ML20209G286

From kanterella
Jump to navigation Jump to search
Advises That Lll Requested to Prepare Form 189 for FY82/83 by 810809,describing Accomplishments,Schedule,Requested Funding & List of Capital Equipment W/Priority Assignment
ML20209G286
Person / Time
Issue date: 06/29/1981
From: Bassett O
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Lagrone J
ENERGY, DEPT. OF
Shared Package
ML20209A640 List: ... further results
References
CON-FIN-A-0116, CON-FIN-A-116, FOIA-85-782 NUDOCS 8702050328
Download: ML20209G286 (4)


Text

',...

DIST:

J Subj Hoskins:CY L

Circ Fabic:CY Chron Riggs:CY 4

Beach:RDG Kelber:CY l-Beach:CY Bassett:CY JUN 2 91981 Mr. J. LaGrone Manager San Francisco Operations Office U. S. Department of Energy 1333 Broadway-Wells Fargo Building Oakland, California 94612

Dear Mr. LaGrone:

FY 1982 PROGRAM ASSlHPTIONS FOR LAWRENCE LIVERMORE NATIONAL LABORATORY (LLL)

Based on the enclosed FY 1982 program assumptions. Lawrence Livermore National Laboratory is requested to prepare seven copies of the FY 1982/83189's by August 9.1981. These 189's will describe the expected accomplishments, schedule, requested funding, and include a list of capital equipment with a priority assignment. The 189's are considered both in tems of the FY 1982 work orders and for allocating the RES Budget for FY 1983. The FY 1982 resources are only planning estimates subject to appropriation and other agency program requirements. A new form 189 for use by all DOE laboratories has been drawn up by NRC and DOE headquarters staff with consultation with the DOE field offices.

This is being printed and should be distributed by Mr. Barber's office within the next week. An example is enclosed. When possible the new fom should be used.

The final FY 1982/83189's are due after receipt of FY 1982 funding and should include a listing of all technical reports published during FY 1981. The report listing will include report number, title, date, author (s), and date published. A listing of specific reports that will be mblished during FY 1982 should also be included. including title, aut1or(s), type of report (quarterly, progress, or data), and estimated date of publication. This listing should include NUREG reports but not include papers planned for technical journals, papers to be presented at technical symposia. listing of monthly highlights, or administrative reports.

g Sincerely.

/

L p

enmmAt SIGNED BY: O. E. BASSCTT.

V hik B70205o328 870120

0. E. Bassett. Director NRO 782 PDR Division of Accident Evaluation
g

Enclosures:

f 1.

Sanple new NRC Form 189 2.

List of Program Assumptions j f

.i. FrgracrAssumptions i p M0 8 SI0

- :.] 9 7

  • "'"%l........ cer.. w. t y.Cle1 end W-5 " >i.............. A..Dr..Ba.C.ty..

.BAach/Hos. kins...Fa.bic.[g'.

.lj

..B as s et t....

""*j..................................... 6gy 8,1..,,,,,,6/22/.81......<.9/fr.$.H........ 6/[. r.....

.6/.GTa1....

l NRC4C;M 189 U.S. NUCLEAR i-;EGULATORY COMMISSION DATE CP Wac/OfAL (3416

-\\

) PROJECT AND BUDGET PROPOSAL FOR NRC WORK O NEW O REvisieN No.

PROJECT TITLE FIN NUMBER I

i~Rc.AR~vM.ER NRC OFFICE OCE CONTRACTOR N,T,"jCTOR ACCovNT S t.T E DOE S&R NUMBER COGNIZANT PE RSONN EL ORGANIZATION FT5 PHONE NUMBER fER6000F PERFORMANCE N..C PROJECT MANAGER STARTING DATE OTHE,1 NRC TECHNICAL STAFF COMPLETION DATE DOE PROJECT MAN AGER PRINCIPA L INVESTIG ATOR(S)

Ti.

br STAFF YE ARS OF E FFORT /Round to nearest renrst of a yearl FY 81 FY 82 FY 83 FY 84 rY 85 DWect Scientific /Tectinical Other Dnct (Graded)

T TOTAL DIRECT STAFF YEARS COST PROPOSAL Direct Solaries Meterial and Services (Excluding ADP)

ADP Support Subcontreets mi e indirect Labor Costs Otner (Specoh)

~~

Generst and Adrmnestrative I s)

$ 7 7

TOTAL OPERATING COST CAPITAL EQUIPMENT FIN CHARGED:

TOTAL PROJECT COST

,y 92 OGiosta NovtMstm ot;tusta sANUAar stamuARY MAAGM L

MONTHLY PontCAST gypgggg APm4 MAY JUNE JULY AUGUST SEPTEMttR NRG FORM 439 M il b

f j

g GENERAL INSTRUCTIONS JUSTIFICATION FOR PROGRAM SUPPORT

i

('

This is an explanation for Program Support to be submitted by contractors engaged i

in Nuclear Regulatory Research activities. This document is used basically by l

technical personnel. The schedule should provide, where applicable, data described l

below.

1 l

Instructions:

i The instructions set forth below are provided as guides.

It is recognized that in 1

certain areas of research and development it will not be appropriate to follow these l

guides precisely.

l Items:

l 1.

The objective should be written by the principal investigator and describe the project or work effort in specific terms.

It is not intended that historical data be included. This should be a summary not to exceed 200 words.

t 2&3.

Describe briefly the actual results in FY 1981 and expected activities and results in FY 1982 and 1983. Description should provide reader with sufficient information to evaluate the proposed effort in light of dollars 4

i estimated with greater emphasis on detail in the current year. The initial i

portion of the FY 1981,1982 and 1983 narrative should be a sumary of 200 l

words or less, of the activities and results in the year. Include within I

the 200 words, major milestone activities that will provide a basis for the phasing and pacing of the work.

4.

In those cases where the research and development is project oriented or i

l where task-type contracts are involved, description should cover period of i

time to bring project to completion.

In case of continuing research effort contracted for more than one year the total remaining years presently under contract should be described.

i 5.

When it is known that similar work will be performed by the contractor or elsewhere with Government or private support, indicate the relationship.

This should be stated with a brief explanation of how the work is coordinated.

6.

FY 1981-83 proposal should include a listing of all technical reports published during FY 1981 under the subject task or program. The report listing should include report number, title, date, author (s), and date published. A listing of specific reports that will be published during FY 1982 should also be j

included, including title, author, type of report (progress, topical, or data) and estimated date of publication. This listing should not include papers planned for technical journals or papers to be presented at technical symposia. Nor should it include a listing of monthly highlight or adninistrative l

reports.

7.

Where the project requires significant expenditures for materials and/or subcontracts, such items should be described, the estimate given and an explanation of the reasons for uses of such items submitted.

L v

~ *

..* ~

~

F t

(

FY 1982 PROGRAM ASSUMPTIONS PROGRAM: AE TITLE: BWR CONTAINMENT POOL DYNAMICS FIN N0: A0ll6 CONTRACTOR: LLL SITE: LIVERMORE STATE: CALIFORNIA NRC TECHNICAL MONITOR:

T. LEE PRINCIPAL INVESTIGATOR:

E. MCCAULEY OBJECTIVE: LIAIS0N FOR FULL SCALE STEAM CONDENSATION TESTS t o est BUDGET ACTIVITY: 60190+40 FY 1982 PROGRAM ASSUMPTIONS:

$200K FY 1982 SCOPE:

THE FOLLOWING TASKS ARE TO BE PERFORMED AS A CONTINUATION OF THIS PROGRAM:

THE CONTRACTOR WILL ACT AS THE NRC'S PRINCIPAL LIAISON FOR THE FULL SCALE STEAM CONDENSATION TESTS THAT ARE BEING PERFORMED AT THE JAERI TEST FACILITY IN JAPAN, GKSS FACILITY IN GERMANY AND KU0SHENG PLANT IN TAIWAN. THE CONTRACTOR WILL BE THE DESIGNATED U.S. RECIPIENT OF DATA GENERATED BY THESE TESTS AND WILL:

1.

GENERATE DATA REPORTS FOR EACH TEST AND DISSEMINATE TO DESIGNATED ORGANIZATIONS PER NRC INSTRUCTION.

2.

PROVIDE TECHNICAL EVALUATION OF THE TEST DATA AND DEVELOP A MORE FUNDAMENTAL UNDERSTANDING OF THE STEAM VENTING PHENOMENA. TECHNICAL EVALUATION OF ALL TEST RESULTS SHOULD BE PLACED IN THE CONTEXT OF RESOLVING OUTSTANDING LICENSING ISSUES.

3.

PERFORM OTHER LIAISON ACTIVITIES WITH THE JAERI, GKSS, AND KU0SHENG TEST PROGRAMS PER NRC INSTRUCTION.

4.

DATA REPORTS TO BE PROVIDED FOR EACH TEST. PROGRESS REPORTS TO BE PROVIDED TO NRC TECHNICAL MONITOR ON MONTHLY BASIS.

5.

THOSE JAERI, GKSS, AND KU0SHENG REPORTS ( AND THEIR EVALUATIONS) THAT ARE DESIGNATED PROPRIETARY SHALL ONLY BE DISSEMINATED TO NRC. THE APPROPRIATE CARE IN HANDLING SUCH REPORTS MUST BE EXERCISED BY THE CONTRACTOR WHILE PROCURING TRANSLATIONS.