Amend 130 to License NPF-1,revising Tech Spec Section 3.7.1.4 to Reflect Increase in Min Water Level Required to Be Maintained in Condensate Storage Tank
ML20209B822
Person / Time
Site: Trojan File:Portland General Electric icon.png
(NPF-01-A-130, NPF-1-A-130)
Issue date: 04/22/1987
From: Knighton G
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20209B779 List:
References
NUDOCS 8704280522
Download: ML20209B822 (5)


Text

i.

paucg y

fg UNITED STATES y

g NUCLEAR REGULATORY COMMISSION 5+

j WASHINGTON, D. C. 20555 o,

0

'....+4 PORTLAND GENERAL ELECTRIC COMPANY THE CITY OF EUGENE, OREGON PACIFIC POWER AND LIGHT COMPANY DOCKET NO. 50-344 TROJAN NUCLEAR PLANT AMENDMENT'T0 FACILITY OPERATING LICENSE Amendment No.130 License No. NPF-1 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Portland General Electric Company, et al., (the licensee) dated October 29, 1985, as revised January 9, 198T complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and W

E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

-il i

8704280522 870422 s -

PDR ADOCK 05000344 p

PDR

, l

l

\\

.-.,..s..,,,,.m.._...,_,._,,

my,.,,

ja arc,

o pf

?g UNITED STATES y'

g NUCLEAR REGULATORY COMMISSION

'f WASHINGTON, D. C. 20$55 3 O'

~

i o$

+....

ATTACHP'ENT TO LICENSE AMENDMENT No.130 TO FACILITY OPERATING LICENSE NO. NPF-1 DOCKET NO. 50-344 Revise Appendix A as follows:

Remove Paces Insert Pages 1

TS 3/4 7-8_

TS 3/4 7-8

~

B 3/4 7-?

8 3/4 7-2 4

w.

6 h

o

.... 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-1 is bereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 130, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifica,

tions, except where otherwise stated in specific license

. conditions.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

/

/

C George W.j nighton, Di.

tor Project ufrectorate Division of Reactor Projects-III/IV/V and-Special Projects

Attachment:

Changes to the Technical Specificatitas Date of Issuance: April 22,1987 0

D

.g r

y--

. - -- --. l a

PLANT SYSTEMS CONDENSATE STORAGE TANK LIMITING CONDITION FOR OPERATION

\\

3.7.1.4 The condensate storage tank shall be OPERABLE with a minimum contained volume of 239,000 gallons of water.

APPLICABILITY: MODES 1, 2 and S.

ACTION:

With the condensate storage tank inoperable, within 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> either:

Restore the condensate storage tank to OPERABLE status or be a.

in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, or b.

Demonstrate the OPERABILTTY of the Service Water System as a backup supply to the auxiliary feedwater pumps and restore the condensate storage tank to OPERABLE status within 7 days or be in HOT SHUTDOWN within the next 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />.

SURVEILLANCE RE0VIREMENTS 4.7.1.4.1 The condensate storage tank shall be demonstrated OPERABLE at least once per 12~ hours by verifying the water level is within its limit when the tank is the supply source for the auxiliary feedwater pumps.

4.7.1.4.2 The Service Water System shall be demonstrated OPERABLE at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> by verifying that at least one Service Water System train is operating and that the Service Water System-feedwater isolation valves are either open or OPERABLE whenever the Service Water System is the supply source for the auxiliary feedwater pumps.

TROJAN-UNIT 1 3/4 7-8 Amendment No. 130

L PLANT SYSTEMS BASES-U = Maximum number of inoperable safety valves per operating steam line 109 = Power Range Neutron Flux-High Trip Setpoint for 4 loop operation i

75 - Maximum percent of RATED THERMAL POWER permissible by j

j P-8 Setpoint for 3 loop operation i

X = Total relieving capacity of all safety valves per steam 6

line in lbs/ hour (4.12 x 10 lbs/hr)

Y = Maximum relieving cgpacity of any one safety valve in.

I lbs/ hour (9.27 x 10 lbs/hr) t 3/4.7.1.2 AUXILIARY FEEDWATER SYSTEM i

The OPERABILITY of the auxiliary feedwater systems ensures that the Reactor Coolant System can be cooled down to less than 350*F from normal operating conditions in the event of a total loss of off-site power.

Either of the two pumps has the required capacity to provide sufficient feedwater flow to remove reactor decay heat and reduce the RCS temperature to 350*F where the Residual Heat Removal System may be placed into operation for continued cooldown.

i The electric auxiliary feedwater pump is not safety grade and is used during startup and shutdown to preclude unnecessary wear on the safety-related pumps. The electric auxiliary feedwater pump has approximately the same rated capacity as either of the safety-related pumps.

4 With no auxiliary feedwater pumps OPERABLE, power is reduced to 35 per-cent, because at this power level the feedwater regulating valves should be in AUTO and the plant in a stable low power mode which does not require auxiliary feedwater.

l 3/4.7.1.3 (deleted) i 3/4.7.1.4 CONDENSATE STORAGE TANK The OPERABILITY of:the condensate storage tank with the minimum water volume ensures that sufficient water is available to maintain the RCS at HOT STANDBY conditions for 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> with steam discharge at atmosphere concurrent with total loss of off-site power. The mini-1 mum contained volume accounts for:

(1) water volume required to be delivered to the steam generators (196,000 gallons), (2) unusable volume in the bottom of the tank (27,700 gallons), and (3) instrument error (14,400 gallons), rounded off to 239,000 gallons.

TROJAN-UNIT 1 8 3/4 7-2 Amendment No. 57, 93, 130.