Responds to NRC Re Violations Noted in Insp Rept 50-286/86-21.Corrective Actions:Operators Placed Switches in automatic,pre-warmup check-off List Performed & All Equipment Demonstrated to Be in Proper Condition
ML20207R969
Person / Time
Site: Indian Point 
Issue date: 03/10/1987
From: Brons J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
IPN-87-014, IPN-87-14, NUDOCS 8703180369
Download: ML20207R969 (5)


Text

-

f.

DC3 123 Main Street White F%ns, New Wrh 10601 914 681.6240

  1. > NewWrkPbwer C"i"T:seet

& Authority March 10, 1987

" ~**

IPN-87-014 U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C.

20555

Subject:

Indian Point 3 Nuclear Power Plant Docket No. 50-286 Inspection No. 50-286/86-21 and Notice of Violation dated January 20. 1987

Reference:

1.

Letter from Dr. Thomas E. Murley to Mr.

J.

C.

Brons dated February 18, 1987

Dear Sir:

This letter provides the Authority's response to Inspection Report Number 50-286/86-21 and the subsequent Notice of Violation, dated January 20, 1987.

The date for submitting this response was extended by Reference 1. to this letter addresses the points cited in the Notice of Violation.

Enclosed is a check in the amount of fifty thousand dollars ($50,000), for payment of the Civil Penalty imposed in connection with this violation.

Should you or your staff have any questions regarding this matter, please contact Mr.

P.

Kokolakis of my staff.

Very truly yours, x

John C.

Brons Senior Vice President f[k3I$DO O 86 PDR Nuclear Generation g

Attachment cc: Dr. Thomas E. Murley Regional Administrator U.S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Resident Inspector's Office Indian Point Unit 3 U.S. Nuclear Regulatory Commission (f

Buchanan, NY 10511

Mr. J. M.

Taylor, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. J. D. Neighbors, Sr. Proj. Mgr.

PWR Project Directorate No. 3 Division of PWR Licensing-A U.S. Nuclear Regulatory Commission 7920 Norfolk Avenue Bethesda, MD 20014 t

l

)

l L

In an effort to reduce the demands on the Control Room operators and utilize shift manpower more efficiently during plant startups, the R0-Rover assumed responsibility for performance of the Pre-Warmup check-off list. This inadvertently reduced the involvement and control of the Senior Reacter Operator in this crucial plant evolution.

Additionally, Plant Operating Procedures did not specifically address manipul-ation of the Containment Spray and Recirculation Pump control switches in a manner equivalent to other Engineered Safety Feature Pump switches although their importance with respect tothe Technical Specifications is the same.

With respect to this event, the RO-Rover was performing the Pre-warmup check-off list in preparation for plant startup. Based on interviews with the involved parties, the operator apparently requested the Control Room operators to place the Containment Spray and Recirculation pump switches in automatic.

The check-off list was completed for the pumps indicating their operability, however, the Control Room operators did not complete the requested manipul-ation of the control switches.

Corrective Actions - Immediate Immediately upon identification of the mispositioned switches, operators placed the switches in automatic. The Pre-Warmup check-off list was performed and all equipment was demonstrated to be in its proper / required condition.

Upper management at the plant was promptly apprised of the event and initiated an investigation. All shift crews were briefed on the incident prior to assuming their next watch stand.

Corrective Actions - Follow-Up The follow-up corrective actions have addressed the administrative controls which govern the activities determined to be deficient in this event. Specif-ically, proceiures which deal with plant operation during transient conditions (startup and shutdown) and shift relief and turnover were reviewed and revised to enhance the management controls and oversight on shift operation.

The plant heatup check-off list has been revised and now includes separate lists for pre-200*F and pre-350',F plant conditions.

By treating these con-ditions separately, the operators cognizance of the equipment that must be operable during any partic61ar t'ransient condition or mode is enhanced.

The check-off lists for startup have also been revised to coordinate and reaffirm control by the Senior Reactor Operator and Shift Supervisor. This is accomplished by mandating that the particular check-off list be initiated, performed and completed by a Senior Reactor Operator.

Furthermore, the Shift Supervisor is now required to review each major section of the completed check-off list.

Both the Shift Supervisor and Senior Reactor Operator must complete the check-off list prior to the mode change. These changes improve the administrative controls in place during transient operations and address the contributing causes noted by the Inspector.

Page 2

The Plant Operating Procedures (POP) for startup and shutdown also have been reviewed and revised. The procedures have been revised to address the Con-tainment Spray and Recirculation pumps in a manner equivalent to the Safety injection pumps. The startup POP now specifically addresses the operability requirements of the Containment Spray and Recirculation pumps during cold shutdown and hot shutdown conditions and includes a requirement for the operator to sign off that the pumps are operable. The instructions addressing the high head safety injection pumps also have been clarified. These changes add another level of administrative control on plant operations during tran-sient conditions. Associated procedures for control of the cooldown process have been similarly revised.

The Authority has taken steps to improve the Control Room environment and reduce the demands on the operators attention. Measures have been implemented to better control access to the control room operators. The hierarchy within the Control Room is firmly established and the activities peripheral to operations such as surveillance testing, research activities and casual interactions have been limited.

The foregoing revisions to administrative controls and operating practices are believed to be comprehensive and are intended to establish an environment that will prevent a similar occurrence in the future.

In addition, the Authority has taken action to enhance controls on shift turnover procedures as described in the following paragraph. These steps are intended to provide assurance that if such an event occurred again it would be detected at the next watch relief.

The Authority has revised the Shift Relief and turnover procedure to specif-ically require the oncoming Senior Reactor Operator and Shift Supervisor to review individual Control Room panels and document the same on the Shift Relief and Turnover Checklist. Prior to being relieved of his shift, the Senior Reactor Operator will prepare a Shift Relief and Turnover checklist for review by the oncoming shif t Senior Reactor Operator and Shif t Supervisor.

These changes will enhance the administrative controls currently in place for shift turnover and further elevate the operator's attention to detail.

Summary All corrective actions described herein have been completed.

The Authority considers the actions to be comprehensive and appropriate to enhance the level of oversight of shift activities by shift management. The changes will promote an increased awareness to detail above that which is already prevalent. The changes to plant operating procedures and check-off lists provide multiple layers of administrative control which will ensure the equipment required by the Indian Point 3 Technical Specifications is operable at the appropriate time during plant transient operations.

Page 3

.o j

ATTACHMENT 1 Violation Technical Specification Limiting Conditions for Operation 3.3.A.1.d and 3.3.B.1.b respectively require that the reactor shall not be heated up above the cold shutdown condition (i.e., the reactor coolant system average tempera-ture shall not exceed 200*F) unless one of two recirculation pumps and both containment spray pumps together with r associated piping and valves are operable.

"t approximately 1:30 a.m. on September 2, 1986, the reactor was heated up above the cold shutdown condition (i.e., the reactor coolant system tempera-ture exceeded 200*F) and, at the time, both recirculation pumps and contain-ment spray pumps were inoperable, and remained inoperable until 7 a.m. on that same day, be virtue of the fact that the pump control switches in the control room were in the stop pullout position rather *han the auto position as required.

The condition represented a violation of the referenced Technical Specifica-tions.

Response

To the extent the containment spray pumps and recirculation pumps are con-sidered inoperable when their control switches are not in the automatic position, the Authority admits that Technical Specifications 3.3.A.1.d and 3.3.B.1.b were not adhered to for a period of approximately six hours during the plant heatup on September 2, 1986.

Plant safety was never compromittd during this event since both sets of pumps were functional as demonstrated by surveillance testing and capable of manual operation for the control room.

Indication was also available to the control room operators which would have prohibited continued heatup of the plant above 350*F with the control switches for the Containment Spray and Recirculation pumps in the non-automatic condition.

Reasons for Violation The violation of Technical Specifications during plant heatup can best be described as a reduction in administrative control on the part of the shift management as afforded by procedures. Several factors contributed to this reduction in control. The governing check-off list combined conditions necessary to exceed 200*F and other conditions necessary to exceed 350*F.

Also, the incorporation of an additional licensed operator on shift who is normally assigned duties outside the control room in response to item 1.A.1.3 of NUREG-0737 had some effect. This position, designated the Reactor Operator

- Rover (RO-Rover), was qualified to perform equipment manipulations and hence perform check-off lists. The R0-Rover, however, is not considered a control room position.