Ack Receipt of 860904,30 & 1201 & s Re Violation Noted in Insp Repts 50-369/86-16 & 50-370/86-16.Violation Re Containment Leak Rate Warranted.Submittal of Corrective Action Plan W/Alternative Test Program Proposal Discussed
ML20207T232
Person / Time
Site: McGuire, Mcguire  
Issue date: 02/24/1987
From: Reyes L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Tucker H
DUKE POWER CO.
References
IEIN-85-071, IEIN-85-71, NUDOCS 8703230332
Download: ML20207T232 (2)


See also: IR 05000369/1986016

Text

v .

,-

--

S

&

FEB 2 41987

_ Duke Power Company' .

.

p-N: Mr. H..B. Tucker, Vice President .

-

Nuclear Production Department

422 South Church Street

Charlotte, NC 28242

Gentlemen:

.

1

-

SUBJECT: REPORT NOS. 50-369/86-16 AND 50-370/86-16

I

-Thank you for- your' responses of September 4, September 30, and December 1,1986,

and the Ladditional information needed to complete our evaluation prov, dad by

telephone on January 27, 1987, relating to our Notice of Violation issued on

i

' August 5,1986 concerning activities conducted at your McGuire facility.- We

'j

conclude that the violation issued in the Notice of violation for McGuire Unit 2

L

is correct.

The change in leak rate resulting from repairs or' adjustments made

l

to the fuel transfer. tube blind flange and containment building equipment hatch

l

l'

prior; to the Type A test was not measured.

Consequently the adjustment to

determine the "as is" -(also called "as found") overall- containment leak rate can

not be made for these components.

While the violation is worded to emphasize the requirement to determine the "as

found" containment leak rate, we consider that this requirement also incorporates

the need to establish a quality program which controls safety related activities

to ensure that the required local leak rates are measured, the results document-

ed, and the change in leakage used to determine the overall centainment integrat-

ed leak rate for the "as found" condition.

A program for control of activities

to measure the change in leakage resulting from repairs or adjustments to the

containment boundary was not implemented for the Unit 2 outage.

l

Failure to measure the leakage corrections made to the containment boundary prior

to the Type A test raises the question of whether the "as found" containment

,

integrated leakage rate is a passed or " failed" leak rate.

Your investigation indicates an overall containment integrated leakage rate for

the "as found" condition of 0.99 La.

The acceptance limit applicable to the "as found" leak rate whether performed in

the "as found" containment condition or calculated by accounting for the change

in -leakage rate made before the Type A test is 0.75 La as specified in Para-

graph III.A.5(b) of Appendix J.

This position is further supported by Para-

graphs III.A.1(a) and III.A.6 of Appendix J.

Consequently, we have classified the May 20 - 26,1986 Unit 2 Type A test as a

" failed" integrated leak rate test for the "as found" containment condition.

Therefore the requirements of Paragraph III.A.6. of Appendix J are applicable.

W 'E M N IE

O

de

Ze os

__-_-_

-- --

T

FEB 2 41987 -

m

s

Duke Power Company

?.

Our findings in no way preclude your option to submit a Corrective Action Plan

with an alternative test program proposal along with a request for exemption from

the failed as found" containment integrated leak rate classification for NRC

staff review. The reasons for this option are stated in IE Notice 85-71.

We appreciate your cooperation in this matter.

Sincerely,

Original Signed by

Luis A. Reyes

Luis A. Reyes, Acting Director

Division of Reactor Projects

[ L. McConnell, Station Manager