SER on 870120 Application for Amend to License SNM-1067, Excluding Storage of Fuel Bundles in Shipping Containers 927A & 927C.Issuance of Amend Recommended
ML20207R928
Person / Time
Site: 07001100
Issue date: 03/13/1987
From: Crow W, Ketzlach N
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20207R906 List:
References
NUDOCS 8703180313
Download: ML20207R928 (2)


Text

=

MAR 131987 FCUP:NK DOCKET NO:

70-1100 APPLICANT:

Combustion Engineering, Inc.

FACILITY:

Windsor, Connecticut

SUBJECT:

SAFETY EVALUATION REPORT - REVIEW 0F LICENSE APPLICATION DATED JANUARY 20, 1987 I.

Background

Combustion Engineering, Inc. (CE), by application dated January 20, 1987, requested authorization to exclude the storage of fuel bundles in shipping containers Nos. 927A and 927C in accordance with the Transport Index criteria. At the present time, all arrays of shipping containers containing special nuclear material are stored in accordance with Transport Index criteria.

II. Discussion A.

Nuclear Criticality Safety At the present time, the size of any array of shipping containers is limited to a total Transport Index of 80. CE requested that it be exempted from restricting the storage of 927A and 927C Fuel Bundle Shipping Containers in accordance with the Transport Index criteria.

Since CE did not specify the criteria to be used in establishing the nuclear criticality safety of arrays of fuel bundles, the staff contacted Mr. R. E. Sheeran, CE Manager, Nuclear Licensing Safety, Accountability, and Security on March 6, 1987, to confirm that the criteria ~in Part I of the license application (License Conditions Section 4.3.16) was to be applied. He confirmed storage of the containers in arrays up to three high. An infinite array of the containers with fuel assemblies having U-235 enrichments no greater than 4.1 percent U-235 is safe independent of the degree of water moderation and water reflectign.

In addition, Figure 4.2.1, "CM ticality Alarm System Buildings 17 and 21 (Detector Locations)" has been revised to include the detector head in Criticality Area 8 (?'ocated in the northwest corner of the yard area of the Building 17/21 complex).

B.

Radiation Safety Since there is no change requested in the facility operations or in the radiation safety controls, there will be no change in the radiological safety of the operations.

8703180313 870313 PDR ADOCK 07001100 cc PDR l

Combustion Engineering, Inc. SERz 2

MAR 131987 j

C.

Environmental Protection W

There is no requested change in the environmental protection requirements for the facility. The requested change in the criteria applied to the storage of' fuel assemblies in their

~ hipping containers does not result in (1) any significant s

change in the types or significant increase in the amount of effluents that may be released offsite, (2) any significant increase in individual or cumulative occupational radiation exposure, (3) any significant construction impact, and (4) any significant increase in the potential for or consequences from radiological accidents. 'Therefore, in accordance with 10 CFR 51.22(c)(11), neither an Environmental Assessment nor an Environmental Impact Statement is necessary for l

the proposed action.

D.

General The amendment application dated January 20, 1987, was discussed with Mr. Jerome Roth, Region I Facility Inspector, on March 6,1987. He foresaw no safety or environmental problem with the requested authorization.

III. Conclusion Issuance of the amendment authorizing the storage of fuel bundles in Shipping Containers 927A and 927C in accordance with Section 4.3.16 of the License Conditions Section of the license is recommended.

e a n nsaca'r;

' M '.ach Norman Ketzlach Uranium Process Licensing Section Uranium Fuel Licensing Branch Division of Fuel Cycle and Material Safety, NMSS Oricinal signg3 gg, W 7. cr~,,

Approved by:

W. T. Crow, Section Leader i

0FC:FCUP

FCUF /
FCUF

______,._Y

VLk@arp_e________:WTCrodhh 9

NAME:NKet lach:ht h

DATE:03/of/87

03/%/87
03/,v/87 :

0FFICIAL MECORD COPY

.