Requests Authorization to Execute BWR Containment Pool Dynamics, Per Encl Std Order for DOE Work
ML20209G011
Person / Time
Issue date: 01/19/1981
From: Shao L
NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES)
To: Lagrone J
ENERGY, DEPT. OF
Shared Package
ML20209A640 List: ... further results
References
CON-FIN-A-0116-1, CON-FIN-A-116-1, FOIA-85-782 NUDOCS 8702050242
Download: ML20209G011 (3)


Text

W

.J-(

JAN 191981 Mr. J. LaGrone, Manager San Francisco Operations Office U. S. Department of Energy 1333 Broadway-Wells Fargo Building Oakland, California 94612

Dear Mr. LaGrone:

FY 1981 NUCLEAR REGULATORY RESEARCH ORDER NO. 60-81-113 FOR LAWRENCE LIVERMORE NATIONAL LABORATORY Please authorize Lawrence Livemore National Laboratory to execute the program described in the enclosed NRC Order.

If this meets with your approval, it is requested that acceptance be indicated on the enclosed fom and the original be returned to the NRC Controller and a copy to this office.

Sincerely,

c.1: n a M

(

! C.Chan Lawrence C. Shao, Acting Director Division of Reactor Safety Research i

Enclosures:

l

1. NRC Order
2. Program Brief DIST Subj cc w/ enclosures:

Circ R. W. Barber, DOE /NSC Chron D. D. Mayhew, DOE /ASEY:DFS Riggs rf E. McCauley, LLNL A. Puglise, CON ddths" S. Fabic, RSR AD Br. file R. Hoskins, RSR C. Johnson, RSR

[

M. Hayes, RES R. Mulgrew, RES 8702050242 870120 L. Tong, RES bbRRO 782 PDR RES:D ARC)03 G RECORD NOTE:

Endorsed 11/14/80, memo Murley to Denton.

SER

(-

&12-

[

)

\\/ vla1 n

c"'= > i" BCM BCMB ' i%.. )np......

SR RSR RSR /

RSR

/..

RSR:D~i g...

~ ~ AQ b.........f.i.e.1 d

...Has.n.....

Lee (Bhis...',,:,,Jof..,............ S u,1,Lvan,,,,,,,

Ho s,L n_,,,,,,,, S h a.:,,,,,,

,qn.........

* * " > 1B./81../..18 1....l.I.lY(81......././//8,1,,z,q81;,,z7/8!...,,,,J./j,/,81

...l!g8!...... !!/g8!......

GC FORM 318 dO 80l #4RCu e240 OFFICIAL RECORD COPY w.

]"j'*]'"

g..

s

( ' l NRC s ORM 173 8

U S NUCLE AR REGUL ATOR Y COMMISSION ORDE R NUMBE A 12-78) 60-81-113 DATE STANDARD ORDER FOR DOE WORK JAN 191981 IEUED TO (DOE Offece)

ISSUED BY: INRC Of fece)

ACCOUNTING CITATION APPROPRIATION SYMSOL Division of Reactor San Francisco Operations Office 31X0200*601 Safety Research

,,,, v,c,

PERFORMING ORGANIZATION AND LOCATION 60190110 FIN NUMSER A0116-1 Lawrence Livermore National Laboratory FIN TITLE FIXED O ESTIMATED @

FROM:

TO:

BWR Containment Pool Dynamics 10/1/80 9/30/81 08 LIGATION AVAILABILITY PROVIDED BY:

A.

THIS ORDER S

276,000

8. TOTAL OF ORDERS PL ACED PRIOR TO THss DATE WITH THE PERFORMING ORGANi2 ATION TN"NS!ie'**CNE"E"'EATI N SYMB L" AN THE fir $nouR c GiTS OF THE 5.165,000 C. TOTAL ORDERS TO DATE (TOTAL A & 8) 5,441,000 D. AMOUNT INCLUDED IN "C" APPLICABLE TO THE " FIN NUMBE R" CITED IN THIS ORDER.

276,000 FINANCI AL FLEXIBILITY:

OgFUNDS WILL NOT BE REPROGRAMMED 8ETWEEN FINS. LINE D CONSTITUTES A LINTATION ON OSLIGATIONS AUTHORIZE D.

O FUNDS MAY BE REPROGRAMMED NOT TO EXCEED 210% OF FIN LEVEL UP TO $50K. LINE C CONSTITUTES A LIMITATION ON 08 LIGATIONS AUTHORIZED.

STANDARD TERMS AND CONDITIONS PROVIDED DOE ARE CONSIDERED PART OF TH15 ORDER UNLESS OTHERWISE NOTED.

ATTACHMENTS:

THE FOLLOWING ATTACHMENTS ARE HERE8Y SECURITY:

MADE A PART OF THIS ORDER:

O WORK ON THIS ORDER IS NOT CLASSIFIED.

O STATEMENT OF WOR K O WORK ON THIS ORDER INVOLVES CLASSIFIED D ADDITIONAL TERMS AND CONDITIONS INFORMATION. NRC FORM 187 l$ ATTACHED.

O OTHER REMARKS:

lh 7 WG AUTfthfTY ACCEPTING ORGANIZATION w

ha c

Director i

feTLE TITLE

'l Division of Reactor Safety Research NIC FORM 173 (2 78)

L 3

SEP 11 1980 4~

FY 1981 PROGRAM BRIEF PROGRAM: WRSR TITLE: BWR CONTAINMENT POOL DYNAMICS FIN: A0ll6 CONTRACTOR: LLL SITE: LIVERMORE STATE: CALIFORNIA NRC TECHNICAL MONITOR:

T. LEE PRINCIPAL INVESTIGATOR:

E. MCCAULEY OBJECTIVE: LIAIS0N FOR FULL SCALE STEAM CONDENSATION TESTS BUDGET ACTIVITY: 60190110 FY 1981 SCOPE

$276K THE FOLLOWING TASKS ARE TO BE PERFORMED AS A CONTINUATION OF THIS PROGRAM:

THE CONTRACTOR WILL ACT AS THE NRC'S PRINCIPLE LIAIS0N FOR THE FULL SCALE STEAM CONDENSATION TESTS THAT ARE BEING PERFORMED AT THE JAERI TEST FACILITY IN JAPAN,

(

GKSS FACILITY IN GERMANY AND KU0SHENG PLANT IN TAIWAN. THE CONTRACTOR WILL BE THE DESIGNATED U.S. RECIPIENT OF DATA GENERATED BY THESE TESTS AND WILL:

1) GENERATE DATA REPORTS FOR EACH TEST AND DISSEMINATE TO DESIGNATED ORGANIZATIONS PER NRC INSTRUCTION.
2) PROVIDE TECHNICAL EVALUATION OF THE TEST DATA AND DEVELOP A MORE FUNDAMENTAL UNDERSTANDING OF THE STEAM VENTING PHENOMENA.

IT WOULD BE DESIRABLE THAT TECHNICAL EVALUATION OF JAERI AND KU0SHENG TEST RESULTS BE PLACED IN CONTEXT OF THE OVERALL TEST DATA BASE, THAT INCLUDES GKSS AND DOMESTIC SOURCES.

3) PERFORM OTHER LIAIS0N ACTIVITIES WITH THE JAERI, GKSS AND KU0SHENG TEST PROGRAMS PER NRC INSTRUCTION.
4) DATA REPORTS TO BE PROVIDED FOR EACH TEST. PROGRESS REPORTS TO BE PROVIDED TO NRC TECHNICAL MONITOR ON MONTHLY BASIS.
5) THOSE JAERI, GKSS AND KU0SHENG REPORTS (AND THEIR EVALUATIONS) THAT ARE

(,