License 50-23363-02 for Ultra Technology,Inc,Authorizing Use of Am-241 in Troxler Model 3216 Surface Moisture Gauges & Campbell Pacific Nuclear Model MC-M or 503 Series Gauges
ML20209D010
Person / Time
Site: 03020421
Issue date: 10/14/1986
From: Riedlinger B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
Shared Package
ML20209D015 List:
References
50-23363-02, 50-23363-2, NUDOCS 8702040388
Download: ML20209D010 (3)


See also: IR 05000233/1963002

Text

{{#Wiki_filter:- _u m a m m m a m m m m m m m m A m m m m u m a m A m m m m m m m m m m m m a m a m m m m m m m m mim m m m m q . -

1 3 Ig h@c Forsn 373 , PAGE OF PAGES D 13) U.S. NUCLEAR REGULATORY CoMMISSloN . l

MATERIALS LICENSE Pursuant to the Atomic Energy Act of 1954, as amended, the Energy Reorganization Act of 1974 (Public Law 93-438), and Title 10,

Code of Federal Regulations, Chapter I, Parts 30,31,32,33,34,35,40 and 70, and in reliance on statements and representations I

g l heretofore made by the license *, a license is hereby issued authorizing the licensee to receive, acquire, possess, and transfer byproduct, y source, and special nuclear material designated below; to use such material for the purpose (s) and at the place (s) designated below; to N deliver or transfer such material to pers6ns authorized to receive it in accordance with the regulations of the applicable Part(s). This E license shall be deemed to contain the conditions specified in Section 183 of the Atomic Energy Act of 1954, as amended, and is M subject to all applicable rules, regulations and orders of the Nuclear Regulatory Commission now or hereafter in effect and to any l conditions specified below. Licensee lN iNilj 1. Ultra Technology, Inc. 3. License number 50-23363-02 IIl ' ,- . 2. Pouch 340122 .p c p , . . Prudhoe Bay, Alaska 99734 ); " 4. Expiration date October 31, 1991 E 4 ,

5. Docket or - E 03 -20421 Reference No. p 6. Byprodu:t, source, and/or 7. Chemical and/or physical _ 8. Maximum amount that licensee I ' 4 special nuclear material form sinay possess at any one time E _ /s 'under this license N l ,- . , c + A. Americium 241 A'! A.- Sedled neutron cources A. <Not to exceed N l /n ~(Troxler Dwg. A-102451); i 50 mil 11 curies i/ " N ' ' (persource y - , , , _. p B. Americium 241 }- B.- Sealed ~ netitrin ' sources ; ~ B.

Not to exceed

l < (Campbell ~ Pacific Nuefear.

  • 50 millicuries

b ,p' .ModellCPN-131)I' per source E ' ' c > i e ~~ , , 9. Authorized use , , h > - s \\ i . R , A. For use in Troxler Model 3216 Surface moisture. gauges to meastire properties of g ' ' - E l construction materials.i . '; c: p , B. For use in Campbell Pacific Nuclear Model MC-M or Modelf503 Series gauges to I measure properties of construction materials. h ~ , - - . l CONDITIONS l ' N l 10. Licensed material may be used at temporary job sites near Prudhoe Bay, Alaska, fE which are based at the ARC 0 MCC contractors camp approximately 4 miles north of l ! l the Deadhorse Airport, and at temporary job sites of the licensee anywhere in g the United States where the U. S. Nuclear Regulatory Commission maintains p I l jurisdiction for regulating the use of licensed material. H ' N 11. Licensed material shall be used by, or under the supervision and in the physical E presence of, Donald S. Heiken or other individuals who have completed the l manufacturers training course in the use of the devices and have been designated g by Donald S. Heiken, Radiation Protection Officer. The licensee shall maintain p records of individuals designated as users. l I 12. Scaled sources containing licensed material shall not be opened. . j i ! k f i / j 8702040388 861014 ! /i '

REOS LIC30 i ! ___- m m ma m m o m ,.5 0 - 2 3 3,m im m63-02 PDR _ o-o-

p-A1MEZAIX;MsAMMAMEMMxisi_MEEMMs-mmmmmmmmmmmmmmmmmmmm mmm9 U.S. NUCLEAR REGULATORY CoMMISSloN

j RC Form 37:A * PAGE OF PAGES 4 Licerac number E M 50-23363-02 E 4 MATERIALS LICENSE E Docket er Reference number 1 SUPPLEMENTARY SHEET 030-20421 E i E 1 E 1 4 4 i CONDITIONS E- 1 E, i E q (continued) g i R: 1 13. A. (1) The source (s) specified in Item (s) 7.A. shall be tested for leakage E: 4 and/or contamination at intervals not to exceed 6 months and the E: source (s) specified in Item (s) 7.B. shall be tested for leakage and/or f: g contamination at intervals not to exceed one year. Any source received g J from another person which is not accompanied by a certificate indicating gi d that a test was performed within;6; months .before the transfer shall pI: 4 not be put into use until tested. E: ' M R: lb Any source in storage"and not being used need not b'e[ tested. When the f: q source is removed,from storage for use or transfer to another person, it g .] shall be tested before use or transfer. gi 1 f . . ,E: 3 C. ';re test sha]1'be capable'of detecting the presence 'of 0.005 microcurie of lE: , A cau!oactive mat crial on the test sample. If'the test reveals the presence 'E! . ] ot 0.005 microcurie or more of removable contamination, the source shall be f _j removed from service andl decontaminated, repaired, or disposed of in p 1 accordance with Commission regulations. j A report shall be . filed within 5 p: 1 days of the'date theJ1eak1 test result is known with the U. S. Nuclear R:

1

Regulatory Commission, Region V;' Nuclear Materials Safety and Safeguards E: 3 Branch; 1450' Maria Lane,' Suite 210; Valnut Creek; California" 94596. The Et j] report shall specify the source involved, the test results, and corrective f .

j

action taken. sRecords'of leak test results_shall be kept in units of g!

1

microcuries and 'shall be maintained for inspection by the' Commission. I), jl Records may be disposed of followJng Commission inspection. i f{E E' .a D. The licensee is authorized to collect leak test samples for analysis by ij Troxler Electronic Laboratories or Campbell Pacific Nuclear Corporation, or

j

tests for leakage and/or contamination shall,be performed by persons y!g

1

specifically licensed by the Commission or an Agreement State to perform jg,

1

such services. - ip' ! l1 E E 14. The licensee shall conduct a physical inventory every six (6) months to account b for all sources and/or devices received and possessed under the license. l

j

Records of the inventories shall be maintaine;{ for two (2) years from the date g

1

of each inventory. p

1

- p ~l 15. The licensee may transport licensed material f r. accordance with the provisions E f of 10 CFR Part 71, " Packaging and Transportation of Radioactive Material". l E

16.

The Campbell Pacific Nuclear Model 503 series gauges must not be used to g measure moisture and density at depths beyond 10 feet. g l fE

ls . 3 E ,s , i lE i a I lR TRUEHVE.E3UrmpA%vM,2iiiU52555[TTEZ51fmusL%s2rmrhr-


A-------.-------,-----

q U.S, NUCLEAR REGULATORY COMMISSION 3 3 y

C Form 374A

, o, ,yg , License number l 50-23363-02 1 MATERIALS LICENSE i Docket or Reference number SUPPLEMENTARY SHEET 030-20421 E N I N N R CONDITIONS N N l (continued) g I , 17. Except as specifically provided otherwise in this license, the licensee shall I conduct its program in accordance with the statements, representations, and I procedures contained in the documents including any enclosures, If sted below. l The Nuclear Regulatory Commission's regulations shall govern unless the g statements, representations and procedures.in the licensee's application and g correspondence are more restrictive t6an 'the re[ulations. g .. > ' ~ m gy ; g A. Application and letter (dated September 12, 1986 ds i B. Letter received September 19, 1986 /s N d C. Step by step instructions dated October 2,1986 ~ /3 l D. Letter with certificate of completion dated October 2,[19{6, g - x x v p , ., U,, ,J L. .;w ,f ' ~ l fr /4 g i ' r. t - - ( (f j f 0 l ! %l i h -) '^~f '

E 2 a t p, , x ' 7j f i \\?/. t. .s N cf e B h ,'+. i . ] , a ]~j,, / ' ,, / _, 3 / ( l t' c '..,

's, -" ' p s , ,, h,.) -;) ,fk . \\ h . ." ,f [].; g , ) , y[-{ , , ,pm . ~. 4 " > .. , 3 'di.s a_ % N s _3 e;; - ; ' P; p. . (e*} h %. H ' ' .- , O, .,l,4 h ' ,' A Y QI,f f' .. - +: ., _,, p ,, s, . . ' s ; ,', , ' ; . . (;) E ' ,/ 4 . 3p .;v g < - .9:,_l. jlt ' a ,, x g " / ,- & 3) g Y "' p g r r a < ' ~* v. " 5 - , r , g s r - < FOR THE'U.S. NUCLEAR REGULATORY COMMISSION p 5 original af gned by B. A. Riedlinger E Date October 14, 1986 By l Beth A. Riedlinger g Health Physicist (Licensing) y Nuclear Materials Safety Section l Region V E E R 5 5 > N W H I M E 1 . (N