ML20209H225

From kanterella
Jump to navigation Jump to search
Requests Labor & Matls Cost Estimates for NRC-initiated Installation of Contingency Telecommunications Equipment at Site.Region III Will Issue Purchase Order Upon Receipt of Estimates
ML20209H225
Person / Time
Site: Palisades 
Issue date: 09/08/1986
From: Hind J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Burnet J
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
References
NUDOCS 8609150192
Download: ML20209H225 (3)


Text

,

i SEP 8 886 Docket No. 50-255 Consumers Power Company ATTN: Mr. Jim Burnet Emergency Preparedness Coordinator 27782 Blue Star Memorial Highway Covert, MI 49043 Gentlemen:

SUBJECT:

COST ESTIMATE FROM CONSUMERS POWER COMPANY FOR THE INSTALLATION OF ADDITIONAL CIRCUITRY AT THE PALISADES NUCLEAR POWER PLANT'S E0F BUILDING AND PERMISSION TO USE SITE PROPERTY FOR CONTINGENCY TELECOMMUNICATIONS Reference is made to a communications survey which was conducted at the Palisades facility by an NRC contractor representative during October 1983.

Based upon this survey, NRC Region III is initiating arrangements for the installation of contingency telecommunication equipment at the Palisades site.

These arrangements consist of obtaining Consumers Power Company's cost estimate to install additional telephone circuits in the Emergency Operations Facility, and formalized permission to use space on the Met Tower as described below.

The circuits and antenna location are essential elements of our emergency telecommunications plan for the Palisades site.

It shculd be noted that, with the exception of the equipment installatien requested below, communications equipment will only be installed at any of the communications sites in the event of an actual emergency or NRC participatien drill, and will be removed immediately at the termination of the emergency or drill.

We are seeking Consumers Power Company's estimate for labor and material to accomplish the following tasks:

1.

Install two WE-742 Terminal Blocks; one located in the NRC area of the EOF (manor home) and the other at the telephone cabic junction box located at the rear of the Transmitter Building at the EOF. The outside terminal block should be enclosed in a weatherproof box to protect it from the elements and shculd be marked for NRC Emergency use Only.

2.

Install two DC control pairs (voice quality circuits) from the EOF l

terminal block to the telephone cable junction box at the rear I

of the Transmitter Building at the EOF.

3.

Agree to reserve an area at the 50 meter level of the Met Tower for use by the NRC as a repeater site.

Following receipt of your estimate, NPC Pegion III will issue the recessary purchase order. Work should not commence prior to receipt of the purchase order.

h 0609150192 860900 PDR ADOCK 05000255 y

k P

PDR

~

Consumers Power Company SEP 8 sa6 If you should have any questions regarding the above, please feel free to contact either Ruth LaFreniere (312) 790-5577 or Linda Kers (312) 790-5711 of my staff.

Enclosed for your information are the frequencies that the NRC equipment may use at this site. We appreciate your assistance in this matter.

Sincerely, (Y

gackfb

. Hind Director Division of Radiation Safety and Safeguards

Enclosure:

Transmitter Frequencies cc w/ enclosure:

Senior Resident Inspector Palisades P. Loomis, Consumers Power Company cc w/o enclosure:

K. Perkins, OIE S. Cohen, T8 D. Herman, BIFC l

RIII RI!!

RI!

R' RIII

@Ke gb b

1 Qr#

geEI.L1h.)

$n 1

e Hind aFreniere 8

08/AV86

{]4 yg fff.,

goo i

~.

ENCLOSURE TSC AND EOF 46.63 166.725 168.550 411.750 46.99 166.775 169.350 411.929 46.81 168.250 169.100 412.150 168.400 165.6625 412.200 166.6125 169.100 417.300 167.100 165.6625 417.350 169.750 417.500 417.800 MET TOWER Transmit Receive Transmit Receive Transmit Receive 49.73 46.63 168.400 166.6125 411.750 417.300 49.77 46.99 167.100 169.750 411.925 417.350 49.91 46.81 169.350 166.725 412.150 417.500 412.200 417.800 All power levels will be at 6 watts or less.

-