ML20207T798

From kanterella
Jump to navigation Jump to search
Forwards Insp Repts 50-424/87-16 & 50-425/87-12 on 870217-20.No Violation or Deviation Noted
ML20207T798
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 03/05/1987
From: Brownlee V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: James O'Reilly
GEORGIA POWER CO.
Shared Package
ML20207T799 List:
References
NUDOCS 8703240355
Download: ML20207T798 (3)


See also: IR 05000424/1987016

Text

m

A

-

-

.

.

MAR 0 51987

Docket Nos. 50-424, 50-425

License Nos. NPF-61, CPPR-109

Georgia Power Company

ATTN: Mr. James P. O'Reilly

Senior Vice President-

Nuclear Operations

}

P. O. Box 4545

Atlanta, GA 30302

Gentlemen:

SUBJECT: NRC INSPECTION REPORT NOS. 50-424/87-16 AND 50-425/87-12

This refers to the Nuclear Regulatory Commission (NRC) inspection conducted by

R. W. Newsome on February 17-20, 1987.

The inspection included a review of

activities authorized for your Vogtle facility.

At the conclusion of the

inspection, the findings were discussed with those members of your staff

identified in the enclosed inspection report.

Areas examined during the inspection are identified in the report.

Within

these areas, the inspection consisted of selective examinations of procedures

and representative records, interviews with personnel, and observation of

activities in progress.

Within the scope of the inspection, no violations or deviations were identi-

fled.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2,

Title 10, Code of Federal Regulations, a copy of this letter and its enclosure

will be placed in the NRC Public Document Room.

!

Should you have any questions concerning this letter, please contact us.

Sincerely,

8703240355 870305

PDR

ADOCK 05000424

G

Pon

Virgil L. Brownlee, Chief

Reactor Projects Branch 2

Division of Reactor Projects

Enclosure:

NRC Inspection Report

cc w/ enc 1:

(See page 2)

j

!

lll

l

.Z:F o/

-

.-

.

,

.

Georgia Power Company

2

~ MAR 0 5 E67

cc w/ encl:

R. E. Conway, Senior Vice President &

Project Director

C. Whitney, General Manager Project

Support

P. D. Rice, Vice President, Project

Engineering

R. H. Pinson, Vice President, Project

Construction

C. W. Hayes, Vogtle Quality

Assurance Manager

,

G. B. Bockhold, General Manager,

Nuclear Operations

L. Gucwa, Manager, Nuclear Safety

and Licensing

J. A. Bailey, Project Licensing

Manager

B. W. Churchill, Esq., Shaw,

Pittman, Potts and Trowbridge

J. E. Joiner, Troutman, Sanders,

Lockerman and Ashmore

J. G. Ledbetter, Commissioner,

Department of Human Resources

C. H. Badger, Office of Planning

and Budget

D. Kirkland, III, Counsel,

Office of the Consumer's Utility

Council

D. Feig, Georgians Against

Nuclear Energy

M. B. Margulies, Esq., Chairman,

Atomic Safety and Licensing Board

Panel

Dr. O. H. Paris, Administrative Judge

Atomic Safety and Licensing Board

Panel

G. A. Linenberger, Jr., Administrative Judge

Atomic Safety and Licensing Board

Panel

bec w/ encl:

(Seepage 3)

.

.

-

.

-

,

MAR 0 5 ggg ,

Georgia Power Company-

3

bec w/ encl:

E. Reis, OGC

W. M. Hill, IE

M. Miller,-NRR-

W. Brach,_EDO

M. Sinkule, RII

E. Christnot, RII

NRC Resident Inspector

Document Control Desk

State of Georgia

,

e

R ew ome:cdg

Llake

A erdt

MSinkule

02hs/87

/ok/87

0 / 3 /87

/4 /87

.