ML20207Q216

From kanterella
Jump to navigation Jump to search
Discusses Re Charcoal to Be Utilized in Safety & nonsafety-grade Air Filtration Units.Although Max Value of 1.5% Above 861021 Commitment of 1%,absorber Matl Acceptable. SER Encl
ML20207Q216
Person / Time
Site: Braidwood  
Issue date: 01/16/1987
From: Varga S
Office of Nuclear Reactor Regulation
To: Farrar D
COMMONWEALTH EDISON CO.
Shared Package
ML20207Q217 List:
References
NUDOCS 8701270023
Download: ML20207Q216 (3)


Text

f January 16, 1987 DISTRL L N, Docket Nos. STN 50-456 W

I B. Grimes and STN 50-457 NRC PDR N. Thompson Local PDR J. Partlow T. Novak C. Vogan PDf3 Rdg.

J. Stevens Mr. Dr.nnis L. Farrar E. Jordan ACRS(10)

Director of Nuclear Licensing OGC Comonwealth Edison Company Post Office Box 767 Chicago, Illinois 60690

Dear Mr. Farrar:

SUB.1ECT: CONTROL ROOM HABITARILITY - UTILIZATION OF CHARC0AL ADSORBER MATERIAL By letter dated November 17, 1986, you indicated that laboratory analysis of the charcoal to be utilized in the safety and non-safety grade air filtration units demonstrated an average penetration of 1.5%. This value is higher than the maximum value of 1% which you had committed to by letter dated October 21, 1986. The staff has evaluated this adsorber material and has found it acceptable.

In the same November 17, 1986 letter, you indicated that the carbon provided to fill the last six carbon trays and twenty test canisters is not identical to the type of carbon in the other trays. This charcoal, which is impregnated with TEDA and Kl. is approved by the staff for use at Braidwood Station provided that it is not mixed with the charcoal impregnated with KI alone and provided that the test canisters utilize TEDA and K! impregnated charcoal if the cells utilize TEDA and K! impregnated charcoal.

The staff's evaluation is enclosed.

If any further clarification is needed, please contact the Braidwood Project Manager, Ms. J. A. Stevens, at (301) 492-7829.

Sincerely,

/

,/S bf 50 56 P

PDR Steven A. Varga, Director Project Directorate #3 Division of PWR Licensing-A

Enclosure:

As stated cc: See next page

  • SEE PREV!0US CONCURRENCE PD#3 PD#3 C-CVogan*

15tevenstmak*

qa 1/16/07 1/16/87

/87

}

q 3

DISTRIRllTION Docket Nos. STN 50-456 Docket FHe R. Grimes and STN 50-457 NRC POR N. Thompson local PDR J. Partlow T. Novak C. Vogan PD#3 Rdg.

J. Stevens l

Mr. Dennis L. Farrar E. Jordan ACRS(ID)

Director of Nuclear Licensing 000 Cosmonwealth Edison Company Post Office Box 767 i

Chicago, Illinois 60690

Dear Mr. Farrar:

SUBJECT:

CONTROL ROOM HABITABILITY - UTILIZAT!DN OF CHARC0AL ADSORPER MATERIAL l

Ry letter dated November 17, 1986, you indicated that laboratory anal" sis of the charcoal to be utilized in the safety and non-safety grade air filtration units demonstrated an averace penetration of 1.5%.

This value is nigher than the maximum value of 1% which you had committed to by letter dated October ?1, i

1986. The staff has evaluated this adsorber material and has found it acceptable.

In the same Novemberl7,1986 letter, you indicated that the carbon provided to fill the last six carbon trays and twenty test canisters is not identical to the type of carbon in the other trays. This charcoal, which is impregnated i

I with TEDA and KI, is approved by the staff for use at Mraidwood Station provided that it is not mixed with the K! impreonated charcoal and prnvided l

that the test canisters utilize TEDA and KI impregnated charcoal if the cells utilize TEDA and K! impregnated charcoal.

The staff's evaluation is enclosed.

Tf any further clarification is needed, please contact the Braidwood Pro.fect Manager, Ms. J. A. Stevens, at (301) 497-7820

$1ncerely, 1

Steven A. Varga, Director Proiect Directorate #3 Division of PWR Licensing A I

cc: See next pace

Enclosure:

As stated PDf3)

PD#3 /

PD#3

.\\6 tvd 4an JStet nstmak SVarna

\\ 1//6/87 1///,/h7 1/ /87

4 I

Mr. Dennis L. Farrar Braidwood Station Comonwealth Edison Company Units 1 and 2 cc:

Mr. William kortier Ms. Lorraine Creek Atomic Power Distribution Route 1, Box 182 Westinghouse Electric Corporation Manteno, Illinois 60950 Post Office Box 355 Pittsburgh, Pennsylvania 15230 Douglass Cassel, Esq.

109 N. Dearborn Street Joseph Gallo, Esq.

Chicago, Illinois 60C02 Isham, Lincoln & Beale 1150 Connecticut Ave., N. W.

Elena Z. Kezelis, Esq.

Suite 1100 Isham, Lincoln & Beale Washington, D. C. 20036 Three First National Plaza Suite 5200 C. Allen Bock, Esq.

Chicago, Illinois 60602 Post Offices Box 342 Urbana, Illinois 61801 Mr. Charles D. Jones, Director Illinois Emergency Services Thomas J. Gordon, Esq.

and Disaster Agency Waaler, Evans A Gordon 110 East Adams Street 2503 S. Neil Springfield, Illinois 62706 Champaign, Illinois 61820 George L. Edgar Ms. Bridoet Little Rorem Newman A Holtzinger, P.C.

Appleseed Coordinator 1615 L Street, N.W.

117 North Linden Street Washinoton, D.C.

20036 Essex. Illinois 60935 Michael Miller Esq.

Mr. Edward R. Crass Isham, Lincoln A Beale Nuclear Satequards and One First National Plaza Licansino Division 42nd floor Saroent A Lundy Engineers Chicago, Illinois 60603 55 East Monroe Street Chicago, Illinois 60603 U. S. Nuclear Regulatory Comission Resident Inspectors Office RR81, Box 79 Braceville, Illinois 60407 Peqional Administrator, Region !!!

U. S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 l