O LIMERICK GENERATING STATION UNIT 1 l
AND CONNON PLANT FIRST 10-YEAR INTERVAL AUGNENTED INSERVICE INSPECTION PROGRAM O
/
PHILADELPHIA ELECTRIC COMPANY 1
!O 8702040202 870130ADOCK 05000352 PDR PDR O
1
~
LIMERICK GENERATING STATION UNIT 1 l
AND COMMON PLANT FIRST 10-YEAR INTERVAL AUGMENTED INSERVICE INSPECTION PROGRAM LIST OF EFFECTIVE PAGES Number Revision Date l All Pages 2
01/87 l
l l
LEP-1 Rev. 2, 01/97
-: JA
i i
1 LIMERICK GENERATING STATION UNIT 1 l
AND COMMON PLANT FIRST 10-YEAR INTERVAL AUGMENTED INSERVICE INSPECTION PROGRAM TABLE OF CONTENTS l.0 INTRODUCTION l
1.1 General
- O 2.0 AUGMENTED REQUIREMENTS - REACTOR PRESSURE VESSEL (RPV) 2.1 Regulatory Guide 1.150, Revision 1, February 1983, with Appendix A, Alternate Method.
Ultrasonic Testing of i
Reactor Vessel Nelds During Preservice and Inservice Examinations" 2.2 NUREG 0619, November 1980, "BWR Feedwater Nossle and Control Rod Drive Return Line Nossle Cracking.
Resolution of Generic Technical Activity A-10".
I 2.3 IE Bulletin No. 80-07, April 4, 1980, "BNR Jet Pump Assembly Failure" (NOREG CR 3052) 2.4 IE Bulletin No. 80-13, May 12, 1980, " Cracking in Core Spray Spargers" l
l 2.5 SIL No. 409, "Incore Dry Tube Cracks" l
2.6 SIL No. 420, " Inspection of Jet Pump Sensing Lines" j
l 2.7 SIL No. 433, " Inspection of Shroud Head Bolts" i Rev. 2, 01/87
'5Y
', j'
-m,,
n-,. - - _,, _ -
w,n we
,wo---
i TABLE OF CONTENTS (Cont'd) 3.0 AUGMENTED REQUIREMENTS - NUCLEAR PIPING SYSTEMS 3.1 High Energy Piping between Containment Isolation Valves and First Outboard Restraint for Which No Breaks are Postulated 3.2 RHR Heat Exchanger Pressure Retaining Bolting 3.3 Weld Centerline Markings 3.4 NUREG 0313, Rev. 1, July 1980, " Technical Report on Material Selection and Processing Guidelines for BWR Coolant Pressure Boundary Piping.
Resolution of Generic Technical Activity A-42".
3.5 Outboard Feedwater Check Valves HV-41-lF074A and B l Table No.
l T3.0-1 Summary of "No Break" Boundaries l T3.0-2 "No Break". Boundary Relief Request Summary O
I 11 -
Rev. 2, 01/87 5-y
,,.-.-..-w..w..-,p--------..---%-,,,-wrw,,,,..~-_g-
,_,,,,..p.,,,+w.-___---,,,,%--.,. - -,
--,-.w-.
---,-,------v----------
1.0 INTRODUCTION
l 1.1 GENERAL This program defines the Limerick Generating Station Unit 1 and Common Plant inservice inspection requirements which are beyond those required by Section XI of the ASME Boiler and Pressure Vessel Code and augments The First 10-Year Interval Inservice
^
Inspection Program.
These augmented inspection requirements result from Philadelphia Electric Company (PECo) regulatory and licensing commitments.
Also identified are augmented inspections to be performed at PECo's option based on manufacturer's recommendations.
Unless otherwise noted, this program is to be used in conjunction with the First 10-Year Interval Inservice i
Inspection Program in that the requirements for responsibility (Section 1.6), records (Section 1.7), and examination methods (Section 1.8) apply to both Inservice Inspection Programs.
4 l
l l
l 1.0-1 Rev. 2, 01/87
{}
l'
.'1
f 2.0 AUGMENTED REQUIREMENTS - REACTOR PRESSURE VESSEL (RPV)
The following are the augmented inservice inspections applicable to Limerick Generating Station Unit 1 RPV.
These requirements are applicable during each inservice inspection interval or at other times as noted.
The examination method, frequency, and coverage are specified in " Philadelphia Electric Company Limerick Generating Station Unit 1 and Common Plant First 10-Year Interval Inservice Inspection Examination Plan".
2.1 REGULATORY GUIDE 1.150, REVISION 1, FEBRUARY 1983, WITH APPENDIX A, ALTERNATE METHOD.
" ULTRASONIC TESTING OF REACTOE VESSEL WELDS DURING PRESERVICE AND INSERVICE EXAMINATIONS" ASME Section XI inservice ultrasonic examinations of Unit 1 RPV Category B-A and B-D welds will be performed in accordance with l Reg. Guide 1.150, Alternate Method, which outlines acceptable methods for remote automatic and manual ultrasonic equipment certification and calibration, recording and sizing of l indications, and the reporting of examination results.
2.2 NUREG 0619, NOVEMBER 1980, "BWR FEEDWATER NOZZLE AND CONTROL ROD DRIVE RETURN LINE NOZZLE CRACKING, RESOLUTION OF GENERIC TECHNICAL ACTIVITY A-10."
l p Inservice inspections of the RPV Feedwater Nozzles will include the examinations specified in NUREG 0619, Section 4.3, for the v
Triple-Sleeve Sparger design.
The Control Rod Drive (CRD) Return Line Nozzles are not used at Limerick.
The capped CRD nozzles will be examined in accordance with ASME Section XI only.
t 1
2.2.1 For RPV nozzles greater than 10" nominal inside l
diameter, augmented ultrasonic examinations of the nozzle bore region will be performed in conjunction with
]
the examination of the nozzle blend radii required by j
ASME Section XI, Category B-D, Item No. B3.100.
2.3 IE BULLETIN NO. 80-07, APRIL 4, 1980, "BWR JET PUMP ASSEMBLY FAILURE."
(numEG CR 3052)
~
Inservice inspections of the jet pumps will include visual examinations of the jet pump structures, the hold-down beam assembly, hold-downs, and wedge and restrainer assembly.
Ultrasonic examinations of the jet pump hold-down beam ligament areas at the beam bolt will be performed in accordance with the requirements of NUREG-CR-3052.
2.0-1 Rev. 2, 01/87
- (:)
4 4
LGS AUGMENTED ISI PROGRAM 2.4 IE BULLETIN NO. 80-13, MAY 12, 1980, " CRACKING IN CORE
\\
SPRAY SPARGERS" Inservice Inspections of the RPV internals will include visual examinations of the Core Spray Spargers and the segment of piping between the inlet nozzle and the vessel shroud.
These examinations will be performed in accordance with the requirements of IE BULLETIN No. 80-13.
l 2.5 SIL NO. 409, "INCORE DRY TUBE CRACKS" Inservice Inspections of the RPV internals will include visual examinations of the Intermediate Range Monitor (IRM) and Source Range Monitor (SRM) dry tubes.
These examinations will be performed at PEco's option based on the recommendations of Service and Information Letter No. 409 for original equipment with water chemistry that meets EPRI guidelines.
l 2.6 SIL NO. 420, " INSPECTION OF JET PUMP SENSING LINES" Inservice Inspections of the RPV internals will include visual examinations of the Jet Pump Instrumentation Lines and Supports.
These examinations will be performed at PECo's option based on the recommendations of Service and Information Letter No. 420.
l 2.7 SIL 433, " INSPECTION OF SHROUD HEAD BOLTS" O
Inservice Inspections of the RPV internals will include ultrasonic examination of the Shroud Head Bolts.
These examinations will be performed at PEco's option based on the i
recommendations of Service and Information Letter No. 433.
2.0-2 Rev. 2, 01/87 l-
.-.---,---..------e.-
-.--n
_.----,.--,-..--,,,,._n,
--,,,,,-_..,e-
---.,,,.,,--,.,n-.,-------w n,,-
, e
LGS AUGMENTED ISI PROGRAM 3.0 AUGMENTED REQUIREMENTS - NUCLEAR PIPING SYSTEMS The following are the augmented inservice inspections applicable to Limerick Generating Station Unit 1 nuclear piping systems.
These requirements are applicable during each inservice inspection interval or at other times as noted.
The examination method, frequency, and coverage are specified in " Limerick Generating Station Unit 1 and Common Plant First 10-Year Interval Inservice Inspection Examination Plan".
3.1 HIGH ENERGY PIPING BETNEEN CONTAINMENT ISOLATION VALVES AND FIRST Ouia0ARD REatuAINT FOR NBICE NO aminyg ang POSTULATED (RsrsuRED TO AS "NO BREAE" aru m ?IES IN THIS PROGRAN)
NRC Mechanical Engineering Branch (MEB) Technical Position MEB 3-1 (NUREG 0800) prescribes that cracks or breaks need not be postulated for containment isolation piping provided that certain i
stress criteria are met and all pipe welds are volumetrically examined during each inservice inspection interval.
The Limerick Generating Station FSAR Section 3.6.2.1 commits PEco to performing these examinations for all "no break" piping welds.
The augmented inservice inspection will include volumetric I
examination of 100% of the circumferential and longitudinal pipe welds within the "no break" boundaries.
These examinations will be performed in accordance with the requirements of ASME Section O
xI with the exceveton that the weid end reautred volume nall be extended to include essentially 100% of the through wall thickness.
1
(
The "no break" boundaries are as summarized in Table 3.0-1.
l 3il.1 RELIEF REQUEST Circumferential and longitudinal butt welds in piping within the
[
"no break" boundaries.
l l 3.1.1.1 REQUIREMENT FROM WHICE RELIEF IS REQUESTED NUREG 0800, Technical Position MEB 3-1, requires volumetric examination of 100% of the circumferential and longitudinal piping welds within the "no break" boundaries.
The examinations are to be performed once per inspection interval in accordance with the Limerick Generating Station Unit 1 and Common Plant First 10-Year Interval Inservice Inspection Program except that the weld and required volume shall be extended to include essentially 100% of the through wall thickness.
Ultrasonic examinations shall include the following:
3.0-1 Rev. 2, 01/87
LGS AUGMEN 'ED ISI PROGRAM (1)
Nominal 45 degree angle beam scans of the weld and 1
required volume in two beam path directions j
perpendicular to the weld axis.
(2)
Nominal 45 degree angle beam scans of the weld and required volume in two beam path directions parallel to j
the weld axis.
Relief is requested from the requirement to examine 100% of the weld and required volume with scans in two beam path directions perpendicular to the weld axis for the welds identified in Table 3.0-2.
4 l 3.1.1.2 JUSTIFICATION For volumetric examinations perpendicular to the weld axis, complete coverage of the weld required volume in two beam path directions may not be achievable due to joint configuration / component design. Non-parallel ID and OD surfaces in certain valve and fitting designs may preclude complete coverage of the component base material adjacent to the weld.
Complete coverage is achievable in one direction perpendicular and two directions parallel to the weld axis.
Complete surface examinations are also achievable.
4 l 3.1.1.3 ALTERNATE TO ASME SECTION XI REQUIREMENTS
! ([)
Required examinations will be performed to the extent practical.
Base metal scans, limited by joint configuration / component design, may use full vee path calibrations and/or smaller transducer.
Difficult configurations may be divided into i
examination " zones" requiring a separate calibration in which case an average material thickness over the." sone" will be used.
Visual examinations will be performed during periodic system pressure tests.
t t
i i
3.0-2 Rev. 2, 01/87
.{ j l
4 LGS AUGMENTED ISI PROGRAM TABLE 3.0-1
SUMMARY
OF "NO BREAK" BOUNDARIES ASME SECTION XI BOUNDARY SYSTEM DESCRIPTION P4ID Main Steam Penetration X-7 A,B,C,D from outer N-41 isolation valves HV-lf028A,B,C,D upstream thru inner isolation valves to and including first upstream elbow-to-pipe weld.
4 Main Steam Outer isolation valves BV-lF028A,B,C,D M-41 downstream to and including first downstream elbow-to-pipe weld.
1 Feedwater Penetrations X-9A,B from check M-41 valves IF010A,B upstream thru valves HV-lF074A,B.
l Feedwater Thru valves HV-lF074A,B upstream thru M-41 valves HV-lF032A,B and 1058, M-55 l
including first upstream valve p
1058-to-pipe weld and v
downstream valves EV-109A,B-to-pipe i
5 L
Feedwater Thru valves HV-lF032A,B upstream M-41 to and including first weld outside reactor building.
HPCI Penetration X-11 from and including M-55 pipe-to-tee upstream weld i
of first tee thru isolation valve HV-lF003.
i HPCI Thru valve HV-lF003 to and including M-55 pipe-to-elbow upstream weld of third elbow.
1 J
T3.0-1(1)
Rev. 2, 01/87 h ()
n j-I, n
i em m-e.---y~we..---m--,,-.y-*ew m,-.-we,,
-w-
~~.vv--
m--- - - - - -
LGS AUGMENTED ISI PROGRAM TABLE 3.0-1 (Cont'd)
O.
SUMMARY
OF "NO BREAX" BOUNDARIES ASME SECTION XI BOUNDARY SYSTEM DESCRIPTION psIn RWCU Penetration X-14 from and including M-44 pipe-to-elbow upstream weld of second elbow thru isolation valve HV-lF001 and upstream weld of valve HV-lF040.
RWCU Thru valve HV-lF004 thru valve M-44 RV-lF040.
RWCU Thru valve HV-lF040 to and including M-44 elbow-to pipe downstream of weld of first elbow.
RCIC Penetration X-10 upstream thru M-49 inner isolation valve RV-lF007 to and including elbow-to-pipe downstream of weld of second elbow RCIC Penetration X-10 downstream thru M-49 outer isolation valve HV-lF008 to and including pipe-to-pipe weld downstream of third elbow.
l l
l T3.0-1(2)
Rev. 2, 01/87 O
i j
LOS LUGaBE%TED C ROGRAM T* OLE 3.0-2 40 SREAK-DOUNDAov RELIEF REQUEST SuuMARv (See Note 3)
ASME ASME Percent rk Section XI Section XI Component /
Examinetton Complete SIC Relief Cetemorv reem wo.
weid wo.
Metwod (Se. woe. i)
(S.e not. 2)
Reauest 8-J+
89.11 MSA-022 vol & Sur 95% Vol-100% Sur 2
3.1.1 8-J+
89.11 MSA-023R Vol & Sur 90% vol-100% Sur 2
3.1.1 8-J+
89.11 hSS-024 Vol & Sur 95% vol-100% Sur 2
3.1.1 8-J+
89.11 MSS-025 vol & Sur 90% vol-100% Sur 2
3.1.1 8-J+
89.11 MSC-022 Vol & Sur 95% vol-100% Sur 2
3.1.1 8-J+
89.11 MSC-023 Vol & Sur 90% vol-100% Sur 2
3.1.1 8-J+
89.11 MSD-022 Vol & Sur 95% vol-100% Sur 2
3.1.1 8-J+
89.11 MSD-023 Vol & Sur 90% Vol-1C0% Sur 2
3.1.1 8-J+
89.11 FwA-033 Vol & Sur 95% vol-100% Sur 2
3.1.1 8-J+
89.11 FWA-034 Vol & Sur 90% vol-100% Sur 2
3.1.1 8-J+
89.11 FWS-030 Vol & Sur 95% vol-100% Sur 2
3.1.1 8-J+
89.11 FwS-031 Vol & Sur 90% Vol-100% Sur 2
3.1.1 8-J+
89.11 Rw-019 Vol & Sur 90% vol-100% Sur 2
3.1.1 8-J+
89.21 RC-131 Vol & Sur 85% Vol-100% Sur 8
3.1.1 C-F+
C5.21 HP-022 Vol & Sur 95% vol-100% Sur 8
3.1.1 C-F+
C5.21 FwA-037 vol & Sur 90% vol-100% Sur 12 3.1.1 C-F+
C5.21 FwA-038 Vol & Sur 90% vol-100% Sur 12 3.1.1 C-F+
C5.21 FwS-035 Vol & Sur 90% vol-100% Sur 12 3.1.1 C-F+
C5.21 FwS-036 vol & Sur 90% vol-100% Sur 12 3.1.1
+
NA RC-Ol8A Vol & Sur 95% Vol-100% Sur 8
3.1.1 Vol - Volumetric Sur - Surface
+ - Augmented NOTES:
1.
The percent complete values Itsted are based on (1) results of preservice examinations. (2) differences betmeen preservice and inservice Code edition requirements for examination coverage. and (3) taproved inservice esamination technteues. Refer to the preservice enemination records for component description and details of obstructing Condition.
2.
SIC numbers shown correspond to the Safety Impact Categories per the Preservice Inspection Program and, for conventence, are re-stated below:
SIC #2.
Reactor coolant pressure boundary sold (RCPS): Weld is normally pressurized during power operation.
Inbeerd containment isolation (or RCPS) valve performs RCP8 teolation function.
Significant RCPg leakage is detecteo by leak detection systems.
The plant can be esfely shut down using unaffected systems.
SIC #8.
HPCI. RCIC. and IIWCU eystem melde outside containment: During plant peser operetten.
significant leakage from lines which are presourized with steam or hot ester is detected and automatically isolated by leek detection systems. None of thes2 systems are required for normal plant shutdown.
Plant can be safely shut down using normal shutdown methods.
SIC #12.
Feedester system weld outside contelnments Weld is pressurized during plant power operation.
Lesh detection systems detect significant leakage. Containment isolation occurs automatically upon loss of feedeater flow.
Other systems are available to provide makeup water to the RPV during plant shutdown.
73.0-2(1)
Rev. 2. 01/87
LCS AUGaIENTED !!
A'3 1
. TABLE 3.0-2 (Cont d)
'800 BRE Ae( SOUNDARV RELIEF REQUEST $UesetARY i
1 v
i l
3.
The rettef requests in this table are based on the information prepared for the Limerick Generating 1
1 l
Station Unit 1 and Common Plant First 10-Year Interval Inservice Inspection Enamination Plan.
These j
relief requests may be updated as the inservice esaminations are scheduled and performed.
l 1
i l
1 i
i
}
i
}
l i
i e
e 4
l 1
l I
i, T3.0-2(2)
Rev. 2. 01/87 I
I i
i i
LGS AUGMENTED ISI PROGRAM 3.2 RHR HEAT EXCHANGER PRESSURE RETAINING BOLTING During this first 10-year inservice inspection interval only, the
^' ass 2 RHR heat exchanger pressure retaining bolting (1-1/8"7) or one heat exchanger will be visually (VT-3) examined once either in place or when disassembled at a time of maintenance or concurrent with the scheduled volumetric examination of the shell welds.
This augmented requirement fulfills PECo's commitment in support of the Preservice Inspection Relief Request #28.
3.3 WELD CENTERLINE MARKINGS Prior to performing inservice inspections, the weld centerline identification marking shall be checked and reworked as applicable for compliance with the following requirements:
"The weld crown shall be teasured and the dimensions recorded.
Reference marks shall be permanently stamped or vibro-etched on each side of the weld in the base metal of the component outside the examination area.
The marks shall be placed in adjacent pairs, nominally three inches from the weld centerline in four locations around the circumference, 90 degrees apart, and shall be completed before weld preparation.
Where three inches of access is not available en the base metal because of geometric limitations, the location shall be at the nearest practical distance provided that the marks are placed at equal distances
(])
from the weld centerline."
3.4 NUREG 0313, REV.
1, JULY 1980, " TECHNICAL REPORT ON MATERIAL SELECTION AND PROCESSING GUIDELINES FOR BWR COOLANT PRESSURE BOUNDARY PIPING.
RESOLUTION OF GENERIC TECHNICAL ACTIVITY A-42" Outboard of the outboard containment isolation valve, 304 stainless steel piping is used in the RWCU system operating at temperatures above 200 degrees Farenheit.
This is a nonconforming conditon per NUREG-0313, Revision 1.
Accordingly, an augmented inservice inspection program shall be established for this piping.
The augmented inservice inspection will consist of the following:
1)
Class 2 portion (between valves HV-lF004 and HV-lF040) will be inspected at least once in no more than 80 months.
If no incidence of stress corrosion cracking is revealed during the first 80 months, the examination frequency thereafter can revert to 120 months as prescribed in ASME Section XI.
2)
No augmented inservice inspection beyond the Section XI visual examination is required for the Class 3 portion.
g-)
3.0-3 Rev.
2, 01/87 b/
3.5 OUTBOARD FEEDWATER CHECK VALVES HV-41-lF074A AND B General Design Criteria GDC 51, " Fracture Prevention of Containment Pressure Boundary", requires that under operating, maintenance, testing, and postulated accident conditions, (1) the ferritic materials of the containment pressure boundary behave in a non-brittle manner and (2) the probability of rapidly propagating fracture is minimized.
To assure that the materials of fabrication of the 24" feedwater check valves HV-41-lF074A & B provide an acceptable margin of safety, relative to fracture toughness of the reactor containment pressure boundary, inservice inspections shall include surface examinations (either magnetic partical or liquid penetrant) of both the internal and external valve body surfaces of both valves.
These augmented examinations will be performed during the first refueling outage.
Subsequent inspections will be in accordance with the requirements of the Limerick Generating Station Unit 1 and Common Plant First 10-Year Interval Inservice Inspection Program.
O l
i i
3.0-4 Rev.
2, 01/87 l
l
i i
- O l
l i
i-i 1
i i
i l
i 4
I LIMERICK GENERATING STATION UNIT 1
)
NO C0ttiON PLANT 4
f I
ITEMIZED LISTING OF COMPONENTS O
SueaeCT To ex4MiNATioN ouRiNG THE FIRST 10-YEAR INTERVAL
.i t
l t
l e
l l
l l O IL i
i l
.. ~.. -
s.
.w.
?
' Pag 2 Wo.
1 01/22/87
(_f LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID B-A RPV 1
B-A B1.11 AA BOTTOM SIDE SHELL CIRCUMFERENTIAL WELD SHELL 1 TO BOTTOM HEAD R P,V 1
B-A Bl.11 AA TOP SIDE SHELL CIRCUMFERENTIAL WELD SHELL 1 TO BOTTOM HEAD RPV 1
B-A B1.11 AB BOTTOM SIDE SHELL CIRCUMFERENTIAL WELD SHELL 1 TO SHELL 2 RPV 1
D-A B1.11 AB TOP SIDE SHELL CIRCUMFERENTIAL WELD SHELL 1 TO SHELL 2
'~*
- RPV 1
B-A B1.11 AC BOTTOM SIDE SHELL CIRCUMFERENTIAL~ WELD SHELL 2 TO SHELL 3 RPV 1
B-A B1.11 AC TOP SIDE SHELL CIRCUMFERENTIAL WELD
()
SHELL 2 TO SHELL 3
\\-
RPV 1
B-A B1.11 AD BOTTOM SIDE SHELL CIRCUMFERENTIAL WELD SHELL 3 TO SHELL 4 RPV 1
B-A B1.11 AD TOP SIDE SHELL CIRCIMFERENTIAL WELD SHELL 3 TO SHELL 4 RPV 1
B-A B1.11 AE BOTTOM SIDE SHELL CIRCUMFERENTIAL WELD SHELL 4 TO SHELL 5 RPV 1
B-A B1.11 AE TOP SIDE SHELL CIRCUMFERENTIAL WELD SHELL 4 TO SHELL 5 RPV 1
B-A B1.12 BA LEFT SIDE SHELL CIRCUMFERENTIAL WELD SHELL 1 VERTICAL SEAM MELD RPV 1
B-A B1.12 BA RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 1 VERTICAL SEAM WELD RPV 1
B-A B1.12 BB LEFT SIDE SHELL LONGITUDINAL WELD SHELL 1 VERTICAL SEAM WELD RPV 1
B-A B1.12 BB RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 1 VERTICAL SEAM WELD
~
RPV 1
B-A B1.12 BC LEFT SIDE SHELL LONGITUDINAL WELD SHELL 1 VERTICAL SEAM WELD
'. i
1Page No.
2 01/22/87
(,w).
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEY.
ID RPV 1
B-A B1.12 BC RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 1 VERTICAL SEAM WELD RPV 1
B-A Bl.12 BD LEFT SIDE SHELL LONGITUDINAL WELD SHELL 2 VERTICAL SEAM WELD RPV 1
B-A Bl.12 BD RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 2 VERTICAL SEAM WELD RPV 1
B-A B1.12 BE LEFT SIDE SHELL LONGITUDINAL WELD SHELL 2 VERTICAL SEAM WELD RPV 1
B-A B1.12 BE RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 2 VERTICAL SEAM WELD RPV 1
B-A B1.12 BF LEFT SIDE SHELL LONGITUDINAL WELD c/-
SHELL 2 VERTICAL SEAM WELD
_Cs RPV 1
B-A B1.12 BF RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 2 VERTICAL SEAM WELD RPV 1
B-A B1.12 BG LEFT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV
'1 B-A B1.12 BG RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV 1
B-A B1.12 BH LEFT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV 1
B-A B1.12 BH RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV 1
B-A B1.12 BJ LEFT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV 1
B-A B1.12 BJ RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 3 VERTICAL SEAM WELD RPV 1
B-A B1.12 BK LEFT SIDE SHELL LONGITUDINAL WELD p
SHELL 4 VERTICAL SEAM WELD RPV 1-B-A B1.12 BK RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 4 VERTICAL SEAM WELD RPV 1
B-A B1.12 BM LEFT SIDE SHELL LONGITUDINAL WELD SHELL 4 VERTICAL SEAM WELD i
~
?page No.
3 01/22/87
~
(_)p LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID RPV 1
B-A B1.12 BM RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 4 VERTICAL SEAM WELD RPV 1
B-A B1.12 BN LEFT SIDE SHELL LONGITUDINRL WELD SHELL 5 VERTICAL SEAM WELD RPV 1
B-A B1.12 BN RIGHT SIDE SHELL LONGITUDINAL WELD SHELL 5 VERTICAL SEAM WELD RPV 1
B-A B1.12 BP LEFT SIDE SHELL LONGITUDINAL WELD SHELL 5 VERTICAL SEAM WELD RPV 1
B-A B1.12 BP RIGHT SIDE SHELL LONGITUDINAL WELD
'4**
SHELL 5 VERTICAL SEAM WELD RPV 1
B-A B1.21 AH BOTTOM SIDE HEAD CIRCUMFERENTIAL WELD J'
CLOSURE HEAD DOLLAR PLATE WELD RPV 1
B-A D1.21 AH TOP SIDE HEAD CIRCUMFERENTIAL WELD CLOSURE HEAD DOLLAR PLATE WELD RPV 1
B-A B1.21 AJ HEAD CIRCUMFERENTIAL WELD BOTTOM HEAD DOLLAR PLATE WELD RPV 1
B-A B1.22 DA HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1
B-A B1.22 DB HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1
B-A B1.22 DC HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1
B-A B1.22 DD HEAD MERIDIONAL WELD i*~
B-A B1.22 DE HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1
B-A B1.22 DF HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1.
B-A B1.22 DG HEAD MERIDIONAL WELD BOTTOM HEAD WELD RPV 1
B-A B1.22 DH HEAD MERIDIONAL WELD
{
CLOSURE HEAD WELD w.
h l
1Page No.
4 01/22/87 j
():'-
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
~
CLASS CAT ITEM ID RPV 1
B-A B1.22 DJ HEAD MERIDIONAL WELD CLOSURE HEAD WELD RPV 1
B-A B1.22 DK HEAD MERIDIONAL WELD CLOSURE HEAD WELD RPV 1
B-A B1.22 DM HEAD MERIDIONAL WELD CLOSURE HEAD WELD RPV 1
B-A B1.22 DN HEAD MERIDIONAL WELD CLOSURE HEAD WELD RPV 1
B-A B1.22 DP HEAD MERIDIONAL WELD
( * ;""?#f CLOSURE HEAD WELD RPV 1
B-A B1.30 AF BOTTOM SIDE SHELL TO FLANGE WELD SHELL 5 TO RPV CLOSURE FLANGE b.
x-RPV 1
B-A B1.30 AF TOP SIDE SHELL TO FLANGE WELD
~
SHELL 5 TO RPV CLOSURE FLANGE RPV 1
B-A B1.40 AG HEAD TO FLANGE WELD CLOSURE HEAD TO FLANGE WELD 1
O O
3 4
,v.--
-n-
., - - +-
a N
,l
<t p %
'Page No.
5 01/22/87
(-)~n
(,
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID B-D RPV 1
B-D B3.90 N1A NOZZLE TO VESSEL WELD RECIRC. OUTLET LOOP A RP,V 1
B-D B3.90 N1B NOZZLE TO VESSEL WELD RECIRC. OUTLET LOOP B RPV 1
B-D B3.90 N2A NOZZLE TO VESSEL WELD RECIRC. INLET LOOP B RPV 1
B-D B3.90 N2B NOZZLE TO VESSEL WELD RECIRC. INLET LOOP B RPV 1
B-D B3.90 N2C NOZZLE TO VESSEL WELD RECIRC. INLET !.OOP B RpV 1
B-D
/'%-
~B3.90 N2D NOZZLE TO VESSEL WELD RECIRC. INLET LOOP B RDV 1
B-D B3.90 N2E NOZZLE TO VESSEL WELD RECIRC. INLET LOOP B RPV 1
B-D B3.90 NEF NOZZLE TO VESSEL WELD RECIRC. INLET LOOP A RPV 1
B-D B3.90 N2G NOZZLE TO VESSEL WELD RECIRC. INLET LOOP A RPV 1
B-D B3.90 N2H NOZZLE TO VESSEL WELD RECIRC. INLET LOOP A RPV 1
B-D B3.90 N2J NOZZLE TO VESSEL WELD RECIRC. INLET LOOP A RPV 1
B-D B3.90 N2K NOZZLE TO VESSEL WELD RECIRC. INLET LOOP A
~
RPV 1
B-D B3.90 N3A NOZZLE TO VESSEL WELD MAIN STEAM LOOP A RPV 1
B-D B3.90 N3B NOZZLE TO VESSEL WELD MAIN STEAM LOOP B RPV 1
B-D B3.90 N3C NOZZLE TO VESSEL WELD
{}
MAIN STEAM LOOP C L'
w w
-m--
w e-
--o,r,
--w
m 1Page No.
6 01/22/87 (f
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME
. CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID RPV 1
B-D B3.90 N3D NOZZLE TO VESSEL WELD MAIN STEAM LOOP D RPV 1
B-D B3.90 N4A NOZZLE TO VESSEL WELD FEEDWATER LOOP A RPV 1
B-D B3.90 N4B NOZZLE TO VESSEL WELD FEEDWATER LOOP B RPV 1
D-D B3.90 N4C NOZZLE TO VESSEL WELD FEEDWATER LOOP C RPV 1
B-D B3.90 N4D NOZZLE TO VESSEL WELD
B-D B3.90 N4E NOZZLE TO VESSEL WELD FEEDWATER LOOP E
)
RPV 1
B-D B3.90 N4F NOZZLE TO VESSEL WELD FEEDWATER LOOP F RPV 1
B-D B3.90 NSA NOZZLE TO VESSEL WELD CORE SPRAY LOOP B 4
RPV 1
B-D B3.90 NSB NOZZLE TO VESSEL WELD CORE SPRAY LOOP A RPV 1
B-D B3.90 N6A NOZZLE TO VESSEL WELD RPV HEAD SPRAY RPV 1
B-D B3.90 N6B NOZZLE TO VESSEL WELD RPV HEAD SPRAY (SPARE)
RPV 1
B-D B3.90 N7 NOZZLE TO VESSEL WELD RPV VENT l
RPV 1
B-D B3.90 N8A NOZZLE TO VESSEL WELD JET PUMP INSTRUMENTATION LOOP B RPV 1
B-D B3.90 N8B NOZZLE TO VESSEL WELD JET PUMP INSTRUMENTATION LOOP A RPV 1,
B-D B3.90 N9 NOZZLE TO VESSEL WELD f
CRD RETURN (CAPPED)
($)
RPV 1
B-D B3.90 N17A NOZZLE TO VESSEL WELD LPCI LOOP B a-
- 9
... ~... -
iPage No.
7 01/22/87 IS
~#
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID RPV 1
B-D B3.90 N17B NOZZLE TO VESSEL WELD LPCI LOOP D RPV 1
B-D B3.90 N17C NOZZLE TO VESSEL WELD LPCI LOOP A RPV 1
B-D B3.90 N17D NOZZLE TO VESSEL WELD LPCI LOOP C RPV 1
B-D B3.100 N1A NOZZLE INSIDE RADIUS RECIRC. OUTLET LOOP A RPV 1
B-D B3.100 N1B NOZZLE INSIDE RADIUS RECIRC. OUTLET LOOP B RPV 1
B-D B3.100 N2A NOZZLE INSIDE RADIUS RECIRC. INLET LOOP B RPV 1
B-D B3.100 N2B NOZZLE INSIDE RADIUS RECIRC. INLET LOOP B RPV 1
B-D B3.100 N2C NOZZLE INSIDE RADIUS RECIRC. INLET LOOP B RPV 1
B-D B3.100 N2D NOZZLE INSIDE RADIUS RECIRC. INLET LOOP B RPV 1
B-D B3.100 N2E NOZZLE INSIDE RADIUS RECIRC. INLET LOOP B RPV 1
B-D B3.100 N2F NOZZLE INSIDE RADIUS RECIRC. INLET LOOP A RPV 1
B-D B3.100 N2G NOZZLE INSIDE RADIUS RECIRC. INLET LOOP A RPV 1
B-D B3.100 N2H NOZZLE INSIDE RADIUS RECIRC. INLET LOOP A RPV 1
B-D B3.100 N2J NOZZLE INSIDE RADIUS RECIRC. INLET LOOP A RPV 1
B-D B3.100 N2K NOZZLE INSIDE RADIUS RECIRC. INLET LOOP A l
RPV 1
B-D B3.100 N3A NOZZLE INSIDE RADIUS i
MAIN STEAM LOOP A I
e 4.,-. -.
...w-
,.,y,..
g
-;1
- 6..
'tPage No.
8 01/22/87 LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
'. CLASS CAT ITEM ID RPV 1
B-D B3.100 N3B NOZZLE INSIDE RADIUS MAIN STEAM LOOP B RPV 1
B-D B3.100 N3C NOZZLE INSIDE RADIUS MAIN STEAM LOOP C RPV 1
B-D B3.100 N3D NOZZLE INSIDE RADIUS MAIN STEAM LOOP D RPV 1
B-D B3.100 N4A NOZZLE INSIDE RADIUS FEEDWATER LOOP A RPV 1
B-D B3.100 N4B NOZZLE INSIDE RADIUS
! s.' .
B-D B3.100 N4C NOZZLE INSIDE RADIUS FEEDWATER LOOP C RPV 1
B-D B3.100 N4D NOZZLE INSIDE RADIUS FEEDWATER LOOP D RPV 1
B-D B3.100 N4E NOZZLE INSIDE RADIUS FEEDWATER LOOP E RPV 1
B-D B3.100 N4F NOZZLE INSIDE RADIUS-FEEDWATER LOOP F RPV 1
B-D B3.100 N5A NOZZLE INSIDE RADIUS CORE SPRAY LOOP B RPV 1
B-D B3.100 N5B NOZZLE INSIDE RADIUS CORE SPRAY LOOP A RPV 1
B-D B3.100 N6A NOZZLE INSIDE RADIUS RPV HEAD SPRAY RPV 1
B-D B3.100 N6B NOZZLE INSIDE RADIUS RPV HEAD SPRAY (SPARE)
RPV 1
B-D B3.100 N7 NOZ2LE INSIDE RADIUS RPV VENT RPV 1,
B-D B3.100 N8A NOZZLE INSIDE RADIUS JET PUMP INSTRUMENTATION LOOP B RPV 1
B-D B3.100 N8B NOZZLE INSIDE RADIUS JET PUMP INSTRUMENTATION LOOP A-
?L 4
--,,e
.,w-
.,,-ym.g sem,,-,
-go--
mn
~
4 1Page No.
9
,< ~
01/22/B7
()y_!
LIMERICK GENERATING STATION UNIT 1
+
~
AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
' CLASS CAT ITEM ID 1
RPV 1
B-D B3.100 N9 NOZZLE INSIDE RADIUS CRD RETURN (CAPPED)
RPV 1
B-D B3.100 N17A NOZZLE INSIDE RADIUS LPCI LOOP B RPV 1
B-D B3.100 N17B NOZZLE INSIDE RADIUS LPCI LOOP D RPV 1
B-D B3.100 N17C NOZZLE INSIDE RADIUS LPCI LOOP A RPV 1
B-D B3.100 N17D NOZZLE INSIDE RADIUS c'
,e O
h 4
- Page No.
10
(,.,
01/22/87
)
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESLRIPTION CLASS CAT ITEM ID B-E RPV 1
B-E B4.11 N10 PARTIAL PENETRATION WELDS CORE DIFF PRESS & LIQ CONT NOZZ RPV 1
B-E B4.11 N15 PARTIAL PENETRATION WELDS BOTTOM HEAD DRAIN NOZZLE RPV 1
B-E B4.12 BY CORE LOC.
PARTIAL PENETRATION WELDS STUB TUBE TO RPV & CRD HOUSING RPV 1
B-E B4.13 DY CORE LOC.
PARTIAL PENETRATION WELDS INCORE HOUSING TO RPV RPV 1
B-E B4.13 N11A PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N11B PARTIAL PENETRATION WELDS r,,
INSTRUMENTATION NOZZLE i*
RPV 1
B-E B4.13 N12A PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N12B PARTIAL PENETRATION WELDS j
INSTRUMENTATION NOZZLE 1
RPV 1
B-E B4.13 N12C PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N12D PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N16A PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N16B PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N16C PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE RPV 1
B-E B4.13 N16D PARTIAL PENETRATION WELDS INSTRUMENTATION NOZZLE a
r
..g 1Page No.
11
,y 01/22/87 L
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID o*
B-F RPV 1
B-F B5.10 APE-1MS-LA N3A NOZZLE TO SAFE END MAIN STEAM LOOP A RP,V 1
B-F B5.10 APE-1MS-LB N3B NOZZLE TO SAFE END MAIN STEAM LOOP B RPV 1
B-F B5.10 APE-1MS-LC N3C NOZZLE TO SAFE END MAIN STEAM LOOP C RPV 1
B-F B5.10 APE-1MS-LD N3D NOZZLE TO SAFE END MAIN STEAM LOOP D RPV 1
B-F B5.10 DBA-110-1 N7 NOZZLE TO FLANGE RPV VENT RPV 1
B-F B5.10 DCA-103-1 N6A NOZZLE TO FLANGE RPV 1
B-F B5.10 DCA-103-1 N6B NOZZLE TO FLANGE RPV HEAD SPRAY (SPARE)
RPV 1
B-F B5.10 DCA-318-1 N17B NOZZLE TO SAFE END LPCI LOOP D RPV 1
B-F B5.10 DCA-318-2 N17A NOZZLE TO SAFE END LPCI LOOP B RPV 1
B-F B5.10 DCA-318-3 N17C NOZZLE TO SAFE END LPCI LOOP A 9
RPV 1
B-F B5.10 DCA-318-4 N17D NOZZLE TO SAFE END LPCI LOOP C RPV 1
B-F B5.10 DCA-319-1 N5A NOZZLE TO SAFE END CORE SPRAY LOOP B RPV 1
B-F B5.10 DCA-320-1 NSB NOZZLE TO SAFE END CORE SPRAY LOOP A RPV 1
B-F B5.10 DLA-107-1 N4A NOZZLE TO SAFE END FEEDWATER LOOP A RPV 1
B-F B5.10 DLA-107-1 N4B NOZZLE TO SAFE END FEEDWATER LOOP B IL i i
p 1Page No.
12
/(-y.
01/22/87 1
i' LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
". CLASS CAT ITEM ID RPV 1
B-F B5.10 DLA-107-1 N4C NOZZLE TO SAFE END FEEDWATER LOOP C RPV 1
B-F B5.10 DLA-108-1 N4D NOZZLE TO SAFE END FEEDWATER LOOP D RPV 1
B-F B5.10 DLA-108-1 N4E NOZZLE TO SAFE END FEEDWATER LOOP E RPV 1
B-F B5.10 DLA-108-1 N4F NOZZLE TO SAFE END FEEDWATER LOOP F RPV 1
B-F B5.10 RPV-1IN N8A NOZZLE TO SAFE END e'
B-F B5.10 RPV-IIN N8B NOZZLE TO SAFE END JET PUMP INST. LOOP A
(%.
(,)
RPV 1
B-F B5.10 RPV-1IN N9 NOZZLE TO CAP CONTROL ROD DRIVE RPV 1
B-F B5.10 VRR-1RD-1A NSF NOZZLE TO SAFE END RECIRC. INLET LOOP A RPV 1
B-F B5.10 VRR-1RD-1A N2G NOZZLE TO SAFE END RECIRC. INLET LOOP A RPV 1
B-F B5.10 VRR-1RD-1A N2H NOZZLE TO SAFE END RECIRC. INLET LOOP A RPV 1
B-F B5.10 VRR-1RD-1A N2J NOZZLE TO SAFE END RECIRC. INLET LOOP A RPV 1
B-F B5.10 VRR-1RD-1A N2K NOZZLE TO SAFE END RECIRC. INLET LOOP A RPV 1
B-F B5.10 VRR-1RD-1B N2A NOZZLE TO SAFE END RECIRC. INLET LOOP B RPV 1
B-F B5.10 VRR-1RD-1B N2B NOZZLE TO SAFE END RECIRC. INLET LOOP B RPV 1,
B-F B5.10 VRR-1RD-1B N2C NOZZLE TO SAFE END RECIRC. INLET LOOP B RPV 1
B-F B5.10 VRR-1RD-1B N2D NOZZLE TO SAFE END RECIRC. INLET LOOP B
,A-
,--,-----,n-
-.-----..n w-
s
+
Page No.
13 h
01/22/87
[- U LIMERICK GENERATING STATION UNIT 1
~#
AND COMMON PLANT FIRST 10-YEAR INTERVAL
- l INSERVICE INSPECTION EXAMINATION PLAN 1
SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
~. CLASS CAT ITEM ID RPV 1
B-F B5.10 VRR-1RD-1B N2E NOZZLE TO SAFE END RECIRC. INLET LOOP B RPV 1
B-F B5.10 VRR-1RS-1A N1A NOZZLE TO SAFE END RECIRC. OUTLET LOOP A RPV 1
B-F B5.10 VRR-1RS-1B N1B NOZZLE TO SAFE END RECIRC. OUTLET LOOP B RPV 1
B-F B5.20 N10 NOZZLE TO SAFE END CORE DIFF PRESS & LIQ CONT NOZZ RPV 1
B-F B5.20 N11A NOZZLE TO SAFE END INSTRUMENT NOZZLE
~
RPV 1
B-F B5.20 N11B NOZZLE TO SAFE END INSTRUMENT NOZZLE
)
RPV 1
B-F B5.20 N12A NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.20 N12B NOZZLE TO SAFE END INSTRUMENT NOZZLE
.RPV 1
B-F B5.20 N12C NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.20 N12D NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.20 N15 NOZZLE TO SAFE END BOTTOM HEAD DRAIN NOZZLE RPV 1
B-F B5.20 N16A NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.20 N16B NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.20 N16C NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1,
B-F B5. 20 N16D NOZZLE TO SAFE END INSTRUMENT NOZZLE RPV 1
B-F B5.130 APE-1MS-LA WA01 SAFE END TO PIPE MAIN STEAM LOOP A
' i*g.
i
1Page No.
14 01/22/87
-[se t
\\'#
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID RPV 1
B-F B5.130 APE-1MS-LB WB01 SAFE END TO PIPE MAIN STEAM LOOP B RPV 1
B-F B5.130 APE-1MS-LC WC01 SAFE END TO PIPE MAIN STEAM LOOP C RPV 1
B-F B5.130 APE-1MS-LD WD01 SAFE END TO PIPE MAIN STEAM LOOP D RPV 1
B-F B5.130 DCA-318-1 FW1 SAFE END TO PIPE LPCI LOOP B RPV 1
B-F B5.130 DCA-318-2 FW1 SAFE END TO PIPE LPCI LOOP A RPV 1
B-F B5.130 DCA-318-3 FW1 SAFE END TO PIPE
~.' :
_N_/
RPV 1
B-F B5.130 DCA-318-4 FW1 SAFE END TO PIPE LPCI LOOP D RPV 1
B-F B5.130 DCA-319-1 FW1 SAFE END TO PIPE CORE SPRAY LOOP A RPV 1
B-F B5.130 DCA-320-1 FW1 SAFE END TO PIPE CORE SPRAY LOOP B RPV 1
B-F B5.130 DLA-107-1 S4A SAFE END TO PIPE FEEDWATER LOOP A RPV 1
B-F B5.130 DLA-107-1 S4B SAFE END TO PIPE FEEDWATER LOOP B RPV 1
B-F B5.130 DLA-107-1 S4C SAFE END TO PIPE FEEDWATER LOOP C RPV 1
B-F B5.130 DLA-108-1 S4D SAFE END TO PIPE FEEDWATER LOOP D RPV 1
B-F B5.130 DLA-108-1 S4E SAFE END TO PIPE FEEDWATER LOOP E RPV 1.
B-F B5.130 DLA-108-1 S4F SAFE END TO PIPE FEEDWATER LOOP F RPV 1
B-F B5.130 RPV-11N S8A SAFE END TO PENT. SEAL JET PUMP INST. LOOP B w
r-,--.,~-r
r m
--em-e=-i.
m-----
w--
-w--
'h.d 1Page No.
15 01/22/87
'( h LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION
~
. CLOSS CAT ITEM ID RPV 1
B-F B5.130 RPV-11N S8B SRFE END TO PENT SEAL JET PUMP INST. LOOP A RPV 1
B-F B5.130 VRR-1RD-1A WA15 SAFE END TO PIPE RECIRC. INLET N2F, LOOP A RPV 1
B-F B5.130 VRR-1RD-1A WA16 SAFE END TO PIPE RECIRC. INLET N2G, LOOP A RPV 1
B-F B5.130 VRR-1RD-1A WA17 SAFE END TO PIPE RECIRC. INLET N2H, LOOP A RPV 1
B-F B5.130 VRR-1RD-1A WA18 SAFE END TO PIPE RECIRC. INLET N2J, LOOP A RPV 1
B-F B5.130 VRR-1RD-1A WA19 SAFE END TO PIPE RECIRC. INLET N2K, LOOP A RPV 1
B-F B5.130 VRR-1RD-1B WB15 SAFE END'TO PIPE RECIRC. INLET N2A, LOOP B RPV 1
B-F B5.130 VRR-1RD-1B WB16 SAFE END TO PIPE RECIRC. INLET N2B, LOOP B RPV 1-B-F B5.130 VRR-1RD-1B WB17 SAFE END TO PIPE RECIRC. INLET N2C, LOOP B RPV 1
B-F B5.130 VRR-1RD-1B WB18 SAFE END TO PIPE RECIRC. INLET NED, LOOP B RPV 1
B-F B5.130 VRR-1RD-1B WB19 SAFE END TO PIPE RECIRC. INLET N2E, LOOP B RPV 1
B-F B5.130 VRR-1RS-1A WA1 SAFE END TO PIPE RECIRC. OUTLET LOOP A RPV 1
B-F B5.130 VRR-1RS-1B WB1 SAFE END TO PIPE RECIRC. OUTLET LOOP B
.O i ;
1
- j 1
1Page No.
16 i
01/22/87
(~ 'd
\\l LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVHL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME
. CODE CODE COMPONENT DESCRIPTION
~
CLOSS CAT ITEM ID o*
B-G-1 RPV 1
B-G-1 B6.10 SN 1 - SN 76 BOLTING ) 2 IN. DIA.
CLOSURE HEAD NUTS RPV 1
B-G-1 B6.20 SN 1 - SN 76 BOLTING ) 2 IN. DIA.
CLOSURE STUDS IN PLACE RPV 1
B-G-1 B6.30 SN 18 - SN 21 BOLTING ) 2 IN. DIA.
CLOSURE STUDS WHEN REMOVED RPV 1
B-G-1 B6.40 HOLES #1 - #76 BOLTING ) 2 IN. DIA.
THREADS IN FLANGE e "'?",$
RPV 1
B-G-1 B6.50 SN 1 - SN 76 BOLTING ) 2 IN. DIA.
CLOSURE WASHERS O e
( ).
D O
\\
s.
Page No.
17 01/22/B7
('3h LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID 0*
B-G-2 RPV-1 B-G-2 B7.10 16 STDS 32 NUTS BOLTING 2" DIA. & SMALLER RPV HEAD SPRAY BOLTING RP,V 1
B-G-2 B7.10 16 STDS 32 NUTS BOLTING 2" DIA. & SMALLER RPV SPARE HEAD SPRAY BOLTING RPV 1
B-G-2 B7.10 16 STDS 32 NUTS BOLTING 2" DIA. & SMALLER RPV VENT BOLTING RPV 1
B-G-2 B7.80 1480 BLTSCa8/FLG CRD HOUSING FLANGES
?..'
9 e
8 O
h l
e i
l O
,--,.,-,.-,,,,,--.,m_,--.
y
--n--------,
l
'iPage No.
18 (c)'
01/22/87 o
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID i
o*
B-H RPV 1
B-H B8.10 BY AZ.
INTEGRALLY WELDED ATTACH.
CLOSURE HEAD LIFTING LUGS RPy 1
B-H B8.10 BY AZ.
INTREGALLY WELDED ATTACH.
B-H B8.10 CG INTEGRALLY WELDED ATTACH.
SKIRT TO KNUCKLE WELD
) :s.,e :.*
n 9
/%.;
bJ e
m ll O
- o i
m-r
-~e>,
m
- u
,w s
w g--,
r-,
.,.e y~w
-even.em
-,,----w-ww-+,----------------e
,,,----w--
-w--w------v-w----
r
--,,-e n
2.*)
- $[.j! }
/
Page No.
19 01/22/87
(
LIMcRICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID B-N-1 RPV 1
B-N-1 B13.10 VESSEL INTERIOR CORE SUPPORT PLATE RP,V 1
B-N-1 B13.10 VESSEL INTERIOR STEAM DRYER RPV 1
B-N-1 B13.10 VESSEL INTERIOR STEAM SEPARATOR RPV 1
B-N-1 B 13.10 VESSEL INTERIOR SHROUD WELD RPV 1
B-N-1 B13.10 VESSEL INTERIOR TOP GUIDE ASSEMBLY RPV 1
B-N-1 B13.10 VESSEL INTERIOR
.v)(*
SHROUD HEAD RPV 1
B-N-1 B13.10 BY AZ.
VESSEL INTERIOR FEEDWATER SPARGER ASSEMBLIES RPV 1
B-N-1 B13.10 BY AZ.
VESSEL INTERIOR JET PUMPS AND SHROUD ANNULUS RPV 1
B-N-1 B13.10 BY CORE LOC.
VESSEL INTERIOR FUEL CELL COMPONENTS RPV 1
B-N-1 B13.10 BY CORE LOC.
VESSEL INTERIOR CRD ASASEMBLIES RPV 1
B-N-1 B13.10 BY CORE LOC.
VESSEL INTERIOR INCORE HOUSING ASSEMBLIES RPV 1
B-N-1 B13.10 BY ELE., AZ.
VESSEL INTERIOR CORE SPRAY HEADERS AND SPARGERS O
4 n,, -. -. - - - -.,
-e- -. -
,,,.m
,,,,,---_,-------,,---.-,,--------e-
--.m
't
- Page No.
20 01/22/87 (4
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID o*
B-N-2 RPV 1
B-N-2 B13.20 BY AZ.
INTERIOR ATTACH. BELTLINE JET PUMP RISER PADS RPV 1
B-N-2 B13.20 BY AZ.
INTERIOR ATTACH. BELTLINE SURVEILLANCE SPECIMEN BRACKETS RPV 1
B-N-2 B13.20 BY ELE., AZ.
INTERIOR ATTACH. BELTLINE CORE SPRAY BRACKET RPV 1
B-N-2 D13.21 BY AZ.
INTERIOR ATTACHMENT STEAM DRYER, HOLDDOWN BRACKETS
's -
'3d RPV 1
B-N-2 B13.21 BY AZ.
INTERIOR ATTACHMENT FEEDWATER BRACKETS RPV 1
B-N-2 B13.21 BY CORE LOC.
INTERIOR ATTACHMENT INCORE HOUSING TO RPV RPV 1
B-N-2 B13.21 BY ELE., AZ.
INTERIOR ATTACHMENT GUIDE ROD BRACKETS RPV 1
B-N-2 B13.22 CORE SUPPORT STRUCTURE CORE SUPPORT WELD t
0
?U a-9
-ye
_.-.7_
-.,._-,,,.___--__w.
- ' }id,
I l
- Page No.
21 01/22/87 d
LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID o*
B-P RPV 1
B-P B15.10 PRESS RETAINING BOUNDARY RPV 1
B-P B15.11 PRESS RETAINING BOUNDARY l
1 0
.O i
I l
l Il O
t-a.
,'s."
- Page No.
22 01/22/87
(^') 1 LIMERICK GENERATING STATION UNIT 1
'w/
AND COMMON PLANT FIRST 10-YEAR INTERVHL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID o*
F-A,B,C RPV 1
F-A,B,C FO.OO BY AZ.
MECH CONNECTION TO BLDG SKIRT BOLTING TO BASE PLATE RPV 1
F-A,B,C FO.OO CA INTERMEDIATE WELD CONNECT SKIRT KNUCKLE WELD RPV 1
F-A,B,C FO.OO CB INTERMEDIATE WELD CONNECT SKIRT KNUCKLE WELD RPV 1
F-A,B,C FO.OO CC INTERMEDIATE WELD CONNECT SKIRT KNUCKLE WELD RPV 1
F-A,B.C FO.OO CD INTERMEDIATE WELD CONNECT i
F-A,B,C FO.OO CE INTERMEDIATE WELD CONNECT SKIRT KNUCKLE WELD RPV 1
F-A,B,C FO.OO CF INTERMEDIATE WELD CONNECT SKIRT KNUCKLE WELD RPV 1
F-A,B,C FO.OO CH INTERMEDIATE WELD CONNECT SKIRT WELD RPV 1
F-A,B,C FO.OO CJ INTERMEDIATE WELD COHNECT SKIRT WELD RPV 1
F-A,B,C FO.OO CK INTERMEDIATE WELD CONNECT BASE PLATE WELD RPV 1
F-A,B,C FO.OO CM INTERMEDIATE WELD CONNECT BASE PLATE WELD RPV 1
F-A,B,C FO.OO CN INTERMEDIATE WELD CONNECT BASE PLATE WELD RPV 1
F-A,B,C FO.OO CP INTERMEDIATE WELD CONNECT BASE PLATE WELD RPV 1
F-A,B,C FO.OO CR INTERMEDIATE WELD CONNECT BASE PLATE WELD RPV 1
F-A,B,C FO.OO CS INTERMEDIATE WELD CONNECT
~
BASE PLATE WELD 1
___,m
?Page No.
23 LIMERICK GENERATING STATION UNIT 1 AND COMMON PLANT FIRST 10-YEAR INTERVAL INSERVICE INSPECTION EXAMINATION PLAN SYSTEM ASME CODE CODE COMPONENT DESCRIPTION CLASS CAT ITEM ID RPV 1
F-A,B,C FO.00 CT INTERMEDIATE WELD CONNECT SKIRT TO BASE PLATE WELD RPV-1 F-A,B,C FO.00 CW INTERMEDIATE WELD CONNECT SKIRT TO KNUCKLE WELD O
.lO x
t
o P:g> No.
1 TABLE 1 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 COMMON p
NUCLEAR CLASS 1 & 2 PIPE WELDS j
Q Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM
- FEEDWATER FWA 941A 16" VALVE HV-1994 TO
+
NA FWA c53 VALVE HV-1F032A TO
+
NA FWA 0'M 24" PIPE TO TEE
+
NA FWB 939A 16" VALVE HV-199B
+
NA FWB 040 VALVE HV-1F032B TO
+
NA FWB 041 24" PIPE TO TEE
+
NA
CSA 001 10" PIPE TO 10"X12" B-J B9.11 1
CSA 001A 10" PIPE TO PIPE B-J B9.11 1
CSA 001ALD 10" PIPE SEAM B-J B9.12 1
CSA 001ALU 10" PIPE SEAM B-J 99.12 CSA 001LD 10" PIPE SEAM B-J B9.12 1
CSA 001LU 12"X10" REDUCER SEAM B-J B9.12 j
1 CSA 002 10"X12" REDUCER TO B-J B9.11 i
1 CSA 002LD 10"X12" REDUCER SEAM B-J B9.'12 1
CSA 002LU MAX 12" ELBOW SEAM, B-J B9.12 l
1 CSA 002LU MIN 12" ELBOW SEAM, B-J B9.12 1
CSA 003 12" ELBOW TO PIPE B-J 89.11 0
1 CSA 003LD MAX 12" ELBOW SEAM, B-J 99.12 1
CSA 003LD MIN 12" ELBOW SEAM, B-J B9.12 1
CSA 003LU 12" PIPE SEAM B-J B9.12 1
CSA 008A 12" ELBOW TO PIPE, B-F B5.130 1
CSA 008ALDMAX 12" ELBOW SEAM, B-J B9.12 1
CSA 008ALDMIN 12" ELBOW SEAM, B-J 89.12 1
CSA 013 12" PIPE TO PIPE, B-F B5.130 1
CSA 015 12" FL. HD.(X-16A)TO B-F B5.130 1
CSB 001 10" PIPE TO 12"X10" B-J 99.11 1
CSB 001A 10" PIPE TO PIPE B-J 99.11 1
CSB 001ALD 10" PIPE SEAM B-J B9.12 1
CSB 001ALU 10" PIPE SEAM B-J B9.12 1
CSB 001LD 10" PIPE SEAM B-J 99.12 1
CSB 001LU 12"X10" REDUCER B-J B9.12 1
CSB 002 12"X10" REDUCER TO B-J B9.11 1
CSB 002LD 12"X10" REDUCER SEAM B-J B9.12 1
CSB 002LU MAX 12" ELBOW SEAM, B-J B9.12 1
CSB 002LU MIN 12" ELBOW SEAM, B-J B9.12 1
CSB 003 12" ELBOW TO PIPE B-J B9.11 1
CSB 003LD MAX 12" ELBOW SEPM, B-J B9.12 1
CSB 003LD MIN 12" ELBOW SEAM, B-J B9.12 1
CSB 003LU 12" PIPE SEAM B-J B9.12 1
CSB 008A 12" ELBOW TO PIPE, B-F B5.130 1
CSB 008ALDMAX 12" ELBOW SEAM, B-J B9.12 1
CSS 908ALDMIN 12" ELBOW SEAM, B-J B9.12 1
CSB 013 12" PIPE TO PIPE, B-F B5.130 0
1
P:ga No.
2 TABLE 1 91/29/87 i
LIMERICM GENERATING STATION j
UNIT 1 & COMMON A
NUCLEAR CLASS 1 & 2 PIPE WELDS Q
Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM
\\
FWA 804 12" PIPE TO ELBOW B-J B9.11 l
1 FWA 905 12" ELBOW TO PIPE B-J 99.11 1
FWA 912 12" PIPE TO ELBOW B-J B9.11 1
FWA 013 12" ELBOW TO PIPE B-J B9.11 1
FWA 827 12" PIPE TO B-J 89.11 1
FWA 828 24"X24"X12" TEE TO B-J 39.11 1
FWA 029 24" ELBOW TO PIPE B-J B9.11 l
1 FWA 029A 24" PIPE TO 24"X4" B-J B9.31 1
FWA 032 24" ELBOW TO VALVE B-J B9.11 1
FWA 033 24" VALVE 1F010A TO B-J+
B9.11 1
FWA 034 24" FLUED HD. (X-9A)
B-J+
B9.11 1
FWB 012 12" ELBOW TO PIPE B-J B9.11 1
FWB 018 12" ELBOW TO PIPE B-J B9.11 1
FWB 020 12" PIPE TO ELBOW B-J 89.11 1
FWB 823 12" ELBOW TO PIPE B-J 99.11 1
FWB 824 12" PIPE TO B-J 99.11 1
FWB 825 24"X24"X12" TEE TO B-J B9.11 1
1 FWB 930 24" VALVE 1F010B TO B-J+
89.11 1
FWB 831 24" FLUED HD. (X-9B)
B-J+
89.11 O
.. HPCI 1
HP 013 IS" PIPE TO TEE B-J+
99.11 1
HP 013A 10" TEE TO BLIND B-J+
B9.11 l
1 HP 014 TEE TO PIPE B-J+
B9.11 1
HP 815 18" PIPE TO ELBOW B-J+
89.11 1
HP 016 18" ELB0ll TO PIPE B-J+
B9.11 l
1 HP 017 10" PIPE TO VALVE B-J+
B9.11 1
HP 818 18" VALVE HV-1F002 B-J+
B9.11 1
HP 919 19" El. BOW TO PIPE B-J+
99.11 1
HP 829 10" PIPE TO FLUED B-J+
B9.11 1
HP 821 10" FLUED HD. (X-11)
B-J+
99.11
B-J+
89.11 1
MSA 921 26" ELBOW TO VALVE B-J+
89.11 1
MSA E22 26" VALVE HV-1F822A B-J+
99.11 1
MSA 923R 26" FLUED HD. (X-7A)
B-J+
89.11 l
1 MSB 804 26" PIPE TO 26"X8" B-J B9.31 l
1 MSB 007 26" PIPE TO 26"X8" B-J B9.31 1
MSB 009A 26" PIPE TO 26"X3" B-J B9.32 1
MSB 013 26" PIPE TO 26"X8" B-J B9.31 1
B-J+
99.11 1
MSB 023 26" ELBOW TO VALVE B-J+
B9.11 1
MSB 024 26" VALVE HV-1F022B B-J+
B9.11 1
MSB 025 26" FLUED HD. (X-7B)
B-J+
B9.11 1
MSC 010 26" PIPE TO E6"X8" B-J B9.31 O
+
_s m.
-, -~ --.._ -,- _ - -.
1 P:ge No.
3 TABLE 1 91/20/87 LIMERICK GENERATING STATION UNIT 1 & C0f910N NUCLEAR CLASS 1 & 2 PIPE WELDS s
Selected for Examination - First Interval j
l SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM i
1 MSC 011 26"X8" SWEEPOLET TO B-J 99.11 1
MSC 012 8" PIPE TO FLANGE B-J 89.11 1
MSC 017 26"X8" SWEEPOLET TO B-J B9.11 1
MSC 020 26" PIPE TO ELBOW B-J+
B9.11 1
MSC 021 26" ELBOW TO VALVE B-J+
B9.11 1
MSC 022 26" VALVE HV-1F022C B-J+
B9.11 1
MSC 023 26" FLUED HEAD (X-7C)
B-J+
89.11 1
MSD 007 26" PIPE TO 26"X8" B-J B9.31 1
MSD 008 26"X8" SWEEPOLET TO B-J B9.11 1
MSD 020 26" PIPE (FE 1N054)
B-J+
B9.11 1
MSD 021 26" ELBOW TO VALVE B-J+
89.11 1
MSD 022 26" VALVE HV-1F022D B-J+
B9.11 1
MSD 023 26" FLUED HD. (X-7D)
B-J+
B9.11
- RCIC 1
RC 001 4"X3" REDUCER TO 4" B-J 99.11 1
RC 002 4" PIPE TO ELBOW B-J E9.~11 1
RC 012 4" PIPE TO FE 1N016, B-F B5.130 1
RC 013 4" FE IN016 TO PIPE, B-F B5.130 1
RC 014 4" PIPE TO ELBOW B-J 89.11 0-1 RC 015 4" ELBOW TO PIPE B-J 99.11 1
RC 125 3" ELBOW TO PIPE B-J+
B9.21 1
RC 126 3" PIPE TO VALVE B-J+
B9.21 1
RC 127 3" VALVE HV-1F007 TO B-J+
B9.21 1
RC 128 3" PIPE TO ELBOW B-J+
B9.21 1
RC 129 3" ELBOW TO PIPE B-J+
B9.21 1
RC 130 3" PIPE TO FLUED B-J+
99.21 1
RC 131 Y FLUED HEAD (X-10)
B-J+
89.21
- RHR 1
RH 003 20" PIPE TD 20"X6" B-J 99.31 1
RH 004 20" PIPE TO VALVE B-J B9.11 1
RH 004LU 20" PIPE SEAM B-J B9.12 1
RH 005 20" VALVE 1F077 B-J 99.11 1
RH 005LD MAX 20" ELBOW SEAM, B-J 89.12 1
RH 005LD MIN 20" ELBOW SEAM, B-J 99.12 1
RH 007 20" PIPE TO VALVE B-J 99.11 1
RH 007LU 20" PIPE SEAM B-J B9.12 1
RH 008 20" VALVE HV-1F009 B-J B9.11 1
RH 013 20" PIPE TO PIPE B-J B9.11 1
RH 015 20" FLUED HD. (X-12)
B-J 99.11 1
RHA 001 12" PIPE TO ELBOW B-J 99.11 1
RHA 001A 12" PIPE TO PIPE B-J B9.11 1
RHA 001ALD 12" PIPE SEAM B-J B9.12 1
RHA 001ALU 12" PIPE SEAM B-J B9.12 1
RHA 001LD 12" PIPE SEAM B-J B9.12 1
RHA 001LU MAX 12" ELBOW SEAM, B-J B9.12
+
c--
,--.er.-.-
y w-
,,-,--ev,-
e-
- -' - ' -=-
---e
+-+-----w
--e
I P:ge No.
4 TABLE 1 2
01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMON
- (.x NUCLEAR CLASS 1 & 2 PIPE WELDS Selected for Examination - First Interval i
SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM
\\
i 1
RHA Se1LU MIN 12" ELBOW SEAM, B-J B9.12 1
RHA 002 12" ELBOW TO VALVE B-J 89.11 1
RHA 002LD MAX 12" ELBOW SEAM, B-J 99.12 1
RHA 002LD MIN 12" ELBOW SEAM, B-J B9.12 1
RHA 003 12" VALVE 1F065A TO B-J 89.11 1
RHA 003LU 12" PIPE SEAM B-J B9.12 1
RHA 004 12" PIPE TO ELBOW B-J B9.11 1
RHA 004LD 12" PIPE SEAM B-J B9.12 1
RHA 004LU MAX 12" ELBOW SEAM, B-J B9.12 1
RHA 004LU MIN 12" ELBOW SEAM, B-J B9.12 1
RHA 005 12" ELBOW TO PIPE B-J B9.11 1
RHA 005A 12" PIPE TO PIPE, B-F B5.130 1
RHA 005ALD 12" PIPE SEAM B-J 99.12 1
RHA 005LD MAX 12" ELBOW SEAM, B-J B9.12 1
RHA 005LD MIN 12" ELBOW SEAM, B-J B9.12 1
RHA 005LU 12" PIPE SEAM B-J 99.12 1
RHA 012 12" PIPE TO FLUED HD.
B-F
~ "B5.'130 1
RHA 013 12" FL. HD.(X-45A)TO B-F B5.130 1
RHA 175A 6" FLANGE TO ELBOW B-J 89.11 1
RHA 175B 6" PIPE TO PIPE, B-F B5.130 1
RHA 175C 6" PIPE TO ELBOW B-J B9.11 0
1 RHA 176 6" ELBOW TO PIPE B-J B9.11 1
RHA 177 6" PIPE TO VALVE B-J B9.11 1
RHA 178A 6" PIPE TO PIPE B-J B9.11 1
RHB 001 12" PIPE TO ELBOW B-J B9.11 1
RHB 001A 12" PIPE TO PIPE B-J B9.11 1
RHB 001ALD 12' PIPE SEAM B-J B9.12 1
RHB 001ALU 12" PIPE SEAM B-J B9.12 1
RHB 001LD 12" PIPE SEAM B-J B9.12 1
RHB 001LU MAX 12" ELBOW SEAM, B-J B9.12 1
NHB 001LU MIN 12" ELBOW SEAM, B-J 99.12 1
RHB 002 12" ELBOW TO VALVE B-J 99.11 1
RHB 002LD MAX 12" ELBOW SEAM, B-J B9.12 1
RHB 002LD MIN 12" ELBOW SEAM, B-J B9.12 1
RHB 003 12" VALVE 1F065B TO B-J B9.11 1
RHB 003LU 12" PIPE SEAM B-J B9.12 1
RHB 004 12" PIPE TO ELBOW B-J 89.11 1
RHB 004LD 12" PIPE SEAM B-J B9.12 1
RHB 004LU MAX 12" ELBOW SEAM, B-J 89.12 1
RHB 004LU MIN 12" ELBOW SEAM, B-J B9.12 1
1 RHB 005 ELBOW TO 12" PIPE B-J B9.11 1
RHB 005A 12" PIPE TO PIPE, B-F B5.130 1
RHB 005ALD 12" PIPE SEAM B-J B9.12 1
RHB 005LD MAX 12" ELBOW SEAM, B-J B9.12 1
RHB 005LD MIN 12" ELBOW SEAM, B-J B9.12 i
1 RHB 005LU 12" PIPE SEAM B-J B9.12 1
RHB 012 12" PIPE TO FLUED B-F B5.130 a,
P ge No.
5 TABLE 1 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 CarDION g
NUCLEAR CLASS 1 & 2 PIPE WELDS g
Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 1
RHB 013 FL. HD. (X-45B) TO B-F B5.130 1
RHC 001 12" PIPE TO ELBOW B-J 89.11 1
RHC 001A 12" PIPE TO PIPE B-J B9.11 1
RHC 001ALD 12" PIPE SEAM B-J 99.12 1
RHC 001ALU 12" PIPE SEAM B-J 39.12 1
RHC 001LD 12" PIPE SEAM B-J B9.12 1
RHC 001LU MAX 12" ELBOW SEAM, B-J 89.12 1
RHC 001LU MIN 12" ELBOW SEAM, B-J B9.12 1
RHC 002 12" ELBOW TO VALVE B-J 99.11 1
RHC 002LD MAX 12" ELBOW SEAM, B-J B9.12 1
RHC 002LD MIN 12" ELBOW SEAM, B-J B9.12 1
RHC 003 12" VALVE 1F065C TO B-J B9.11 1
RHC 003LU 12" PIPE SEAM B-J 99.12 1
RHC 004 12" PIPE TO ELBOW B-J B9.11 1
RHC 004LD 12" PIPE SEAM B-J B9.12 1
RHC 004LU MAX 12" ELBOW SEAM, B-J B9.12 1
RHC 004LU MIN 12" ELBOW SEAM, B-J 99.12 1
RHC 005 12" ELBOW TO PIPE B-J B9.11 1
RHC 0054 12" PIPE TO PIPE, B-F B5.130 1
RHC 005ALD 12" PIPE SEAM B-J B9.12 0
1 RHC 005LD MAX 12" ELBOW SEAM, B-J 99.12 1
RHC 005LD MIN 12" ELBOW SEAM, B-J 99.12 1
RHC 005LU 12" PIPE SEAM B-J B9.12 1
RHC 012 12" PIPE TO FLUED B-F B5.130 1
RHC 013 12" FL. HD.(X-45C)TO B-F B5.130 1
RHD 001 12" PIPE TO ELBOW B-J B9.11 1
RHD 001A 12" PIPE TO PIPE B-J B9.11 1
RHD 001ALD 12" PIPE SEAM B-J B9.12 1
RHD 001ALU 12" PIPE SEAM B-J B9.12 1
RHD 001LD 12" PIPE SEAM B-J B9.12 i
RHD 001LU MAX 12" ELBOW SEAM, B-J B9.12 1
RHD 001LU MIN 12" ELBOW SEAM, B-J 99.12 1
RHD 002 12" ELBOW TO VALVE B-J 89.11 l
1 RHD 002LD MAX 12" ELBOW SEAM, B-J B9.12 1
RHD 002LD MIN 12" ELBOW SEAM, B-J B9.12 1
RHD 003 1E" VALVE 1F065D TO B-J B9.11 1
RHD 003LU 12" PIPE SEAM B-J 99.12 1
RHD 004 12" PIPE TO ELBOW B-J B9.11 1
RHD 004LD 12" PIPE SEAM B-J B9.12 1
RHD 004LU MAX 12" ELBOW SEAM, B-J B9.12 1
RHD 004LU MIN 12" ELBOW SEAM, B-J B9.12 1
RHD 005 12" ELBOW TO 12" B-J B9.11 1
RHD 005A 12" PIPE TO PIPE, B-F B5.130 1
RHD 005ALD 12" PIPE SEAM B-J B9.12 1
RHD 005LD MAX 12" ELBOW SEAM, B-J 89.12 1
RHD 005LD M1N 12" ELBOW SEAM, B-J B9.12 1
RHD 005LU 12" PIPE SEAM B-J B9.12 j
O 1
PIge No.
6 TABLE 1 01/20/87 LIMERICK GENERATING STATION tm!T 1 4 C0peION NUCLEAR CLASS 1 & 2 PIPE WELDS Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 1
RHD 012 12" PIPE TO FLUED B-F B5.130 1
RHD 013 12" FL. HD.(X-45D)TO B-F B5.130
- RPV VENT 1
RV 003 4" TEE TO 4"X2" B-J E9.11
- RR 1
RPV N1A LD 28" PIPE SEAM B-J B9.12 1
RPV N1B LD 28" PIPE SEAM B-J B9.12 1
RPV N2A LU 12" PIPE SEAM B-J B9.12 1
RPV N2B LU 12" PIPE SEAM B-J 99.12 1
RPV N2C LU 12" PIPE SEAM B-J B9.12 1
RPV N2D LU 12" PIPE SEAM B-J B9.12 1
RPV N2E LU 12" PIPE SEAM B-J B9.12 1
RPV N2F LU 12" PIPE SEM B-J B9.12 1
RPV NES LU 12" PIPE SEAM B-J B9.12 1
RPV N2H LU 12" PIPE SEM
' B-J 99.'12 1
RPV N2J LU 12" PIPE SEAM B-J B9.12 1
RPV N2K LU 12" PIPE SEM B-J 99.12 1
RRA 024 28"X22" CROSS TO B-J B9.11 0
1 RRA 024LD 22" PIPE SEAM B-J 99.12 1
RRA 036 28"X12" REDUCER TO B-J B9.11 1
RRA 036LD 12" PIPE SEAM B-J B9.12 1
RRA 042 12" PIPE TO ELBOW B-J B9.11 l
1 RRA 942LD MAX 12" ELBOW SEAM, B-J B9.12 1
RRA 942LD MIN 12" ELBOW SEAM, B-J 99.12 1
RRA 942LU 12" PIPE SEAM B-J B9.12 1
RRA 943 12" ELBOW TO PIPE B-J B9.11 1
RRA 943LD 12" PIPE SEM B-J 89.12 1
RRA 943LU MAX 12" ELBOW SEAM, B-J 99.12 i
RRA 943LU MIN 12" ELBOW SEM, B-J 99.12 1
RRA 944 22" PIPE TO 22"X12" B-J 89.31 1
RRA 945 22"X12" SWEEPOLET TO B-J B9.11 1
RRA 945LD 12" PIPE SEM B-J 99.12 1
RRA 946 12" PIPE TO ELBOW B-J 89.11 1
RRA 946LD MAX 12" ELBOW SEAM, B-J 89.12 1
RRA 946LD MIN 12" ELIK1W SEAM, B-J 99.12
{
1 RRA 946LU 12" PIPE SEM B-J B9.12 1
RRA 947 12" ELBOW TO PIPE B-J B9.11 1
RRA 947LD 12" PIPE SEM B-J B9.12 1
RRA 947LU MAX 12" ELBOW SEAM, B-J B9.12 1
RRA 947LU MIN 12" ELBOW SEAM, B-J 99.12 i
RRA 948 22" PIPE TO CAP B-J B9.11 1
RRA 948LU 22" PIPE SEM B-J B9.12 1
RRB 004 28"X28"X20" TEE TO B-J B9.11 1
RRB 004A 28" PIPE TO PIPE B-J B9.11 1
RRB 004ALD 28" PIPE SEAM B-J 99.12 O
4
P g3 No.
7 TABLE 1 01/20/87 LIMERICK GENERATING STATION LDl!T 1 4 COP 904 Select or E nation -
s erval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 1
RRB 004ALU 28" PIPE SEAM B-J 89.12 1
RRB 004LD 28" PIPE SEAM B-J B9.12 1
RRB 006 28" ELBOW TO VALVE B-J B9.11 1
RRB 006LU MAX 28" ELBOW SEAM, B-J 99.12 1
RRB 006LU MIN 28" ELBOW SEAM, B-J B9.12 1
RRB 007 28" VALVE HV-1F0238 B-J B9.11 1
RRB 007A 28" PIPE TO 2" B-J B9.32 1
RRB 007LD 28" PIPE SEAM B-J B9.12 1
RRB 013 28" PUMP 1BP201 TO B-J B9.11 1
RRB 013LD 28" PIPE SEAM B-J B9.12 1
RRB 016 28" PIPE TO VALVE B-J 89.11 1
RRB 016LU 28" PIPE SEAM B-J 89.12 1
RRB 028 22" PIPE TO 22"X12" B-J B9.31 1
RRB 029 22"X12" SWEEPOLET TO B-J B9.11 1
RRB 029LD 12" PIPE SEAM B-J B9.12 1
RRB 032 22" PIPE TO CAP B-J B9.11 1
RRB 932LU 22" PIPE SEAM B-J 99.12 1
RRB 935 12" PIPE TO ELBOW B-J 99.11 1
RRB 935LD MAX 12" ELBOW SEAM, B-J B9.12 1
RRB 935LD MIN 12" ELBOW SEAM, B-J B9.12 1
RRB 935LU 12" PIPE SEAM B-J B9.12 O.
1 RRB 936 12" ELBOW TO PIPE B-J B9.11 1
RRB 936LD 12" PIPE SEAM B-J B9.12 1
RRB 936LU MAX 12" ELBOW SEAM, B-J B9.12 1
RRB 036LU MIN 12" ELBOW SEAM, B-J B9.12 1
RRB 049 2" ELBOW TO PIPE B-J 89.21 1
RRB 051 2" PIPE TO PIPE B-J 99.21 1
RRB 052 2" PIPE TO PIPE B-J B9.21 1
RRB 053 2" PIPE TO VALVE B-J B9. 40 1
RRB 054 2" VALVE 1F051B TO B-J B9. 40
- RWCU 1
RW 004 6" PIPE TO VALVE B-J B9.11 1
RW 0054 6" PIPE TO VALVE B-J B9.11 1
RW 006 6" PIPE TO ELBOW B-J 89.11 1
RW 008 6" PIPE TO ELBOW B-J 89.11 1
RW 012 6" PIPE TO ELBOW B-J+
B9.11 l
1 RW 013 6" ELBOW TO PIPE B-J+
B9.11 1
RW 014 6" PIPE TO ELBOW B-J+
B9.11 1
RW 015 6" ELBOW TO PIPE B-J+
B9.11 1
RW 016 6" PIPE TO VALVE B-J+
B9.11 1
RW 017 6" VALVE HV-1F001 TO B-J+
B9.11 1
RW 018 6" PIPE TO FLUED B-J+
B9.11 1
RW 019 6" FLUED HEAD (X-14)
B-J+
B9.11 1
RW 022 24"X4" SWEEPOLET TO B-J B9.11 1
RW 045 4" PIPE TO VALVE B-J B9.11 1
RW 047R 4" ELBOW TO PIPE B-J B9.11 O
i.
'l
,-------.-.....,__,c--
---.-m
P!g3 No.
8 TABLE 1 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 COMMON NUCLEAR CLASS 1 & 2 PIPE WELDS Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 1
RW 085 2 1/2" PIPE TO ELBOW B-J B9.21 1
RW 086 2 1/2" ELBOW TO PIPE B-J 89.21 1
RW 088 2 1/2" TEE TO B-J B9.21 1
RW 090 2" PIPE TO ELBOW B-J B9.21 1
RW 091 2" PIPE TO ELBOW B-J B9.21 l
1 RW 894 2" VALVE 1F029 TO B-J 89.48 1
RW 095 2" PIPE TO VALVE B-J B9. 48 1
RW 097 2 1/2" PIPE TO B-J B9.21 1
RW 098 2 1/2"X4" REDUCER B-J B9.11 1
RW 103A 4" PIPE TO 2" B-J B9.32 1
RW 107 4" PIPE TO 4"X2" B-J B9.32 1
RW 114 2" PIPE TO ELBOW B-J B9.21 1
RW 116 2" PIPE TO VALVE B-J B9.21 1
RW 118 2" PIPE TO ELBOW B-J B9.21 1
RW 120 2" PIPE TO 4"X2" B-J B9.21 1
RW 123 4" PIPE TO FE JNO38 B-J 89.11 1
RW 124 4" FLOW ELEPENT B-J 89.11 1
RW 137 4" PIPE TO 4"X6" B-J 89.11
- SLC O
1 SC 002 2" PIPE TO B-J B9.21 1
SC 016 2" PIPE TO B-J 99.48 1
SC 017 2"X2"X3/4" TEE TO 2" B-J 89.48 1
SC 018 2" PIPE TO VALVE B-J 89.40 1
SC 026A 2" PIPE TO COUPLING B-J B9.48 1
SC 026B 2" PIPE TO COUPLING B-J 99.48 1
SC 031 2" PIPE TO ELBOW B-J 89.40 1
SC 032 2" ELBOW TO PIPE B-J B9. 48 1
SC 033 2" PIPE TO ELBOW B-J B9. 48 1
SC 034 2" ELBOW TO PIPE B-J B9.48 1
SC 039 2" PIPE TO ELBOW B-J 89.48 1
SC 045R 2" PIPE TO VALVE B-J B9.48 1
SC 046R 2" VALVE 1927 TO B-J 89.40 1
SC 048 2" ELBOW TO PIPE B-J 89.48 1
SC 049 2" PIPE TO ELBOW
.B-J 99.48 1
SC 054 2" ELBOW TO PIPE
'B-J 99.48
. -J 89.48 l
1 SC 055 2" PIPE TO 12"X2" B
1 1
CSA 018 12" ELBOW TO VALVE C-F C5.21 2
CSA 020 14"X12" REDUCER TO C-F C5.21 2
CSA 029 14" FLANGE C-F C5.11 2
CSA 942 12" VALVE 1F020A TO C-F C5.11 2
CSA 065 16" PIPE TO VALVE C-F C5.11 2
CSA 073 12" PIPE TO 12"X10" C-F C5.11 2
CSA 078 16" FLANGE TO ELBOW C-F C5.11 2
CSA 098D FLANGE (F0 11541) TO C-F C5.11 0
. _ _ _ _ _ _..,.,,, _,,,,. _,.. _ _ _ -... _ _ _ _ _ ~., _ _ _,
P:ge No.
9 TABLF 1 01/20/87 LIMERICK GENERATING STATION Ltd!T 1 & C0peION Select frEa ati n -
s erval j
SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 2
CSA 100 10" ELBOW TO VALVE C-F C5.11 2
CSB 023 12" VALVE HV-1F004B C-F C5.21 2
CSB 037 14" ELBOW TO PIPE C-F C5.11 2
CSB 938R 14" PIPE TO C-F C5.11 2
CSB 046 12" ELBOW TO PIPE C-F C5.11 2
CSB 058R 16"X16"X14" TEE TO C-F C5.11 2
CSB 060 16"X16"X14 TEE TO C-F C5.11 2
CSB 072 14"X14"X12" TEE TO C-F C5.11 2
CSB 081 16" FLANGE TO PIPE C-F C5.11 2
CSB 090 16" ELBOW TO PIPE C-F C5.11 2
CSB 106A 10" VLV HV-1F015B TO C-F C5.11 2
CSB 107 12" TEE TO PIPE C-F C5.21 2
CSB 109 12" VALVE 1959 TO C-F C5.21 2
CSC 001 6" FLUED HEAD C-F C5.11 2
CSC 002 6" PIPE TO VALVE C-F C5.11 2
CSC 006R 6" ELBOW TO PIPE C-F C5.I1
- CRD HYD 2
RDA 001 8" CAP TO PIPE C-F C!'.11 2
RDA 002 8" PIPE TO 8" TEE C-F C5.11 2
RDA 021 8" 45 degree ELBOW C-F C5.11 2
RDA 023 8" 45 degree ELBOW C-F C5.11 s
2 RDA 026 8" TEE TO PIPE C-F C5.11 2
RDA 029 8" PIPE TO FLANGE C-F C5.11 2
RDB 005 8" TEE TO 10" X C-F C5.11 2
RDB 006 10"X8" ECCENTRIC C-F C5.21 2
RDB 007 10" PIPE TO ELBOW C-F C5.21 2
RDB 009 10" PIPE TO CAP C-F C5.21 2
RDB ele 8" TEE TO PIPE C-F C5.11 2
RDB 017 8" PIPE TO 8" TEE C-F C5.11 2
RDB 019 8" TEE TO PIPE C-F C5.11 t
FWA e35 VALVE HV-1F074A TO C-F+
C5.21 2
FWA 036 24" PIPE TO C-F+
C5.21 2
FWA 037 24"X24"X16" TEE TO C-F+
C5.21 2
FWA 038 24"X24"X16" TEE TO C-F+
C5.21 2
FWA 039 16" ELBOW TO ELBOW C-F+
C5.21 2
FWA 940 16" ELBOW TO PIPE C-F+
C5.21 2
FWA 941 16" PIPE TO VALVE C-F+
C5.21 2
FWA 944 8" VALVE 1958 TO C-F+
C5.21 2
FWA 945 8" 20 degree ELBOW C-F+
C5.21 2
FWA 945A 8" PIPE TO 20 degree C-F+
C5.21 2
FWA 946R 8" ELBOW TO PIPE C-F+
C5.21 2
FWA 047 8" PIPE TO ELBOW C-F+
C5.21 2
FWA 948 8" 45 degree ELBOW C-F+
C5.21 l
2 FWA 049 8" PIPE TO 45 degree C-F+
C5.21
' O
P:g] No, le TABLE 1 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON j
f" NUCLEAR CLASS 1 & 2 PIPE WELDS 1
(,)g e
Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 1
l 2
FWA 949A 8" 45 degree ELBOW C-F+
C5.21 2
FWA 950 8" PIPE TO 45 degree C-F+
C5.21 1
2 FWA 951 24"X8" SWEEP 0LET TO C-F+
C5.21 2
FWA 052 24" PIPE TO 24"X8" C-F+
C5.31 2
FWB 032 24" VAVLE HV-1F074B C-F+
C5.21 2
FWB 033 24" PIPE TO 24"X6" C-F+
C5.31 2
FWB 034 24" PIPE TO TEE C-F+
C5.21 2
FWB 035 24"X24"X16" TEE TO C-F+
C5.21 2
FWB 036 16" TEE TO ELBOW C-F+
C5.21 2
FWB 037 16" ELBOW TO ELBOW C-F+
C5.21 2
FWB 038 16" ELBOW TO PIPE C-F+
C5.21 2
FWB 039 16" PIPE TO VALVE C-F+
C5.21
- HPCI 2
HP 022 10" VALVE HV-1F003 C-F+
C5.21 2
HP 023 10"X12" REDUCER TO C-F+
C5.21 2
HP 024 12" ELBOW TO PIPE C-F+
C5.21 2
HP 024AR2 12" PTPE TO PIPE C-F+
C5.21 2
HP 025R1 12" PIPE TO ELBOW C-F+
C5.21 2
HP 026 12" ELBOW TO PIPE C-F+
C5.21
(~'s 2
HP 027 12" PIPE TO ELBOW C-F+
C5.21 L/
2 HP 028 12" ELBOW TO PIPE C-F C5.21 2
HP 841 12" PIPE TO ELBOW C-F C5.21 2
HP 048 12" ELBOW TO PIPE C-F C3.21 2
HP 057 12" PIPE TO 12"X10" C-F C5.12 2
HP 060 20"X20"X18" TEE TO C-F C5.11 2
HP 061 20" PIPE TO CAP C-F C5.11 2
HP 076 20"X20"X16" TEE TO C-F-C5.11 2
HP 081 20" PIPE TO 20"X12" C-F C5.11 2
HP 082 20"X12" REDUCER TO C-F C5.11 2
HP 086 12" ELBOW TO VALVE C-F C5.11 2
HP 092 12" VALVE HV-1F006 C-F C5.12 2
HP 093 12"X14" REDUCER TO C-F C5.12 2
HP 108 14" PIPE TO EL90W C-F C5.12 2
HP 109 14" ELBOW TO PIPE C-F C5.12 2
HP 111 14" ELBOW TO PIPE C-F C5.12
[
2 HP 112 14" PIPE TO C-F C5.12 l
2 HP 114B 10" ELBOW TO FLANGE C-F C5.12 l
2 HP 114R1 10" FLANGE C-F C5.12 2
HP 117 14" TEE TO VALVE C-F C5.12 2
HP 120 14" VALVE 1F005 TO C-F C5.12 2
HP 121 14" PIPE TO ELBOW C-F C5.12 2
HP 136 14" ELBOW TO 14"X10" C-F C5.12 2
HP 140 12" ELBOW TO PIPE C-F C5.11 2
HP 142 12" ELBOW TO FLANGE C-F C5.11 2
HP 150 8" ELBOW TO PIPE C-F C5.12 2
HP 151 8" PIPE TO ELBOW C-F C5,12 l
P;ge No.
11 TABLE 1 81/29/87 LIMERICK GENERATING STATION UNIT 1 & C0 pet 0N I
Select for E a nati n -
s erval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM l
2 HP 154 8" ELBOW TO PIPE C-F C5.12 2
HP 155 8" PIPE TO ELBOW C-F C5.12 2
HP 157 8" PIPE TO ELBOW C-F C5.12 2
HP 158 8" ELBOW TO PIPE C-F C5.12 2
HP 168 8" ELBOW TO PIPE C-F C5.12 2
HP 161 8" PIPE TO ELBOW C-F C5.12 2
HP 162 8" ELBOW TO PIPE C-F C5.12 2
HP 1634 8" PIPE TO ELBOW C-F C5.12 2
HP 169A 8" PIPE TO '5 degree C-F C5.12 2
HP 171 8" PIPE TO 45 degree C-F C5.12 2
HP 181 10" PIPE TO VALVE C-F C5.21
MS 001 26"X26"X14" TEE TO C-F C5.12 2
MS 002 14" PIPE TO ELBOW C-F C5.12 2
MS 983 14" ELBOW TO PIPE C-F C5.12 2
MS 005 14" ELBOW TO PIPE C-F C5.12 2
MS 806 14" PIPE TO 18"X14" C-F C5.12 2
MS 907 18"X14" REDUCER TO C-F C5.12 2
MS 908 26"X26"X14" TEE TO C-F C5.12 2
MS 909 14" PIPE TO ELBOW C-F C5.12 2
MS 810 14" ELBOW TO PIPE C-F C5.12 2
MS 011 14" PIPE TO C-F C5.12 2
MS 012 18"X18"X14" TEE TO C-F C5.12 2
MS 813 18" PIPE TD TURBINE C-F C5.12 2
MS 914 26"X26"X14" TEE TO C-F C5.12 2
MS 815 14" PIPE TO ELBOW C-F C5.12 2
MS 916 14" ELBOW TO PIPE' C-F C5.12 2
MS 917 14" PIPE TO ELBOW C-F C5.12 2
MS 018 14" ELBOW TO PIPE C-F C5.12 2
MS 919 14" PIPE TO 18"X14" C-F C5.12 2
MS 829 18"X14" REDUCER TO C-F C5.12 2
MS 921 26"X26"X14" TEE TO C-F C5.12 2
MS 822 14" PIPE TO ELBOW C-F C5.21 2
MS 823 14" ELBOW TO PIPE C-F C5.21 2
MS 924 14" PIPE TO C-F C5.21 2
MS 825 18"X18"X14" TEE TO C-F C5.21 2
MS 832 18" PIPE TO ELBOW C-F C5.12 2
MSA 024 26' VALVE HV-1F0284 C-F+
C5.21 2
MSA 025 26" PIPE TO ELBOW C-F+
C5.21 2
MSA 925LD MAX 26" ELBOW SEAN, C-F+
C5.22 2
MSA 025LD MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSA 026 26" ELBOW TO PIPE C-F+
C5.29 2
MSA 026LU MAX 26" ELBOW SEAM, C-F+
C5.28 2
MSA 026LU MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSA 828 26" ELBOW TO PIPE C-F C5.21 2
MSA 832 26" ELBOW TO PIPE C-F C5.21 0
1 P!g) No.
12 TABLE 1 31/20/87 LIMERICK GENERATING STATION UNIT 1 8 COMMON g
NUCLEAR CLASS 1 & 2 PIPE WELDS
[j Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM
- _ =
2 MSA 032LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSA 032LU MIN 26" ELBOW SEAM, C-F C5.22 2
MSA 033 26" PIPE TO C-F C5.21 2
MSA 033LD 26"X26"X14" TEE SEAM C-F C5.22 2
MSA 036 26" PIPE TO 6" C-F C5.31 2
MSA 037 6" SWEEP 0LET TO PIPE C-F C5.11 2
MSA 038 6" PIPE TO CAP C-F C5.11 2
MSA 039 26" PIPE TO VALVE C-F C5.21 2
MSB 026 26" VALVE HV-1F028B C-F+
C5.21 2
MSB 027 26" PIPE TO ELBOW C-F+
C5.21 2
MSB 027LD MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSB 027LD MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSB 028 26" ELBOW TO PIPE C-F+
C5.21 2
MSB 028LU MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSB 028LU MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSB 931 26" PIPE TO ELBOW C-F C5.21 2
MSB 931LD MAX 26" ELBOW SEAM, C-F C5.22 2
MSB 931LD MIN 26" ELBOW SEAM, C-F C5.22 2
MSB 934 26" PIPE TO ELBOW C-F C5.21 2
MSB 934LD MAX 26" ELBOW SEAM, C-F C5.22 2
MSB 034LD MIN 26" ELBOW SEAM, C-F C5.22 O.
2 MSB 935 26" ELBOW TO PIPE C-F C5.21 2
MSB 035LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSB 035LU MIN 26" ELBOW SEAM, C-F C5.22 2
MSB 036 26" PIPE TO C-F C5.21 2
MSB 936LD 26"X26"X14" TEE SEAM C-F C5.22 2
MSB 938 26" PIPE TO ELBOW C-F C5.21 2
MSB 938LD MAX 26" ELBOW SEAM, C-F C5.22 2
MSB 038LD MIN 26" ELBOW SEAM, C-F C5.22 2
MSB 040 26" PIPE TO 26"X6" C-F C5.31 2
MSB 041 26"X6" SWEEPOLET TO C-F C5.11 2
MSB 042 6" PIPE TO CAP C-F C5.11 2
MSB 043 26" PIPE TO VALVE C-F C5.21 2
MSB 044 26"X6" SWEEPOLET TO C-F C5.11 2
MSC 024 26" VALVE HV-1F028C C-F+
C5.21 2
MSC 025 26" PIPE TO ELBOW C-F+
C5.21 2
MSC 025LD MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSC 025LD MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSC 026 26" ELBOW TO PIPE C-F+
C5.21 2
MSC 026LU MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSC 026LU MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSC 029R 26" PIPE TO ELBOW C-F C5.21 2
MSC 029RLDMAX 26" ELDOW SEAM, C-F C5.22 2
MSC 029RLDMIN 26" ELBOW SEAM, C-F C5.22 2
MSC 030 26" ELBOW TO PIPE C-F C5.21 2
MSC 030LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSC 030LU MIN 26" ELBOW SEAM, C-F C5.22 0
1 l
P;ge No.
13 TABLE 1 01/20/87 LIMERICK GENERATING STATION j
UNIT 1 & COMMON 1
NUCLEAR CLASS 1 & 2 PIPE WELD 6 Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM
\\
2 MSC 032 26" ELBOW TO PIPE C-F C5.21 2
MSC 032LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSC 032LU MIN 26" ELBOW SEAM, C-F C5.22 2
MSC 033 26" PIPE TO C-F C5.21 2
MSC 033LD 26"X26"X14" TEE SEAM C-F C5.22 2
MSC 036 26" PIPE TO 26"X8" C-F C5.31 2
MSC 038 8" PIPE TO VALVE C-F C5.11 2
MSC 040 26"X6" SWEEPOLET TO C-F C5.11 2
MSC 041 6" PIPE TO CAPE C-F C5.11 2
MSC 042 26" PIPE TO VALVE C-F C5.21 2
MSD 024 26" VALVE HV-1F028D C-F+
C5.21 2
MSD 024A 26" PIPE TO PIPE C-F+
C5.21 2
MSD 025 26" PIPE TO ELBOW C-F+
C5.21 2
MSD 025LD MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSD 025LD MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSD 026 26" ELBOW TO PIPE C-F+
C5.21 2
MSD 026LU MAX 26" ELBOW SEAM, C-F+
C5.22 2
MSD 026LU MIN 26" ELBOW SEAM, C-F+
C5.22 2
MSD 029 26" PIPE TO ELBOW C-F C5.21 2
MSD 029LD MAX 26" ELBOW SEAM, C-F C5.22 2
MSD 029LD MIN 26" ELBOW SEAM, C-F C5.22 2
MSD 032 26" ELBOW TO PIPE C-F C5.21 2
MSD 032LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSD 032LU MIN 26" ELBOW SEAM, C-F C5.22 2
MSD 033 26" PIPE TO C-F C5.21 2
MSD 033LD 26"X26"X14" TEE SEAM C-F C5.22 2
MSD 035 26" ELBOW TO PIPE C-F C5.21 2
MSD 035LU MAX 26" ELBOW SEAM, C-F C5.22 2
MSD 035LU MIN 26" ELBOW SEAM, C-F C5.22 2
MSD 036 26" PIPE TO 26"X6" C-F C5.31 2
MSD 037 26"X6" SWEEPOLET TO C-F C5.11 2
MSD 038 6" PIPE TO CAP C-F C5.11 2
MSD 039 26" PIPE TO VALVE C-F C5.21
- MSIVLC 2
ML 001 6" CAP TO PIPE C-F C5.11 2
ML 002 6" PIPE TO ELBOW C-F C5.11 2
ML 003 6" ELBOW TO PIPE C-F C5.11 2
ML 011 6" PIPE TO ELBOW C-F C5.11 2
ML 012 6" ELBOW TO PIPE C-F C5.11
- RCIC 2
RC 016A 3" VALVE HV-1F008 TO
+
NA 2
RC 017 6"X3" REDUCER TO 6" C-F+
C5.11 2
RC 018 6" ELBOW TO PIPE C-F+
C5.11 2
RC 019 6" PIPE TO ELBOW C-F+
C5.11 2
RC 020 6" ELBOW TO PIPE C-F+
C5.11 O
t l
1 P ge No.
14 TABLE 1 01/20/87 LIMERICK GEIERATING STATION UNIT 1 & C0 pet 0N -
NUCLEAR CLASS 1 & 2 PIPE WELDS o
Selected for Examination - First Interval i
S'.S NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM i
2 RC 021R 6" PIPE TO ELBOW C-F+
C5.11 2
RC 022 6" ELBOW TO PIPE C-F+
C5.11 2
RC 022A 6" PIPE TO PIPE C-F+
C5.11 2
RC 027 6" PIPE TO ELBOW C-F C5.11 2
RC 029 6" PIPE TO ELBOW C-F C5.11 2
RC 034A 6" ELBOW TO PIPE C-F C5.11 2
RC 048 6" TEE TO PIPE
'C-F C5.11 2
RC 050 6" TEE TO VALVE C-F C5.11 2
RC 053R 24"X6" SWEEPOLET TO C-F C5.21 2
RC 054R 6" PIPE TO ELBOW C-F C5.21 2
RC 055R 6" ELBOW TO PIPE C-F C5.21 2
RC 060 6" VALVE HV-1F013 TO C-F C5.21 2
RC 075 6" PIPE TO ELBOW C-F C5.21 2
RC 076 6" ELBOW TO PIPE C-F C5.21 2
RC 082 6" ELBOW TO PIPE C-F C5.21 2
RC 085 6" PIPE TO ELBOW C-F C5.21 2
RC 086 6" ELBOW TO PIPE C-F C5.21 2
RC 087 6" PIPE TO VALVE C-F C5.21 2
RC 088 6" VALVE HV-1F012 TO C-F C5.21 2
RC 089 6" PIPE TO VALVE C-F C5.21
.0 2
RC 090 6" VALVE 1F014 TO C-F C5.21 2
RC 099 6" PIPE TO PUNP C-f C5.11 2
RC 100 8" FLANGE TO C-F C5.21 2
RC 101 10" PIPE TO CAP C-F C5.11 2
RC 118 IS" PIPE TO 10"X8" C-F C5.11 2
RC 120 8" ELBOW TO VALVE C-F C5.11 2
RC 121A 8" PIPE TO PIPE C-F C5.11 2
RC 122 8" PIPE TO VALVE C-F C5.11 2
RC 123 8" VALVE HV-10F060 C-F C5.11
- RHR 2
RH 016A 20" VALVE HV-1F006 C-F C5.21 2
RH 024 24" ELBOW TO PIPE C-F C5.11 2
RH 027 24" PIPE TO C-F C5.11 2
RH 029 24"X24"X20" TEE TO C-F C5.11 2
RH 044 24" VALVE HV-1F006B C-F C5.11 2
RH 048 20" ELBOW TO PIPE C-F C5.11 2
RH 050 24"X24"X20" TEE TO C-F C5.11 2
RH 053 24"X20" REDUCER TO C-F C5.11 2
RH 068 24"X24"X20" TEE TO C-F C5.11 2
RH 073 24"X24"X16" TEE TO C-F C5.11 2
RH 074 16" PIPE TO ELBOW C-F C5.11 2
RH 078 16" PIPE TO ELBOW C-F C5.11 2
RH 088 16" PIPE TO ELBOW C-F C5.11 2
RH 089 16" ELBOW TO VALVE C-F C5.11 2
RH 106 10" PIPE TO C-F C5.21 2
RH 197A 10"X10"X8" TEE TO C-F C5.21 0
l P ge No.
15 TABLE 1 01/29/87 LIMERICK GENERATING STATION UNIT 1 & COMMON NUCLEAR CLASS 1 8 2 PIPE WELDS Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 2
RH 1979 18"X6" REDUCER TO 6" C-F C5.11 2
RH 199 6" VALVE PV-C-1F051A C-F C5.11 2
RH 110 14"X6" REDUCER TO C-F C5.11 2
RH 118 10"X19"X8" TEE TO 8" C-F C5.11 2
RH 143 18" ELBOW TO PIPE C-F C5.21 2
RH 145A 18" PIPE TO 10"X6" C-F
'C5.21 2
RH 145 18"X6" REDUCER TO 6" C-F C5.11 2
RH 149 14" PIPE TO ELBOW C-F C5.11 2
RH 158 8" ELBDW TO 8"X6" C-F C5.11 2
RH 159 8"X6" REDUCER TO 6" C-F C5.11 2
RH 165 18"X18"X18" TEE TO C-F C5.11 2
RH 166 18" ELBOW TO PIPE C-F C5.11 2
RH 172 18" CHECK VALVE C-F C5.11 2
RH 176 8" PENETRATION (X-225)
C-F C5.11 2
RH 177 8"X6" REDUCER TO 6" C-F C5.11 2
RH 178 6" VALVE HV-130 TO C-F C5.11 2
RH 195 6" PIPE TO ELBOW C-F C5.11 2
RH 196A 6" ELBOW TO PIPE C-F C5.11 2
RH 199A 6" PIPE TO ELBOW C-F C5.11 2
RH 2004 ELBOW TO 6" TEE C-F C5.11 f^
2 RH 297A 6" TEE TO PIPE C-F C5.11
\\
2 RH 219B 6" ELBOW TO VALVE C-F C5.11 2
RH 220B 6" VALVE PSV-191B TO C-F C5.11 2
RH 221A 6" FLANGE TO 10"X6" C-F C5.11 2
RHA 016R 12" ELBOW TO 18"X12" C-F C5.11 2
RHA 946 18" TEE TO PIPE C-F C5.11 2
RHA 958 18" ELBOW TO PUMP C-F C5.11 2
RHA 965A 30"X24" REDUCER TO C-F
.C5.11 2
RHA 965ALD 30"X24" REDUCER SEAM C-F C5.12 2
RHA 1994 18" PIPE TO 18" TEE C-F C5.11 2
RHA 188 18" PIPE TO 20"X18" C-F C5.11 2
RHA 119R HEAT EXCHANGER HX-C-F C5.11 2
RHA 122A 18"X6" SWEEPOLET TO C-F C5.21 2
RHA 122B 6" PIPE TO FLANGE C-F C5.21 2
RHA 123C 18" TEE TO 18" PIPE C-F C5.11 2
RHR 124 18" PIPE TO ELBOW C-F C5.11 2
RHA 132 8" PIPE TO ELBOW C-F C5.11 2
RHA 133 8" ELBOW TO VALVE C-F C5.11 2
RHA 144 16" TEE TO VALVE C-F C5.11 2
RHA 153 6" VALVE HV-1F027A C-F C5.11 2
RHA 164 18"X6" SWEEPOLET TO C-F C5.11 2
RHA 294 6" PIPE TO ELBOW C-F C5.11 2
RHA 209 6" ELBOW TO PIPE C-F C5.11 2
RHA 218 6" FLUED E AD (X-17)
C-F C5.11 2
RHA 219 6" VALVE HV-1F623 TO C-F C5.11 2
RHA 229 6" PIPE TO ELBOW, C-F C5.11 2
RHA 221 6" ELBOW TO 6"X6"X4" C-F C5.11 0
4
._m-_
P:ge No.
16 TABLE 1 01/20/87 LIMERICK GENERATING STATION IMIT 1 & COMON C)h NUCLEAR CLASS 1 & 2 PIPE WELDS Selected for Examination - First Interval SYS NAME CLASS ISI WELD COMPONENT DESCRIPT.
EXAM CAT CAT ITEM 2
RHA 223 6" PIPE TO FLANGE C-F C5.11 2
RHA 229 6" PIPE TO 18"X6" C-F C5.11 2
RHA 230A VALVE PSV-1F055A TO C-F C5.11 2
RHA 230B 10" PIPE TO FLANGE C-F C5.11 2
RHA 230C 18" FLANGE TO ELBOW C-F C5.11 2
RHA 230D 10" ELBOW TO ELBOW C-F C5.11 2
RHA 239 18" YALVE HV-1F024A C-F C5.11 2
RHA 241 18" PIPE TO C-F C5.11 2
RHB 016 12" ELBOW TO 18"X12" C-F C5.11 2
RHB 017 18"X12" REDUCER TO C-F C5.11 2
RHB 060 24"X24"X20" TEE TO C-F C5.11 2
RHB 087 18" ELBOW TO PIPE C-F C5.11 2
RHB 090 18" TEE TO PIPE C-F C5.11 2
RHB 093 18" PIPE TO 18"X8" C-F C5.31 i
2 RHB 095 18" VALVE HV-1F003B C-F C5.11 2
RHB 112A 18" PIPE TO 18"X6" C-F C5.31 2
RHB 116 18" PIPE TO VALVE C-F C5.11 2
RHB 117 18" VALVE HV-1F847B C-F C5.11 2
RHB 118 18"X8" SWEEPOLET TO C-F C5.11 2
RHB 135 16" TEE TO FLANGE C-F C5.11 0
2 RHB 152 6" PIPE TO ELBOW C-F C5.11 2
RHB 181 18" PIPE TO ELBOW C-F C5.11 2
RHB 184 18" PIPE TO VALVE C-F C5.11 l
2 RHB 195 18"X22" REDUCER TO C-F C5.11 2
RHC 021B 18" PIPE TO PIPE C-F C5.11 l
2 RHC 048 18" VALVE 1F031C TO C-F C5.11 2
RHC 062 24" PIPE TO ELBOW C-F C5.11 2
RHD 034 18" PIPE TO VALVE C-F C5.11 2
RHD 945 18" FLANGE C-F C5.11 l
2 RHD 055 18" VALVE 1F031D TO C-F C5.11 l
2 RHD 056A 18" ELBOW TO PIM C-F C5.11 2
RHD 068 30" PIPE TO FLANGE C-F C5.11
- RWCU 2
RW 020 6" VALVE HV-1F904 TO C-F+
C5.11 2
RW 021 6" PIPE TO VALVE C-F+
C5.11 3
RW 138 6" VALVE HV-1F044 TO
+
NA 3
RW 139 6" PIPE TO ELBOW
+
NA 3
RW 140 6" ELBOW TO PIPE
+
NA O
P:ge No.
1 TABLE 2 01/20/87 LIMERICK GENERATING GTATIDN UNIT 1 & COMMON NUCLEAR CLASS 1 & 2 VALVES
($.;
Selected for Examination - First Interval SYS NAME COMPONENT TYPE EXAM CATG CATG ITEM
- CORE SPRAY HV-52-108 CHECK B-M-2 B12.50 HV-52-1F005 GATE B-M-2 B12.50 HV-52-1F006A CHECK B-M-2 B12.50 HV-52-IF006B CECK B-M-2 B12.50 52-1F007A GATE B-M-2 B12.50 52-1F007B GATE B-M-2 B12.50
- FEEDWATER HV-41-1F011A GATE B-M-2 B12.50 HV-41-1F011B GATE B-M-2 B12.50 41-1F010A CHECK B-M-2 B12.50 41-1F010B CHECK B-M-2 B12.50 HV-41-1F074A CHECK B-M-2 B12.50 HV-41-1F074B CHECK B-M-2 B12.50
- HPCI HV-55-1F002 GLOBE B-M-2 B12.50 HV-55-1F003 GLOBE B-M-2 B12.50
\\
HV-41-1F022A GLOBE B-M-2 B12.58 HV-41-1F022B GLOBE B-M-2 B12.50 HV-41-1F022C GLOBE B-M-2 B12.50 HV-41-1F022D GLOBE B-M-2 B12.50 HV-41-1F028A GLOBE B-M-2 B12.58 HV-41-1F028B GLOBE B-M-2 B12.58 HV-41-1F02BC GLOBE B-M-2 B12.58 HV-41-1F0280 GLOBE B-M-2 812.58 PSV-41-1F013A RELIEF B-M-2 B12.54 PSV-41-1F0138 RELIEF B-M-2 B12.58 PSV-41-1F013C RELIEF B-M-2 B12.50 PSV-41-1F013D RELIEF B-M-2 B12. 58 PSV-41-1F013E RELIEF B-M-2 B12. 58 PSV-41-1F013F REL!EF B-M-2 B12.58 PSV-41-1F013G RELIEF B-M-2 B12.58 PSV-41-1F013H RELIEF B-M-2 B12.58 PSV-41-1F013J RELIEF B-M-2 B12.58 PSV-41-1F013K RELIEF B-M-2 B12.58 PSV-41-1F013L RELIEF B-M-2 B12.50 PSV-41-1F013M RELIEF B-M-2 B12. 58 PSV-41-1F013N RELIEF B-M-2 B12. 58 PSV-41-1F013S RELIEF B-M-2 B12.58
- RHR 51-1F019 CHECK B-M-2 B12.50 HV-51-1F041A CHECK B-M-2 B12.50 l
P!g] No.
2 TABLE 2 01/20/87 LIMERICM GENERATING STATION UNIT 1 & C0 pet 0N NUCLEAR CLASS 1 & 2 VALVES j
Selected for Examination - First Interval SYS NAME COMPONENT TYPE EXAM CATG CATG ITEM HV-51-1F041B CECK B-M-2 B12.50 HV-51-1F041C CHECK B-M-2 B12.50 HV-51-1F041D CHECK B-M-2 B12.58 HV-51-1F050A CHECK B-M-2 B12.58 HV-51-1F050B CHECK B-M-2 B12.50 51-1F0654 GATE B-M-2 B12.58 51-1FM5B GATE B-M-2 B12.58 51-1F065C GATE B-M-2 B12.50 51-1F065D GATE B-M-2 B12.58 HV-51-1F008 GATE B-M-2 B12.50 HV-51-1F009 GATE B-M-2 B12.50 HV-51-1F022 GATE B-M-2 B12.58 51-1F0604 GATE B-M-2 B12.58 51-1F060B GATE B-M-2 B12.58 51-1F077 GATE B-M-2 B12.58 HV-51-1F017A GATE B-M-2 B12.58 HV-51-1F0178 GATE B-M-2 B12.50 HV-51-1F017C GATE B-M-2 B12.58 HV-51-1F017D GATE B-M-2 B12.50 HV-51-1F015A GLOBE B-M-2 B12.58 HV-51-1F015B GLOBE B-M-2 B12.58
- RR HV-43-1F023A GATE B-M-2 B12.50 HV-43-1F023B GATE B-M-2 B12.50 HV-43-1F031A GATE B-M-2 B12.50 HV-43-1F0319 GATE B-M-2 B12.58
- RMCU HV-44-1F001 GLOBE B-M-2 B12.58 HV-44-1F004 GLOBE B-M-2 B12.58 44-1F027 GATE B-M-2 B12.58 HV-44-1F100 GATE B-M-2 B12.50 HV-C-44-1F195 GLOBE B-M-2 B12. 50 l
I i
I l
e
!O 3
i l
l
I P g2 No.
1 TABLE 3 01/22/87 LIMERICK GENERATING STATION UNIT 1 4 COMMON NUCLEAR CLASS 1 8 2 BOLTING
/~%
Selected for Examination - First Interval CD SYS NAME CLASS COMPONENT BOLTS DIA EXAM CAT CATG ITEM
_ _ = -.
- RHR:
+
RHR-HXB-A 64 1 1/8
+
+
HV-52-198-B 4
5/8 B-G-2 B7.70 1
HV-52-1F005-B 16 1 1/2 B-G-2 B7.70 1
HV-52-1F006A-B 12 1 3/4 B-G 2 B7. 70 1
HV-52-1F0068-B 12 1 3/4 B-G-2 B7. 70
41-1F010A-B 16 7/8 B-G-2 B7.70 1
41-1F010B-B 16 7/8 B-G-2 B7. 70 1
HV-41-1F074A-B 16 7/8 B-G-2 B7.70 1
HV-41-1F074B-B 16 7/8 B-G-2 B7.70
03-02-M1 12 1 3/8 B-G-2 B7.50 1
03-02-M2 12 1 3/8 B-G-2 B7.50 1
03-02-M3 12 1 3/8 B-G-2 B7. 50 1
DBA-117-El-M-1-B 4
3/4 B-G-2 B7. 50 1
DBA-117-E1-M-2-B 4
3/4 B-G-2 B7.50 1
DBA-117-E2-M-1-B 4
3/4 B-G-2 87.50 1
DBA-117-E2-M-2-B 4
3/4 B-G-2 B7.50 1
DBA-118-E1-M-1-B 4
3/4 B-G-2 B7.50 1
DBA-118-E1-M-2-B 4
3/4 B-G-2 B7. 50 1
DBA-118-E2-M-1-B 4
3/4 B-G-2 B7.*e 1
DBA-118-E2-M-2-B 4
3/4 B-G-2 B7.50 1
HV-41-1F022A-B 20 2
B-G-2 B7.70 1
HV-41-1F0228-B 20 2
B-G-2 B7. 70 1
HV-41-1F022C-8 20 2
B-G-2 87.70 1
HV-41-1F022D-B 20 2
B-G-2 B7. 70 1
HV-41-1F028A-B 20 2
B-6-2 B7.70 1
HV-41-1F028B-B 20 2
B-G-2 87.70 i
1 HV-41-1F028C-8 20 2
B-S-2 87.70 1
HV-41-1F0280-B 20 2
B-G-2 87.70 l
1 PSV-41-1F0134-B1 12 1 1/8 B-6-2 B7.70 1
PSV-41-1F0134-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F0138-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F0138-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013C-B1 12 1 1/8 B-G-2 B7. 70 1
PSV-41-1F013C-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013D-B1 12 1 1/8 B-G-2 B7. 70 1
PSV-41-1F013D-B2 12 1 3/8 B-G-2 B7. 50 1
PSV-41-1F013E-B1 12 1 1/8 B-G-2 B7. 70 j
1 PSV-41-1F013E-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013F-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F013F-B2 12 1 3/8 B-G-2 B7.50 O
e I
P:g] No.
2 TABLE'3 01/22/87 LIMERICK GENERATING STATION UNIT 1 8 COMMON NUCLEAR CLASS 1 & 2 BOLTING Selected for Examination - First Interval SYS NAME CLASS COMPONENT BOLTS DIA EXAM CAT CATG ITEM 1
PSV-41-1F013G-B1 12 1 1/8 B-G-2 B7. 79 1
PSV-41-1F013G-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013H-B1 12 1 1/8 B-G-2 B7. 70 1
PSV-41-1F013H-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013J-B1 12 1 1/8 B-G-2 B7. 78 1
PSV-41-1F013J-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013K-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F013K-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013L-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F013L-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013M-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F013M-B2 12 1 3/8 B-G-2 B7.58 1
PSV-41-1F013N-B1 12 1 1/8 B-G-2 B7.70 1
PSV-41-1F013N-B2 12 1 3/8 B-G-2 B7.50 1
PSV-41-1F013S-B1 12 1 3/8 B-G-2 B7.70 1
PSV-41-1F013S-B2 12 1 3/8 B-G-2 B7.50
- RHR 1
DCA-193-1-M-1-B 12 1 1/8 B-G-2 B7.50 1
HV-51-1F0154-B 16 1 3/8 B-G-2 B7.78 1
HV-51-1F015B-B 16 1 3/8 B-G-2 B7.78 1
HV-51-1F017A-B 16 1 1/2 B-6-2 B7.70 1
HV-51-1F017B-B 16 1 1/2 B-G-2 B7. 70 1
HV-51-1F017C-B 16 1 1/2 B-G-2 B7.78 1
HV-51-1F017D-B 16 1 1/2 B-G-2 B7.70 1
HV-51-1F041A-B 12 1 3/4 B-G-2 B7. 78 1
HV-51-1F8419-B 12 1 3/4 B-G-2 B7.70 1
HV-51-1F041C-B 12 1 3/4 B-G-2 B7. 78 1
HV-51-1F041D-B 12 1 3/4 B-G-2 B7.78 l
1 HV-51-1F0504-B 12 1 3/4 B-G-2 B7.78 1
HV-51-1F0508-B 12 1 3/4 B-G-2 B7.78
- RR 1
HV-43-1F023A-B 28 1 3/4 B-G-2 87.70 r
l 1
HV-43-1F8239-9 28 1 3/4 B-G-2 97.70 1
HV-43-1F831A-B 28 1 3/4 B-G-2 B7. 78 1
HV-43-1F031B-B 28 1 3/4 B-G-2 B7.70
- RWCU 1
DCA-181-1-M-1-B 12 1 1/8 B-G-2 B7.50 0
v a
(-
O Q
Q' 1
4 Page No.
1 TABLE 4 41/28/8T LIERICK MERATING STATION UNIT 1 & CGe10N PAJCLEAR CLASS 1 & 2 PLBIPS & EAT EXCHANGERS Selected _for Examination - First Interval SYS NAME CLASS COMPONENT WELD NO DESCRIPTION EXAM CAT CAT ITEM e*
1CP-296 CSC-P-E ELBOW TO OUTLET HEAD WELD C-6 C6.19 2
1CP-296 CSC-P-F FLANGE TO OUTLET ELBOW WELD C-G C6.10 2
1CP-296 CSC-P-8 STUFFING BOX TO OUTLET reanu WELD C-6 C6.10 se EIC 2
10P-293 RC-P-SWD1 OUTLET N0ZZLE TO CASING ELD C-G C6.19 so meg 2
1AP-292 RHA-P-E ELBOW TO OUTLET HEAD WELD C-6 C6.10 2
1AP-292 RHA-P-F FLANGE TO OUTLET ELBOW WELD C-6 C6.10 2
1AP-202 RHA-P-G STUFFING BOX TO OUTLET ELBOW WELD C-G C&.le 2
1AE-295 RHR-HXA-1 HEAD TO SHELL 4 WELD C-A C1.20 2
1AE-205 RHR-HXA-2 SHELL 4 TO SHELL 3 WELD C-A C1.10 2
1AE-295 RHR-HXA-3 SHELL 3 TO SHELL 2 WELD C-4 C1. te 2
1AE-205 RHR-HXA-4 BHELL 1 TO FLANGE ELD C-A C1.10 2
1AE-295 RHR-HXA-N3 N0ZZLE TO HEAD WELD C-8 C2.21 2
1AE-295 RHR-HXA-N3IR N0ZZLE N3 INNER RADIUS C-B C2.22 2
1AE-295 RHR-HXA-N4 N0ZZLE TO SHELL 1 WELD C-B C2.21 2
1AE-295 RHR-HXA-N41R N0ZZLE N4 INNER RADIUS C-B C2.22 s.
b
J:lxe Page No.
1 TABLE 5 01/20/87 g\\,
LI E RICK GENERATING STATION iMIT 1 4 COMMON NUCLEAR CLA6S 1, 2 8 3 INTEGRAL ATTAD00ENTS Selected for Exaeination - First Interval SYS NAE CLASS COMP HANG COMP DESC1 TYPE EXAM CATS CAT 6 ITEM 1
ee MAIN STEAM 1
APE-1MS-W C1 PIPE SUPPORT 4 LUBS B-K-1 Ble. it ee RHR 1
DCA-195-H002 P!PE SUPPORT 4 LUBS B-K-1 Ble. it
- RR 1
VRR-1RD-M B2 PIPE SUPPORT 4 LUBS B-K-1 810.10 1
VRR-1RP-H004 PUMP GUPPORT LUG B-K-1 B10.20 1
VRR-1RP-H005 PUMP S'JPPORT LUB B-K-1 B10. 20 1
VRR-1RS-HHB1 PIPE SUPPORT 4 LUGS B-K-1 810.10
GBB-112-He37 PIPE SUPPORT 4 LUGS C-C C3.20 2
GBB-112-H050 PIPE SUPPORT 16 LUGS C-C C3.20 ee CRD HYD 2
EBB-142-SH-E19 PIPE SUPPCRT 4 LUGS C-C C3.20 2
EBB-142-SH-W18 PIPE SUPPCRT 4 LUGS C-C C3.20 0
w
(
- e HPCI 2
EBB-129-H043 PIPE SUPPORT 8 LUBS C-C C3.20 2
EBS-129-H983 PIPE SUPPORT ANCH SLEEV C-C C3.20
('
2 EBB-134-H901 PIPE SUPPORT ANCH SLEEV C-C C3.20 2
HBB-198-H005 PIPE SUPPORT 8 LUBS C-C C3.20 o
.. - S.
2 EBB-196-H010 PIFI SUPFORT 8 LUBS C-C C3.20
- MSIVLC 2
HSB-154-H002 PIPE SUPPORT 8 LU68 C-C C3.20
- RCIC 2
EBB-135-H002 PIPE SUPPORT 4 LUSS C-C C3.20 2
EBB-135-H025 PIPE SUPPORT 4 LUBS C-C C3.20 2
RC-P-PS1 PUMP SUPPORT STRUCTUE C-C C3.30 se fD4R
(
2 EBS-121-H982 PIPE SUPPORT AMCH SLEEV C-C C3.20 2
800-101-H004 PIPE SUPPORT 4 LUBS C-C C3.20 2
889-1924 935 PIPE SUPPORT SLEEV C-C C3.20 2
000-111-H004 PIPE SUPPORT 4 LUBS C-C C3.30 2
688-117-H004 PIPE SUPPORT 4 LUB6 C-C C3.20 2
GBB-117-H020 PIPE SUPPORT 8 LUBS C-C C3.20 2
G88-118-HS11 PIPE SUPPORT 4 LUBS C-C C3.20 2
889-118-H017 PIPE SUPPORT 4 LUBB C-C C3.20 2
m -117-H018 PIPE SUPPORT 8 LUSB C-C C3.20 O
.a*;4 fh' g
page No.
2 TAKE S 01/20/87 LIERICK GEERATINB STATIIB8 UNIT 1 8 COMMON NUCLEAR CLASS 1, 2 4 3 INTEGRAL ATTADGENTS Selected for Enestnation - First Interval SYS NAME CLA06 CONp MWS COMP DESCI TYPE EXful CATO CATE ITEM 2
MD-117-H019 PIPE Bupp0RT 12 LUB5 -
C-C C3.20 2
' MD-117-Hef t PIPE Supp0RT 4 LUBE C-C C3.30 2
MD-117-Hett PIPE support 4 LUBE C-C C3. N 2
HOS-146-H010 P!PE Supp0RT 4 LUBE C-C C3.29 2
MBS-166-HOG 1 PIPE SUP90RT 8 Limb C-C C3.20 2
MHR-HXA-1-A E AT EXCH Supp0RT TOP NTS A C-C C3.10 2
IHt-HXA-2-3 E AT EXCH Supp0RT BOT NTS B C-C C3.10 se ESW 3
HBC-tel-Hele PIPE BUpp0RT to LUSS D-B D2. 29 3
HBC-981-H021 PIPE Supp0RT 8 LUSS D-3 D2. 29 l
3 MC-981-H991 PIPE Supp0RT ANCH SLEEV D-3 DE.29 i
3 HOC-083-HOSI PIPE Supp0RT 16 LUES D-B Dt.20 3
HSC-083-H012 PIPE Supp0RT PAD D-3 D2. 29 3
HBC-483-Het3 PIPE Supp0RT 8 LUG 6 D-B D2. 29 3
HBC-963-Mi PIPE Supp0RT 8 LUBE D-B DE. 20 3
MC-083-H901 Pipe supp0RT ANCH R.EEV D-B Bt.80 c.
s 3
MC-136-HB14 P!pE Supp0RT S Lim D-9 3R.80 3
leC-138-H901 PIPE Espp0RT ANCH EEEV D-3 M.80 3
HBC-130-H902 PIPE Supp0RT AND4 SL3V D-B Dt.te j
3 HBC-138-H983 PIDE Supp0RT ANCH PL D-B Ot.29 3
HBC-147-Het5 PIPE Supp0RT 8 LUBE D-B Dt.M i
3 MC-147-H901 PIPE E sp0RT f904 SLEEV D-B M. 89 l
3 leC-147-H982 PIDE rapport AICH EEEV D-B Bt.80 l
3 HBC-147-H993 PINE Supp0RT ANCH SLEEV D-B D8. 39 3
HOC-192-H901 PIPE SUPPORT ANCH EEEV D-B Dt.30 3
HSC-192-H982 P!PE Supp0RT ANCH EEEV D-B D2. 29 l
3 HBC-192-R303 FIPE SUPPORT ANCH EEEV D-B D2. 29 3
HOC-192-H984 PIDE Supp0RT ANCH EEEV D-B Dt.89 3
leC-194-H901 PIPE Rapp0RT NCH EEEV l>-9 St.m 3
HSC-194-H982 FIDE Supp0RT ANCH SLEEV D-B Dt.30 3
HSC-194-H993 PIPE Supp0RT fuCH EEEV D-B Dt. 39 3
HOC-194-H994 FIDE Supp0RT fDCH EEEV D-B D2.80 3
MC-194-H905 PIPE Supp0RT ANCH EEEV D-B Dt.20 3
HSC-194-H906 PIPE Supp0RT ANCH EEEV D-3 D2. 39 3
HBC-234-H991 DIPE support f3Of SLEEV D-3 08.30 3
leC-247-MBBS PIDE Ripp0RT 4 LUES D-9 St.40 3
HOC-247-H901 P!pt RApp0RT fuCH EEEV D-9 St.89 3
HBC-292-H901 PIPE RAPPORT f804 EEV D-B E8. 30 3
>SC-292-H982 FIDE Elpp0RT fuCH REV D-9 St.80 3
Dec-292-H993 Fist RJpp0RT fuCH RRV D-3 M. 30 3
Dec-292-H994 PIPE support fuCH SLEEV D-B D8. 30
- FPCC 3
leC-101-H006 PIPE Supp0RT 4 LUBS D-C D3.28 3
HBC-101-H014 PIPE Supp0RT 8 LUBE D-C D3. 30 3
HCC-104-HOtt PIPE Supp0RT 4 LUBE D-C D3.40 0
+-+--e---r
[V
'y Pete No.
3 TAGLE 5 01/20/87 LIERICK GEERATINB STATION LMIT 1 8 COMMON P4JCLEAR CLASS 1, 2 8 3 INTESRAL ATTADGENTS Selected for Examination - First Interval SYS NAME CLASS COMP HANS COMP DESC1 TYPE EXAfd.CATO CATS ITEN 3
HCC-104-H003 P!PE SUPPORT 8 LUB6 D-C D3.30 3
HCC-104-H006 PIPE SUPPORT 4 Lues D-C D3.40 3
HCC-104-H018 PIPE SUP90RT 8 LUBS D-C D3.28 3
HCC-104-H025 PIPE SUPPORT 8 LUB8 D-C D3. N 3
HCC-104-H901 PIPE SUPPORT ANCH PLATE D-C D3. 29 3
HCC-104-H982 PIPE Supp0RT ANCH PLATE D-C D3. 29 3
HCC-196-H001 PIPE Supp0RT 4 LUBS D-C D3.29 3
HCC-196-H001 PIPE SUPPORT 4 LUGS D-C D3.20 e.
GBC-101-H002 PIPE SUPPORT 4 LUBS D-A,B DI.2.40 3
GSC-101-H003 PIPE SUPPORT 4 LUBS D-A,8 DI,2.40 3
GBC-101-H029 PIPE SUPPORT 4 LUBB D-A, 3 Dl,2.44 3
GBC-101-H030 PIPE SUPPORT 4 LUBE D-A,B Dt 2.40 3
GBC-101-H033 PIPE SUPPORT 4 LUGS D-A,8 Dl,2.40 3
GBC-101-He34 PIPE SUPPORT 4 LUBS D-A,3 D1,2.40 3
GBC-101-H037 PIPE SUPPORT 4 LUBS D-A,3 Di,2.40
(
3 seC-101-Heae PIPE SUPPORT 4 LUBE D44,3 D1,2. 40 3
8BC-101-HIT 9 PIPE SUPPORT BLEEVE D-A,3 D1,2. 40 3
GBC-101-H200 PIPE SUPPORT SLEEVE D-A,3 01,2.40 3
68C-116-H901 PIPE SUPPORT ANCHOR D-A,3 DI 2.28 3
80C-l!6-H985 PIPE SUPP0nf ANCHOR D-A,3 DA,2.20 3
88C-il6-H998 PIPE SUPPORT ANDWR D-A B DI,2.20 3
GOC-Il6-H910 PIPE SUPPORT AMCHOR D-A,3 Dl. 2. 20
.R 3
GBC-192-H004 PIPE SUPPORT 8 LUGS D-A,3 Dl. 2. 20 3
GBC-193-H003 PIPE SUPPORT 12 LUGS D-A,B Dl.2.29 3
G8C-193-H004 PIPE SUPPORT 4 LUBS D-A,8 D1,2.20
- RHRSM j
3 HBC-091-H077 PIPE SUPPORT LUBS D-A,8 D1,2.20 3
H9C-091-H195 PIPE SUpp0RT 8 LUBS D-A.B Dt.2.30 3
HBC-091-HI32 PIPE Supp0RT 8 LUSS D-A,3 DI,2.29 3
HBC-091-H170 PIPE SUPPORT 3 LUB6 D-4, B D t,2. 20 l
3 HBC-091-H174 PIPE SUPPORT SLEEVE D-A,3 D1,2.30 l
3 HBC-091-H991 PIPE SUPPORT ARCH PLATE D-A,3 DI,2.29 t
3 WC-192-H901 PIPE Supp0RT ANCH M.EEV D-A,3 Dl,2.29 3
HBC-200-H004 PIPE SUPPORT 16 LUBS D-A,3 D1,2.30 3
WC-202-HOB 3 PIPE SUPPORT 12 LUBB D-A,B DI 2.29 3
HBC-507-H169 PIPE Supp0RT 2 LUBS D-A,3 Dt 2.80 3
WC-507-H901 PIPE SUPPORT AfCH SLEEV D-A,3 D1,2.29 3
WC-500-H901 PIPE SUPPORT AMCH SLEEV D-A, 3 D1,2. 20 3
WC-537-H901 PIPE SUPPORT AND4 R.EEV D-A, 3 Dl. 2. 29 O
.h j
P:ge No, 1
TABLE 6 01/20/87 LIMERICK GENERATING STATI(M LBIIT 14 CopMM NUCLEAR CLASS 1, 2 4 3 COMPONENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM
DCA-320-H001 M
F-A,B,C F8. SS 1
DCA-320-H002 M
F-A,B,C Ft. 80 1
DCA-320-H003 M
F-A,B,C Ft. SG 1
DCA-320-H004 V
F-A,B,C FO. 00 1
DLA-111-H001 V
F-A,B,C FO. 00 1
DLA-111-H003 M
F-A,B,C FO. 00 1
DLA-111-H004 M
F-A,B,C FO. 00 1
DLA-111-H005 M
F-A,B,C F0. 00 1
DLA-111-X-16A A
F-A,B,C FO. 00
DLA-196-H002 M
F-A,B,C FS. Se i
1 DLA-196-H003 M
F-A,B,C FO. 00 1
DLA-196-H004 V
F-A,B,C F0. 00 1
DLA-196-X-98 A
F-A,B,C Ft. 80 1
DLA-198-H001 V
F-A,B,C F0.~00 ~
1 DLA-198-H002 V
F-A,B,C F0.00 1
DLA-198-He'33 V
F-A,B,C F0. 00 1
DLA-198-H004 V
F-A,B,C Ft. OS 1
DLA-198-H005 V
F-A,B,C FS. 90 1
DLA-198-H006 V
F-A,B,C F0. 00 1
DLA-198-H007 V
F-A,B,C Ft. SS 1
DLA-198-H008 V
F-A,B,C F8. 90 1
DLA-198-H009 M
F-A,B C Ft. OS 1
DLA-198-H010 M
F-A,B,C F0. 00 1
DL A-198-H011 M
F-A,B,C FS. 80 1
DLA-198-H012 M
F-A,B,C FO. 90 1
DLA-198-H013 M
F-A,B,C Ft. 00 1
DLA-198-H014 M
F-A,B,C F0.00 1
DLA-198-H015 M
F-A,B,C F0.00 1
DLA-198-H016 M
F-A,B,C FO.Se 1
DLA-198-H017 M
F-A,B,C FS. et i
1 DLA-198-H018 M
F-A,B,C FO. 00 1
DLA-198-H019 M
F-A,B,C F0. 00 1
DLA-198-H020 M
F-A,B,C F0. 00 1
DLA-198-H021 M
F-A,B,C F0. 00 1
DLA-198-H022 M
F-A,B,C FO. 80 1
DLA-198-H023 M
F-A,B,C Fe. 80 1
DLA-198-H024 M
F-A,B,C F8. 90 1
DLA-198-h025 M
F-A,B,C F8. 00 1
DLA-198-H026 M
F-A,B,C Ft. Se l
1 DLA-198-H027 M
F-A,B,C F8. Se
- HPCI 1
DBA-196-H001 V
F-A,B,C F8.00 1
DBA-196-H002 V
F-A,B,C F0. 06
P:ge No.,
2 TAOLE 6 01/20/87 LIMERICK GENERATING STATION 1MIT 1 4 COMMON NUCLEAR CLASS 1, 2 4 3 COMPOENT BUPPORTS J
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HSR TYPE CATG CODE CATG ITEM 1
DBA-196-H003 M
F-A,B,C Ft. OS 1
DBA-196-H004 M
F-A,B,C F0. 00 1
DBA-196-H005 M
F-A,B,C Fe. OS 1
DBA-196-H006 M
F-A,B,C FS. OS 1
DBA-196-H007 M
F-A,B,C F0. 00 1
DBA-196-H008 M
F-A,B,C F0. 00 1
DBA-196-H009 M
F-A,B,C FO. 00 1
DBA-106-H010 M
F-A,B,C F0. 00 1
DBA-106-H012 M
F-A,B,C FO. 90 1
DBA-196-H013 M
F-A,B,C FO. 00 1
DBA-106-H014 M
F-A,B,C FS. SS 1
DBA-196-H015 V
F-A,B,C FS. 90 1
DBA-196-X-11 A
F-A,B,C Ft. Se
APE-1MS-H018 M
F-A,B,C FO. 80 1
APE-1MS-H019 M
~~F-A,B,C ~ ~F0.~00
~
1 APE-1MS-H020 M
F-A,B,C Ft. OS 1
APE-1MS-H021 M
F-A,B,C FS. OS 1
APE-1MS-H022 M
F-A,B,C FS. SG 1
APE-1MS-H023 M
F-A,B,C FO. OS 1
APE-1MS-H024 M
F-A,B,C FO. OS 1
APE-1MS-H025 M
F-A,B,C FO. 80 1
APE-1MS-H026 M
F-A,B,C FO. 90 1
APE-1MS-HHC1 V
F-A,B,C FS. 80 1
APE-1MS-leiC2 V
F-A, B, C Ft. OS 1
APE-1MS-HHC3 V
F-A,B,C FS. SG 1
APE-1MS-X7C A
F-A,B,C FS. 80 1
STG-1MS-H027 R
F-A,B,C Ft.Se
- RCIC 1
DBA-197-H002 V
F-A,B,C F0. 00 1
DBA-197-H003 V
F-A,B,C F0. 00 1
DBA-197-H005 V
F-A,B,C F0. 00 1
DBA-197-H006 M
F-A,B,C F0. 00 1
DBA-197-H007 M
F-A,B,C FO. 80 1
DBA-197-H000 M
F-A,B,C FO. 00 1
DBA-197-H009 M
F-A,B,C Ft. 80 1
DBA-197-H010 M
F-A,B,C F0. 00 1
DBA-107-H011 M
F-A,B,C FS. 00 1
DBA-197-H012 M
F-A,B,C F0. 00 1
DBA-107-H013 M
F-A,B,C F0. 00 1
DBA-197-HJ14 M
DBA-107-H015 M
F-A,B,C F0. 00 1
DBA-197-H016 M
F-A,B,C Fe. 80 1
DBA-107-H017 M
F-A,B,C FO. 80 1
DBA-197-H018 M
F-A,B,C F0. 00
- Q.
i
P:ge No.
3 TABLE 6 01/20/87 LIMERICK GENERATING STATION LedIT 1 & COPSION
""'"a" a" ' ' ' ' ' ' "'""'
'"a'""'"
Cj' Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 1
DBA-197-H019 M
F-A,B,C F0.00 1
DBA-197-H020 R
F-A,B,C FO 00 1
DBA-197-H022 M
F-A,B,C Ft. SS 1
DBA-197-H023 M
F-A,B,C FO. 00 1
DBA-197-H024 R
F-A,B,C F0. 00 1
DBA-197-H025 R
F-A,B,C FO. 00 1
DBA-107-H027 V
F-A,B,C FO. 80 1
DBA-197-X-10 A
DCA-193-H003 V
F-A,B,C FO. OS 1
DCA-193-H005 V
F-A,B,C FO. 00 1
DCA-193-H009 M
F-A,B,C FS. 80 1
DCA-193-H010 M
DCA-193-H011 M
F-A,B,C FO. 90 1
DCA-193-H012 R
F-A,B,C Ft.Se
~~~
1 DCA-193-H013-M
~F-A,B,C Ft.~00 ~ ~ ~'-~ -
1 DCA-193-H014 M
F-A,B,C F0. 00 1
DCA-193-H015 M
F-A,B,C F0. 00 1
DCA-193-H016 M
F-A,B,C F0.00 0
1 DCA-193-H017 V
F-A,B,C F0. 00 1
DCA-193-H020 M
F-A,B,C Ft. 80 1
DCA-193-H023 V
F-A,B,C F0. 00 1
DCA-193-H024 M
F-A,B,C FO. 00 1
DCA-103-H025 R
F-A,B,C FO. 80 1
DCA-193-H026 M
F-A,B,C Ft. OS 1
DCA-193-H027 R
F-A,B,C FO. 80 1
DCA-193-H028 R
F-A,B,C FO. 80 1
DCA-104-H007 Y
F-A,B,C F0. 00 1
DCA-104-H008 V
F-A,B,C F0. 00 1
DCA-104-H009 V
F-A,B,C FO. 80 1
DCA-104-H010 V
F-A,B,C Ft. 80 1
DCA-104-H011 V
F-A,B,C FO. OS 1
DCA-104-H012 V
F-A,B,C Ft. OS 1
DCA-104-H023 M
F-A,B,C Ft. 80 1
DCA-104-H024 M
F-A,B,C F0. 00 1
DCA-104-H825 M
F-A,B,C FO. 00 1
DCA-104-H026 M
F-A, B, C FO. 80 1
DCA-104-H027 M
F-A,B,C FO. Se I
1 DCA-104-H028 M
F-A,B,C Fe. SG 1
DCA-104-H029 M
F-A,B,C FO. Se 1
DCA-104-H030 M
F-A,B,C Fe. 80 1
DCA-104-H031 M
F-A,B,C FS. 00 l
1 DCA-104-H032 M
F-A,B,C FO. 00 1
DCA-104-X-13A A
F-A,B,C FO. 00 1
DCA-195-H001 V
F-A,B,C F0. 00 r
1 DCA-105-H002 V
F-A,B,C FO. 80 a
1 l
l
P:Ge No.
4 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 COMMON NUCLEAR CLASS 1, 2 8 3 COMPONENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 1
DCA-195-H003 V
F-A,B,C FS. SS 1
DCA-195-H004 V
F-A,B,C Ft. OS 1
DCA-195-H005 M
F-A,B,C FS. 80 1
DCA-195-H006 M
F-A,B,C FO.00 1
DCA-195-H007 M
F-A,B,C FO. 00 1
DCA-195-H008 M
F-A,B,C Ft. OS 1
DCA-105-H009 M
F-A,B,C FS.40 1
DCA-195-H010 M
F-A,B,C FO. 90 1
DCA-105-H011 M
F-A,B,C FO. OS 1
DCA-105-H012 M
F-A,B,C F0. 00 1
DCA-105-H013 M
F-A,B,C FO. 80 1
DCA-195-H014 M
F-A,B,C FO. 80 1
DCA-105-H015 M
F-A,B,C FS. 80 1
DCA-195-H016 M
F-A,B,C Fe. OS 1
DCA-105-H017 M
F-A,B,C FO. OS 1
DCA-195-X-12 A
F-A,B,C FO. OS
~
1 DCA-318-H002~
M F-A,B,C~
-- Ft. Se 1
DCA-318-H006 V
F-A,B,C FS. 90 1
DLA-112-H005 V
F-A,B,C FS. OS 1
DLA-112-H013 R
F-A,B,C FS. 00 t
1 DLA-112-H016 M
F-A,B,C Ft. SG 1
DLA-112-H017 M
F-A,B,C F0. 00 1
DLA-112-H020 M
F-A,B,C FO. 80 1
DLA-112-X-45A A
F-A,B,C F0. 00
- RR l
1 SP-DCA-185-E1H01 V
F-A,B,C Fe. 80 1
F-A, B, C-FO.SG 1
F-A,B,C Fe. 30 1
F-A,B,C FO. OS 1
F-A,B,C FO. OS 1
F-A,B,C F0.00 1
F-A,B,C FS. 80 1
F-A,B,C FS. SS 1
F-A,B,C Ft. 80 1
VRR-1RD-H011 M
F-A,B,C F0. 00 1
VRR-!RD-Hele M
F-A, B, C Ft. 80 1
VRR-1RD-H013 M
F-A,B,C FO. 00 1
VRR-1RD-H014 M
F-A,D,C FO. 80 1
VRR-1RD-H015 M
F-A,B,C FO. 90 1
VRR-1RD-H016 M
F-A,B,C FO. 00 1
VRR-1RD-H017 M
F-A,B,C Ft. SS 1
VRR-1RD-H018 M
F-A,B,C F0. 90 1
VRR-1RD-H019 M
F-A,B,C FO. 00 1
VRR-1RD-H020 M
F-A,B,C FO. 80 1
VRR-1RD-HHB2 V
F-A,B,C FO. 00 1
VRR-1RD-HHB3 V
F-A,B,C FO. Se O
P:ge No.
5 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 14 C0peION q
NUCLEAR CLASS 1, 2 4 3 COMPONENT SUPPORTS V
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 1
VRR-1RD-HHB4 V
F-A,B,C Ft. OS 1
VRR-1RM-H005 M
VRR-1RM-H006 M
F-A,B,C FO. OS 1
VRR-1RM-H008 M
F-A,B,C F0. 80 1
VRR-1RP-H004 M
F-A,B,C FO. 80 1
VRR-1RP-H005 M
F-A,B,C F0. 00 1
VRR-1RP-H006 M
F-A,B,C FS. WO 1
VRR-1RS-H006 M
F-A,B,C F0. 00 1
VRR-1RS-H007 M
F-A,B,C FO. 90 1
VRR-1RS-H008 M
F-A,B,C F0. 00 1
VRR-1RS-H009 M
F-A,B,C FO. 00 1
VRR-1RS-Hele M
F-A,B,C FO. 00 1
VRR-1RS-HHP 1 V
F-A,B,C FO. 90 1
VRR-1RS-HHB5 V
F-A,B,C F0. 00 1
VRR-1RS-HHB6 V
F-A,B,C FO. 80 1
VRR-1RS-HHB7 V
F-A,B,C F0. 00 1
VRR-1RS-PBRB ~
~
A F-A,B,C FS. W
'~
ee RWCU 1
DBA-112-H001 M
F-A,B,C FS. SG O
1 DBA-112-H002 V
F-A,B,C F0. 00 1
DBA-112-H003 M
F-A,B,C Ft. 80 1
DBA-112-H004 M
F-A,B,C FO. 00 1
DBA-112-H005 R
F-A,B,C FO. 80 1
DBA-112-H006 R
F-A,B,C FO. 80 1
DBA-112-H007 R
F-A,B,C Ft. 30 1
DBA-112-H008 R
F-A,B,C F0. 00 1
DBA-112-H009 R
F-A,B,C FS. 80 1
DBA-112-H010 R
F-A,B,C FO.00 1
DBA-112-H011 R
F-A,B,C FS. 80 1
DBA-112-H012 R
DBA-112-H013 R
F-A,B,C Ft. 80 1
DBA-112-H014 R
F-A,B,C FO. 80 1
DBA-112-H015 R
F-A,B,C FS. OS 1
DBA-112-H016 R
F-A,B,C F0. 00 1
DBA-112-H817 R
F-A,B,C F0. 00 1
DBA-112-X-44 A
F-A,B,C FO. 00 1
DCA-101-H003 V
F-A,B,C Ft. 80 1
DCA-101-H004 V
F-A,B,C FO. 00 1
DCA-101-H005 V
F-A,B,C FO. 80 1
DCA-101-H006 R
DCA-101-H007 R
F-A,B,C FS. 80 1
DCA-101-H008 M
F-A,B,C FO. 00 1
DCA-101-H009 M
F-A,B,C FO. 80 1
DCA-101-H010 M
F-A,B,C F0. 00 1
DCA-101-H011 M
F-A,B,C FO. Se 1
DCA-101-H012 M
F-A,B,C FO. 00 4
=_
P:ge No.
6 TABLE 6 01/20/87 LIMERICK GEERATING STATION LMIT 1 & C0F004 O
NUCLEAR CLASS 1, 2 4 3 COMP 0 PENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 1
DCA-101-H013 M
F-A,B,C F0. 00 1
DCA-101-H014 M
F-A, B, C FO.00 1
DCA-101-H015 M
F-A,B,C FO. 00 1
DCA-101-H016 M
F-A,3,C FO. 00 1
DCA-101-H017 M
F-A,B,C FO. OS 1
DCA-101-H018 M
F-A,B,C FO. 90 1
DCA-101-H044 V
F-A,B,C FO. 80 1
DCA-101-H045 M
F-A,B,C FO. 80 1
DCA-101-H046 M
F-A,B,C FO. 00 1
DCA-101-H047 M
F-A,B,C F0. 00 1
DCA-101-H048 M
F-A,B,C FO. OS 1
DCA-101-H049 M
DCA-101-H050 M
F-A,B,C F0. 00 1
DCA-101-H051 M
F-A,B,C FO. 00 1
DCA-101-H052 M
F-A,B,C FO. 80 1
DCA-101-H053 V
F-A,B,C FO. Se
~
1 DCA-101-H054- -
M~~' ~ F-A,B,C-~~~FO M
-~
1 DCA-101-H055 M
F-A,B,C Fe.80 1
DCA-181-H056 M
F-A,B,C Fe. 80 1
DCA-101-H057 M
F-A,B,C FO. 90 0
2 oca->ai-a sa a
r-a a c 1
DCA-101-H059 M
F-A,B,C FO. 00 1
DCA-101-H060 M
F-A,B,C F0. 00 1
DCA-101-H061 V
F-A,B,C FO. 90 1
DCA-101-H062 M
F-A,B,C F0. 00 1
DCA-101-H063 M
F-A,B,C FS. 00 1
DCA-101-H064 M
F-A,B,C FO. 80 1
DCA-101-H065 M
F-A,B,C FO. Se 1
DCA-101-H066 V
F-A,B,C Ft. OS 1
DCA-101-H067 V
F-A,B,C FO. 80 1
DCA-101-H068 M
F-A,B,C FS. 80 1
DCA-101-H069 M
F-A,B,C FO. OS 1
DCA-101-H070 M
F-A,B,C FO. 80 1
DCA-101-H071 M
F-A,B,C F0. 00 1
DCA-101-H072 M
F-A,B,C Fe. OS 1
DCA-101-X-14 A
F-A,B,C FO. 80 1
DCA-113-H001 R
F-A,B,C F0. 00 1
DCA-113-H003 V
F-A,B,C FO. 80 1
DCA-113-H004 M
F-A,B,C FO. 80 1
DCA-113-H005 R
F-A,B,C FO. Se 1
DCA-113-H006 R
F-A,B,C FO. OS 1
DCA-113-H007 M
F-A,B,C FS. 90 1
DCA-113-H008 M
F-A,B,C FO. 80 1
DCA-113-H009 R
F-A,B,C FO. 00 1
F-A,B,C FO. 90 1
F-A,B,C FO. OS 1
F-A,B,C FO. 80
+
s
P ge No.
7 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON p) '
NUCLEAR CLASS 1, 2 & 3 COMP 0 PENT SUPPORTS 4
s.
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 1
SP-DCA-113-E1H82 x,y M
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00
- SLC 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C FO. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A, B, C
~Ft.OS~~
1 SP-DCA-192-E2H11 R
F-A,B,C F0. 00 l
1 SP-DCA-182-E2H12 R
F-A,B,C F0. 00 l
1 SP-DCA-182-E2H13 R
F-A, B, C F0. 00
()
1 SP-DCA-182-E2H16 R
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C FO. 00 1
SP-DCA-192-E2X116 A
F-A,B,C FO. 00 1
F-A,B,C FO. 00 1
F-A, B, C FS. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00 1
F-A,B,C FS. 80 1
F-A,B C F0. 00 l
1 SP-DCA-112-E2H11 R
F-A,B,C F0. 00 1
F-A,B.C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C F0. 00 1
F-A,B,C FO. 00 1
F-A,B,C FO. 00 1
F-A,B,C FO.00 1
F-A,B,C FO. 00
?
e
P ge No.
8 TABLE 6 91/20/87 LIMERICK GENERATING STATION UNIT 1 4 COMON C)
NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMEER HGR TYPE CATG CODE CATG ITEM 1
F-A,B,C FO. 80 1
F-A,B,C FO. 80 1
F-A,B,C FO. 80 1
F-A,B,C FO. Se i
1 SP-DCA-112-E3H13 R
F-A,B,C F0. 00 1
F-A,B,C F0. 80 1
F-A,B,C FO. 90 1
F-A,B,C FO. 00
CSB-P-Al F-A,B,C FO. 00 2
CSD-P-A1 F-A,B,C FO. 00 2
EBB-131-H002 V
F-A,B,C FO. OS 2
EBB-131-H003 M
F-A,B,C F0. 00 2
EBB-131-H004 M
F-A,B,C FO. 80 2
EBB-131-H005 V
F-A,B,C Fe. SS
-~
~ 2 EBB-131-H006 ~
~
M~~
F-A, B, C -
F0. 00 ---"
2 EBB-131-H007 V
F-A,B,C Ft. 30 2
EBB-131-H008 R
F-A,B,C FS. SO 2
EBB-131-H009 R
F-A,B,C Ft. 80 O
2 EBB-131-H010 M
F-A,B,C FS. 80 2
GBB-112-H001 R
F-A,B,C F0. 00 2
GBB-112-H002 R
F-A,B,C FO. 00 2
GBB-112-H003 V
F-A,B,C FO. 00 2
GBB-112-H004 R
F-A,B,C FO. 80 2
GBB-112-H005 M
F-A, B, C FO. 80 2
GBB-112-H006 R
F-A,B,C F0. 00 2
GBB-112-H007 R
F-A,B,C FS. SS 2
GBB-112-H008 R
F-A,B,C FO. 80 2
GBB-112-H003 R
F-A,B,C FS. SS 2
GBB-112-H010 R
F-A,B,C F0. 00 2
GBB-112-H011 V
F-A,B,C F0.00 2
GBB-112-H012 R
F-A,B,C Ft. OS 2
GBB-112-H013 V
F-A,B,C FS. SS 2
GBB-112-H026 R
F-A,B,C FO. 80 2
GBB-112-He30 R
F-A,B,C FO. OS 2
GBB-112-He31 M
F-A,B,C FS. OS 2
GBB-112-H033
.R F-A,B,C Fe. 80 2
GBB-112-H034 R
F-A,B,C FO. 80 l
2 GBB-112-H036 R
F-A,B,C FO. 90 2
GBB-112-H037 V
F-A,B,C FS. 80 2
GBB-112-He38 R
F-A,B,C FO. 80 2
GBB-112-H039 V
F-A,B,C FO. 80 2
GBB-112-H040 R
F-A,B,C FO. OS 2
GBB-112-H041 M
F-A,B,C F0. 00 2
GBB-112-H043 R
F-A,B,C F0. 00 2
GBB-112-H049 V
F-A,B,C FO. Se 0
i
Page No.
9 TABLE 6 01/20/87 LIMERICK GENERATING STATION LMIT 14 Copem
)
NUCLEAR Ct. ASS 1, 2 & 3 COMP (NENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
GBB-112-H050 M
F-A,B,C FS.00 2
GBB-112-H051 R
F-A,B,C FO. 00 2
GBB-112-H052 R
F-A,B,C FS. 00 2
GBB-112-H053 R
F-A,B,C F0. 00 2
GBB-112-H981 A
F-A,B,C FS. 80 2
GBB-114-H001 V
F-A, P. C FS. 80 2
GBB-114-H003 V
F-A,B,C FS. 00 2
GBB-114-H004 R
F-A,B,C Fe. 90 2
GBB-114-H005 M
F-A,B,C F8. 00 2
GBB-114-H006 R
F-A,B,C FS. 80 2
HBB-120-H008 R
F-A,B,C Fe. 80 2
HBB-120-H009 R
F-A,B,C F0. 00 2
HBB-120-H010 M
F-A,B,C FS.00 2
HBB-120-H011 R
F-A,B,C F8. 00 2
HBB-120-H012 R
F-A,B,C FS. 80 2
HBB-120-H013 V
F-A,B,C FS. 00
~
~2 HBB-120-HS14
~
~ V F-A,9,C - FS.00 ~ ~ ~ ~ - -
2 HBB-120-H015 M
F-A,B,C FS. OS 2
HBB-120-H016 R
F-A,B,C FS. OS 2
HBB-120-H017 R
F-A,B,C Ft. 80 2
HBS-120-H023 M
F-A,B,C FO. 80 2
HBB-120-H027 M
F-A,B,C FS.OS 2
HBB-120-H028 M
F-A,B,C FO. 80 2
HBB-120-H029 R
F-A,B,C Fe. 80 2
HBB-120-He32 V
F-A,B,C F0. 00 2
HBB-120-He33 M
F-A,B,C FS.80 2
HBB-134-H001 R
F-A,B,C FS. 00 2
HBB-134-H002 M
F-A,B,C FO. 00
- CRD HYD 2
EBB-142-SH-E01 R
F-A,B,C Ft. OS 2
EBB-142-SH-E02 R
F-A,B,C F0. 00 2
EBB-142-SH-E03 R
F-A, B, C FO. OS 2
EBB-142-SH-E04 R
F-A,B,C Ft. 80 2
EBB-142-SH-E85 R
F-A,B,C FS. 30 2
EBB-142-SH-E86 R
F-A,B,C F0. 00 i
2 EBB-142-SH-E07 R
F-A,B,C F0. 00 2
EBB-142-SH-E09 R
F-A,B,C F0.00 2
EBB-142-SH-E18 R
F-A,B,C F0. 00 2
EBB-142-SH-E11 R
F-A,B,C F0. 00 2
EBB-142-SH-E12 R
F-A,B,C F0. 00 2
EBB-142-SH-E13 R
F-A,B,C Ft. OS 2
EBB-142-SH-E14 R
F-A,B,C F0. 00 l
2 EBB-142-SH-E15 R
F-A,B,C F0. 00 1
2 EBB-142-SH-E16 R
F-A,B,C FO. 00 2
EBB-142-SH-E17 R
EBB-142-SH-E18 R
F-A,B,C Fe. 80
P ge No.
le TAGLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 8 CCB006 A
NUCLEAR CLASS 1, 2 & 3 COMP 0 PENT SUPPORTS U.
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
EBB-142-SH-E19 R
F-A,B,C Ft. OS
DBB-183-H004 R
F-A,B,C FO. 80 2
DBB-193-H005 R
F-A,B,C FO. 90
- HPCI 2
EBB-108-H002 M
F-A,B,C FO. OS 2
EBB-198-H004 M
F-A,B,C F0.00 2
EBB-108-H005 R
F-A,B,C FO. 90 2
EBB-198-H007 R
F-A,B,C FO.00 2
EBB-198-H008 R
F-A,B,C FO. 90 2
EBB-198-H009 R
F-A,B,C FO. 90 2
EBB-108-H016 M
F-A,B,C FO. 90 2
EBB-108-H019 M
F-A,B,C FO. 00 2
EBB-198-H020 V
F-A,B,C FO. 80 2
EBB-198-H022 V
F-A,B,C F0.~ 00 ' ~~ ~ -
2 EBB-198-H023 M
F-A,B,C F8. SS 2
EBB-198-H024 R
F-A,B,C FO. 90 2
EBB-188-H025 R
F-A,B,C FO. 80 2
EBB-198-H026 M
F-A,B,C FS. OS 2
EBB-198-H027 R
F-A,B,C FO. Se 2
EBB-198-H028 R
F-A,B,C FO. 80 2
EBB-108-H029 R
F-A,B,C FO. 90 2
EBB-198-H030 R
F-A,B,C FO. 90 2
EBB-198-He32 M
F-A,B,C Fe. 80 2
EBB-198-H033 V
F-A,B,C FS. 80 2
EBB-198-He34 M
F-A,B,C FO. OS 2
EBB-198-H035 M
F-A,B,C FO. 80 2
EBB-198-He36 V
F-A,B,C FO. OS 2
EBB-198-H037 M
F-A,B,C FS. OS 2
EBB-198-He38 M
F-A,B,C FS. 80 2
EBB-198-He39 M
F-A,B,C FS. OS 2
EBB-198-H981 A
F-A,B,C FO. 80 2
EBB-129-H001 R
F-A,B,C FS. OS 2
EBB-129-H001A R
F-A,B,C F0. 00 2
EBB-129-H002 R
F-A,B,C FO. 80 l
2 EBB-129-H004 R
F-A,B,C FO. 80 2
EBB-129-H005 M
F-A,B,C FO. Se 2
EBB-129-H006 V
F-A,B,C FO. 90 2
EBB-129-H007 V
F-A,B,C FO. OS 2
EBB-129-H008 R
F-A,B,C FO. 80 2
EBB-129-H008A M
F-A,B,C Fe. 80 2
EBB-129-H009 R
F-A,B,C FO. 80 2
EBB-129-H010 R
F-A,B,C FO. 00 2
EBB-129-H010A M
F-A,B,C FO. 90 2
EBB-129-H011 V
F-A,B,C FO. 90
P;te No.
11 TABLE 6 01/20/87 LIMERICK GEERATING STATION i
UNIT 1 8 C0p010N NLELEAR CLASS 1, 2 & 3 COMPOENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM
_ _.. - - = - -
2 EBB-129-H011A M
F-A,B,C FO. 80 2
EBB-129-H012 V
F-A,B,C Fe. 80 2
EBB-129-H013 V
F-A,B,C FO. 90 2
EBB-129-H015 R
F-A,B,C FS. 90 2
EBB-129-H016 R
F-A,B,C Fe. 80 2
EBB-129-H017 R
F-A,B,C FO. 80 2
EBB-129-H018 M
F-A,B,C FS. 80 2
EBB-129-H027 R
F-A,B,C FO. OS 2
EBB-129-H030 R
F-A,B,C FO. 00 2
EBB-129-He33 R
F-A,B,C FO. 00 2
EBB-129-H036 M
F-A,B,C F0. 00 2
EBB-129-H041 R
F-A,B,C F0. 00 2
EBB-129-H043 R
F-A,B,C FO. 00 2
EBB-129-H044 R
F-A,B,C FO. 90 2
EBB-129-H045 V
F-A,B,C FO. 00 2
EBB-129-H046 R
F-A,B,C FS. SG
~
~~
2 EBB-129-H047 M-F-A,B,~C ~ FO.Se
~~
2 EBB-129-H048 V
F-A,B,C F0.00 2
EBB-129-H049 M
F-A,B,C F0. 00 2
EBB-129-H050 R
F-A,B,C FS. 80 0
2 EBB-129-H051 M
F-A,B,C FO. 80 2
EBB-129-H052 R
F-A,5,C F0. 00 2
EBB-129-H054 V
F-G,B,C FO. 80 2
EBB-129-H055 R
F-A,B,C FO. 00 2
EBB-129-H056 R
F-A,B,C FO. OS 2
EBB-129-H058 M
F-A,B,C Ft. OS 2
EBB-129-H059 R
F-A,B,C F0.00 2
EBB-129-H060 R
F-A,B,C FO. 80 2
EBB-129-H061 R
F-A,B,C F0. 00 2
EBB-129-H981 A
F-A,B,C FO. OS 2
EBB-129-H982 A
F-A,B,C FS. 80 2
EBB-129-H993 A
F-A,B,C Ft. 90 2
EBB-134-H004 R
F-A,B,C FO. OS 2
EBB-134-H991 A
F-A,B,C FS. 80 2
HBB-198-H003 V
F-A,B,C FO.80 2
HBB-198-H003A R
F-A,B,C FO. 80 2
HBB-198-H004 M
F-A,B,C Fe. OS 2
HBB-198-H005 R
F-A,B,C FO. 80 2
HBB-198-H006 R
F-A,B,C FO. 80 2
HBB-198-H007 R
F-A,B,C FO. 00 2
HBB-108-H009 M
F-A,B,C Fe. Se 2
HBB-198-H011 M
F-A,B,C FO. Se l
2 HBB-198-H012 R
F-A,B,C FO. Se l
2 HBB-198-H013 R
F-A,B,C FO. 00 2
HBB-108-X-210 A
F-A,B,C FO. Se l
2 HP-P-A R
F-A,B,C F0. 00 l
O
P:g] No.
12 TABLE 6 01/20/87 LIMERICM GENERATING STATION 1
UNIT 1 & COMMON
)
O NUCLEAR CLASS 1, 2 4 3 COMPONENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM
= - - _
EBB-101-H001 V
F-A,B,C Fe. 80 2
EBB-101-H002 R
F-A,B,C F0. 00 2
EBB-101-H003 R
F-A,B,C FO. 80 2
EBB-101-H004 R
EBB-101-H005 R
F-A,B,C FO. 00 2
EBB-101-H006 M
F-A,B,C FO. Se 2
EBB-101-H007 R
F-A,B,C FO. OS 2
EBB-101-H008 R
F-A,B,C FO. 00 2
EBB-101-H009 R
F-A,B,C FO. 00 2
EBB-101-H010 M
F-A,B,C FO. 80 2
EBB-101-H011 R
F-A,B,C FO. 80 2
EBB-101-H012 M
F-A,B,C FO. 00 2
EBB-101-H013 R
F-A,B,C FO. 00 2
EBB-101-H014 M
F-A,B,C FO. 90 2
EBB-101-H015 R
F-A,B,C FO. OS
~
~
2 EBB-101-H016 R--~
F-A,B,C F0.~ 00 -
~
2 EBB-101-H017 R
F-A,B,C FO. 80 2
EBB-101-H025 R
F-A,B,C F8. 00 2
EBB-101-H026 R
F-A,B,C FO. 80 2
EBB-101-H027 R
F-A,B,C FS.00 2
EBB-101-H028 R
F-A,B,C F0. 00 2
EBB-101-H031 R
F-A,B,C F0. 00 2
EBB-106-H001 V
F-A,B,C FS. 80 2
EBB-196-H002 R
F-A,B,C FO. 80 2
EBB-196-H003 R
F-A, B, C FO. OS 2
EBB-196-H004 R
F-A,B,C FO. 00 F-A B,C FS. OS 2
EBB-196-H005 M
i 2
EBB-196-H006 M
F-A,B,C FO. 80 2
EBB-196-H010 M
F-A,B,C F0. 00 i
2 EBB-197-H001 R
F-A,B,C FO. 80 2
EBB-197-H002 R
F-A,B,C FS. OS 2
EBB-197-H003 R
F-9,B,C FO. 80 2
EBB-197-H004 M
F-A,B,C FS. OS 2
EBB-197-H005 M
F-A,B,C Ft. 80 2
EBB-197-H006 M
F-A,B,C FS.Se
- MSIVLC 2
HBB-154-H001 R
F-A,B,C FO. OS 2
HBB-154-H002 R
F0. 00 F0. 00 2
HBB-154-H003 R
F-A,B,C FO. OS 2
HBB-154-H004 R
F-A,B,C F0. 00 2
HBB-154-H005 R
F-A,B,C FO. 90 2
HBB-154-H006 R
F-A,B,C FO.96
- RCIC.
2 10P-203A A
F-A,B,C FO. Se l
l
PZee No.
13 TABLE 6 01/20/87 LIMERICK GENERATING STATION l
UNIT 1 & Co m 0N p3 NUCLEAR CLASS 1, 2 4 3 COMPOPENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
DBB-101-H002 M
F-A,B,C FS. 00 2
EBB-199-H001 V
F-A,B,C F0. 00 2
EBB-199-H002 M
F-A,B,C Fe. 80 2
EBB-199-H004 V
F-A,B,C Fe. OS 2
EBB-199-H005 R
F-A,B,C FO. 90 2
EBB-199-H006 V
F-A,B,C FO. 00 2
EBB-199-H007 R
F-A,B,C FO. 80 2
EBB-199-H008 R
F-A,B,C FO. 00 2
EBB-199-H009 R
F-A,B,C FO. 90 2
EBB-199-H010 R
F-A,B,C F8. OC 2
EBB-199-H011 R
F-A,B,C Fe. 90 2
EBB-199-H012 M
F-A,B,C FO. 90 2
EBB-199-H013 R
F-A,B,C Fe. Se 2
EBB-199-H014 R
F-A,B,C FO. 00 2
EBB-199-H016 M
F-A,B,C FO. 80 2
EBB-199-H018 R
F-A,B,C F0. 00 2
EBB-199-H019 R
F-A,B,C F0. OS
~
2 EBB-199-H021 R
F-A,B,C Ft.OS-2 EBB-199-H022 R
F-A,B,C F0. 00 2
EBB-199-H02J M
F-A,B,C Ft.00 0~
2 EBB-199-H024 R
F-A,B,C FO. Se 2
EBB-199-H032 R
F-A,B,C Fe. Se 2
EBB-199-He33 R
F-A,B,C F0. 00 2
EBB-199-H635 M
F-A,B,C FO. 90 2
EBB-199-H036 M
F-A,B,C Fe. 80 2
EBB-199-He37 M
F-A,B,C FO. 90 2
EBB-199-He38 M
F-A,B,C FS. 90 2
EBB-199-He39 M
F-A,B,C F0. 00 2
EBB-199-H040 M
F-A,B,C FO. OS 2
EBB-199-H041 M
F-A,B,C FS. SS 2
EBB-199-H045 R
F-A,B,C FO. 90 2
EBB-199-H046 M
F-A,B,C F0.00 2
EBB-199-H047 R
F-A,B,C F0. 00 2
EBB-199-H048 R
F-A,B,C F0. 00 2
EBB-199-H055 R
F-A, B, C Ft. 90 2
EBB-126-H001 R
F-A,B,C FO. OS 2
EBB-126-H002 R
F-A,B,C Ft. OS 2
EBB-126-H003 R
F-A,B,C FS. 80 2
EBB-126-H004 R
F-A,B,C FS. 00 2
EBB-126-H005 R
F-A,B,C F0. 00 2
EBB-135-H002 V
F-A,B,C FO. 80 2
EBB-135-H003 R
F-A,B,C FO. 80 2
EBB-135-H004 R
F-A,B,C FS. 80 2
EBB-135-H005 R
F-A,B,C Fe. 80 2
EBB-135-H006 R
F-A,B,C FO. S8 2
EBB-135-H007 R
F-A,B,C F8. 00 2
EBB-135-H008 V
F-A,B,C FO. Se O
O
---e
---.,n.-
+,,.-_.nn,
-..-.y
P:g] No.
14 TABLE 6 01/20/87 LIMERICK GENERATING STATION
}
LMIT 1 & COMMON
/]-
NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS k-Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
EBB-135-H009 V
F-A,B C FO. 80 2
EBB-135-H81e R
F-A,B,C F8. 80 2
EBB-135-H010A R
F-A,B,C F0. 00 2
EBB-135-H011 R
F-A,B,C FO. Se 2
EBB-135-H015 R
F-A,B,C FO. 00 2
EBB-135-H016 R
F-A,B,C FO. 00 2
EBB-135-H017 R
F-A,B,C F8. 90 2
EBB-135-H018 R
F-A,B,C F0. 00 2
EBB-135-H019 Fi F-A,B,C FO. 00 2
EB3-135-H020 M
F-A,B,C FO. OS 2
EBB-135-H021 R
F-A,B,C F0. 00 2
EBB-135-H022 R
F-A,B,C FO. 90 2
EBB-135-H023 R
F-A,B,C FO. 90 2
EBB-135-H024 R
F-A,B,C FO. 90 2
EBB-135-H025 R
F-A,B,C FO. 80 2
EBB-135-H027 R
F-A,B,C FS. Se i
2 EBB-135-H028 V ~
~F-A,B,C FS. OS -
2 EBB-135-H029 R
F-A,B,C FO. 90 2
EBB-135-He30 M
F-A,B,C FO. Se 2
EBB-135-He31 R
F-A,B,C F0. 00 O
2 EBB-135-H991 A
F-A,B,C F0. 00 2
EBB-135-H982 A
F-A,B,C FO. Se 2
HBB-101-H001 V
F-A,B,C FO. 99 l
2 HBB-101-H002 R
F-A,B,C FO. 80 2
HBB-101-H003 R
F-A,B,C FO. 80 2
HBB-101-H004 R
F-A,B,C Fe. SS 2
HBB-101-H005 R
F-A,B,C FO. 80 2
HBB-101-H006 V
F-A,B,C F8. 00 2
HBB-101-H007 R
F-A,B,C FO. 80 2
HBB-101-H008 R
F-A,B,C FO. 80 2
HBB-101-H009 M
F-A,B,C Ft. 80 2
HBB-181-H018 R
F-A,B,C FO. 00 l
2 HBB-101-H011 R
F-A,B,C FS. 90 2
HBB-101-H012 M
HBB-101-H013 M
F-A,B,C Ft. 30 2
HBB-101-H014 M
F-A, B, C F0. 00 l
2 HBB-101-H015 R
F-A,B,C FO. 90 2
HBB-101-H016 M
F-A,B,C FO. 80 2
HBB-101-X-215 A
EBB-198-H040 M
F-A,B,C FS. 80 2
EBB-121-H001 R
F-A,B,C FO 90 2
EBB-121-H002 R
F-A,B,C FO. 80 2
EBB-121-H003 R
F-A,B,C FO. 90 2
EBB-121-H007 R
F-A,B,C FO. 90 2
EBB-121-H008 R
F-A,B,C FO. 90
P:ge No.
15 TABLE 6 01/20/87 LIMERICK GENERATING STATION 1
UNIT 1 & COMMON NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS 07, Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
EBB-121-H009 V
F-A,B,C Ft. 80 2
EBB-121-H010 R
F-A,B,C Ft. 80 2
EBB--121-H011 R
F-A,B,C FS. SS 2
EBB-121-H012 V
F-A,B,C F8. OS 2
EBB-121-H013 R
F-A,B,C FS. 80 2
EBB-121-H014 R
F-A,B,C FO. 00 2
EBB-121-H015 R
F-A,B,C FO. OS 2
EBB-121-H016 R
F-A,B,C FO. 90 2
EBB-121-H018 V
F-A,B,C FO. 80 2
EBB-121-H019 R
F-A,B,C FS. 90 2
EBB-121-H022 R
F-A,B,C FO. 80 2
EBB-121-H024 R
F-A,B,C FO. 90 2
EBB-121-H027 M
F-A,B,C FO. OS 2
EBB-121-H028 V
F-A,B,C F0. 00 2
EBB-121-H029 M
F-A,B,C FO. OS 2
EBB-121-He30 R
F-A,B,C Ft. SS 2
EBB-121-H032
~R'
~ ~ F-A,B,C~ ~ FS!88 - ~--'
2 EBB-121-He33 R
F-A,B,C FS. OS 2
EBB-121-H035 M
F-A,B,C F0. 00 2
EBB-121-H036 M
F-A,B,C Fe. 80 0
2 EBB-121-He38 M
F-A,B,C FS. 80 2
EBB-121-He39 M
F-A,B,C F0.00 2
EBB-121-H040 M
F-A,B,C FO. OS 2
EBB-121-H041 M
F-A,B,C FO. 00 2
EBB-121-H043 M
F-A,B,C FO. 90 2
EBB-121-H991 A
F-A,B,C Ft. OS 2
EB3-121-H982 A
F-A,B,C FO. 80 2
ECB-111-H001 V
F-A,B,C FO. OS 2
ECB-111-H002 V
F-A,B,C Ft. 80 2
ECB-111-H003 V
F-A,B,C Ft. SS 2
ECB-111-H004 V
F-A,B,C FS. OS 2
ECB-111-H005 V
F-A,B,C Ft. OS 2
ECB-111-H006 V
F-A,B,C Ft. 80 2
ECB-111-H008 M
F-A,B,C Ft. 90 2
ECB-111-H009 M
F-A,B,C FO. 80 2
ECB-111-H010 M
F-A,B,C FO. 80 2
ECB-111-H011 M
F-A,B,C F8. OS 2
ECB-111-H012 M
ECB-111-H013 M
F-A,B,C Ft. 80 2
ECB-111-H014 M
F-A,B,C FO. 90 2
ECB-111-H015 M
F-A,B,C FO. 80 2
ECB-111-H016 M
F-A,B,C FO. 80 2
ECB-111-H018 M
F-A,B,C FO. 80 2
ECB-111-H019 M
F-A,B,C FO. OS 2
ECB-111-H320 M
F-A,B,C FO. 00 2
ECB-111-H021 M
F-A,B,C FO. 00 2
ECB-111-H022 M
mm
P:ge No.
16 TABLE 6 01/20/87 LIMERICK GENERATING STATION l
LMIT 1 & CDPMON (3
NUCLEAR CLASS 1, 2 & 3 CONDONENT SUPPORTS U
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM l
2 ECB-111-H023 M
ECB-111-H024 M
F-A,B,C FO. 90 2
ECB-111-H025 M
F-A,B,C FO. 60 l
2 ECB-111-H026 M
F-A,B,C FO. OS 2
ECB-111-H027 M
F-A,B,C FO. OS 2
ECB-111-H028 M
F-A,B,C F0. 00 2
ECB-111-H029 V
F-A,B,C FO. OS 2
ECB-111-H030 M
F-A,B,C FO. 90 2
ECB-111-H031 M
F-A,B,C FO. 00 2
ECB-111-H032 R
F-A,B,C FO. 90
(
2 ECB-111-H033 R
F-A,B,C FO. 80 l
2 ECB-111-He34 M
F-A,B,C FO. 00 l
2 ECB-111-H035 V
F-A,B,C FO. 80 2
ECB-111-H036 M
F-A,B,C FO. 90 2
ECB-111-H037 R
F-A B,C FO. OS 2
ECB-111-H038 M
F-A,B,C FO. 80 2
ECB-111-H991 A
F-A,8 C ~~ ~ FO. 80 l
2 ECB-111-X-17 A
F-A,B,C FO. 80 i
2 GBB-101-W11 R
F-A,B,C F0. 00 2
GBB-101-H013 M
F-A,B,C Ft. 80 2
GBB-101-H014' R
GBB-101-H015 V
F-A,B,C F0. 00 2
GBB-101-H016 R
F-A,B,C FO. Se l
2 GBB-101-H018 V
F-A,B,C FO. 90 l
2 GBB-181-H019 R
F-A,B,C FO. 90 2
GBB-101-H020 M
F-A,B,C FS. 90 l
2 GBB-101-H022 R
F-A,B,C FO. 80 2
GBB-101-H027 V
F-A,B,C FO. 80 2
GBB-101-He33 M
F-A,B,C FO. Se 2
GBB-182-H008 M
F-A,B,C FO. 80 l
2 GBB-192-H009 V
F-A,B,C FO. 80 2
GBB-192-H010 M
F-A,B,C FO. Se 2
GBB-192-H811 R
F-A,B,C FO. 80 i
2 GBE-102-H012 M
F-A,B,C Ft. 30 2
GBB-192-H013 V
F-A,B,C FO. 30 2
GBD-192-H014 M
F-A,B,C FO. 80 2
GBB-192-H015 V
F-A,B,C Ft. 80 2
GB3-182-H019 M
F-A,B,C Fe. 80 2
GBB-192-H020 M
GBB-192-H027 M
F-A,B,C FO. 80 2
GBB-102-H028 M
F-A,B,C FO. 90 2
GEB-192-H029 V
F-A,B,C FO. 80 2
GEB-102-H030 M
F-A,B,C FO. 90 2
GEB-192-H034 M
F-A,B,C FO. 00 2
GEB-103-H001 M
F-A,B,C FO. 90 2
GEB-103-H002 M
F-A,B,C FO. 00 2
GEB-103-H003 M
F-A,B,C FO. 00 1
P:g] No.
17 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS
/
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
GBB-103-H004 V
F-A,B,C FO. OS 2
GBB-103-H005 M
F-A,B,C FO. OS 2
GDD-103-H006 R
F-A,B,C FO. 90 2
GBB "I.3-H007 M
F-A,B,C FO. OS 2
GBB-103-H008 R
F-A,B,C FS. SS 2
GBB-103-H009 M
F-A,B,C F0. 00 2
GBB-103-H010 V
F-A,B,C FO. OS 2
GBB-103-H011 R
F-A,B,C FO. 00 2
GBB-103-H012 R
F-A,B,C FO. 90 2
GBB-103-H013 M
F-A,B,C FO. 00 2
GBB-103-H014 R
F-A,B,C FO. 80 2
GBB-103-H016 V
F-A,B,C FO. 00 2
GBB-103-H017 R
F-A,B,C FO. 00 2
GBB-105-H001 V
F-A,B,C FO. 00 2
GBB-105-H008 V
F-A,B,C FO. 00 2
GBB-195-H009 M
F-A,B,C F0. 00 2
GBB-195-H010 M-~~
F-A,B,C FO. 00
- -~~
2 GBB-195-H011 R
F-A,B,C F0. 00 2
GBB-195-H012 M
F-A, B, C FO. 00 2
GBB-195-H013 M
F-A,B,C FO. 00 2
GBB-195-H014 R
F-A,B,C FO. 80 2
GBB-195-H015 R
F-A,B,C FO. 00 2
GBB-105-H016 R
F-A,B,C FS. OS 2
GBB-105-H017 R
F-A,B,C FO. 00 2
GBD-105-He29 M
F-A,D,C FO. OS 2
GBB-195-He30 R
F-A,B,C FS. 80 2
GEB-105-X-39A A
F-A,B,C FO. OS 2
GBB-196-H001 V
F-A,B,C FO. 80 2
GBB-196-H002 R
F-A,B,C F0. 00 2
GBB-196-H003 R
F-A,B,C FO. 90 2
GBB-196-H007 M
F-A,B,C FO. OS 2
GBB-196-H008 M
F-A,B,C FO. 80 2
GBB-106-H009 M
F-A,B,C FO. OS 2
GBB-197-H001 V
F-A,B,C FO. OS 2
GBB-197-H002 R
F-A,B,C FO. OS l
2 GBB-197-H003 R
F-A,B,C FS. 00 2
GBB-197-H004 R
F-A,B,C FO. Se 2
GBB-197-H007 M
F-A,B,C FO. OS 2
GBB-197-H008 M
F-A,B,C Fe. 80 2
GBB-107-H009 V
F-A,B,C FO. 90 2
GBB-107-H010 M
F-A,B,C FO. 80 2
GBB-197-H011 M
F-A,B,C FO. 90 2
GBB-107-H012 M
F-A,B,C FO. OS 2
GBB-107-H013 R
F-A,B,C FO. 00 2
GBB-107-H014 V
F-A,B,C FO. 00 2
GBB-107-H026 (x,y)
M F-A,B,C FO. 90 2
GBB-107-H027 M
F-A,B,C FO. 80 0
r--
P ge No.
18 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & C0 pet 0N NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS O'
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
GBB-197-H028 M
F-A,B,C Ft. OS 2
GBB-197-X-205A A
F-A,B,C FO. 00 2
GBB-198-H001 V
F-A,B,C FO. 80 2
GBB-198-H007 R
GBB-198-H009 M
F-A,B,C F0. 00 2
GBB-198-H011 R
F-A,B,C Ft. 90 2
GBB-198-H012 R
F-A,B,C Ft. OS 2
GBB-198-H013 R
F-A,B,C F0. 00 2
GBB-108-H014 M
F-A,B,C FO. 80 2
GBB-198-X-204A A
F-A,B,C FO. OS 2
GBB-111-H001 V
F-A,B,C F0. 00 2
GBB-111-H002 R
F-A,B,C FO. 80 2
GBB-111-H003 R
F-A,B,C F8. 80 2
GBB-111-H004 R
F-A,B,C F0. 00 2
GBB-111-H005 R
F-A,B,C FS. OS 2
GBB-111-H006 M
F-A,B,C FO. OS 2
BBB-111-H007 R
F-A,B,C' F t.' 0 0 ~~ ~ ~ '
2 GBB-111-H008 R
F-A,B,C F0.00 2
GBB-117-H005 V
F-A,B,C FO. OS l
2 GBB-117-H006 R
F-A,B,C Ft.Se l
2 GBB-117-H008 R
F-A,B,C Ft. SS 2
GBB-117-H009 V
F-A,B,C FO. 80 2
GBB-117-H010 M
F-A,B,C F0. 00 2
GBB-117-H015 R
F-A,B,C FO. 00 2
GBB-117-H016 V
F-A,B,C FO. 80 2
GBB-117-H018 R
F-A,B,C F0. 00 2
GBB-117-H019 M
F-A,B,C Ft. 90 2
GBB-117-H020 R
F-A,B,C FO. 00 2
GBB-118-H001 R
F-A,B,C F0.00 2
GBB-118-H002 R
F-A,B,C F0. 00 2
GBB-118-H004 R
F-A,B,C Ft. 90 2
GBB-118-H005 V
F-A,B,C Ft.00 2
GBB-118-H008 V
F-A,B,C Ft. 90 2
GBB-118-H017 V
F-A,B,C F0. 00 2
GBB-118-H018 R
F-A,B,C F0. 00 2
GBB-118-H019 V
F-A,B,C FO. 00 2
GBB-118-H020 R
F-A,B,C Ft. 80 2
GBB-118-H021 R
F-A,B,C FO. 00 2
GBB-118-H022 R
F-A,B,C Ft. 90 2
GBB-118-H024 R
F-A,B,C FO. 00 2
GBB-118-H025 h
F-A,B,C Ft. OS 2
GBB-118-H026 R
F-A,B,C F0. 00 2
GBB-118-H028 M
F-A,B,C F0. 00 2
GBB-118-H029 M
F-A,B,C FO. 00 2
GBB-118-H033 M
F-A,B,C FO. Se 2
GBB-118-H034 M
F-A,B,C F0. 00 2
GBB-118-He35 M
F-A,B,C Ft. 80 0
c
..-n-_...
P ge No.
19 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 8 COMMON
-* g NUCLEAR CLASl31, 2 & 3 COMPOPENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
GBB-118-H836 R
F-A,B,C FS. 00 2
GBB-118-H037 M
F-A,B,C FS. 80 2
GBB-118-H055 V
F-A,B,C FS. 80 2
GBB-118-H056 M
F-A,B,C FO. 00 2
GBB-118-H057 V
F-A,B,C FS. 80 2
GBB-118-H059 M
F-A,B,C F0. 00 2
GBB-118-H860 M
F-A,B,C FO. OS 2
GBB-118-H067 M
F-A,B,C F0.00 2
GBB-118-H068 M
F-A,B,C F0. 00 2
GBB-118-H069 R
F-A,B,C FO. 80 2
GBB-118-H072 M
F-A,B,C FO. 80 2
GBB-118-H073 R
F-A,B,C FO. 90 2
GBB-118-H076 R
F-A,B,C FS. 80 2
GBB-118-H080 R
F-A,B,C F0. 00 2
GBB-118-H081 M
F-A,B,C FS. 80 2
GBB-118-H082 R
F-A,B,C FO. Se 2
GBB-110-H981 A
- F-A,B,C
~ Ft. OS -
2 GBB-118-H982 A
F-A,B,C FO. OS 2
GBB-119-H016 V
F-A,B,C F0. 00 2
GBB-119-H016A R
F-A,B,C F0. 00 i
2 GBB-119-H817 M
F-A,B,C FO. 00 2
GBB-119-H017A R
F-A,B,C F8. OS 2
GBB-119-H018 V
F-A,B,C FS. 00 2
GBB-119-H019 R
F-A,B,C FO.00 2
GBB-119-H019A R
F-A,B,C F8. 00 2
GBB-119-H020 R
F-A,B,C FS. OS 2
GBB-119-H827 Y
F-A,B,C FO. OS 2
GBB-119-H028 R
F-A,B,C F0. 00 2
GBB-119-H029 R
F-A,B,C FO. OS 2
GBB-119-He30 R
F-A,B,C FS. 80 2
GBB-119-He31 R
F-A,B,C F0. 00 2
GB8-119-He32 V
F-A,B,C FS.00 2
GBB-119-H058 R
F-A,B,C F8. 00 2
GBB-119-H059 R
F-A,B,C FS. 80 2
GBB-119-H066 M
F-A,B,C FS.SS 2
GBB-119-H061 R
F-A,B,C FO. 80 2
GBB-119-H062 R
F-A,B,C FS. OS 2
GBB-119-H063 M
F-A,B,C F0. 00 2
GBB-119-H064 R
F-A,B,C F8. 00 2
GBB-119-H065 R
F-A,B,C FS. 80 2
GBB-119-H066 R
F-A,B,C F8. 80 2
GBB-119-H067 R
F-A,B,C FS. OS 2
GBB-119-H068 R
F-A,B,C FO. 80 2
GBB-119-H069 R
F-A,B,C FO. OS 2
GBB-119-H070 M
F-A,B,C FS. 80 2
GBB-119-H071 R
F-A,B,C F0. 00 2
GBB-119-H072 R
F-A,B,C F8. 80 p.-
-.my%,,-ww-,--.--v,v-ow--,
w
+-w e-nw--c.-w-.----,-w-y,.m-m, w-----
w- - -
P:ge No.
20 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COPMON
/
NUCLEAR CLASS 1, 2 & 3 COMPOPENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
GBB-119-H073 R
F-A,B,C FO. 80 2
GBB-119-H074 R
F-A,B,C FO. 80 2
GBB-119-H075 M
F-A,B,C FO. 80 2
GBB-119-H076 V
F-A,B,C FO. 90 2
GBB-119-H097 M
F-A,B,C F0. 00 2
GBB-119-H100 M
F-A,B,C FS. OS 2
GBB-119-H191 M
F-A,B,C FO. 80 2
GBB-119-H194 M
F-A,B,C FO. 90 2
GBB-119-H105 R
F-A,B,C FO. 00 2
GBB-119-H106 M
F-A,B,C FO.00 2
GBB-119-H107 R
F-A,B,C FO. 80 2
GBB-119-H198 M
F-A,B,C FO. 90 2
GBB-119-H109 V
F-A,B,C FO. 90 2
GBB-119-H903 A
F-A,B,C FO. 00 2
GBB-119-H904 A
F-A,B,C FO. 00 2
GBB-120 H002 R
F-A,B,C FO. 80 2
GBB-120-H001 V
F-A,B,C FO. Se ~ ~~
2 GBB-120-H004 M
F-A,B,C FO.00 l
2 GBB-120-H008 M
F-A,B,C FO. 80 2
GBB-120-H009 M
F-A,B,C FO. 90 0
2 HBB-117-H001 V
F-A,B,C FS. 80 2
HBB-117-H002 R
F-A,B,C FS. 90 2
HBB-117-H004 V
F-A,B,C F0.00 2
HBB-117-H011 M
F-A,B,C Fe. OS 2
HBB-117-H018 R
F-A,B,C FO. 00 2
HBB-117-H021 R
2 HBB-117-H023 M
F-A,B,C FO. Se i
2 HBB-117-H025 M
F-A,B,C FS. 00 2
HBB-118-H001 V
F-A,B,C FO. Se l
2 HBB-118-H003 R
F-A,B,C F0. 00 2
HBB-118-H005 V
F-A,B,C FS. 80 2
HBB-118-H006 R
F-A,B,C FO.80 2
HBB-118-H008 R
F-A,B,C FO. 80 2
HBB-118-H009 V
F-A,B,C FO. 80 2
HBB-118-H010 V
F-A, D, C FS. Se 2
HBB-118-H011 V
F-A,B,C F0. 00 2
HBB-118-H012 R
F-A,B,C FO. OS 2
HBB-118-H013 R
F-A,B,C FS. 80 2
HBB-118-H014 R
F-A,B,C FO. 80 2
HBB-118-H015 V
F-A,B,C FO. 90 2
HBB-118-H016 V
F-A,B,C FO. 80 2
HBB-118-H020 V
F-A,B,C FS. SS 2
HBB-118-H026 R
F-A,B,C FO. 90 2
HBB-118-H030 M
F-A,B,C FO. 90 2
HBB-118-He31 M
F-A,B,C FO. 80 2
HBB-118-H032 R
F-A,B,C FO.00 2
HBB-118-H034 M
F-A,B,C FO. Se 0
i
P ge No.
21 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 COMMON
((
NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS Ast Selected for Examination - First Interval m
SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 2
HBB-118-H035 R
F-A,B,C FS. 00 2
HBB-118-H036 M
F-A,B,C FS. 00 2
HBB-118-H037 M
F-A,B,C FO. 00 2
HBB-118-He38 M
F-A,B,C FO. 00 2
HBB-118-H040 M
F-A,B,C FO. 00 2
HBB-118-H041 M
F-A,B,C FO. 00 2
HBB-118-H042 R
F-A,B,C FO. 00 2
HBB-118-H044 M
F-A,B,C FO. 00 2
HBB-118-H045 R
F-A,B,C FO. 00 2
HBB-118-H047 M
F-A,B,C FO. 00 2
HBB-118-H048 M
F-A,B,C FO. 00 2
HBB-118-H049 V
F-A,B,C FO. 00 2
HBB-118-H355 M
F-A,B,C F0. 00 2
HBB-118-HB56 M
F-A,B,C FO. 00 2
HBB-118-H057 R
F-A,B,C F0. 00 2
HBB-118-H05S M
F-A,B,C FO. 00 2
HBB-118-H059 M
F-A,B,C FO. 00
~~~
2 HBB-118-H060 R
F-A,B,C FO. 00 2
HBB-118-H061 M
F-A,B,C FO. 00 2
HBB-118-H062 R
F-A,B,C FO. 00 0
2 HBB-118-H069 R
F-A,B,C F0. 00 2
HBB-118-H070 M
F-A,B,C F0. 00 2
HBB-118-H072 M
F-A,B,C FO. 80 2
HBB-118-H073 M
F-A,B,C FO. 00 l
2 HBB-118-H074 M
F-A,B,C FO. 00 2
HBB-118-H075 M
F-A,B,C FS. 00 2
HBB-118-H076 M
F-A,B,C F0. 00 2
HBB-118-H077 M
F-A,B,C FO. 00 2
HBB-118-H078 M
F-A,B,C FO. 00 2
HBB-118-H079 M
F-A,B,C FO. 00 2
HBB-118-H082 M
F-A,B,C FO. 00 2
HBB-118-H083 M
F-A,B,C FO. 00 2
HBB-118-H084 V
F-A,B,C FO. 00 2
HBB-118-H085 M
F-A,B,C FS. 00 2
HBB-118-H086 M
F-A,B,C F0. 00 1
2 HBB-118-H088 R
F-A,B,C F0. 00 2
HBB-119-H001 M
F-A,B,C F0. 00 2
HBB-119-H002 M
F-A,B,C FS. 00 2
HBB-119-H003 V
F-A,B,C Fe. 80 2
HBB-119-H004 M
F-A,B,C F0. 00 2
HBB-119-H005 V
F-A,B,C FO. 00 2
HBB-119-H006 M
F-A,B,C FO. 00 2
HBB-119-H007 R
F-A,B,C FO. 00 2
HBB-119-H008 M
F-A,B,C FO. 00 2
HBB-119-H009 R
F-A,B,C FO. 00 2
HBB-119-H010 R
F-A,B,C FO. 00 2
HBB-119-H011 V
F-A,B,C FO. 00
P ge No.
22 TAOLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON NUCLEAR CLASS 1, 2 & 3 COMP 0ENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM
=
2 HBB-119-H012 R
F-A,B,C F0. 00 2
HBB-119-H013 M
F-A,B,C F0. 00 2
HBB-119-H014 R
F-A,B,C FO. 00 2
HBB-119-H015 M
F-A,B,C F0. 98 2
HBB-119-H016 V
F-A,B,C F0. 00 2
HBB-119-H017 M
F-A,B,C FO. 00 2
HBB-119-H018 M
F-A,B,C F0. 00 2
HBB-119-H019 R
F-A,B,C FO. 00 2
HBB-119-H901 A
F-A,B,C FO. 90 2
HBB-119-H902 A
F-A,B,C F0. 00 2
HBB-140-H010 V
F-A,B,C F0. 00 2
HBB-140-H011 V
F-A,B,C FO. 00 2
HBB-140-H012 M
F-A,B,C FO. 00 2
HBB-140-H013 M
F-A,B,C FO. 00 2
HBB-140-H015 M
F-A,B,C F0. 00 2
HBB-140-H016 M
F-A,B,C F0. 00 2
HBB-140-H017 R
F-A,B C F0. 00 2
HBB-143-H019 R
F-A,B,C F0. 00 2
HBB-140-X-239 A
F-A,B,C F0. 00 2
HBB-160-H001 R
F-A,B,C FO. 00 2
HBB-160-H002 R
F-A,B,C F0. 00 O'
2 HBB-160-H003 R
F-A,B,C FO. 00 2
HBB-160-H904 R
F-A,B,C F0. 00 2
HBB-160-H005 R
F-A,B,C FO. 00 2
HBB-160-H006 M
F-A,B,C FO. 00 2
HBB-160-H007 M
F-A,B,C F0. 00 2
HBB-160-H008 V
F-A,B C F0. 00 2
NBB-160-H010 R
F-A,B,C FO. 00 2
HBB-160-H011 R
F-A,B,C F0. 00 2
HBB-160-H012 V
F-A,B,C F0. 00 2
HBB-160-H014 M
F-A,B,C FS. 00 2
HBB-160-H015 M
F-A,B C F0. 00 2
HBB-160-H016 M
F-A,B,C F0. 00 2
HBB-160-H017 M
F-A,B,C F0. 00 2
RHA-P-Al F-A,B,C F0. 00 2
RHR-HXA-1-A V
F-A,B C F0. 00 2
RHR-HXA-1-B V
F-A,B,C FS. 00 l
2 RHR-HXA-1-C V
F-A,B,C F0. 00 2
RHR-HXA-1-D V
F-A,B,C FO. 80 2
RHR-HXA-2-A V
F-A,B,C FO. 00 2
RHR-HXA-2-B V
F-A,B,C F0. 00 2
RHR-HXA-2-C V
F-A,B,C FO. 00 2
RHR-HXA-2-D V
F-A,B,C F0. 00
- + ESW 3
HBC-081-H002 R
F-A,B,C FO. 00 3
HBC-081-H003 R
F-A,B,C FO. 00 0
,-w m
P:g3 No.
23 7ABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 Cope m NUCLEAR CLASS 1, 2 4 3 COMPONENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATS ITEM 3
HBC-081-H004 R
F-A,B,C FO. 80 3
HBC-081-H005 R
F-A,B,C Fe. Se 3
HBC-081-H006 R
F-A,B,C FO. OS 3
HBC-081-H007 R
F-A,B,C FO. OS 3
HBC-081-H008 R
F-A,B,C FO. 80 3
HBC-081-H009 R
F-A,B,C FO. 80 3
HBC-081-H010 R
F-A,B,C FS. 80 3
HBC-081-H011 R
F-A,B,C Fe. 80 3
HBC-081-H012 R
F-A,B,C FO. 80 3
HBC-081-H013 R
F-A,B,C FO. 00 3
HBC-081-H014 R
F-A,B,C FO. 80 3
HBC-081-H015 R
F-A,B,C FO. 90 3
HBC-081-H016 R
F-A,B,C FO. 80 3
HBC-081-H017 V
F-A,B,C FO. 00 3
HBC-081-H018 R
F-A,B,C FO. 90 3
HBC-081-H019 V
F-A,B,C FO. 80 3
HBC-081-H020 R
F-A,B,C FO. Se ~
3 HBC-081-H021 R
F-A,B,C F0. OS 3
HBC-081-H022 R
F-A,B,C FO. 80 3
HBC-081-H991 A
F-A,B,C FS. OS p
3 HBC-083-H001 R
F-A,B,C F0. 80 v
3 HBC-083-H002 R
F-A,B,C FO. 80 3
HBC-083-H003 R
F-A,B,C FS. OS 3
HBC-083-H004 M
F-A,B,C FO. Se 3
HBC-083-H005 R
F-A,B,C FO. 00 3
HBC-083-H006 R
F-A,B,C FS. 80 3
HBC-083-H007 R
HBC-083-H009 R
F-A,B,C F0. 90 3
HBC-083-H010 R
F-A,B,C FO. 80 3
HBC-083-H011 R
F-A,B,C FO. OS 3
HBC-083-H012 R
F-A,B,C FS. 80 3
HBC-083-H013 R
F-A,B,C FO. Se 3
HBC-083-H014 R
F-A,B,C FO. 80 3
HBC-083-H015 R
F-A,B,C FS. 80 3
HBC-083-H016 R
F-A,B,C FS. OS l
3 HBC-083-H017 R
F-A,B,C FO. OS 3
HBC-083-H019 R
F-A,B,C FO. OS 3
HBC-083-H020 R
F-A,B,C Ft.SG-l 3
HBC-083-H021 R
F-A,B,C FO. 80 3
HBC-083-H022 R
F-A,B,C FO. OS 3
HBC-083-H023 R
F-A,B,C FO. 80 3
HBC-083-H024 R
F-A,B,C FO. 80 3
HBC-083-H026 R
F-A,B,C FS. 80 3
HBC-083-H027 M
F-A,B,C FO. 80 3
HBC-083-H901 A
F-A,B,C FO. 90 3
HBC-138-H002 R
F-A,B,C FS. 90 3
HBC-138-H003 R
F-A,B,C FO. 90 O
J
P:ge No.
24 TARE 6 01/20/87 LIMERICK GENERATING STATION 1MIT 14 C0F001 m.
NUCLEAR CLASS 1, 2 & 3 C0pWOENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE C/4TG ITEM 3
HBC-138-H004 R
F-A,B,C F0. 00 3
HBC-138-H005 R
F-A,B,C FO. Se 3
HBC-138-H006 R
F-A,B,C FO. 80 3
HBC-138-H007 R
F-A,B,C FO. 80 3
HBC-138-H008 R
F-A,B,C FS. 96 3
HBC-138-H008A R
F-A,B,C FO. 00 3
HBC-138-H009 R
F-A,B,C FO. 80 3
HBC-138-H009A R
F-A,B,C FO. 80 3
HBC-138-H010 R
F-A,B,C FO. Se 3
HBC-138-H010A R
F-A,B,C FO. 00 3
HBC-138-H011 R
F-A,B,C FO. 00 3
HBC-138-H012 R
F-A,B,C FO. 80 3
HBC-138-H013 R
F-A,B,C FO. 80 3
HBC-138-H014 R
F-A,B,C FO. 00 3
HBC-138-H015 R
F-A,B,C FO. 90 3
HBC-138-H016 R
F-A,B C FS. Se 3
HBC-138-H018 R
F-A,B,'C -~ FS.Se
~
3 HBC-138-H019 R
F-A,B,C FO. 80 3
HBC-138-H020 R
F-A,B,C FS. 80 3
HBC-138-H021 R
F-A,B,C FS. OS 0
3 HBC-138-H022 R
F-A,B,C Ft. Se 3
HBC-138-H023 R
F-A,B,C Ft. 90 3
HBC-138-H024 R
F-A,B,C FO. 80 3
HBC-138-H025 R
'F-A,B,C FO. 80 3
HBC-138-H026 R
F-A,B,C FO. 80 3
HBC-138-H028 R
F-4,B,C FO. 80 3
HBC-138-H901 A
F-A,B,C FO. 90 3
HBC-138-H902 A
F-A,B,C FS. Se I
3 HBC-138-H983 A
F-A,B,C Ft. OS 3
HBC-147-H001 R
F-A, B, C FO. OS 3
HBC-147-H002 R
F-A,B,C FS. 80 3
HBC-147-H003 R
F-A,B,C FS. 80 3
HBC-147-H004 R
F-A,B,C F0. 00 3
HBC-147-H005 R
F-A,B,C Ft. 90 3
HBC-147-H006 R
F-A,B,C Ft. 80 3
HBC-147-H006A M
F-A,B,C F0. 00 3
HBC-147-H007 R
F-A,B,C FS. 80 3
HBC-147-H008 R
F-A,B,C FO. 80 3
HBC-147-H008A R
F-A,B,C FS. 80 3
HBC-147-H009 R
F-A,B,C F0. 00 3
HBC-147-H010 R
F-A,B,C FO. OS 3
HBC-147-H011 R
F-A,B,C F0. 00 3
HBC-147-H011A R
F-A,B,C Ft. OS 3
HBC-147-H012 R
F-A,B,C F0. 00 3
HBC-147-H013 R
F-A,B,C FO. 00 3
HBC-147-H014 R
F-A,B,C FO.00 3
HBC-147-H015 R
F-A,B,C FO. 90 I
,.___,__-__---y, y- _, _ __ -. _ - _ _ -
-r--
[
P ge No, 25 TABLE 6 01/20/87 LIMERICK GEERATING STATION UNIT 18 C0pecN NUCLEAR CLASS 1, 2 4 3 COMPONENT SUP90RTS Selected for Examination - First Interval 4
SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 3
HBC-147-H016 R
F-A,B,C Ft.80 3
HBC-147-H017 R
F-A,B,C Ft. 00 3
HBC-147-H019 R
F-A,B,C Ft. 80 3
HBC-147-H020 R
F-A,B,C F0. 00 3
HBC-147-H021 R
F-A,B,C FS. 80 3
HBC-147-H022 R
F-A,B,C FO. 80 3
HBC-147-H023 R
F-A,B,C FO. OS 3
HBC-147-H025 R
HBC-147-H027 R
F-A,B,C FO. 80 3
HBC-147-H030 R
F-A,B,C FO. 00 3
HBC-147-H031 R
F-A,B,C FO. 00 3
HBC-147-He33 R
F-A,B,C F0. 00 3
HBC-147-H034 R
F-A,B,C FO. 80 3
HBC-147-H901 A
F-A,B,C F0. 00 3
HBC-147-H902 A
F-A,B,C FO. 80 3
HBC-147-H993 A
F-A,B,C FS. 80 3
HBC-158-H001 R
F-A,B,C FO.OS ~
3 HBC-192-H005 R
F-A,B,C FO. 80 3
HBC-192-H006 R
F-A,B,C Ft. 80 3
HBC-192-H007 R
F-A,B,C FS. 80 3
HBC-192-H008 R
F-A,B,C FS. 80 3
HBC-192-H009 R
F-A,B,C F0.80 3
HBC-192-H010 R
F-A,B,C Ft. 80 3
HBC-192-H011 R
F-A,B,C FO. 80 3
HBC-192-H012 R
F-A,B,C F8. Se 3
HBC-192-H013 R
F-A,B,C FS. OS 3
HBC-192-H014 R
r-A,B,C FS. 80 3
HBC-192-H015 R
F-A,B,C FO. 90 3
HBC-192-H016 R
F-A, B, C FS. OS 3
HBC-192-H017 R
HBC-192-H018 R
F -A, B, C Ft. OS 3
HBC-192-H019 R
F-A,B,C Ft.90 3
HBC-192-H020 R
F-A,B,C Ft. 80 3
HBC-192-H901 A
F-A,B,C Ft. Se 3
HBC-192-H982 A
F-A,B,C FS.00 3
HBC-192-H983 A
F-A,B,C FO.00 3
HBC-192-H994 A
F-A, B, C FS.00 3
HBC-194-H005 R
F-A,B,C FO. 80 3
HBC-194-H006 R
F-A,B,C F0.00 3
HBC-194-H007 R
F-A,B,C F0.00 3
HBC-194-H008 R
F-A,B,C F0. 00 3
HBC-194-H010 R
F-A,B,C FO. OS 3
HBC-194-H011 R
F-A,B,C FS.00 3
HBC-194-H012 R
F-A,B,C FO. 00 3
HBC-194-H013 R
F-A,B,C FS. OS 3
HBC-194-H014 R
F-A,B,C FO. 00 3
HBC-194-H015 R
F-A,B,C FO. Se
P ge No.
26 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON CJ Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM
=
3 HBC-194-H016 R
F-A,B,C FS. 80 3
HBC-194-H017 R
F-A,B,C F0. 00 3
HBC-194-H018 R
F-A,B,C F0. 00 3
HBC-194-H019 R
F-A,B,C F8. 00 3
HBC-194-H020 M
F-A,B,C FO. OS 3
HBC-194-H021 R
F-A,B,C FO.00 3
HBC-194-H901 A
F-A,B,C F8. 00 3
HBC-194-H902 A
F-A,B,C F0. 00 3
HBC-194-H903 A
F-A,B,C FO. OS 3
HBC-194-H904 A
F-A,B,C FO. 00 3
HBC-194-H905 A
F-A,B,C FO. 80 3
HBC-194-H906 A
F-A,B,C FO. Se 3
HBC-238-H001 R
F-A,B,C FO.00 3
HBC-238-H002 R
F-A,B,C F0. 00 3
HBC-238-H003 R
F-A,B,C F0. 00 3
HBC-238-H012 R
F-A,B,C ~
FO.80 3
HBC-238-H901 A
F-A,B,C ~
F0.~ 00-~ --
3 HBC-247-H007 R
F-A,B,C F0. 00 3
HBC-247-H008 V
F-A,B,C FS. 80 3
HBC-247-H009 R
F-A,B,C Ft. SS
(]
3 HBC-247-H010 R
F-A,B,C Ft. OS U
3 HBC-247-H901 A
F-A,B,C F0. 00 3
HBC-270-H002 R
F-A,B,C Ft. OS 3
HBC-270-H003 R
F-A,B,C FO.00 3
HBC-270-H004 R
F-A,B,C F0. 00 3
HBC-292-H001 R
F-A,B,C FS. 80 3
HBC-292-H002 R
F-A,B,C FO. OS 3
HBC-292-H003 R
F-A,B,C Ft. Se 3
HBC-292-H005 R
F-A,B,C FO. OS 3
HBC-292-H006 R
F-A,B,C Ft. 80 3
HBC-292-H021 R
F-A,B,C FO. 80 3
HBC-292-H991 A
F-A, B, C Ft. 80 3
HBC-292-H982 A
F-A,B,C FS. 80 3
HBC-292-H993 A
F-A, B, C FS. OS 3
HBC-292-H994 A
F-A,B,C Ft. OS
- FPCC 3
HBC-101-H008 R
F-A,B,C Fe. 80 3
HBC-101-H009 R
F-A,B,C Ft.Se l
3 HBC-101-H011 R
F-A,B,C F0. 00 l
3 HBC-101-H012 R
F-A,B,C FS. Se l
3 HBC-101-H014 R
F-A,B,C F8. 80 3
HCC-104-H001 R
F-A,B,C F0. 00 3
HCC-104-H002 V
F-A,B,C FO. 80 3
HCC-104-H003 M
F-A,B,C Fe. 00
[
3 HCC-104-H004 R
F-A,B,C F0. 00 l
3 HCC-104-H005 M
F-A,B,C FO. Se O
e
_...__.,_-.__~--._,,.,__e.
P:ge No.
27 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & CDP 940N
/"'y NUCLEAR CLASS 1, 2 & 3 COMPO>ENT SUPPORTS V
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 3
HCC-184-H006 V
F-A,B,C Ft. 90 3
HCC-104-H007 M
F-A,B,C FS. 00 3
HCC-104-H008 M
F-A,B,C FS. 00 3
HCC-104-H009 R
F-A,B,C FO. OS 3
HCC-104-H018 R
F-A,B,C FO. 80 3
HCC-104-H011 R
F-A,B,C FO. 80 3
HCC-104-H012 R
F-A,B,C FO. et 3
HCC-104-H013 R
F-A,B,C F0. 00 3
HCC-104-H014 R
F-A,B,C FO. Se 3
HCC-104-H015 M
F-A,B,C FO. 90 3
HCC-104-H016 R
F-A,B,C FS. OS 3
HCC-104-H017 R
HCC-104-H018 R
F-A,B,C FO. 80 3
HCC-104-H019 R
F-A,B,C FO. 00 3
HCC-104-H021 R
F-A,B,C FS. 80 3
HCC-104-H023 R
F-A,B,C FO. Se
~~
3 HCC-104-H024 R
F-A,B,'C
-~~
3 HCC-104-H025 R
F-A,B,C FS.90 3
HCC-104-H027 R
F-A,B,C FS. OS 3
HCC-104-H832 M
F-A,B,C FO. 80 3
HCC-104-He33 R
F-A,B,C FS. 80 3
HCC-104-H901 A
F-A,B,C FS. 80 3
HCC-104-H992 A
F-A,B,C F0.00 3
HCC-196-H001 R
F-A,B,C Ft. SS 3
HCC-106-H002 R
F-A,B,C Ft. SS 3
HCC-196-H003 R
F-A,B,C FS.SS 3
HCC-196-H004 R
F-A,B,C FO. 90 3
HCC-196-H005 R
HCC-196-H006 R
F-A,B,C FS. OS 3
HCC 186-H007 R
F-A,B,C FS. 90 3
HCC-196-H008 R
F-A,B,C Ft. Se
GBC-101-H001 V
F-A,B,C FS. 80 3
GBC-101-H002 V
F-A,B,C FS. 90 3
GBC-101-H003 V
F-A,B,C FS. 80 3
GBC-101-H028 V
F-A,B,C FS. 90 3
GBC-181-H029 V
F-A,B,C FS. OS 3
GBC-101-He30 V
F-A,B,C FS. 00 3
GBC-101-He31 V
F-A,B,C FS. 80 3
GBC-101-H032 V
F-A,B,C FO. 00 3
GBC-101-H033 V
F-A,B,C Ft. 80 3
GBC-101-He34 V
F-A,B,C FO.00 3
GBC-101-He36 V
F-A,B,C FO. OS 3
GBC-101-H037 Y
F-A,B,C FO. 00 3
GBC-101-H038 V
F-A,B,C FO. 80 3
GBC-101-H082 M
F-A,B,C FO. 00
P g3 No.
20 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 8 C0peq0N y
NUCLEAR CLASS 1, 2 8 3 COMPOPENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 3
GBC-101-H083 R
F-A,B,C FO. 80 3
GBC-101-H084 M
F-A,B,C FS. SS 3
GBC-101-H091 M
F-A,B,C FS. SS 1
3 GBC-101-H095 M
F-A,B,C Ft. SS 3
GBC-101-H096 M
F-A,B,C FS. 80 3
GBC-101-H097 M
F-A,B,C Ft. 80 3
GBC-101-H098 M
F-A,B,C Ft. 80 3
GBC-101-H197 M
F-A,B,C F0. 00 3
GBC-101-H198 R
F-A,B,C FO. 90 3
GBC-101-H110 M
F-A,B,C FO. 00 3
GBC-101-H119 M
F-A,B,C FS. 80 3
GBC-101-H120 M
F-A,B,C FS. Se 3
GBC-101-H121 M
F-A,B,C FS. 80 3
GBC-101-H128 M
F-A,B,C FS. 90 3
GBC-101-H129 M
F-A,B,C FO. 90 3
GBC-101-H132 M
F-A,B,C FS. 80 3
F-A,B,C Ft. 80 3
BBC-101-H137 M
F-4, B, C FS. OS 3
GBC-101-H138 M
F-A,B,C Ft. 80 3
GBC-101-H139 M
F-A,B,C FO.Se i
3 GBC-101-H140 M
F-A,B,C Ft. 80 3
GBC-101-H141 M
F-A,B,C FO. 80 3
GBC-181-H145 M
F-A,B,C FO. Se 3
GBC-101-H146 M
F-A,B,C Ft. 80 3
GBC-101-H147 R
F-A,B,C FO. 80 3
GBC-101-H156 M
F-A,B,C FS.OS 3
GBC-101-H157 M
F-A,B,C Ft. 80 3
GBC-101-H158 M
F-A,B,C Ft. SS 3
GBC-101-H162 M
F-A,B,C Ft. 80 3
F-A,B,C Ft. OS 3
GBC-101-H167 R
F-A,B,C FO. Se l
3 GBC-101-H168 M
F-A,B,C Ft. 80 3
GBC-101-H185 M
F-A,B,C Ft. OS 3
GBC-101-H186 M
F-A,B,C F0.00 3
GBC-101-H187 M
F-A,B,C Ft. 80 3
GBC-101-H188 M
F-A,B,C FS.00 3
GBC-101-H193 M
F-A,B,C FS. 80 3
GBC-101-H1%
V F-A,B,C FO. 80 3
GBC-181-H199 V
F-A,B,C FO. 80 3
GBC-101-H200 V
F-A,B,C FS. Se 3
GBC-116-H003 R
F-A,B,C FS. OS 3
GBC-116-H006 R
F-A,B,C FS. SS 3
GBC-116-H009 R
F-A,B,C FO. 00 3
GBC-116-H011 R
F-A,B,C FO. 80 3
GBC-116-H015 R
F-A,B,C F0. 00 3
GBC-116-H018 R
F-A,B,C FO. 80 3
GBC-116-H020 R
F-A,B,C FO. 80 l
l
P:go No.
29 TABLE 6 l
01/20/87 LIMERICK GENERATING STATION UNIT 1 & COMMON pd*
NUCLEAR CLASS 1, 2 & 3 COMPOENT SUPPORTS Selected for Examination - First Interval SYS NAME CLA55 HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 3
GBC-116-H022 R
F-A,B,C Ft. 80 3
GBC-116-H024 R
F-A,B,C F0. 00 3
GBC-116-H027 R
F-A,B,C FO. 80 3
GBC-116-H029 R
F-A,B,C FO. 80 3
GBC-116-He30 R
F-A,B,C FO. 80 3
GBC-116-H901 A
F-A,B,C FO. OS 3
GBC-116-H995 A
F-A,B,C Fe. 90 3
GBC-116-H908 A
F-A,B,C FO. 90 3
GBC-116-H910 A
F-A,B,C FO. 00
- RHR 3
GBC-192-H001 M
F-A,B,C FO. 90 3
GBC-192-H002 R
F-A,B,C FO. 90 3
GBC-102-H004 R
F-A,B,C FO. 00 3
GBC-102-H005 R
F-A,B,C Fe. 80 3
GBC-182-H006 M
F-A,B,C FO. OS 3
GBC-182-H007 R
F-A,B,C-Ft. OS --
3 GBC-192-H008 R
F-A,B,C FO. 80 3
GBC-192-H009 M
F-A,B,C FO. 80 3
GBC-193-H001 V
F-A,B,C FO. OS 3
GBC-193-H002 R
F-A,B,C FS. OS 3
GBC-193-H003 R
F-A,B,C F0. 80 3
GBC-193-H004 R
F-A,B,C FO. 06 3
GBC-103-H006 V
F-A,B,C FO. 80 3
GBC-193-H007 M
F-A,B,C Fe. Se 3
GBC-193-H008 R
F-A,B,C FO. OS
- RHR3W 3
HBC-091-H001 V
F-A,B,C FS. 80 3
HBC-091-H002 R
F-A,B,C FO. OS 3
HBC-091-H003 R
F-A,B,C FO. 80 3
HBC-091-H069 R
F-A,B,C Ft. 80 3
HBC-091-H070 R
F-A,B,C FO. OS 3
HBC-091-H071 R
F-A,B,C Ft. 80 3
HBC-091-H072 R
F-A,B,C FS. 80 3
HBC-091-H073 R
F-A,B,C FO.Se 3
HBC-091-H074 R
F-A,B,C FO.80 3
HBC-091-H075 R
F-A,B,C Ft. 80 3
HBC-091-H076 R
F-A,B,C FO. 80 3
HBC-091-H077 R
F-A,B,C Fe.80 3
HBC-091-H078 R
F-A,B,C FO. 80 3
HBC-091-H079 R
F-A,B,C FO. 00 3
HBC-091-H080 R
F-A,B,C FO. 00 3
HBC-091-H081 R
HBC-091-H082 R
F-A,B,C FO. 90 3
HBC-091-H083 R
F-A,B,C FO. 00 3
HBC-091-H084 R
F-A,B,C FO. 90
.n
,---------,,r
P:ge No.
30 TABLE 6 91/20/87 LIMERICK GENERATING STATION
)
UNIT 1 & COMMON NUCLEAR CLASS 1, 2 & 3 COMPONENT SUPPORTS o,
l Selected for Examination - First Interval l
l SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM l
3 HBC-991-H085 R
F-A,B,C FO. 80 3
HBC-991-H086 R
F-A,B,C FO. OS 3
HBC-891-H087 R
F-A,B,C FO. 00 3
HBC-091-H088 R
F-A,B,C FO. Se 3
HBC-891-H069 R
F-A,B,C FO. 80 3
HBC-991-H090 R
F-A,B,C FO. 80 3
HBC-091-H091 R
F-A,B,C FO. 80 3
HBC-991-H092 R
F-A,B,C FO. 90 3
HBC-091-H093 R
F-A,B,C FO. 90 3
HBC-991-H094 R
F-A,B,C FO. 90 3
HBC-891-H095 R
F-A,B,C FO. 80 3
HBC-091-HO%
R F-A,B,C FO. 90 3
HBC-891-H097 R
F-A,B,C FO. Se 3
HBC-091-H098 R
F-A,B,C Fe. 90 3
HBC-091-H099 R
F-A,B,C FO. 90 3
HBC-991-H100 R
F-A,B,C FO. OS 3
HBC-991-H191 R
F-A,B,C~
F0. 00 3
HBC-991-H192 R
F-A,B,C FS. 80 3
HBC-091-H193 R
F-A,B,C FO. 80 3
HBC-991-H194 R
F-A,B,C FO. 80 3
HBC-991-H195 M
F-A,B,C FO. 80 3
HBC-091-H196 R
F-A,B,C FO. 80 3
HBC-091-H197 R
F-A,B,C FS. 80 3
HBC-091-H198 R
F-A,B,C FO. 00 3
HBC-091-H199 R
F-A,B,C FO. Se 3
HBC-991-H110 R
F-A,B,C Ft. OS 3
HBC-091-H111 R
F-A,B,C FS. 80 3
HBC-991-H112 R
F-A,B,C
. FO. Se 3
HBC-091-H113 R
F-A,B,C FS. 80 3
HBC-991-H114 R
F-A,B,C FO. 80 3
HBC-991-H115 R
F-A,B,C FS. 80 3
HBC-091-H116 R
F-A,B,C FO. 80 3
HBC-991-H117 R
F-A, B, C FO. 80 3
HBC-991-H118 R
F-A,B,C Ft. 80 3
HBC-991-H119 R
F-A,B,C FS. OS 3
HBC-991-H120 R
F-A,B,C FS. 90 3
HBC-091-H121 R
F-A,B,C FS. 80 3
HBC-991-H122 R
F-A,B,C Ft. 90 3
HBC-091-H123 R
F-A,B,C FO. 80 3
HBC-991-H124 R
F-A,B,C F0. 00 3
HBC-991-H125 R
F-A,B,C FO. 80 3
HBC-091-H126 R
HBC-991-H127 R
F-A,B,C FS. 80 3
HBC-991-H128 R
F-A,B,C FO. 80 3
HDC-091-H129 R
F-A,B,C FO. 80 3
HBC-991-H130 R
F-A,B,C FO. 80 3
HBC-091-H131 R
F-A,B,C FO. Se 3
l P:ge No.
31 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 4 C0f910N
(%
NUCLEAR CLASS 1, 2 4 3 COMPONENT SUPPORTS t
Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATG ITEM 3
HBC-091-H132 R
F-A,B,C FS. 80 3
HBC-091-H133 R
F-A,B,C FS. 80 3
HBC-091-H148 R
F-A,B,C Ft. OS 3
HBC-091-H149 R
F-A,B,C FO. 90 3
HBC-091-H150 R
F-A,B,C Ft. 80 3
HBC-091-H151 R
F-A,B,C FS. 80 3
HBC-091-H152 R
F-A,B,C FS. OS 3
HBC-091-H153 R
F-A,B,C FO. OS 3
HBC-091-H154 R
F-A,B,C FO. 80 3
HBC-091-H155 R
F-A,B,C FO. 00 3
HBC-091-H156 R
F-A,B,C FO. 00 3
HBC-091-H157 R
F-A,B,C FO. OS 3
HBC-091-H158 R
F-A,B,C Fe. OS 3
HBC-091-H159 R
F-A,B,C FO. 80 3
HBC-091-H160 R
F-A,B,C Fe. 80 3
HBC-091-H162 R
F-A,B,C FO. 80 3
HBC-091-H163 R
F-A,B,C - Ft.Se ~
3 HBC-091-H164 R
F-A,B,C FO. 80 3
HBC-091-H165 R
F-A,B,C FS. 80 3
HBC-091-H166 R
F-A,B,C Ft. SO O
3 HBC-091-H169 R
F-A,B,C F0. 00 3
HBC-091-H170 R
F-A,B,C Ft. OS 3
HBC-091-H171 R
F-A,B,C Fe. 80 3
HBC-091-H172 R
F-A,B,C FO. 80 3
HBC-091-H174 M
F-A,B,C FS. Se 3
HBC-091-H991 A
F-A,B,C FS. 80 3
HBC-180-H001 R
F-A,B,C FO. 80 3
HBC-182-H001 R
F-A,B,C FO. 90 3
HBC-182-H901 A
F-A,B,C FS. 80 3
HBC-280-H001 R
F-A,B,C FO. OS 3
HBC-280-H002 R
F-A,B,C FS. 80 3
HBC-280-H003 R
F-A,B,C Ft. OS 3
HBC-280-H004 M
F-A,B,C FS. 00 3
HBC-286-H005 R
F-A,B,C FS. 80 3
HBC-280-H006 R
F-A,B,C FS. 80 3
HBC-280-H007 R
F-A,B,C Ft. 80 3
HBC-280-H008 R
F-A,B,C Ft. 80 3
HBC-280-H010 R
F-A,B,C FO. 80 3
HBC-282-H001 R
F-A,B,C FS. 80 3
HBC-282-H002 R
F-A,B,C FO. 80 3
HBC-282-H003 R
F-A,B,C FS. 80 3
HBC-282-H004 R
F-A,B,C F0. 00 3
HBC-282-H005 R
F-A,B,C FO. OS 3
HBC-282-H006 R
F-A,B,C FO. 00 3
HBC-507-H001 V
F-A,B,C FO. Se 3
HBC-507-H002 R
F-A,B,C FO. 00 3
HBC-507-H003 R
F-A,B,C FS. 80 0
P ge No.
32 TABLE 6 01/20/87 LIMERICK GENERATING STATION UNIT 1 & C0 pet 0N NUCLEAR CLASS 1, 2 8 3 COMPODENT SUPPORTS Selected for Examination - First Interval SYS NAME CLASS HANGER NUMBER HGR TYPE CATG CODE CATS ITEM 3
HBC-387-H162 R
F-A,B,C Ft. 80 3
HBC-507-H163 R
F-A,B,C Ft. 80 3
HBC-507-H164 M
F-A,B,C F0. 00 3
HBC-507-H169 R
F-A,B,C F8. 80 3
HBC-507-H171 R
F-A,B,C F0. 00
[
3 HBC-507-H172 M
F-A,B,C FS. 80 3
HBC-507-H173 R
F-A,B,C FO. Se 3
HBC-507-H991 A
F-A,B,C FO. 00 3
HBC-508-H001 R
F-A,B,C FO. OS 3
HBC-508-H002 R
F-A,B,C FO. 90 3
HBC-508-H003 V
F-A,B,C FO. Se 3
HBC-508-H004 R
F-A,B,C F0. 00 3
HBC-508-H005 R
F-A,B,C Fe. Se 3
HBC-508-H006 V
F-A,B,C FO. 90 3
HBC-508-H007 R
F-A,B,C F8. 80 3
HBC-508-H901 A
F-A,B,C F0. 80 3
HBC-537-H002 R
F-A,B,C FS.80 3
HBC-537-H931 A
F-A,B,C FO. 80 0
1
.lO l
i -.
_ _.