Text
c c/hc/n/
NOV 0 8 W Occket No. 70-1113 License No. SNM 1097 Genertl Electric Company ATTH: Mr. Eugene A. Lees, General Manager Nuclear Fuel and Component Manufacturing Depaatment P. O. Box 780 Wilnington, NC 28402 Gen *.l eme n:
SUBJECT:
NOTICE OF VIOLATION (NRC INSPECTION REPORT NO. 70-1113/88-17)
This refers to the Nuclear Regulatory Ccceissier (NRC) inspection conducted by P. G. Stoddart and C. A. Hughey on September 26-30, 1988.
The inspection included a review of activities authori:ed for your General Electric Nuclear Fuel Manufacturing acility. At the conclusion of the inspection, the findings were discusNd with those members of your staff identified in the enclosed inspection report.
Areas examined during the inspection are identified in the report.
Within these areas, the inspection consisted of selective examinations of procedures and representative records, irterviews with personnel, and cbservation of activities in progress.
The inspection findings indicate that certa 8a activities appeared to violate NRC requirements.
The violatien and refertices to pertinent requirements are described in the enclosed Notice of Violation.
It is the policy of the NRC to cite but not require a response to a Notice of Violation for violations of minor safety or envircreental concern identified by the inspector and for which, by the end of the inspection, the licensee had already taken or was in the process of taking adequate corrective actions to prevent recurrence; therefore, no response is required.
In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title 10. Ccde of Federal Regulations, a copy of this letter and its enclosures will be p Lced in the NRC Public Oncurent Room, e311150441 581108 pga ADOCL 07001113 gN C
FDL
o General Electric Corrpany 2
Should you have any questions concerning this letter, please contact us.
Sincerely, Douglas M. Collins, Acting Director Division of Radiation Safety and Safeguards
Enclosures:
1.
NRC Inspection Report cc w/encls:
vf. Preston Winslow Manager Licensing and tiuclear Materials Managerrent State of North Carolina s bcc w/o encls:
License fee Management Branch bec w/encls:
Docurrent Control Desk Rll Rl!
Ril l,, -
Rll Rll O//
b Il
, :N CHughey:ac P5tod, dart JAahl 10ecler EMcAlpine 1(/ /83 14/\\/88 ll/ 7 /88 10/;.f/ 88 10/y;/E8
\\