Text
,
a.
. .
_
/<A
(/
l
APR 2 21987
Carolina Power and Light Company
MTN: Mr. E. E. Utley
Senior Executive Vice President
Power Supply and Engineering
and Construction
P. O. Box 1551
Raleigh, NC 27602
Gentlemen:
SUBJECT: REPORT NOS. 50-325/87-02 AND 50-324/87-02
Thank you for your response of April 2,1987 to our Notice of Violation, issued
on February 27, 1987 concerning activities conducted at your Brunswick facility.
We have evaluated your response and found that although additional information is
required, the . response to Violations 1 and 3 meet the requirements of
10 CFR 2.201; however, the response to Violation 2 does not meet the requirements
of 10 CFR 2.201(a)(3), specifically a date when full compliance will be achieved
was not included.
Based on a telephone call on April 10, 1987 between Mr. C. Dietz of your staff
and Mr. P. Fredrickson of this office, we understand that, in addition to the
full compliance date for Violation 2, you will also provide in a supplemental
response the following information:
Violation 1 - Your evaluation conducted to reach the isolated case conclusion.
Violation 3 - Provide
details
of
what
constitutes
" Increased
management / supervisory attention", which "has been focused on maintenance performed
in this area.'-
I
Attachment 1 - Review Attachment 1 for clarification.
We appreciate your cooperation in this matter.
Sincerely,
(Original signed by V. Brownlee for Reyes)
Luis A. Reyes, Director
Division of Reactor Projects
cc: dK W. Howe, Vice President
Brunswick Nuclear Project
C/R. Dietz, Plant General Manager
8704300498 870422
ADOCK 05000324
G
,
f
L - -- - -- - ------ - -----
- - - - - - - - - - -
-
u'
r;
- n..-
APR 2 21987
Carolina Power and Light Company
2
bcc:tJdC Resident Inspector
Document Control Desk.
State of North Carolina
RI
RI
RI
RII
W
W
lh
LM len:vyg
PF dMckson
DVerrelli
VBrownlee
04/gg87
04/w/87
04/t+f87
04/t ./87
Z