Proposed Tech Specs,Revising Original Submittal w/870219 Application for Amend to License NPF-42 Re Mod of Existing License Conditions Re Fire Protection
ML20206R368
Person / Time
Site: Wolf Creek 
Issue date: 04/17/1987
From:
WOLF CREEK NUCLEAR OPERATING CORP.
To:
Shared Package
ML20206Q612 List:
References
NUDOCS 8704220154
Download: ML20206R368 (2)


Text

_ _ _ -. _ _ _ _ -

S 4

Attachment to ET 87-0155 Page 1 of 2 April 17,1987 j

v.

ADMINISTRATIVE CONTROLS

{

RESPONSIBILITIES (Continued) k.

Review of changes to the PROCESS CONTROL' PROGRAM, the OFFSITE DOSE CALCULATION MANUAL and the Radwaste Treatment Systems, anti 1.

Review of any accidental, unplanned, or uncontrolled radioactive release including the preparation of reports covering evaluation, recommendations, and disposition of the corrective action to prevent INSERT A recurrence and the forwarding of these reports to the Plant Manager and to the' Nuclear Safety Review Committee, and f

6.5.1.7 dePSRCsha15:~

m.

h m.

~

~

~~~

"' ~

'~

~

t a.

Recommend in writing to the Plant Manager approval or disapproval p

of itses considered under Specification 6.5.1.6a. through b.

Render determinations in writing with regard to whether or not each Q

ites considered under Specification 6.5.1.6a. through e. above p

constitutes an unreviewed safety question, and i

c.,

Provide written notification within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the Director'. Nuclear l

Operations and the Nuclear Safety Review Committee of disagreement r

between the PSRC and the Plant Manager; however, the Plant Manager

'l shall have responsibility for resolution of such disagreements pursuant to Specification 6.1.1 above.

RECORDS 6.5.1.8 The PSRC shall maintain written minutes of each PSRC seeting that, at a minimum, document the results of all PSRC activities perfonned under the responsibility provisions of these Technical Specifications. Copies shall be provided to the Director Nuclear Operations and the Nuclear Safety Review Committee.

6.5.2 NUCLEAR SAFETY REVIEW COMMITTEE (NSRC')

FUNCTION 6~. 5. 2.1 The NSRC shall function to provide independent review and audit of designated activities in the areas of:

a.

Nuclear' power plant operations, b.

Nuclear engineering, c.

Chemistry and radiochemistry, d.

Metallurgy, s

e.

Instrumentation and c.ontrol, f.

Radiological safety, wu e encer -. ' - -

69 8704220154 870417 PDR ADOCK 05000482 P

_PDR _ _ _ _ _ __ _

4 Attachment to ET 87-0155 Page 2'or 2 April 17,1987 Insert A m.

Review of the Fire Protection Program and Implementing Procedures and shall submit recommended changes to the Nuclear Safety Review Committee.

Discussion of Change This change adds an additional programatic review requirement to the Technical Specifications.

This change will assure that the review of fire protection program requirements is equivalent to the review requirements of comparable programs.

Therefore, the conclusions of the complete Safety Evaluation and Significant Hazards Consideration transmitted by letter dated February 19, 1987 (ULRNC-1447) as endorsed by letter dated March 2, 1987 (WM-87-0068) remain valid.