to lfcalth Physics and to include the additional objective in the scenario package.
Regarding item (a) above, Ms. Temple and Mr. Yows discussed several ways in which the objectives could be improved.
It is my understanding that Ms.
Temple forwarded some guidance material to Mr. Yows on this subject. During the telephone conversation, Mr. Yows agreed to incorporate the guidance into next year's exercise objectives.
Per< ling resolution of these issties, we find your exercise objectives appropriate, and have no other comments or suggestions.
5
-9 qv 8609150323 060908 PDR ADOCK 05000528 F
PDR jg
,s
.SEP 081986
! 4 i
In addition, FEMA, Region IX stated that they have reviewed your exercise objectives and have no questions at this time.
Sincerely, i
i t.
m Ray F. Fihh, Chief Emergency Preparedness Section cc:
D. Yows, ANPP S. Elkins, FEMA, Region IX bec:
Project Inspector Resident Inspector l
RSB/ Document Control Desk (RIDS)
G. Cook j
B. Faulkenberry J. Martin i
l i
I e
i l
1 i
i.
I' j
Region V
[
//
i l
G}$
Fish 9/d/86 9/d' /86 l
f l
l
)
f
_. _, _.. - _ _. ~,
,o Arizona Nuclear Power Project P.o. Box $2034
- PHOENIX, ARIZONA 85072-2034 August 1, 1986 Mr. John B. Martin, Regional Administrator ANPP-37656-JGH/DGY/93/41 Office of Inspection and Enforcement U.S. Nuclear Re8ulatory Commission Region V 1450 Maria Lane, Suite 210 Walnut Creek, CA 94596-5368
Subject:
Palo Verde Nuclear Generating Station (PVNGS)
Units 1, 2 and 3 Docket Nos. STN 50-528 (License NPF-41)
STN 50-529 (License NPF-51)
STN 50-530 1986 Annual Emergency Plan Exercise File: 86-002-493 Re'ferences: (1) Letter dated August 3,
1983, from J.
B.
Martin, NkC, to E. E. Van Brunt, ANPP, regarding Emergency Preparedness Exercises.
(2) ANPP Policy and Procedures Manual No. 7N409.09.00.
Dear Mr. Martin:
Attached for your review and comment are the Objectives and Extent of Play for the 1986 PVNGS Annual Emergency Plan Exercise scheduled for October 29, 1986. These Objectives and Extent of Play are submitted pursuant to the above references.
The off-site elements of the Objectives and Extent of Play have been coordinated among the cognizant state and local emergency response agencies.
If you are in need of clarification or additional information, please contact Dennis Yows at (602) 932-5300, extension 6280.
Very trul' yours, Mf J. G. Ilay es Vice President Nuclear Production JGil/DGY/rw cc:
- 0. M. De Michele
'ot A H033b m.
E. E. Van llrunt, Jr.
ElA 60 :7,t Hd 9-W W r.
G. M. Temple A. C. Gehr 3!4 03M33W N
EXERCISE OBJECTIVES AND EXTENT OF PLAY 1 Obiectives 1.1 Onsite Arizona Nuclear Power Project (ANPP)
Demonstrate the ability to assess plant conditions, classify the event, and identify projected trends and potential conse-quences.
Demo'nstrate the ability to alert, notify, and mobilize Palo Verde Nuclear Generating Station (PVNGS) emer8ency response personnel
~~
within the time frames specified in the Emergency Plan.
Demonstrate the ability of ANPP to notify agencies in a timely manner.
Demonstrate the adequacy of the Emergency Plan and Emergency Plan Implementing Procedures both in terms of management control of an emergency situation and workability of the procedures at all levels.
Demonstrate the adequacy of security access control to PVNGS emer8ency response facilities.
Demonstrate the effectiveness and availability of appropriate emergency equipment.
Demonstrate the ability to determine actual or potential offsite radiological hazards and make timely Protection Action Recommenda-tions to offsite agencies.
Demonstrate the ability to track plume passage and monitor contam-ination.
Demonstrate the ability to gather samples and analyze them in a radiological laboratory setting.
1.2 Offsite (State of Arizona, County of Maricopa)
Demonstrate that emergency response organizations can alert and mobilize emergency response personnel.
Demonstrate the ability to deploy appropriate equipment / personnel in a timely manner.
Demonstrate that timely and accurate decisions can be made re-garding Protective Actions for the Plume Exposure Pathway Emer- ~'-
gency Planning Zone (EPZ).
a Page 2 EXERCISE OlUECTIVES AND EXTENT OF PLAY Demonstrate that the Radiological Technical Organization can provide assessment and analysis and make appropriate recommen-dations for Protective Actions of a simulated release or radio-iodine and noble gases.
Demonstrate that the Monitoring pool has the capability to perform terrestrial monitoring tasks.
4 l
]
Demonstrate the capability to establish and operate a Reception j
and Care Center.
Demonstrate access control and traffic regulation in the Plume Exposure Pathway EPZ.
Demonstrate the capability to control access to emergency facili-ties in order to maintain security during an emergency.
4 1.3 Joint (Arizona Nuclear Power Project, State of Arizona, and County of Maricopa)
Demonstrate timely coordination and release of information to the media through coordinated action by state, county, and utility elements.
i s
Demonstrate that emergency response organizations can activate and staff the direction and control facilities in a timely fashion.
i Demonstrate the functional adequacy of emergency facilities.
Demonstrate the ability to coordinate Protective Actions in the Plume Exposure Pathway EPZ.
j Demonstrate the adequacy of communication links between government emergency facilities, field teams, and the utility's emergency j
facilities.
Demonstrate the adequacy of communications with public via news 1
media and through other public information channels; i.e.,
Emer-gency Broadcast System (EBS), Rumor Control, etc.
Demonstrate the ability to implement personnel dosimetry for both utility and government emergency response personnel.
~a.
Demonstrate the ability to petform onsite and offsite dose assess-ment in a timely manner.
l 1
l 2
Page 3
_ EXERCISE LBJECTIVES AND EXTENT OF PLAY 2 Activation of all Emergency Response Facilities in accordance with plans and procedures.
PVNGS Unit 2 Control Room and Satellite Technical Support Center (STSC) (activities performed in simulator).
Technical Support Center (TSC), Operations Support Center (OSC),
Emergency Operations Facility (EOF), Corporate Emergency Center (CEC) and Forward News Center (FNC).
State Emergency Operations Center / Technical Operations Center (EOC/ TOC) including:
Public Inquiry Center, Joint Emergency News Center (JENC).
Maricopa County EOC.
Radiological Emergency Assessment Team (REAT) Center.
REAT Forward Center.
Maricopa County Sheriff's Office (MCS0) On Scene Command Post.
Reception and Care Center (1)
I aw
.