Text

_ _ _

I SUPPLEMENTAL MATERIAL FOR 1980 SEMI-ANNUAL REPORTS 8606190720 860028 f

PDR ADOCK 05000285 R

PDR

m,_.....

_____._._.m._

TOBLE 1A EFFLUENT'OND WQSTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 80 1 QUARTER 2 QUARTER NUCLIDES IN CURIES CONT DECAY RM060 TOTAL CONT DECAY RM060 TOTAL Q.

FISSION & ACTIVATION GASES TOTAL RELEASE C1 1.26E+02 2.53E+01 0.00E+00 1.51E+02 9.42E-01 2.03E-01 0.00E+00 1.15E+00 CVG RELEASE RATE FOR PERIOD UCI/SEC 1.60E+01 3.22L+00 0.00E+00 1.92E+01 1.20E-01 2.58E-02 0.00E+00 1.46E-01 PERCENT OF LIMIT TECH SPEC = NONE B.

10 DINES TOTAL RELEASE IODINE - 131 CI 0.00E+00 0.00E+00 1.94E-03 1.94E-03 0.00E+00 0.00E+00 1.26E-05 1.26E-05 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 2.47E-04 2.47E-04 0.00E+00 0.00E+00 1.60E 1.60E-06 PERCENT OF LIMIT

-TECH SPEC = NONE C.

PARTICULATES PARTICULATES WITH HALF LIVES.GT. 8 DAYS CI 0.00E+00 0.00E+00 4.02E-05 4.02E-05 0.00E+00 0.00E+00 6.06E-05 6.06E-05 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 5.11E-06 5.11E-06 0.00E+00 0.00E+00 7.71E-06 7.71E-06 PERCENT OF LIMIT TECH SPEC = NONE GROSS ALPHA RADIOACTIVITY CI O.00E+00 0.00E+00 4.23E-07 4.23E-07 0.00E+00 0.00E+00 2.80E-06 2.80E-06 D.

TRITIUM l

TOTAL RELEASE l

CI 2.77E-01 7.83E-02 0.00E+00 3.55E-01 3.18E-02 1.40E-02 0.00E+00 4.59E-02 AVG RELEASE RATE

. 9,96E-03 0.00E+00 4.52E-02 4.05E-03 1.78E-03 0.00E+00 5.83E-03 FOR PERIOD UCI/SEC 3.53E-02 PERCENT OF LIMIT TECH SPEC = NONE I

..mm

_,4

_.4 TABLE IC l

EFFLUENT GMD WGSTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 80 1 QUARTER 2 QUARTER NUCLIOES IN CURIES CONT DECAV RMO60 TOTAL CONT OECAY RM060 TOTAL FISSION GASES XENON-133 1.22E+02 2.46E+01 0.00E+00 1.47E+02 7.12E-01 1.96E-05 0.00E+00 7.12E-01 KRYPTON-85M 1.74E-02 1.14E-03 0.00E+00 1.86E-02 7.98E-04 6.70E-06 0.00E+00 8.04E-04 XENON-131M 0.00E+00 1.46E-02 0.00E+00 1.46E-02 5.25E-03 7.62E-04 0.00E+00 6.01E-03 KRYPTON-88 1.71E-02 2.29E-03 0.00E+00 1.93E-02 6.32E-04 1.54E-05 0.00E+00 6.47E-04 XENON-133M 8.29E-01 8.14E-02 0.00E+00 9.10E-01 2.13E-02 3.51E-05 0.00E+00 2.14E-02 XENON-135 4.70E-01 1.40E-02 0.00E+00 4.84E-01 3.32E-02 5.44E-06 0.00E+00 3.32E-02

(

KRYPTON-87 2.05E-02 8.05E-03 0.00E+C0 2.85E-02 1.34E-03 1.04E-05 0.00E+00 1.35E-03 XENON-138 6.23E-02 9.50E-03 0.00E+00 7.18E-02 4.36E-04 4.10E-05 0.00E+00 4.77E-04 KRYPTON-85 1.88E+00 6.28E-01 0.00E+00 2.50E+00 7.35E-02 2.02E-01 0.00E+00 2.76E-01 XENON-135M 1.64E-02 2.67E-03 0.00E+00 1.91E-02 1.69E-03 6.51E-06 0.00E+00 1.70E-03 ARGON-41 2.98E-01 1.17E-03 0.00E+00 2.99E-01 9.23E-02 4.29E-06 0.00E+00 9.23E-02 TOTAL FOR PERIOD 1.26E+02 2.53E+01 0.00E+00 1.51E+02 9.42E-01 2.03E-01 0.00E+00 1.15E+00 IODINES 100!NE-131 CTD.

0.00E+00 0.00E+00 1.94E-03 1.94E-03 0.00E+00 0.00E+00 1.26E-05 1.26E-05 10 DINE-133 CTD.

0.00E+00 0.00E+00 5.69E-06 5.69E-06 0.00E+00 0.00E+00 3.24E-05 3.24E-05 IODINE-135 CTD.

0.00E+00 0.00E+00 1.61E-05 1.61E-05 0.00E+00 0.00E+00 1.26E-05 1.26E-05 TOTAL FOR PERIOD O.00E+00 0.00E+00 1.96E-03 1.96E-03 0.00E+00 0.00E+00 5.76E-05 5.76E-05 PARTICULATES STRONTIUM-89 0.00E+00 0.00E+00 3.62E-17 3.62E-17 0.00E+00 0.00E+00 1.52E-17 1.52E-17 STRONTIUM-90 0.00E+00 0.00E+00 4.37E-17 4.37E-17 0.00E+00 0.00E+00 1.52E-17 1.52E-17 100!NE-131 PRF.

0.00E+00 0.00E+00 7.51E-07 7.51E-07 0.00E+00 0.00E+00 1.99E-06 1.99E-06 d

IODINE-133 PRF.

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BARIUM-140 0.00E+00 0.00E+00 1.31E-05 1.31E-05 0.00E+00 0.00E+00 8.95E-06 8.95E-06 CESIUM-137 0.00E+00 0.00E+00 7.96E-06 7.96E-06 0.00E+00 0.00E+00 2.13E-05 2.13E-05 CESIUM-134 0.00E+00 0.00E+00 5.92E-06 5.92E-06 0.00E+00 0.00E+00 1.19E-05 1.19E-05 i

C08 ALT-58 0.00E+00 0.00E+00 8.56E-06 8.56E-06 0.00E+00 0.00E+00 7.46E-06 7.46E-06 MANGANESE-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 1.38E-06 1.38E-06 COBALT-60 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 4.71E-06 4.71E-06 IODINE-135 PRF.

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LANTHANUM-140 0.00E+00 0.00E+00 3.96E-06 3.96E-06 0.00E+00 0.00E+00 2.96E-06 2.96E-06 tTOTAL FOR PERIOD 0.00E+00 0.00E+00 4.02E-05 4.02E-05 0.00E+00 0.00E+00 6.06E-05 6.06E-05 ALPHA. TRITIUM & OTHER ALPHA 0.00E+00 0.00E+00 4.23E-07 4.23E-07 0.00E+00 0.00E+00 2.80E-06 2.80E-06 TRITIUM 2.77E-01 7.83E-02 0.00E+00 3.55E-01 3.18E-02 1.40E-02 0.00E+00 4.59E-02 GROSS BETA / GAMMA 0.00E+00 0.00E+00 1.98E-05 1.98E-05 0.00E+00 0.00E+00 3.31E-05 3.31E-05 4

. - _ - - _ - -... - - - -. _ _. ~ ~ - -. -.-.

- ~ -.. -... -.

i TAILE 2A

-1 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 80 1 QUARTER 2 QUARTER 6

A.

FISSION & ACTIVATION PRODUCTS i

TOTAL RELEASE (NO TRITIUM, GAS, ALPHA)

CI 1.53E-01 5.72E-02 AVG DILUTED CONCENTRATION-UCI/ML 1.59E-09 6.55E-10 PERCENT OF LIMIT 10 CFR 20 APP. B= 1.0E-07 1.59E+00 6.55E-01 B.

TRITIUM l

TOTAL RELEASE CI 8.51E+00 2.60E+00 AVG DILUTED CONCENTRATION UCI/ML 8.86E-08 2.98E-08 PERCENT OF LIMIT 10 CFR 20, APP. B = 3.0E-03 2.95E-03 9.92E-04 C.

DISSOLVED & ENTRAINED GASES TOTAL RELEASE CI 5.30E-01 3.34E-03 AVG DILUTED CONCENTRATION UCI/ML 5.52E-09 3.83E-11 l

j PERCENT OF LIMIT TECH SPEC = 2 OE-04 UCI/ML 2.76E-03' 1.91E-05 i

D.

GROSS ALPHA RADICACTIVITY TOTAL RELEASE CI 6.54E-06 7.85E-06 E.

VOLUME OF WASTE RELEASE PRIOR TO DIL.

LITERS 6.69E+06 7.00E+06 T

F.

VOLUME OF DILUTION WATER THIS PERIOD LITERS 9.60E+10 8.73E+10 H

b 4

J h

m v

l i

TAELE 23 EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 80 1 QUARTER 2 QUARTER NUCL10ES IN CURIES CONT SATCH CONT BATCH STRONTIUM-89 2.21E-05 1.37E-05 2.84E-07 5.17E-10 STRONTIUM-90 4.85E-05 1.53E-04 5.67E-07 5.63E-10 COBALT-57 4.33E-05 3.06E-04 8.33E-05 2.43E-04 MOLY 80ENUM-99 3.82E-05 3.45E-04 7.08E-05 5.15E-05 TECHNETIUM-9SM 1.85E-05 1.68E-04 3.44E-05 2.50E-05 CERIUM-141 7.08E-05 4.36E-04 1.29E-04 2.69E-04 TIN-117M 3.97E-05 2.37E-04 7.58E-05 1.48E-04 7

CHROMIUM-51 6.51E-04 3.35E-03 5.33E-04 1.56E-03 IODINE-131 8.16E-05 1.66E-02 8.29E-05 1.69E-04 IODINE-133 1.18E-04 1.14E-03 1.04E-04 1.30E-04 8ARIUM-140 1.20E-04 9.14E-04 1.79E-04 3.37E-04 RUTHENIUM-103 4.89E-05 2.90E-04 8.15E-05 2.03E-04 CESIUM-137 5.31E-05 5.09E-02 8.63E-05 2.54E-02 ZIRCONIUM-95 8.32E-05 4.02E-04 1.48E-04 1.46E-04 NIOBIUM-95 4.98E-05 1.32E-03 7.44E-05 1.94E-04 CESIUM-134 5.46E-05 3.47E-02 9.45E-05 1.29E-02 COSALT-58 2.08E-04 3.33E-02 8.82E-05 9.55E-03 MANGANESE-54 4.42E-05 1.98E-03 9.49E-05 1.39E-03 CESIUM-136 6.50E-05 1.03E-03 1.14E-04 5.88E-05 IRON-59 9.48E-05 2.62E-04 1.48E-04 1.10E-04 ZINC-65 1.17E-04 2.54E-04 1.99E-04 9.68E-05 COSALT-60 5.30E-05 1.87E-03 7.57E-05 1.45E-03 LANTHANUM-140 6.18E-05 2.25E-04 8.41E-05 2.72E-05 ANTIMONY-124 4.24E-05 3.46E-04 9.18E-05 8.40E-05 TOTAL FOR PERIOD 2.23E-03 1.51E-01 2t67E-03 5.45E-02 DISSOLVED GASES ENTRAINED GASES XENON-133' 3.06E-04 5.23E-01 3,16E-04' 2.41E-03 XENON-135

- 8.24E-05 7.92E-03 6.95E-05 5.47E-04 TOTAL FOR PERIOD 3.88E-04 5.33E-01 3.85E-04 2.96E-03 OTHER. ALPHA S TRITIUM ALPHA 9.79E-07 5.56E-06 2.49E-06 5.36E-06 TRITIUM 5.94E-04 8.51E+00 2.43E-02 2.57E+00 GROSS BETA / GAMMA O.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD 5.95E-04 8.51E+00 2.43E-02 2.57E+00 AVG. CONC. IN UCI/ML ALPHA 1.25E-14 i,75E-12 3.53E-14 1.14E-12 TRITIUM _

7.56E-12 2.90E-06 3.44E-10 6.55E-07 1

1 l

l

,__,.m

a....

_, _,, _. ~ -,. -. _

m_

..__m..

_,__-.m,m..

_..m

... -.s.

TABLE 1A EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 80 3 QUARTER 4 QUARTER NUCLICES IN CURIES CONT DECAV RM060 TOTAL CONT DECAV RM060 TOTAL A.

FISSION & ACTIVATION GASES TOTAL RELEASE CI 8.27E+01 1.01E-01 0.00E+00 8.28E+01 6.15E+01 2.44E-01 0.00E+00 6.18E+01 F

AVG RELEASE RATE FOR PERIOD UCI/SEC 1.04E+01 1.27E-02 0.00E+00 1.04E+01 7.74E+00' 3.06E-02 0.00E+00 7.77E+00 PERCENT OF LIMIT t

TECH SPEC = NONE 0.

IODINES I

TOTAL RELEASE IODINE - 131 CI O.00E+00 0.00E+00 3.04E-04. 3.04E-04 0.00E+00 0.00E+00 2.84E-05 2.84E-05 AVG RELEASE RATE.

FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 3.82E-05 3.82E-05 0.00E+00 0.00E+00 3.58E-06 3.58E-06 t

PERCENT OF LIMIT TECH SPEC = NONE C.

PARTICULATES PARTICULATES WITH HALF LIVES.GT. 8 DAYS CI O.00E+00 0.00E+00 1.23E-05 1.23E-05 0.00E+00 0.00E+00 1.75E-05 1.75E-05 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 1.55E-06 1.55E-06 0.00E*00 0.00E+00 2.20E-06 2.20E-06 PERCENT OF LIMIT TECH SPEC = NONE 3

GROSS ALPHA RAOIOACTIVITY

-CI O.00E+00 0.00E+00 3.29E-06 3.29E-06 0.00E+00 0.00E+00 1.19E-06 1.19E-06 D.

TRITIUM TOTAL RELEASE CI 1.85E-01 1.40E-03 0.00E+00 1.86E-01 6.97E-01 1.60E-02 0.00E+00 7.13E-01 AVG RELEASE RATE FOR PERIOD UCI/SEC 2.32E-02 1.77E-04 0.00E+00 2.34E-02 8.77E-02 2.01E-03 0.00E+00 8.97E-02 PERCENT OF LIMIT TECH SPEC = NOME

m. _ _,. -. _,,,., _,,. _... _,. _ _.,

.__m

__..__..._.___._.___._________.____.___m.m__-____._

________m_._.____

_ _.-_._. _ __.=._

m__.

i TABLE IC i

EFFLUENT AND CASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMI ANNUAL FOR JULY THRU DEC 80 i

3 QUARTER 4 QUARTER l

NUCLIDES IN CURIES CONT DECAV RM060 TOTAL CONT DECAY RM060 TOTAL

}

FISSION GASES l

XENON-133 8.01E+01 5.41E-02 0.00E+00 8.02E+01 5.71E+01 2.02E-01 0.00E+00 5.73E+01 KRYPTON-85M 8.33E-03 2.53E-06 0.00E+00 8.33E-03 8.19E-03 3.90E-06 0.00E+00 8.19E-03 XENON-131M 1.50E-01 4.25E-04 0.00E+00 1.51E-01 1.17E+00 2.25E-04 0.00E+00 1.17E+00 KRYPTON-88 5.69E-03 5.12E-06 0.00E+00 5.70E-03 2.24E-02 3.03E-06 0.00E+00 2.24E-02 XENON-133M 4.08E-01 3.29E-04 0.00E+00 4.09E-01 2.76E-01 2.89E-04 0.00E+00 2.77E-01 XENON-135 3.42E-01 6.55E-06 0.00E+00 3.42E-01 3.73E-01 1.10E-06 0.00E+00 3.73E-01 i

KRYPTON-87 4.68E-03 3.98E-06 0.00E+00 4.69E-03 3.70E-03 1.48E-06 0.00E+00 3.70E-03 XENON-138 4.63E-03 1.80E-05 0.00E+00 4.65E-03 9.56E-03 1.16E-06 0.00E+00 9.56E-03 r

KRYPTON-85 1.18E+00 4.60E-02 0.00E+00 1.22E+00 2.04E+00 4.15E-02 0.00F+00 2.08E+00 XENON-135M 2.00E-03 3.46E-06 0.00E+00 2.01E-03 3.45E-03 4.99E-07 0.00E+00 3.45E-03 ARGON-41 5.08E-01 1.46E-06 0.00E+00 5.08E-01 5.67E-01 3.10E-07 0.00E+00 5.67E-01 TOTAL FOR PERIOD 8.27E+01 1.01E-01 0.00E+00 8.28E+01 6.15E+01 2.44E-01 0.00E+00 6.18E+01 IODINES IODINE-131 CTD.

0.00E+00 0.00E+00 3.04E-04 3.04E-04 0.00E+00 0.00E+00 2.84E-05 2.84E-05 IODINE-133 CTD.

0.00E+00 0.00E+00 6.73E-05 6.73E-05 0.00E+00 0.00E+00 1.52E-05 1.52E-05 j

IODINE-135 CTD.

0.00E+00 0.00E+00 7.08E-06 7.08E-06 0.00E+00 0.00E+00 2.68E-05 2.68E-05 TOTAL FOR PERIOD O.00E+00 0.00E+00 3.78E-04 3.78E-04 0.00E+00 0.00E+00 7.04E-05 7.04E-05 PARTICULATES STRONTIUM-89 0.00E+00 0.00E+00 7.25E-18 7.25E-18 0.00E+00 0.00E+00 5.46E-17 5.46E-17 STRONTIUM-90 0.00E+00 0.00E+00 7.25E-18 7.25E-18 0.00E+00 0.00E+00 9.08E-18 9.08E-18 r

j IODINE-131 PRF.

0.00E+00 0.00E+00 6.92E-07 6.92E-07 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IODINE-133 PRF.

C.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 BARIUM-140 0.00E+00 0.00E+00 4.65E-06 4.65E-06 0.00E+00 0.00E+00 6.00E s6 6.00E-06 CESIUM-137 0.00E+00 0.00E+00 3.07E-06 3.07E-06 0.00E+00 0.00E+00 4.35E-06 4.35E-06 CESIUM-134 0.00E+00 0.OOE+00 2.06E-06 2.06E-06 0.00E+00 0.00E+00 3.02E-06 3.02E-06 COBALT-58 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 i

MAN 3ANESE-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COSALT-60 0.00E+00 0.00E+00 0.00E+00 0 OOE+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IODINE-135 PRF.

0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LANTHANUM-140 0.00E+00 0.00E+00 1.82E-06 1.82E-06 0.00E+00 0.00E+00 4.13E-06 4.13E-06 TOTAL FOR PERIOD 0.00E+00 0.00E+00 1.23E-05 1.23E-05 0.00E+00 0.00E+00 1.75E-05 1.75E-05 l

ALPHA. TRITIUM & OTHER ALPHA O.00E+00 0.00E+00 3.29E-06 3.29E-06 0.00E+00 0.00E+00 1.19E-06 1.19E-06 TRITIUM 1.85E-01 1.40E-03 0.00E+00 1.86E-01 6.97E-01 1.60E-02 0.00E+00 7.13E-01 f

GROSS BETA / GAMMA 0.00E+00 0.00E+00 1.71E-05 1.71E-05 0.00E+00 0.00E+00 6.91E-06 6.91E-06 I

i d

t l

i I

l

{

TA!LE 2A EFFLUENT AND CASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 80 3 QUARTER 4 QUARTER A.

FISSION & ACTIVATION PRODUCTS TOTAL RELEASF (NO TRITIUM. GAS. ALPHA)

CI

2.28E-01 6.62E-02 AVG DitUTED CONCENTRATf0N UCI/ML 6.39E-10 1.85E-10 PERCENT OF LIMIT 10 CFR 20 APP.

B=

1.0E-07 6.39E-01 1.85E-01 9.

TRITIUM TOTAL RELEASE CI 2.27E+01 2.06E+01 AVG DILUTED CONCENTRATION UCI/ML 6.35E-08 5.77E-08 PERCENT OF LIMIT 10 CFR 20 APP. B = 3.0E-03 2.12E-03 1.92E-03 C.

DISSOLVED & ENTRAINED GASES TOTAL RELEASE CI 4.77E-01 3.59E-02 AVG DILUTED CONCENTRATION UCIsML 1.34E-09 1.01E-10 PERCENT OF LIMIT TECH SPEC = 2.0E-04 UCI/ML 6.68E-04 5.03E-05 D.

GROSS ALPHA RADI0 ACTIVITY l

TOTAL RELEASE C1 1.87E-05 1.58E-05 E.

VOLUME OF WASTE RELEASE PRIOR TO DIL.

LITERS 2.31E+07 2.14E+07 F.

VOLUME OF DILUTION WATER THIS PERIOD LITERS 3.57E+11 3.57E+11 l

~

'T s

- +.-, -,,,

-vs-

l TAILE 23 EFFLUENT AND CASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 80 3 QUARTER 4 QUARTER NUCLIDES IN CURIES CONT SATCH CONT BATCH STRONTIUM-89 2.15E-05 2.38E-05 1.16E-09 2.22E-10 STRONTIUM-90 2.15E-05 2.86E-05 1.16E-09 7.41E-10 COSALT-57 3.52E-04 2.19E-04 2.56E-04 1.32E-04 MOLV8DENUM-99 3.10E-04 5.35E-05 2.00E-04 4.30E-05 TECHNETIUM-99M 1.51E-04 2.60E-05 9.70E-05 2.09E-05 CERIUM-141 7.38E-03 3.04E-04 4.53E-04 1.61E-04 TIN-117M 3.12E-04 2.52E-04 2.41E-04 8.84E-05 CHROMIUM-51 2.78E-03 1.62E-03 2.70E-03 7.87E-04 IOOINE-131 3.73E-04 3.80E-02 2.75E-04 4.47E-03 IODINE-133 3.61E-04 2.01E-04 2.85E-04 9.50E-05 CARIUM-140 9.70E-04 4.43E-04 7.48E-04 2.34E-04 RUTHENIUM-103 3.80E-04 1.82E-04 3.21E-04 1.33E-04 CESIUM-137 4.30E-04 1.06E-01 3.47E-04 3.21E-02 ZIRCONIUM-95 6.14E-04 1.37E-04 4.70E-04 7.97E-05 NIOBIUM-95 3.49E-04 8.17E-05 2.60E-04 5.42E-05 CESIUM-134 4.22E-04 5.69E-02 3.25E-04 1.58E-02 COSALT-58 3.43E-04 8.01E-04 2.75E-04 6.13E-04 MANGANESE-54 4.14E-04 2.02E-03 2.71E-04 5.27E-04 CESIUM-136 4.46E-04 7.12E-04 3.45E-04 4.61E-05 IRON-59 7.03E-04 8.91E-05 5.43E-04 6.64E-05 ZINC-65 8.86E-04 1.02E-04 6.70E-04 7.64E-05 COSALT-60 3.60E-04 8.93E-04 2.17E-04 6.77E-04 LANTHANUM-140 3.09E-04 2.16E-05 2.23E-04 4.17E-05 CNTIMONY-124 3.77E-04 6.08E-05 3.35E-04 7.92E-05 TOTAL FOR PERIOD 1.91E-02 2.09E-01 9.8cE-03 5.63E-02 DISSOLVED GASES ENTRAINED GASES XENON-133 7.29E-02 4.02E-01 1.42E-03 2.66E-02 XENON-135 3.23E-04 1.55E-03 6.82E-03 1.08E-03 TOTAL FOR PERIOD 7.32E-02 4.04E-01 8.24E-03 2.77E-02 OTHER, ALPHA & TRITIUM ALPHA 1.81E-05 6.02E-07 1.31E-05 2.68E-06 TRITIUM 1.91E-02 2.26E+01 1.81E-02 2.06E+01 GROSS BETA / GAMMA O.00E+00 0.00E+00 0.00E+00 0.OOE+00 TOTAL FOR PERIOD 1.91E-02 2.26E+01 1.81E-02 2.06E+01 AVG. CONC. IN UCI/ML ELPHA 3.99E-13 2.57E-13 2.91E-13 1.69E-12 TRITIUM 4.59E-10 9.63E-06 2.35E-10 1.27E-05