Monthly Operating Rept for Mar 1986
ML20206D970
Person / Time
Site: Millstone 
Issue date: 03/31/1986
From: Elms A, Romberg W
NORTHEAST NUCLEAR ENERGY CO., NORTHEAST UTILITIES
To:
NRC OFFICE OF RESOURCE MANAGEMENT (ORM)
References
MP-8911, NUDOCS 8606230022
Download: ML20206D970 (4)


Text

-

l AVERAGE DAILY UNIT POE R LEVEL DOCKET NO. 50-423 l

UNIT Millstone Unit No. 3 DATE 4/4/86 COMPLETED BY A. Elms TELEPHONE (203) 444-5388 MONTH March l

DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1 0

17 507 2

0 18 508 3

0 19 347 4

0 20 0

5 0

21 217 6

210 22 506 7

271 23 500 8

283 24 512 9

282 25 538 10 286 26 789 11 285 27 838 12 289 28 839 13 288 29 834 14 324 30 712 15 409 31 189 16 436 l

St2'*lB8E! I%JS SE 89 l

/g

OPERATING DATA REPORT DOCKET NO. 50-423 DATE 4/4/86 COMPLETED BY A. Elms TELEPHONE (203) 444-5388 OPERATING STATUS 1.

Unit Name: Millstone Unit 3 NOTES 2.

Reporting Period: March 1986 3.

Licensed Thermal Power (MWt): 3411 4.

NameplateRating(GrossMWe): 1253 5.

Design Electrical Rating (Net MWe): 1156 6.

Maximum Dependable Capacity (Gross MWe): 0 7.

Maximum Dependable Capacity (Net MWe): 0 8.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: N/A _ _ _ _ _ _

9.

Power Level To Which Restricted, If Any (Net MWe): N/A 10.

Reasons For Restrictions, If Any: N/A _

This Month Yr To Date Cumulative 11.

Hours In Reporting Period 744.0 1143.6 1143.6 12.

Number of Hours Reactor Was Critical 614.2,

788.3 788.3 13.

Reactor Reserve Shutdown Hours 0.0 0.0 0.0 14.

Hours Generator On Line 575.4 718.9 718.9 15.

Unit Reserve Shutdown Hours 0.0 0.0 0.0 _

16.

Gross Thermal Energy Generated (MWH) 920219.3 1099878.5 1099878.5 17.

GrossElectricalEnergyGenerated(MWH) 294304.5 334730.2 334730.2 18.

NetElectricalEnergyGenerated(MWH) 262447.7 290918.4 290918.4 19.

Unit Service Factor N/A N/A N/A 20.

Unit Availability Factor N/A N/A N/A 21.

Unit Capacity Factor (Using MDC Net)

N/A N/A N/A 22.

UnitCapacityFactor(UsingDERNet)

N/A N/A N/A 23.

Unit Forced Outage Rate N/A N/A N/A 24.

Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

April 14 - Reactor Trip from 100% durinq testinq

~

25.

If Shut Down at End of Report Period, Estimated Date of Startup: April 8 26.

Units in Test Status (Prior to Commercial Operation): Forecast Achieved Commercial Operation 5/1/86

UNIT SHUTDOWNS AND POE R REDUCTIONS DOCKET NO. 50-423 UNIT Millstone Unit No.

3-DATE 4/4/86 COMPLETED BY A. Elms

~

TELEPHONE (203) 444-5388 REPORT MONTH March Method of Licensee Cause & Corrective Duration Shutting Event System Component Action to No.

Date Type (1)

(Hours)

Reason (2)

Down Reactor (3) Report #

Code Code Prevent Recurrence 86-05 3/1/86 F

124.1 B

4 N/A SJ SG Continued outage from previous month 86-06 3/19/86 F 31.2 B

9 N/A FK XFMR Turbine Trip to clean main & normal trans-formers due to weather 86-07 3/31/86 S 13.3 B

1 N/A SB SHV Power ascension test i

t s

1 2

3 4

F: Forced Reason:

Method:

Exhibit G - Instructions S: Scheduled A - Equipment Failure (Explain) 1 - Manual for Preparation of Data B - Maintenance or Test 2 - Manual Scram Entry Sheets for C - Refueling 3 - Automatic Scram Licensed Event Report D - Regulatory Restriction 4 - Continued from (LER) File (NUREG-0161)

E - Operator Training & License previous month Examination 5 - Power Reduction 5 F - Administrative (Duration = 0)

Exhibit 1 - Same Source G - Operational Error (Explain) 9 - Other (Explain)

H - Other (Explain)

.I r

General Offices

  • Selden Street. Berlin. Connecticut w ccwctcvi m o wa cw-P.O. BOX 270 l

.tvm. -ns sacmc cw-HARTFORD, CONNECTICUT 06141-0270

.<x os. cia m-e= w='

(203) 666-6911 J

% ' % "1. U. 2,'c C ~=,

k April 8, 1986 MP-8911 Director, Office of Resource Management U. S. Nuclear Regulatory Commission Washington, D. C. 20555

Reference:

Facility Operating License No. NPF-49 Docket No. 50-423

Dear Sir:

In accordance with reporting requirements of Technical Specifications Section 6.9.1.5, the Millstone Nuclear Power Station - Unit 3 Monthly Operating Report 86-4, covering operations for the period March 1,1986 to March 31, 1986, is hereby forwarded.

Yours truly, NORTHEAST NUCLEAR ENERGY COMPANY

/,<) 0 '

Wayne D.

erg Station Superintendent Millstone Nuclear Power Station WDR/DM:se Attachment Regional Administrator, Office of Inspection and Enforcement, Region I cc:

Director, Office of Inspection and Enforcement, Washington, D.C. (10)

U. S. Nuclear Regulatory Commission, c/o Document Management Branch, Washington, D. C. 20555 W>d\\