ML20209E620

From kanterella
Jump to navigation Jump to search
Issues Amend 5 to License SNM-1107,incorporating Leak Test Requirements for Sealed Plutonium Sources,Per 870401 Application
ML20209E620
Person / Time
Site: Westinghouse
Issue date: 04/27/1987
From: Rouse L
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Nardi A
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20209E624 List:
References
NUDOCS 8704300087
Download: ML20209E620 (1)


Text

W L

e

~,

FCUF:GHB 70-1151 APR 2 7198/

SNM-1107, Amendment 5 Westinghouse Electric Corporation ATTN: Mr. A. J. Nardi, Manager NES License Administrator P. O. Box 355 Pittsburgh, PA 15230 Gentlemen:

In accordance with your application dated April 1, 1987, and pursuant to Title 10, Code of Federal Regulations, Part 70, Materials License No.

SNM-1107 is hereby amended to incorporate leak test requirements for sealed plutonium sources.

Item 9 of the License is revised to read:

9.

Authorized Use: For use in accordance with statements, representations, and conditions contained in Chapters 2, 3, and 4 of the application dated March 26, 1984, and supplements dated January 4, 1985, May 14, 1986, August 8,1986, September 22, 1986, and April 1, 1987, and letters dated June 25, 1985, and April 23, 1986.

All other conditions of this license shall remain the same.

Your letter of April 1,1987, which submitted a revised Site Plan, is acknowledged.

Enclosed for your information is a copy of our Safety Evaluation Report.

FOR THE NUCLEAR REGULATORY COMMISSION priginal Signed By:

Leland C. Rouse, Chief Fuel Cycle Safety Branch Division of Fuel Cycle, Medical, Academic, and Commercial Use Safety, NMSS

Enclosure:

Safety Evaluation Report DISTRIBUTION w/ encl.

CDocket.No. 70 115124 NMSS R/F FCUF R/F FCSB R/F VLTharpe GHBidinger(2)

Region II PDR DWeiss, LFMB GBennington, SGTB EBrach, SGLB SH0 GTroup, RII

[

0FC: FCUF:

FCUF
FCSB NAME:GHBidinger:ht :VL re
LCR us DATE:04/d/87
04/h87
04/f/1/87 8704300087 s70427 PDR ADOCK 07001151 C

PDR