l-l SEABROOK STATION UNIT 1 PREOPERATIONAL LEAKAGE REDUCTION TRACKING AND HISTORY REPORT FOR CONTAINMENT BUILDING SPRAY COMBUSTIBLE GAS CONTROL - HYDROGEN DETECTION CHARGING AND REACTOR COOLANT PUMP SEAL INJECTION RESIDUAL HEAT REMOVAL SAFETY INJECTION PRIMARY SAMPLE AND POST ACCIDENT SAMPLE SYSTEMS MARCH 11, 1987 8703180424 870316

-PDR ADOCK 05000443 E

PDR

SUMMARY

Following the accident at Three Mile Island, NUREG 0737 required that a program be developed to reduce leakage from systems outside containment that may contain primary coolant or other highly radioactive liquids or gases. The program at Scabrook Station includes.the following systems:

o Residual Heat Removal (RH) o

-Containment Building Spray (CBS)

Charging and Reactor Coolant Pump Seal Injection (CS) o o

Safety Injection (SI)

Primary Coolant Sampling including the Post-Accident Sampling System (SS) o Combustible Gas Control - Hydrogen Detection (CGC) o Liquid systems are visually inspected at operating temperatures and pressures and leakage noted. Helium leak detection methods are used-to determine the CGC system leakage. These inspections are performed at routine intervals by system engineers during pump and valve testing, primary sampling, or other times established by surveillance procedure. The leakage reduction program will be continued through the life of the plant. Inspection frequencies shall be at least once per 18 months.

All practical leak reduction measures are implemented when leakage is found.

Repair priorities are assigned depending on the amount of leakage and plant operating conditions.

The enclosed preoperational data reflects the results of the routine surveillances as well as results from general housekeeping inspections by plant operators and others. This data-is maintained on a computer-based tracking program which serves as a management summary and trending tool to maintain leakage as low as possible.

l...

~

.O.

J LEAKAGE REDUCTION TRACKING AND HISTORY REPORT EXPLANATION OF REPORT COLUMNS-Column Description

-SYS System Code I

CD Component Code.

COMP ID Component Identification TR Train DESCRIPTION Component Description LEAK TY Leak Type LEAK AS F Leakage As Found Measurement LEAK AS L Leakage As Left Measurement WR NUMBER Work Request Document Number DT ID

.Date Leakage Identified DT COM Date Work and Documentation Clooed Out-ACTION TAKEN Description of Work Performed REMARKS Status and Coauments ABBREVIATIONS CBS - Containment Building Spray System P - Pump Equipment Code.

CGC - Combustible Gas Control System PPG - Piping CS - Charging and Reactor Coolant Pump RC - Reactor Coolant System Seal Injection (Chemical and Volume RH - Residual Heat Removal System j-Control) System SI - Safety Injection System DPM - Drops per Minute SS - Sample and Post Accident DR - Drain Sample System FCV - Flow Control Valve THD - Threaded FV - Flow Valve V - Valve Equipment Code GPM - Gallons per Minste VLV - Valve i

MECH JT - Mechanical Joint NOTES 1.

Seat leakage of vent or drain valve detected by leakage or boric acid crystal build-up at capped connection downstream of valve. Cap not removed to measure seat leakage.

2.

Leakage not measured.

3.

Hydrogen detection valve has small leakage around a body gasket detected by helium mass spectometer. The audible output of the detector changed, but the detector meter did not register a measurable change from back-ground, (indicating a very small or negligible leak). The valve will not be repaired, but will be trended during future surveillances.

,,.r

-c.-

y _. - - - - -..,, - -.....,,..,.,,,,,,,

_, _ ~. -,. -., - - -.,..

seeeeeeeeeeense LEAKAGE REDUCTION TRACKING AND HISTORY REPORT eteessnestettes SYS CD COMP ID TR DESCRIPTION LEAK TY LK AS F LK AS L WR NUMBER DT ID DT COM ACTION TAKEN REMARKS j

CBS P 9A A CENTRIFUSAL PUMP SEAL (1 DPM 0 86 WOO 7358 860903 860929 REWORKED SEAL PIPING CONN COMPLETED CBS P 9A A CENTRIFU6 R PUMP SEAL 60 DPM 86W008498 861003 RENDRkED SEAL PIPING CONN OPEN - FIELD WORK COMPLETE CBS P 9B B CENTRIFUGAL PUMP SEAL (1 DPM 0 86 WOO 7359 860903 861204 REWORKED SEE PIPING CONN COMPLETED CSS V 0027 8 3/4' GLOBE VR VE PACKING (I DPM 0 86 WOO 7357 860903 870227 ADJUSTED PACKING COMPLETED CBS V 0044 B 6' 6 ATE VALVE MECH JT (1 DPM 0 86W008690 861009 861208 REWDRKED LEAK-OFF PLUG COMPLETED CBS V 0053 B 6' 6 ATE VRVE PACKING (I DPM 0 86W005768 860723 860908 ADJUSTED PACKING COMPLETED CBS V 0062 8 3/4' I l' RELIEF BELLOWS NOTE 2 0 86W006156 860730 861015 GEPLACED VALVE COMPLETED CBS V 0094 8 3/4" I l' RELIEF SEAT NOTE 2 0 86 WOO 9866 861118 870227 LAPPED DISC AND SEAT COMPLETE CBS V 0096 A 3/4' I l' RELIEF SEAT NOTE 2 0 86W010247 861202 661219 LAPPED DISC AND SEAT COMPLETED CBS V 0102 A 3/4' 6tGBE VALVE BODY (1 DPM 0 86 WOO 5tl7 860711 860918 REPLACED BODY-BONNET 6ASKET COMPLETED CGC V 0062 B 3/4' VAC RELIEF BODY NOTE 3 NOTE 3 N/A 870308 N/A NONE - SEE NOTE 3 NO WORK PERFORMED - TREND ONLY CS V 0067

- 3/4' 6 LOBE VALVE PACKING (1 DPM 0 86W008133 860924 861119 ADJUSTED PACKING COMPLETED CS V 0068

- 3/4' 6 LOBE VALVE PACKIN6 (1 DPM 0 86W008132 860924 861119 ADJUSTED PACKIN6 COMPLETED CS V 0121

- 3/4' 6 LOBE VRVE SEAT I SPM 0 86W010254 861202 870113 REPLACED INTERNALS COMPLETED CS V 0124

- 3/4' 6LDBE VALVE SEAT (1 DPM 0 86W008456 861002 861208 CLEANED DR PP6/ REPLACED CAP COMPLETED CS V 0132

- 2' 6 LOBE VALVE PACKING (1 DPM 0 86W008452 861002 861119 ADJUSTED PACKING COMPLETED CS V 0134 2' GLOBE VALVE PACKING (1 DPM 0 86h008451 861002 861119 ADJUSTED PACKING COMPLETED CS V 0153

- 2' NEEDLE VRVE PACKING (1 DPM 0 86W008461 861002 861208 ADJUSTED PACKING COMPLETED CS V 0157

- 2' NEEDLE VALVE PACKING (1 DPM 86W008460 861002 OPEN CS V 0158

- 2' GLOBE VALVE PACKING (I DPM 86W008459 861002 DPEN CS V 0162

- 2' GLOBE VALVE PACKING 30 DPM 0 86W010290 861203 870224 ADJUSTED PACKING COMPLETED CS V 0162

- 2' GLOBE V RVE PACKING 5 DPM 87W001282 870211 ADJUSTED PACKIN6 OPEN - FIELD NORK COMPLETE CS V 0166

- 2' 6 LOBE VALVE PACKING (1 DPM 0 86 WOO 6612 860814 860908 CLEANED V RVE ONLY COMPLETED CS V 0167

- 2' 6 LOBE VALVE PACKING (I DPM 0 86 WOO 6449 861002 861229 ADJUSTED PACKING COMPLETED CS V 0167

- 2' ELDEE VALVE PACKING 4 DPM 87W002034 870120 OPEN CS V 0194

- 3' GLOBE VRVE PACKING (1 DPM 0 87W000339 870111 870224 REPLACED PACKIN6 COMPLETED CS V 0205

- 2' GLDEE VALVE PACKING (1 DPM 0 86WOOB143 860924 870210 REPLACED PACKING COMPLETED CS V 0205

- 2' GLDEE VALVE PACKING (1 DPM 0 86W010198 861126 870227 ADJUSTED PACKING COMPLETED CS V 0214

- 3/4' 6 LOBE VRVE PACKING (1 DPM 0 86W010197 861126 870224 ADJUSTED PACKIh6 COMPLETED CS V 0218 B 3/4' 6 LOBE VALVE PACKING (I DPM 0 86W008496 861003 861208 ADJUSTED PACKING COMPLETED CS V 0218 B 3/4' 6L0EE VALVE PACKING (1 DPM B7W000827 870127 0 PEN CS V 0525 A 3/4' 6 LOBE V RVE PACKING (1 DPM 0 86W008497 861002 861208 ADJUSTED PACKING C0CLETED CS V 0525 A 3/4' GLOBE VALVE PACKING (1 DPM A 000818 870127 DPEN CS V 0580

- 3/4' 6 LOBE VALVE SEAT (1 DPM 0 B6W008448 861002 861208 CLEANED DR PP6/ REPLACED CAP COMPLETED CS V 0602 A

l' 6 LOBE VALVE PACKING (1 DPM 0 86W008497 861002 861208 ADJUSTED PACKING C00LETED CS V 0761

- 3/4* GLOBE VALVE SEAT NOTE 1 87W001077 870205 DPEN CS V 07i5

- 2' 6L0EE VALVE PACKING (1 DPM 0 86W008450 861002 861212 ADJUSTED PACKIN6 COMPLETED CS V 0795

- 2' 6 LOBE VALVE FACKING (I DPM 0 87W000615 870120 870224 REPLACED PACKING COMPLETED CS V 0869 B 3/4' 6 LOBE VALVE PACl!NG (1 DPM 0 86W008496 861003 861208 ADJUSTED PACKING COMPLETED CS V 0869 9 3/4' 6 LOBE VR VE PACKING (1 DPM 87W000826 870127 OfEN C5 V 0871 B 3/4' GLDEE VALVE PACKING (1 DPM 0 86W008496 861003 861208 ADJUSTED PACKING COMPLETED CS V 0871 8 3/4" 6LO6E VALVE PACKING (1 DPM 87W000825 870127 DPEN CS V 0873 A 3/4' 6LDLE VALVE FACKING (I DPM 0 86W008160 860924 861200 ADJUSTED PACKING COMPLETED CS V 0873 A 3/4' 6LO5E VRVE PACKING (1 DPM 0 86W008497 861002 861200 ADJUSTED PACKING COMPLETED CS V 0873 A 3/4' 6LD5E VALVE PACklNG (I DPM 87 WOO (81? 870127 OPEN CS V 0875 A 3/4' GLOBE VALVE PACKING (1 DPM 0 86W006497 861002 861200 ADJUSTLD PACKING COMPLETED CS V 0875 A 3/4' 6 LOBE VALVE PAtk!NG (1 DPM B7W000820 870127 0 FEN CS V 0999

- 3I4' 6 LOBE V RVE PACKING (1 DPM 0 86W010196 661126 870224 ADJUSTED PACKING CGMPLETED PC V 0342

- 1/2' 6LDBE VALVE PACKING 3 DPM 87W002389 870307 OPEN 5H V 0008 A 3/4' 6LDEE VALVE SEAT NOTE 1 86W009540 861106 OPEN RH V 0016 A 3/4' 6L0bE VRVE PACKING (1 DPM 0 86W008058 860918 861208 ADJUSTED PACKING COMPLETED St V 0017 B 3/4' 6L05E VALVE PACKING (1 DPM 0 86 WOO 7880 860916 870227 ADJUSTED PACKINS COMPLETED RH V 0023 8 1/2' GLOBE VAlkE PACKING (1 DFM 0 86 WOO 7878 860916 861017 ADJUSTED PACKING COMPLETED Sri V 0041 B 1/2' 6LDEE VALVE PACKINS (1 DPM 0 86 WOO 7883 860916 861016 ADJUSTED PACKING C0MPLETED RH V 0042 B 1/2' GLDEE VALVE PACKING (1 DPM 96W009698 861112 ADJUSTED FACKING DPEN - FIELD WORK COMPLETE mununun LE2 AGE REDUCTION TRACKING AND HISTORY REPORT stuumusen SYS CD COMP 10 TR DESCRIPT10N LEAK TV LK AS F LK AS L WR NUMBER DT ID DT COM ACTION TAFEN REMARKS O

V 0044 B 3/4' 6 LOBE V R VE SEAT NOTE 1 86W011005 861230 0 FEN O

V C 78 8 3/4' 6 ATE VALVE PACKING (1 DPM 0 86 WOO 7879 860916 861024 ADJUSTED PACKIN6 COMPLETED Q

V 0085 A 3/4* GATE VALVE SEAT (1 DPM (1 DPM 86W008052 860918 861104 ADDED THD SEALANT TO DR CAP COMPLETED 0

V 0087 A 3/4' GATE VALVE PACKIN6 (1 DPM 0 86W008059 860918 861204 ADJUSTED PACKING COMPLETED D

V 0104 A 3/4' 6 LOBE VALVE SEAT NOTE 1 87W000654 870121 0 FEN O

V 0120 B 3/4" 6 ATE VALVE SEAT NOTE I 86W009003 860918 ADJUSTED PACKING OFEN - FIELD WORK COMPLETE O

V 0121 A 3/4' 6 ATE VALVE SEAT NOTE I 0 86 WOO 9053 660918 0 FEN O

V 0140 8 t/2' 6 LOBE VALVE 6 EAT NOTE 2 0 86W011004 861230 870224 CLOSED VALVE REPLACED CAP COMPLETED - VLV FOUND CRACKED DPEN RH V 0141 8 t/2' 6 LOBE VALVE SEAT NOIE 2 0 86W011003 861230 870224 CLOSED VALVE REPLACED CAP COMPLETED - VLV FOUND CRACKED OPEN O

V 0148 A I/2' 6 LOBE VALVE MECH JT (1 DPM 0 86 WOO 9057 860918 861029 TISHTENED SWA6E LOK FITTING COMPLETED RH V 0150 A t/2' GLOBE VALVE MECH JT (l.DPM 0 86W008057 860918 861029 TISHTENED SWA6E LOK FITTING COMPLETED RH V 0160 A 3/4' GLOBE VALVE PACKING (1 DPM 0 86W008061 860918 861112 ADJUSTED PACKIN6 COMPLETED RH V 0162 8 3/4' 6 LOBE VALVE PACKING (1 DPM 0 86W007882 860916 861016 ADJUSTED PACKING COMPLETED O

V 0162 8 3/4' 6 LOBE VALVE PACKING (1 DPM 0 86 WOO 9699 861112 861204 ADJUSTED PACKING COMPLETED RH V 0164 8 3/4' 6 LOBE VALVE SEAT NOTE 1 0 87W000621 870120 870224 LAPPED PLU6 AND SEAT COMPLETED RH FEV 0618 A B' BUTTERFLY VLV PACKING (1 DPM 86W008060 860918 ADJUSTED FACKING OPEN - FIELD WORK COMPLETE SI V 0062

- 3/4' GLOBE VALVE PACKING (1 DPM 0 86W004914 860714 860911 ADJUSTED PACKIN6 COMPLETED SI V 0073 8 3/4' GLOBE VALVE PACKING (I DPM 0 86W008723 861010 870115 ADJUSTED PACKIN6 COMPLETED St V 0076 8 3/4' I l' RELIEF SEAT NOTE 2 0 86W006157 860730 860910 REPLACED VALVE COMPLETED

$1 V 0093

- 2' 6 LOBE VALVE PACKING (1 DPM 0 86W008139 860923 861110 ADJUSTED PACKING COMPLETED St V 0098 A 3/4' GLOBE VALVE PACKING (1 DPM 0 86W008137 860923 861110 ADJUSTED PACKING COMPLE!ED St V 0099 A 3/4" GLOBE VALVE MECH JT 2 DFM 0 86W002977 860613 861208 REPLACED FLEI HOSE COMPLETED 3/4' I l' RELIEF SEAT NOTE 2 0 86W008296 860927 861211 REPLACED VALVE COMPLETED Si V 0175 St V 0200 8 3/4' GLOBE VALVE SEAT NOTE I B6WOOB136 860923 0 FEN St V 0248

- 3/4' I l' REllEF SEAT NOTE 2 0 86 WOO 7604 860909 861125 REPLACED VALVE INTERNALS COMPLETED SS V 0230

- t/4' 6 LOBE VALVE PACKING (1 DPM 87W002316 870309 0 FEN 1/2' 6LDBE VALVE SEAT NOTE 2 87W002109 870302 0 FEN SS FV 9606 SS FV 9611

- 1/2' 6 LOBE VALVE PACKING 80 DPM 87 WOO 2399 860311 OPEN TOTALS Printed 83 of the 83 records. _ _ - - _.

_.- Dicne.Currrn.fEsquira-Patsr-S. Mrthawa, Mayor H:rmon & W;ico:.

City Hall

-2001 S-Strast,.NW Newburypset, MA: 01950.

Suite 430

' Washington, DC.20009 Judith H. Mizner Silvergate, Gertner, Baker, Sherwin E. Turk, Esquire Fine, Good & Mizner Office of the Executive Legal _ Director 88 Broad Street-U.S. Nuclear Regulatory Commission Boston, MA 02110 Tenth Floor Washington, DC 20555 Calvin A. Canney City Manager Robert A. Backus, Esquire City Hall 116 Lowell Street 126 Daniel Street P.O. Box 516 Portsmouth, NH 03801 Manchester, NH 03105 Stephen E. Merrill, Esquire

' Philip Ahrens, Esquire Attorney General Assistant Attorney General George Dana Bisbee, Esquire Office of The Attorney General Assistant Attorney General.

State House Station #6 Office of the Attorney General-Augusta, ME 04333 25 Capitol Street Concord, NH 03301-6397 i

Mrs. Sandra Gavutis, Chairman Board of Selectmen Mr. J. P. Nadeau RFD 1, Box 1154 Selectmen's Office Kensington, NH 03827 10 Central Road Rye, NH 03870 Carol S. Sneider, Esquire Assistant Attorney General Mr. Angie Machiros, Chairman Office of the Attorney General Board of Selectmen

+

One Ashburton Place, 19th Floor Town of Newbury Boston, MA 02108 Newbury, MA 01950 Senator Gordon J. Humphrey Mr. William S. Lord United States Senate Board of Selectmen Washington, DC 20510 Town Hall - Friend Street i

Attention: Tom Burack Amesbury, MA 01913 Richard A. Hampe, Esquire Senator Gordoa J. Humphrey Hampe and McNicholas 1 Eagle Square, Suite 507 35 Pleasant Street Concord, NH 03301 Concord, NH 03301 Attention: Herb Boynton i

Thomas F. Powers, III H. Joseph Flynn, Esquire Town Manager Office of General Counsel Town of Exeter Federal Emergency Management Agency 10 Front Street 500 C Street, SW Exeter, NH 03833 Washington, DC 20472 Brentwood Board of Selectmen Paul McEachern, Esquire RFD Dalton Road Matthew T. Brock, Esquire Brentwood, NH '03833 Shaines & McEachern 25 Maplewood Avenue Gary W. Holmes, Esquire P.O. Box 360 Holmes & Ells Portsmouth, NH 03801 47 Winnacunnet Road i

Hampton, NH 03842 Robert Carrigg Town Office Mr. Edward A. Thomas Atlantic Avenue FEMA, Region I North Hampton, NH 03862 442 John W. McCormack Post l

Office and Courthouse

[

Boston, MA 02109

Administrative Judge Helen Hoyt, Chairperson Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Administrative Judge Sheldon J. Wolfe, Chairman Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Dr. Emmeth A. Luebke Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Dr. Jerry Harbour Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 Administrative Judge Custave A. Linenberger, Jr.

Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, DC 20555 4

$