h { (p O

Docket No. 50-313 January 9,1987 Mr. Gene Campbell Vice President, Nuclear Operations Arkansas Power and Light Company P.O. Box 551 Little Rock, Arkansas 72203

Dear Mr. Campbell:

We are continuing our review of your letter of October 17, 1986, concerning the compliance of the reactor coolant system leak detection systems of Arkansas Nuclear One, Unit 1, with the guidelines of Regulatory Guide 1.45 for the purpose of exemption from the pipe break criteria of GDC 4 on the basis of leak-before-break. We have determined the need for additional information which is identified in the enclosed Request for Additional Information. We request your response within 45 days from receipt of this letter.

The information requested by this letter affects fewer than 10 respondents; therefore, OMB clearance is not required under P.L.96-511.

Sincerely,

/S/

John F. Stolz, Director PWR Project Directorate #6 Division of PWR Licensing-B

Enclosure:

As stated cc w/ enclosure:

See next page DISTRIBUTION GEdison BGrimes Docket File NRC & LPDRs Ringram FMiraglia GVissing OGC-MNBB 9604 EJordan ACRS-10 JPartlow 8701280459 870109 DR ADOCK 0500 3

NThompson p

PBD#6 files PBD-6 PBD-

/ / 7/87.

GEdi n

JFS.

GVis j/g/87 l / /87

\\-

Mr. G.. Campbell Arkansas Power & Light Company Arkansas Nuclear One, Unit I cc:

Mr. J. Ted Enos, Panager Nuclear Engineering and Licensing Arkansas Power & Light Company

{

P. O. Box 551 Little Rock, Arkansas 72203 Mr. James M. Levine, Director Site Nuclear Operations Arkansas Nuclear One

(

P. O. Box 608

[

Russellville, Arkansas 72801 Mr. Nicholas S. Reynolds Bishop, Liberman, Cook, Purcell & Reynolds 1200 Seventeenth Street, N.W.

Washington, D.C.

20036

(

Mr. Robert B. Borsum Babcock &.Wilcox Nuclear Power Generation Division Suite 220, 7910 Woodmont Avenue Bethesda, Maryland 20814 Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box 2090 Russellville, Arkansas 72801 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Mr. Frank Wilson, Director Division of Environmental Health Protection Department of Health Arkansas Department of Health 4815 West Markham Street Little Rock, Arkansas 72201 Honorable William Abernathy County Judge of; Pope County Pope County Courthouse Russellville, Arkansas 72801 4

1

REQUEST FOR ADDITIONAL INFORMATION CONCERNING COMPLIANCE OF RCS LEAK DETECTION SYSTEMS WITH THE GUIDELINES OF REGULATORY GUIDE 1.45 FOR EXEMPTION FROP GDC BASED ON LEAK-BEFORE-BREAK AT ARKANSAS NUCLEAR ONE, UNIT 1 DOCKET NO. 50-313 1.

Indicate the sensitivity of the airborne particulate and gaseous radiation monitors used for detection of unidentified RCS leakage.

Confirm that their sensitivity satisfies the guidelines of Regulatory Guide 1.45.

2.

Describe how you will use the inventory balance procedure in converting the indication by the other two methods (i.e., sump level and radiation monitoring) to a common leakage equivalent.

3.

Identify and briefly summarize the procedure for testing operability and calibration of the RCS leak detection systems.

Include references to the specific sections of the plant's Technical Specifications as applicable.

__