j E R AMATOME COG EM A F U ELS February 11.1999 Director, Radiation Safety & Safeguards Region 11 United States Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth Street SW Suite 23T85 Atlanta, GA 30303
Reference:
SNM-1168, Docket 70-1201 Gentlemen:
In accordance with the provisions of 10CFR70.59, Framatome Cogema Fuels submits the enclosed Gaseous Efiluent Report for the second semi-annual period of 1998 for the Lynchburg Manufacturing Facility site located in Lynchburg, Virginia.
You may contact me at (804)832-2816 should you have any questions or require additional information concerning the enclosed report.
Sincerely, e
Timothy V. Allsep Manager, Radiation Protection Enclosure cc:
Ms. Elizabeth Q. Ten Eyck, Director Division of Fuel Cycle Safety & Safeguards Office of Nuclear Material Safety & Safeguards f
United States Nuclear Regulatory Commission Washington, D.C. 20555 Leslie P. Foldesi Commonwealth of Virginia (Jh' Department ofitealth P.O. Box 2448 1G0078 Richmond, VA 23218 9903170178 981231 PDR ADOCK 07001201 C
PDR 7FRAMATOME mme Frematome Cogema Fuels P O. Box 11646. Lynchburg, VA 24506-1646 TECHHOLOG1E5 Telephone: 804 832-5000 Fax: 804 832 5167
c 2/9/99 Pegg1 of 2 Gaseous Effluent Report
l Reporting Period:
07/01/98 to 012/31/98 Sample Collection Point:
Main Plant Stack Volume Released:
3.09E+09 cubic feet Stack Flow Rate (typical):
12000 cubic feet per minute Activity Released Gross Alpha:
2.350 uCi Gross Beta:
7.531 uCi isotope Activity Concentration
% DAC (uCl)
(uCi/ml)
U-234 1.83E+00 2.09E-14 41.74 U-235 1.02E-01 1.16E-15 1.94 U-236 8.25E-04 9.41E-18 0.02 U-238 4.25E-01 4.85E-15 8.08 j
Co-60 7.531228 8.59E-14 0.17
- 2. SERF-2 RCA I
Reporting Period:
07/01/98 to 012/31/98 Sample Collection Point:
SERF-2 RCA Stack Volume Released:
2.49E+08 cubic feet Stack Flow Rate (typical):
1031 cubic feet per minute Activity Released Gross Alph 0.000 uCl 1
Gross Beg 0.959 uCl isotope Activity Concentration
% DAC (uCl)
(uCi/ml)
Co-60 0.959 1.36E-13 0.27
- 3. SERF-3 RCA Reporting Period:
07/01/98 to 012/31/98 Sample Collection Point-SERF-3 RCA Stack J
Volume Released:
7.07E+08 cubic feet Stack Flow Rate (typical):
3292 cubic feet per minute Activity Released Gross Alpha:
0.000 uCl Gross Beta:
4.476 uCl Isotope Activity Concentration
% DAC (uCl)
(uCi/mi)
Co-60 4.476 2.24E-13 0 d5
[? ;
4'
.?
2/9/99 Peg 2 2 of 2
- 4. SERF-4 RCA Reporting Period:
07/01/98 to 012/31/98 Sample Collection Point:
SERF-4 RCA Stack Volume Released:
2.60E+09 cubic feet Stack Flow Rate (typical):
10000 cubic feet per minute Activity Released Gross Alpha:
0.000 uCi Gross Beta:
13.638 uCl isotope Activity Concentration
% DAC (uCl)
(uCl/ml)
Co-60 13.638 1.85E 13 0.37 L_.