SUPPLEMENTAL MATERIAL FOR 1982 SEMI-ANNUAL REPORTS 8606190726 860528 PDR ADOOK 05000205
1
- (
TABLE 1A EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 82 1 QUARTER 2 QUARTER NUCLIDES IN CURIES CONT DECAY RuO60 TOTAL CONT OECAY RMO60 TOTAL A.
FISSION & ACTIVATION GASES TOTAL PELEASE CI 3.35E+01 0.00E+00 0.00E+00 3.35E+01 8.52E+01 4.34E-01 0.00E+00 8.56E+01 AVG RELEASE RATE FOR PERIOD UCI/SEC 4.31E+00 0.00E+00 0.00E+00 4.31E+00 1.08E+01 5.52E-02 0.00E+00 1.09E+01 PERCENT OF LIMIT TECH SPEC = NONE S.
IODINES TOTAL RELEASE IOOINE - 131 CI 0.00E+00 0.00E+00 2.40E-04 2.40E-04 0.00E+00 0.00E+00 3.73E-04 3.73E-04 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 3.00E-05 3.08E-05 0.00E+00 0.00E+00 4.75E-05 4.75E-05 PERCENT OF LIMIT TECH SPEC = NONE C.
PARTICULATES PARTICULATES WITH HALF LIVES.GT. 8 DAYS CI 0.00E+00 0.00E+00 1.04E-05 1.04E-05 0.00F+00 0.00E+00 1.18E-05 1.18E-05 AVG RELEASE RATE FOR PERIOO UCI/SEC O.00E+00 0.00E+00 1.34E-06 1.34E-06 0.00E+00 0.00E+00 1.50E-06 1.50E-06 PERCENT OF LIMIT TECH SPEC = NONE GROSS ALPHA CAOIDACTIVITY CI 0.00E+00 0.00E+00 2.13E-07 2.13E-07 0.00E+00 0.00E+00 1.42E-07 1.42E-07 D.
TRITIUM TCTAL RELEASE CI 2.95E+00 0.00E+00 0.00E+00 2.95E+00 1.12E+00 1.18E-02 0.00E+00 1.13E+00 AVG RELEASE RATE FOR PERIDO UCI/SEC 3.79E-01 0.00E+00 0.00E+00 3.79E-01 1.42E-01 1.50E-03 0.00E+00 1.44E-01 PERCENT OF LIMIT TECH SPEC = NONE i
4 TABLE IC EFFLUENT ANO WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SurMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 82 1 QUARTER 2 OUARTER NUCL10ES IN CURIES CONT OECAY RM060 TOTAL CONT OECAV RM060 T O T A L-FISSION GASES XENON-133 3.02E+01 0.r;0E+00 0.00E+00 3.02E+01 7.90E+01 1.15E-01 0.00E+00 7.91E+01 KRYPTON-85M 3.34E-03 0.00E+00 0.00E+00 3.34E-03 9.45E-02 7.62E-06 0.00E+00 9.46E-02 XENON-131M 3.55E-01 0.00E+00 0.OOE+00 3.55E-01 1.12E+00 1.09E-02 0.00E+00 1.13E+00 KRYPTON-88 8.00E-03 0.00E+00 0.00E+00 8.00E-03 5.18E-02 1.49E-05 0.00E+00 5.18E-02 XENON-133M 1.92E-01 0.00E+00 0.00E+00 1.92E-01 5.17E-01 1.71E-04 0.00E+00 5.17E-01 XENON-135 5.21E-01 0.00E+00 0.00E+00 5.21E-01 1.49E+00 6.02E-06 0.00E+00 1.49E+00 KRYPTON-87 7.44E-03 0.00E+00 0.00E+00 7.44E-03 2.99E-02 1.37E-05 0.00E+00 2.99E-02 1
XENON-138 2.14E-02 0.00E+00 0.00E+00 2.14E-02 2.71E-02 4.59E-05 0.00E+00 2.72E-02 KRYPTON-85 7.15E-01 0.00E+00 0.00E+00 7.15E-01 9.12E-01 3.08E-01 0.00E+00 1.22E+00 XENON-135M 7.18E-03 0.00E+00 0.00E+00 7.18E-03 8.49E-03 9.98E-06 0.00E+00 8.50E-03 ARGON-41 1.45E+00 0.00E+00 0.00E+00 1.45E+00 1.99E+00 3.26E-06 0.00E+00 1.99E+00 TOTAL FOR PERIOD 3.35E+01 0.00E+00 0.00E+00 3.35E+01 8.52E+01 4.34E-01 0.00E+00 8.56E+01 IODINES i
100!NE-131 CTO.
0.00E+00 0.00E+00 2.40E-04 2.40E-04 0.00E+00 0.00E+00 3.73E-04 3.73E-04 100!NE-133 CTO.
0.00E+00 0.00E+00 2.34E-06 2.34E-06 0.00E+00 0.00E+00 2.32E-05 2.32E-05 IODINE-135 CTO.
0.00E+00 0.00E+00 1.02E-05 1.02E-05 0.00E+00 0.00E+00 9.68E-06 9.68E-06 TOTAL FOR PERICO 0.00E+00 0.00E+00 2.52E-04 2.52E-04 0,00E+00 0.00E+00 4.06E-04 4.06E-04 PARTICULATES STRONTIUM-89 0.00E+00 0.00E+00 9.61E-17 9.61E-17 0.00E+00 0.00E+00 1.43E-17 1.43E-17 STRONTIUM-90 0.00E+00 0.00E+00 1.82E-16 1.82E-16 0.00E+00 0.00E+00 3.76E-17 3.76E-17 IODINE-131 PRF.
0.00E+00 0.00E+0C 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IODINE-133 PRF.
0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+C0 0.00E+00 0.00E+00 SARIUM-140 0.00E+00 0.00E+00 4.23E-06 4.23E-06 0.00E+00 0.00E+00 4.67E-06 4.67E-06 CESIUM-137 0.00E+00 0.00E+00 2.25E-06 2.25E-06 0.00E+00 0.00E+00 3.27E-06 3.27E-06 CESIUM-134 0.00E+00 0.00E+00 2.06E-06 2.06E-06 0.00E+00 0.00E+00 2.26E-06 2.26E-06 COBALT-58 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0,00E+00 0.00E+00 0.00E+00 0.00E+00 MANGANESE-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C05 ALT-60 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IODINE-135 PRF.
0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LANTHANUM-140 0.00E+00 0.00E+00 1.88E-06 1.88E-06 0.00E+00 0.00E+00 1.58E-06 1.58E-06 TOTAL FOR PERIOD O.00E+00 0.00E+00 1.04E-05 1.04E-05 0.00E+00 0.00E+00 1.18E-05 1.18E-05 ALPHA, TRITIUM & OTHER ALPHA 0.00E+00 0.00E+00 2.13E-07 2.13E-07 0.00E+00 0.00E+00 1.42E-07 1.42E-07 TRITIUM 2.95E+00 0.00E+00 0.00E+00 2.95E+00 1.12E+00 1.18E-02 0.00E+00 1.13E+00 GROSS BETA / GAMMA 0.00E+)O 0.00E+00 2.98E-05 2.98E-05 0.00E+00 0.00E+00 1.36E-04 1.36E-04 D
w
d TAILE 2A EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 82 1 QUARTER 2 QUARTER l
A.
FISSION & ACTIVATION PRODUCTS l
TOTAL RELEASE (NO I
TRITIUM. GAS ALPHA)
CI 3.23E-02 2.87E-02 a
AVG DILUTED f
CONCENTRATION UCI/ML 9.79E-11 9.15E-11 1
PERCENT OF LIMIT 10 CFR 20, APP. B=
1.CE-OT 9.79E-02 9.15E-02 g
8.
TRITIUM TOTAL RELEASE CI 2.07E+01 1.89E+02 AVG OILUTED CONCENTRATION UCI/ML 6.27E-08 6.01E-07 PERCENT OF LIMIT 10 CFR 20, APP. B = 3.0E-03 2.09E-03 2.00E-02 C.
DISSOLVED & ENTRAINED CASES TOTAL RELEASE CI 1.25E+00 1.72E-01 AVG OILUTED CONCENTRATION UCI/ML 3.80E-09 5.48E-10 PERCENT OF LIMIT TECH SPEC = 2.0E-04 UCI/ML 1.90E-03 2.74E-04 D.
GROSS ALPHA RADIOACTIVITY TOTAL RELEASE CI 2.22E-05 4.47E-06 E.
VOLUME OF WASTE RELEASE PRIOR TO DIL.
LITERS 2.01E+07 2.25E+07 F.
VOLUME OF DILUTION WATER THIS PERIOD LITERS 3.30E+11 3.14E+11
4 TABLE 2B EFFLUENT AND WASTE DISPOSAL REPORT LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JAN THRU JUN 82 1 QUARTER 2 OUARTER NUCLIDES IN CURIES CONT BATCH CONT BATCH STRONTIUM-89 1.96E-07 2.54E-09 5.83E-09 3.41E-10 STRONTIUM-90 2.18E-07 2.54E-09 3.80E-08 1.59E-09 COSALT-57 4.35E-04 1.20E-04 4.93E-04 8.16E-05 MOLYBDENUM-99 3.68E-04 9.90E-05 3.28E-04 6.14E-05 TECHNETIUM-99M 1.79E-04 4.81E-05 1.60E-04 2.98E-05 CERIUM-141 7.35E-04 1.87E-04 8.24E-04 1.33E-04 TIN-117M 3.91E-04 1.09E-04 4.14E-04 7.36E-05 CHROMIUM-51 3.3SE-03 8.03E-04 3.47E-03 6.15E-04 IOOINE-131 8.17E-04 4.47E-04 4.05E-04 2.00E-03 IODINE-133 4.48E-04 1.11E-04 3.75E-04 7.69E-05 BARIUM-140 1.10E-03 2.85E-04 9.96E-04 2.00E-04
.0UTHENIUM-103 4.38E-04 1.06E-04 3.81E-04 7.58E-05 CESIUM-137 5.51E-04 5.05E-03 8.75E-04 6.06E-03 ZIRCONIUM-95 7.91E-04 1.26E-04 6.70E-04 1.55E-04 NIOSIUM-95 4.11E-04 7.44E-05 3.38E-04 4.64E-05 CESIUM-134 4.56E-04 2.61E-03 6.14E-04 3.07E-03 g
COSALT-58 4.56E-04 5.73E-03 3.85E-04 8,22E-04 MANGANESE-54 4.24E-04 1.85E-04 3.69E-04 4.67E-05 CESIUM-136 5.55E-04 7.77E-05 4.63E-04 6.66E-05 IRON-59 8.10E-04 1.15E-04 7.38E-04 8.10E-05 ZINC-65 1.04E-03 1.34E-04 9.77E-04 9.20E-05 COSALT-60 3.70E-04 7.07E-04 4.58E-04 3.78E-04 LANTHANUM-140 3.82E-04 3.19E-05 2.75E-04 2.61E-05 ANTIMONY-124 4.30E-04 1.63E-04 4.37E-04 1.15E-04 TOTAL FOR PERIOD 1.49E-02 1.73E-02 1.44E-02 1.43E-02 DISSOLVED GASES ENTRAINED GASES XENON-133 1.66E-03 1.25E+00 2.44E-03 1.67E-01 XENON-135 3.76E-04 4.69E-03 3.77E-04 1.95E-03 TOTAL FOR PERIOD 2.04E-03 1.25E+00 2.81E-03 1.69E-01 OTHER. ALPHA & TRITIUM ALPHA 6.92E-06 1.52E-05 3.56E-06 9.16E-07 TRITIUM 1.14E-02 2.07E+01 6.03E-02 1.89E+02 GROSS BETA / GAMMA O.00E+00 0.00E+00 0.00E+00 0.00E+00 i
TOTAL FOR PERIOD 1.14E-02 2.07E+01 6.03E-02 1.89E+02 I
AVG. CONC. IN UCI/ML ALPHA 1.48E-13 9.44E-12 9.29E-14 5.43E-13 TRITIUM 2.23E-10 7.69E-06 1.23E-09 1.10E-04
4 TABLE 1A EFFLUENT AND WASTE DISPOSAL REPORT CASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 82 3 OUARTER 4 QUARTER NUCLIDES IN CURIES CONT DECAY RMO60 TOTAL CONT DECAY RM060 TOTAL A.
FISSIONLACTIVATION GASES
.T3TAL RELEASE CI 1.08E+02 8.76E-01 0.00E+00 1.09E+02 1.14E+02 3.39E+00 0.00E+00 1.18E+02 I
AVG RELEASE RATE i
FOR PERIOD UCI/SEC 1.36E+01 1.10E-01 0.00E+00 1.37E+01 1.44E+01 4.26E-01 0.00E+00 1.48E+01 1
PERCENT OF LIMIT TECH SPEC = NONE 0.
IODINES L
TOTAL RELEASE IODINE - 131 CI O.00E+00 0.00E+00 1.12E-04 1.12E-04 0.00E+00 0.00E+00 7.90E-04 7.90E-04 AVG RELEASE RATE FOR PERIOD UCI/SEC 0.00E+00 0.00E+00 1.41E-05 1.41E-05 0.00E+00 0.00E+00 9.94E-05 9.94E-05 PERCENT OF LIMIT TECH SPEC = NONE C.
PARTICULATES PARTICULATES WITH HALF LIVES.GT. 8 OAYS CI 0.00E+00 0.00E+00 1.47E-05 1.47E-05 0.00E+00 0.00E+00 1.07E-05 1.07E-05 AVG RELEASE RATE FOR PERIGO UCI/SEC 0.00E+00 0.00E+00 1.85E-06 1.85E-06 0.00E+00 0.00E+00 1.35E-06 1.35E-06 PERCENT OF LIMIT TECH SPEC = NOME GROSS ALPHA CADI0 ACTIVITY CI O.00E+00 0.00E+00 1.90E-07 1.90E-07 0.00E+00 0.00E+00 3.61E-07 3.61E-07 D.
TRITIUM TOTAL RELEASE CI 5.22E-01 1.23E-01 0.00E+00 6.44E-01 3.90E-01 6.43E-02 0.00E+00 4.54E-01 AVG RELEASE RATE FOR PERIOD UCI/SEC 6.57E-02 1.54E-02 0.00E+00 8.11E-02 4.90E-02 8.09E-03 0.00E+00 5.71E-02 PERCENT OF LIMIT TECH SPEC = NONE I
I t
TOBLE IC EFFLUENT AND WASTE DISPOSAL REPORT GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 82 3 OUARTER 4 OUARTER NUCLIDES IN CURIES CONT DECAY RMO60 TOTAL CONT DECAY RMO60 TOTAL FISSION GASES XENON-133 9.95E+01 4.27E-01 0.00E+00 1.00E+02 1.05E+02 1.48E+00 0.00E+00 1.06E+02 KRYPTON-85M 1.43E-01 2.32E-05 0.00E+00 1.43E-01 3.28E-02 1.85E-04 0.00E+00 3.30E-02 XENON-131M 1.62E+00 3.24E-02 0.00E+00 1.65E+00 1.60E+00 1.37E-01 0.00E+00 1.74E+00 KRYPTON-88 8.70E-02 2.23E-05 0.00E+00 8.71E-02 3.52E-02 3.39E-04 0.00E+00 3.55E-02 XENON-133m 6.48E-01 2.35E-03 0.00E+00 6.50E-01 5.47E-01 2.38E-03 0.00E+00 5.50E-01 XENON-135 1.88E+00 3.01E-05 0.00E+00 1.88E+00 5.26E-01 1.26E-04 0.00E+00 5.26E-01 KRYPTON-87 4.15E-02 1.55E-05 0.00E+00 4.15E-02 2.13E-02 2.41E-04 0.00E+00 2.16E-02 XENON-138 3.08E-02 5.75E-05 -0.00E+00 3.08E-02 5.03E-02 1.18E-03 0.00E+00 5.15E-02 KRYPTON-85 1.71E+00 4.15E-01 0.00E+00 2.13E+00 5.61E+00 1.77E+00 0.COE+00 7.38E+00 XENON-135m 1.02E-02 1.38E-05 0.00E+00 1.02E-02 1.40E-02 3.26E-04 0.00E+00 1.44E-02 ARGON-41 2.12E+00 4.64E-06 0.00E+00 2.12E+00 8.35E-01 1.73E-03 0.00E+00 8.37E-01 TOTAL FOR PERIOD 1.08E+02 8.76E-01 0.00E+00 1.09E+02 1.14E+02 3.39E+00 0.00E+00 1.18E+02 IODINES IODINE-131 CTD.
0.00E+00 0.00E+00 1.12E-04 1.12E-04 0.00E+00 0.00E+00 7.90E-04 7.90E-04 IODINE-133 CTD.
0.00E+00 0.00E+00 3.18E-06 3.18E-06 0.00E+00 0.00E+00 3.04E-04 3.04E-04 IODINE-135 CTO.
0.00E+00 0.00E+00 1.38E-05 1.38E-05 0.00E+00 0.00E+00 6.14E-06 6.14E-06 TOTAL FOR PERIOD 0.00E+00 0.00E+00 1.29E-04. 1.29E-04 0.00E+00 0.00E+00 1.10E-03 1.10E-03' PARTICULATES STRONTIUu-89 0.00E+00 0.00E+00 1.73E-17 1.73E-17 0.00E+00 0.00E+00 6.40E-18 6.40E-18
. STRONTIUM-90 0.00E+00 0.00E+00 2.42E-17 2.42E-17 0.00E+00 0.00E+00 7.99E-18 7.99E-18 IODINE-131 PRF.
0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 IODINE-133 PRF.
0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 SARIUM-140 0.00E+00 0.00E+00 6.19E-06 6.19E-06 0.00E+00 0.00E+00 4.70E-06 4.70E-06 CESIUM-137 0.00E+00 0.00E+00 2.91E-06 2.91E-06 0.00E+00 0.00E+00 2.32E-06 2.32E-06 CESIUM-134 0.00E+00 -0.00E+00 3.03E-06 3.03E-06 0.00E+00 0.00E+00 2.27E-06 2.27E-06 COSALT-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 MANGAMESE-54 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 COSALT-60 0.00E+00 -0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00- 0.00E+00 0.00E+00 IODINE-135 PRF.
0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 LANTHANUM-140 0.00E+00 0.00E+00 2.61E-06 2.61E-06 0.00E+00 0.00E+00 1.41E-06 1.41E-06 TOTAL FOR PERIOD 0.00E+00 0.00E+00 1.47E-05 1.47E-05 0.00E+00 0.00E+00 1.07E-05 1.07E-05 i
ALPHA TRITIUM & OTHER ALPHA 0.00E+00 0.00E+00 1.90E-07 1.90E-07 0.00E+00 0.00E+00 3.61E-07 3.61E-07 TRITIUM 5.22E-01 1.23E-01 0.00E+00 6.44E-01 3.90E-01 6.43E-02 0.00E+00 4.54E-01 GROSS BETA / GAMMA 0.00E+00 0.00E+00 1.03E-05 1.03E-05 0.00E+00 0.00E+00 6.55E-06 6.55E-06 l
v I
t I
1
_~.
l TAILE 2A i
EFFLUENT AND WASTE DISPOSAL REPORT 1
i i
LIQUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU OEC 82 l
3 QUARTER 4 QUARTER l
A.
FISSION & ACTIVATION PRODUCTS I
TOTAL RELEASE (NO TRITIUM. GAS. ALPHA)
CI 2.92E-02 8.86E-02 AVG DILUTED CONCENTRATION UCI/ML 8.18E-11 2.79E-10 PERCENT OF LIMIT 10 CFR 20. APP.
B=
1.OE-07 8.18E-02 2.79E-01 D.
TRITIUM TOTAL RELEASE CI 2.25E+01 7.54E+01 l
AVG DILUTED l
CONCENTRATION UCI/ML 6.31E-08 2.38E-07 PERCENT OF LIMIT 10 CFR 20. APP. B = 3.OE-03 2.10E-03 7.92E-03 C.
DISSOLVED & ENTRAINED GASES TOTAL RELEASE CI 1.41E-01 S.63E-01 AVG DILUTED CONCENTRATION UCI/ML 3.95E-10 1.77E-09 PERCENT OF LIMIT TECH SPEC = 2.OE-04 UCI/ML 1.98E-04 8.86E-04 D.
GROSS ALPHA RADIOACTIVITY TOTAL RELEASE CI 8.35E-06 2.19E-05 E.
VOLUME OF WASTE RELEASE i
PRIOR TO DIL.
LITERS 2.15E+07 1.46E+07 F.
VOLUME OF DILUTION WATER THIS PERIOD LITERS 3.57E+11 3.17E+11 i
l f
I
.4 TAILE 23 EFFLUENT AND WASTE DISPOSAL REPORT LIOUID EFFLUENTS-SUMMATION OF ALL RELEASES SEMIANNUAL FOR JULY THRU DEC 82 3 00ARTER 4 OUARTER NUCLIOES IN CURIES CONT 8ATCH CONT 8ATCH STRONTIUM-89 1.14E-08 8.96E-09 0.00E+00 4.01E-08 STRONTIUM-90 1.14E-08 1.56E-09 0.00E+00 3.89E-09 COBALT-57 3.99E-04 8.39E-04 2.87E-03 2.66E-04 MOLYBDENUM-99 3.24E-04 6.53E-05 2.60E-04 1.46E-04 TECHNETIUM-99M 1.57E-04 3.17E-05 1.26E-04 7.10E-05 CERIUM-141 6.50E-04 1.42E-04 6.36E-04 3.28E-04 TIN-187M 3.53E-04 8.59E-05 3.44E-04 1.89E-04 CHROMIUM-51 3.16E-03 6.92E-04 3.00E-03 1.54E-03 IODINE-131 3.96E-04 3.40E-04 3.62E-04 2.43E-03 IOOINE-133 3.92E-04 '9.58E-05 3.62E-04 2.11E-04 CARIUM-140 9.93E-04 2.27E-04 9.68E-04 5.73E-04 KUTHENIUM-103 3.90E-04 8.84E-05 3.50E-04 1.93E-04 CESIUM-137 5.04E-04 7.12E-03 8.57E-03 2.46E-02 ZIRCONIUM-95 6.70E-04 9.54E-05 6.27E-04 2.25E-04 NIO810M-95 4.13E-04 8.95E-05 3.25E-04 2.16E-04 CESIUM-134 4.34E-04 3.32E-03 4.07E-04 1.21E-02 COSALT-58 3.89E-04 1.20E-03 3.49E-04 6.58E-03 MANGAMESC-54 3.79E-04 1.20E-04 3.57E-04 6.37E-04 CESIUM-136 5.24E-04 6.47E-05 4.08E-04 5.95E-04 IRON-59 7.35E-04 9.70E-05. 6.38E-04 2.16E-04 ZINC-65 1.05E-03 1.10E-04 8.55E-04 2.39E-04 C08 ALT-60 4.05E-04 7.31E-04 1.04E-02 3.64E-03 LANTHANUM-140 3.73E-04 3.03E-05 4.97E-04 1.01E-04 ANTIMONY-124 4.09E-04 1.32E-04 4.60E-04 2.41E-04 TOTAL FOR PERIOD 1.35E-02 1.57E-02 3.32E-02 5.54E-02 DISSOLVED GASE5 kNTRAINED GASES-s XENON-133 1.31E-03 1.36E-01 4.55E-03 5.49E-01 i
XENON-135 3.24E-04 3.27E-03 3.17E-04 8.51E-03 TOTAL FOR PERIOD 1.64E-03 1.40E-01 4.86E-03 5.58E-01 OTHER, ALPHA & TRITIUM ALPHA 5.59E-06 2.76E-06 2.04E-05 1.56E-06 TRITIUM 1.92E-02 2.25E+01 2.19E-03 7.54E+01 GROSS BETA / GAMMA 0.00E+00 0.00E+00 0.00E+00 0.00E+00 TOTAL FOR PERIOD 1.92E-02 2.25E+01 2.22E-03 7.54E+01 AVG. CONC. IN UCI/ML ALPHA 8.52E-14 8.15E-13 2.71E-13 4.95E-13 I
TRITIUM 4.25E-10 8.81E-06 2.37E-11 2.64E-05
-