um-TABLE 3.3-4 (Continued)

ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION TRIP SETPOINTS m

m o

FUNCTIONAL UNIT TRIP SETPOINT ALLOWABLE VALUES C5 4.

Steam Line Isolation 5

da a.

Manual Initiation N.A.

N.A.

e.

m b.

Automatic Actuation Logic H.A.

N.A.

and Actuation Relays c.

Containment Pressure--High-High 5 2.9 psig i 3.0 psig d.

Negative Steam Line 1 -100 psi /sec 1 -120 psi /sec Pressure Rate - High e.

Steam Line Pressure - Low

> 585 psig

> 565 psig 5.

Turbine Trip and Feedwater Isolation a.

Automatic Actuation Logic N.A.

N.A.

and Actuation Relays b.

Steam Generator Water level--

< 82% of narrow range

< 83% of narrow range High-High (P-14)

Instrument span each steam Instrument span each steam generator generator

,N a$$

c.

Doghouse Water Level-High 12" 13" g{

(Feedwater Isolation Only) oo

((

6.

Containment Pressure Control System oo Start Permissive / Termination 0.3 i SP/T 1 0.4 PSIG 0.25 i SP/T 1 0.45 PSIG (SP/T) um EE a=

8606240151 860616 mw PDR ADOCK 05000369 P

PDR vv

v i

TABLE 4.3-2 (Continued)

I Ng ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION g

SURVEILLANCE REQUIREMENTS m

e TRIP c-ANALOG ACTUATING MODES 3

CHANNEL DEVICE MASTER SLAVE FOR WHICH CHANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION RELAY RELAY SURVEILLANCE s

FUNCTIONAL UNIT CHECK CALIBRATION TEST TEST LOGIC TEST TEST TEST IS REQUIRED

[

4. Steam Line Isolation a.

Manual Initiation N.A.

N.A.

N.A.

R N.A.

N.A.

N.A.

1,2,3 b.

Automatic Actuation N.A.

N.A.

N.A.

N.A.

M(1)

M(1)

Q 1,2,3 Logic and Actuation Relays c.

Containment Pressure-- S R

M N.A.

N.A.

N.A.

N.A.

1,2,3 High-High y

d.

Negative Steam Line S

R M

N.A.

N.A.

N.A.

N.A.

3 Pressure Rate-High

[

e.

Steam Line 5

R M

N.A.

N.A.

N.A.

N.A.

1,2,3 m

Pressure--Low

5. Turbine Trip and Feedwater Isolation a.

Automatic Actuation N.A.

N.A.

N.A.

N.A.

M(1)

M(1)

Q 1, 2 Logic and Actuation

((

Relay

$h b.

Steam Generator Water S R

M N.A.

N.A.

N.A.

N.A.

1, 2 ge Level-High-High (P-14) c.

Doghouse Water S

N.A N.A R

N.A.

N.A.

N.A.

1, 2 IE Level-High 1

(Feedwater Isolation 22 Only)

((

6. Containment Pressure Control System Start Permissive /

S R

M N.A.

N.A.

N.A.

N.A.

1, 2, 3, 4 Termination vv

- - _ _ _ _ _ _ - _ - _ - - _ _