ML20209G265

From kanterella
Jump to navigation Jump to search
Forwards Ew Mccauley Request for Official Foreign Travel to Gkss,Federal Republic of Germany from 810808-0903.Request Disapproved.Mccauley Scheduled to Visit for 2 Wks Beginning 810601 to Save Travel Money
ML20209G265
Person / Time
Issue date: 06/15/1981
From: Bassett O
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Lagrone J
ENERGY, DEPT. OF
Shared Package
ML20209A640 List: ... further results
References
FOIA-85-782 NUDOCS 8702050320
Download: ML20209G265 (5)


Text

_

Distribution:

3ebJ JUN 151981 TLeer/f[

afb r/f SFabic r/f l

OEBessett Mr. J. LaGrose. Neosger l

San Frescisce,0persticas Office c

u. S. separteset of Energy l

1333 trendumP4 dells Farge Building Oakland. California 94612 l

Dear Mr. LaGrose:

Enclosed please find letC Foru 445 for E. W. McCauley's foreign travel to GKSS. FRG from August 8.1981 through Septeder 3.1981. This request is disapproved.

Dr. McCaulty is scheduled to be in GESS. FRG for two weeks beginning 4

l June 1,1981.

In order to save travel money we suggest that the listed business be attended to during the June trip.

Sincerely.

p At 51ogED ** o. E ***'

l g

0. E. Bassett. Director Division of Accident Evaluation Office of Nuclear Regulatory Researth

Enclosure:

NRC Form 445 cc:

E. W. McCaulty w/o enc 1.

l I

8702050320 870120 PDR FOIA MORROW 85-782 PDR l

l RECORD fl0TE: This completes action on MCF f RES-001792 d.N

  • Please see previous concurrence sheet
  • RES:DAE:AMBRES:DAE:#E* RES:DAE:DD*

RES:D r

Lee:md Fabic Kelber Bassett G/10/81 6/11/81 6/11/81

g Lawrenca Liv rmora National Laboratory J

NUCLEAR SYSTEMS SAFETY PROGRAM TF81-153 June 19, 1981 E. Aust GKSS Forschungszentrum Geesthacht GmbH Postfach 1160 - Reaktorstrasse 7 - 9 D-2054 Geesthacht - Tesperhude West Germany

Subject:

Loan of U.S. NRC Pressure Transducers

Reference:

1.

U.S. NRC/LLNL Liaison to GKSS Containment Research.

2.

Letter, E. McCauley to E. Aust, May ll, 1981.

3.

Meeting, E. Aust and E. McCauley, June 10, 1981.

4.

Meeting, T. M. Lee and E. McCauley, June 12, 1981.

Dear Mr. Aust:

Enclosed are 9 SensoMetric flush diaphragm 7 bar pressure transducers provided as a loan by the U.S. NRC to the GKSS-PSS program. With each unit a complete calibration history is also supplied. With the single unit provided earlier (Ref. 2), this completes our agreement to supply 10 units for your PSS program use (Refs. 3 and 4).

l As was agreed (Ref. 3), these 9 transducers are supplied without the tubing adapter.

Our drawing of this adapter is, however, enclosed for your use as required.

It is our understanding that this transducer loan will allow for new absolute pressure measurements in the vent pipe exits (to complement the existing piezoelectric units - PG16/22/32) and for new absolute pressure measurements at the vent pipe inlets.

Thank you for your cooperation. We wish you well in your work and look forward to your future test results.

Sincerely, M

Edward W. McCauley, P.E., Ph.D.

F Thermo Fluid Mechanics Group Nuclear Test Engineering Division EWM:lgd 8106.19/0088a cc: T. M. Lee C. J. Anderson F. Eltawila

(

B. R. Bownan M Em a Oportvuty Dipbyer

  • Unvorsayot CaMorru. PO Box 608 Liverrnxa Cavarrna 94550
  • Telephone (415)422 It00
  • Twx 910-386-8339 UCLLL LVW

i T

1 G (S; l

FORSCHUNGSZENTRUM GEESTHACF 4

L y

}

GKSS. Postfach 1160, 2054 Geesthacht ReaktorstraSe 7-9. 2054 Get Telefon: 04152/121 Dr. E. W. McCauley, L-140 Telex: 0218 712 gkssg Telegrarnm:GKSS - Geestha<

Lawrence Livermore National Laboratory P.C. Box 808 INSTITUT FOR AN Livermore, Ca. 94550 U.S.A.

ihr ze.chen:

thre Nachricht vom.

Unser Ze.chen '

8eart>eiter:

Telefon-Durchwar AM/Vol/Br Mr. Vo11brandt 0442/12-508

Subject:

Shipment of test data to LLNL Ref.:

GKSS-PSS Test Program Liaison to USNRC/LLNL

Dear Dr. McCauley,

enclosed we send to you the following experimental material abot; M4 and other material as we agreed during your visit at the GKSS

(

meeting this month:

1. two mag tapes LLL M4A and LLL M4B (total 3027 blocks) content: MEA data of test M4 with correct channel table on th listed in App. A,
2. two mag tapes LLL M4C and LLL M4D (total 3137 blocks) content: PCM data of test M4 (selected pressure channels) dus period: 97 s till 277 s with the correct channel table on tap App. B,
3. three mag tapes LLL M4E, LLL M4F and LLL M4G (total blocks: 4 PCM data of test M4 (all pressure channels) during t content:

160 till 220 s with the correct channel table on tape, listed

4. two copies of the GKSS Jahresbericht 1980,
5. two copies of the report GKSS 81/E/19 (Bdttcher/Kolb),
6. material of the GKSS specialist meeting.

As Mr. Sattler and you discussed at your last visit, the time ax) corrected in the following way:

I f,

Rech tsf orm Gesensche't m,I beschrankter hem 6 r Lti en bamburg Amtspricht Hetbiath HR8 7838 Le ler des Irist te Vorwtsendes O Auts chtsrates Dr W 4 Schtn.dt '

whaftstwheer Dr Ee.ch sc$roder De CisusW :oberr Dr ing H G Sd s%ta

3

-IT GMBH isthacht

ht LAGENTECHNIK Datum:

June 25, 1981 t 3-vent-test specialist e tape, also ing the time e, listed in 509) ae time period:

in App. C,

, has to be for Anlageaiecee,k D,.ing G F kr.wir sos l

=

4 4 4; GKSS

  • ij Dr. E.U. McCauley_

FORSCHUNGSZENTRUM GEESTHACHT GMBH 8

i, TDIF (t) = RTC (t) - ZG 16 (t) + TFILTER + TDIF (INPUT) with RTC (t) = actual real time clock, listed in the time tables, last right column:

MEA M4 : app. D PCM 97-277 s: app. E PCM 160-220 s: app. F ZG (t) = actual test clock, listed in the time tables, left column l

T FILTER = + 30 ms for MEA data 0

for PCM data

=

TDIF (INPUT) = 0 s for MEA and PCM data in test M4 i

The works on the TV-cassettes and the high speed films, respectively time correlation tables are under the way. We are in discussion with video-system manufacturers about the synchronisation problems and we will inform you if we have answers. We could replay the retourned cassettes without information losses.

The adaption work for the NRC-transducers will be managed by our workshops.

Yours truly r.-Ing. Schultheiss ho.llbrandt cc: Dr. Baumghrtel, GRS-FB Dr. T. Lee, USNRC-RSR t

i a

1

-