Text
y
..s NOC-AE-000569 P ;e 1 of 4 4
ATTACHMENT 2 MARKED UP PAGES TO THE TECHNICAL SPECIFICATIONS l
l 9907070167 990624 PDR ADOCK 05000498 P
NOC-AE-000569 1
Pctge 2 of 4 PROPOSED CHANGES TO TECHNICAL SPECIFICATIONS
Reference:
letter from T.H. Cloninger to the Nuclear Regulatory Commission Document Control Desk dated June 7,1999 (NOC-AE-000471)
The Technical Specification page listed below is marked-up to identify the proposed changes associated with this submittal and is enclosed in this attachment. The attached pages (including insens) supercede and replace the marked-up pages submitted in the referenced letter above.
P.aget 6-21
fErA&000569 Attainmt 2 P ;e 3 of 4 4
ADMINTSTRATIVE CONTROLS HONTHLY OPERATING REPORTS 6.9.1.5 Routine reports of operating statistics and shutdown experience, including documentation of all challenges to the PORVs or safety valves, shall be submitted on a monthly basis to the Director, Office of' Resource Manage-ment, U.S. Nuclear Regulatory Commission Washington, D.C.
20555, with a copy to the Regional Administrator of the Reglonal Office of the NRC, no later than the 15th of each month following the calendar month covered by the report.
CORE OPERATING LIMITS REPORT 6.9.1.6.a Core operating limits shall be estabitshed and documented in the CORE OPERATING LIMITS REPORT before each reload cycle, or any part of a reload cycle for the following:
NNI
,gh. Moderator Temperature Coefficient BOL and EOL limits, and 300 ppm surveillance limit for Specification 3/4.1.1.3, q,2'.
Shutdown Bank Insertion Limit for Specification 3/4.1.3.5, fr. Control Bank Insertion Limits for Specification 3/4.1.3.6,
- 44. Axial Flux Difference limits and target band for Specification 3/4.2.1, Heat Fg) Hot Channel Factor, K(Z), Power Factor Multiplier, 7 S'.
and (F forSpecification3/4.2.2,and y
S fr. Nuclear Enthalpy Rise Hot Channel Factor, and Power Factor 1
Hultiplier for Specification 3/4.2.3.
WW[
---9 The CORE OPERATING LIMITS REPORT shall be maintained available in the Control Room.
6.9.1.6.b The analytical methods used to determine the core operating limits shall be those previously reviewed and approved by the NRC in:
1.
WCAP 9272-P-A, ' WESTINGHOUSE RELOAD SAFETY EVAt.UATION HETHODOLOGY", July,1985 (H Proprietary).
(Hethodology for Specification 3.1.1.3 - Moderator Temperature Coefficient 3.1.3.5 - Shutdown Rod Insertion Limit, 3.1.3.6 -
Control Bank Insertion Limits, 3.2.1 - Axial Flux Difference, 3.2.2 - Heat Flux Hot Channel Factor, and 3.2.3 - Nuclear EnthalpyS, Rise Hot Channel Factor >K 2.g sq l_imc-ts 2.2 - Lieg atdy 3
Sy5km 5608605 And
- 3. 2. 5' - DN8 Param2.fersd 1.A.
WCAP 12942-P-A,
- SAFETY EVALUATION SUPPORTING A MORE NEGATIVE EOL H0DERATOR TEMPERATURE COEFFICIENT TECHNICAL SPECIFICATION FOR THE SOUTH TEXAS PROJECT ELECTRIC GENERATING STATION UNITS 1 AND 2."
DM b D
4T Unit 1 - Amendment No. G,-@, % '$6-SOUTH TEXAS - UNITS 1 & 2 6-21 Unit 2 - Amendment No. -15 1+, %
f o
NOC-AE-000569 Page 4 of?4 Insert 4 1.
Safety limits for thermal power, pressurizer pressure, and the highest operating loop coolant temperature (Toyg) for Specification 2.1, 2.
Limiting Safety System Settings for Reactor Coolant Flow-Low Loop design flow, Overtemperature AT, and Overpower AT setpoint parameter values for Specification 2.2, l
Insert 5 i
9.
DNB related parameters for Reactor Coolant System T,yg, Pressurizer Pressure, and the Minimum Measured Reactor Coolant System Flow for
\\
Specification 3/4.2.5.
l l
Insert 6 1.B.
WCAP-8745-P-A, " Design Bases for the Thermal Overpower AT and Thermal Overtemperature AT Trip Functions," September 1986 (Westinghouse Proprietary Class 2) l
!