Amend 108 to License DPR-59,changing Tech Spec Table 3.7-1 to Reflect Installation of New Containment Isolation Valves
ML20206B305
Person / Time
Site: FitzPatrick 
(DPR-059)
Issue date: 04/03/1987
From: Muller D
Office of Nuclear Reactor Regulation
To:
Power Authority of the State of New York
Shared Package
ML20206B310 List:
References
DPR-59-A-108 NUDOCS 8704090067
Download: ML20206B305 (7)


Text

F.'

'o UNITED STATES 8N

'Ig NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D. C. 20555

%.'.O

,/

POWER AUTHORITY OF THE STATE OF NEW YORK DOCKET N0. 50-333 JAMES A. FITZPATRICK NUCLEAR POWER PLANT Af!ENDt1ENT TO FACILITY OPERATING LICENSE Amendment No.108 License No. DPR-59 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by the Power Authority of the State of New York (the licensee) dated December 19, 1986, as supplemented January 3, 1987, and March 13, 1987, complies with the standards and re as amended (the Act)quirements of the Atomic Energy Act of 1954,

, and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Prrt 51 of the Conmission's regulations and all applicable requirements have been satisfied.

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and paragraph 2.C.(2) of Facility Operating License No. DPR-59 is hereby amended to read as follows:

8704090067 870442 PDR ADOCK 05000333 P

PDR

z..

~

(2) Technical Specification The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 108, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

The license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION f,

4' Daniel R. Muller, Director BWR Project Directorate #2 Division of BWR Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance: April 3,1987

7,;

... ~

ATTACHMENT TO LICENSE AMENDMENT NO.108 FACILITY OPERATING LICENSE NO DPR-59 DOCKET NO. 50-333 Replace the following pages of the Appendix A Technical Specifications with the enclosed pages. The revised areas are indicated by marginal lines.

Pages 199 201 202 205 1

1 J

l l

i i

t 1

I

JAFNpP g

Tab 12 3.7-1 (Cont'd) i PROCESS PIPELIE PENETRATING PRIMRY CONTAIMENT (Numbers in parentheses are keyed to numbers on following pages: signal codes are If sted on following pages) i Power Location Power Closing Dryw11 Valve Type to Open Ref, to to Close Isolation Time Normal Remarks and Line Isolated '

Penetration (6)

(5) (6)

Group Drywell (5) (6)

Signal (7)

Status Exceptions l

Clif-purge to X-31Ac recirc pump X-31Bc 50 Valve Ac C

Outside Spring 8,F.M Not appilcable Open Nint-purge to X-31Ac recirc pump X-310c Check Process C

Inside Process Rev. flow Not appilcable Open RHR Reactor Shut-down Cooling supply X-12 M0 Gate Dc A

Outside De A.U.F.M 38 Sec Closed RM Aesctor Shut-down Cooling supply X-12 M0 Gate Ac A

Inside Ac A.U,F,RM 38 Sec Closed RHR to suppression Throttifog Type Spray Header X-211 A,8 M0 Globe Ac B

Outside Ac G.S.M 10 Sec Closed Valve Note (2) l RHR - Containment Spray X-39A,8 M0 Gate Ac B

Outstde Ac G.S.RM 10 Sec Closed Note (2) p RHR - Containment Spray X-39A,8 M0 Gate Ac B

Outstde Ac 3,5,M 10 Sec Closed Note (2)

Rt8R - Reactor Head Spray X-17 M0 Gate Ac A

Inside Ac A,U F.M 20 Sec Closed RHR - Reactor Head

]

Spray X-17 M0 Gate De A

Outstde De A U.F.M 20 Sec Closed R M to Suppression Thrott11pg Type i

Pool X-210A,8 MO Globe Ac 8

Outside Ac G.M 70 Sec Closed Valve Note (2)"

RHR - LPCI to l

Reactor X-13A,8 M0 Gate Ac A

Outstde Ac M

120 Sec Closed Note (10)

I R M - LPCI to Thrott11pg Type Reactor X-13A,8 MO Globe Ac A

Outside Ac M

g0 Sec Open Valve Note (10)

RM - LPCI to Testable check A

Inside Process Rev. flow Not applicable Closed Valve (3,16)

Reactor X-13A,8 A0 Check R M pump suct1on X-225A,8 M0 Gate Ac 3

Outside Ac M

Not applicable Open Ameneent No. pf, g 108 4

I

.p JAFNPP Table 3.7-1 (Cont'd)

PROCESS PIPELINE PENETRATING PRIMARY CONTAllNENT (Nueers in parentheses are keyed to numbers on following pages: signal codes are listed on following pages)

Power Location Power Closing Drywell Valve Type to Open Ref. to to Close Isolation Time Normal Remarks and Line Isolated Penetratten (6)

(5) (6)

Group Drywell (5) (6)

Signal (7)

Status Exceptions Core Spray Minimum Pump Flow X-210A,8 M0 Gate Ac B

Outside Ac RM Not applicable Closed C:re Spray to Reactor X-16A,8 M0 Gate Ac A

Outside Ac RM Not applicable Open Note (10)

Core Spray to Reactor X-16A,8 M0 Gate Ac A

Outside Ac RM Not applicable Closed Note (10)

Core Spray to Testable Check Reactor X-16A,B A0 Check (3)

A Inside Note (3)

Rev. flow Not applicable Closed Valve Note (3,16)

Core Spray Test to Suppression Pool X-210A.B M0 Globe Ac B

Outside Ac G,RM 45 Sec Closed Ctre Spray Puny Suction X-227A,B M0 Gate Ac 8

Outside Ac RM Not Applicable Open Drywell Equipment Drain Sue, Discharge X-19 M0 Plug Ac B

Inside Ac A,F,RM 30 Sec Open Drywell Equipment Drain Sump Discharge X-19 A0 Plug Afr/Ac B

Outside Spring A,F,RM Not Applicable Closed (17)

Drywell Floor Drain Susp Discharge X-18 M0 Plug Ac B

Inside Ac A.F.RM 30 Sec Open Drywell Floor Drain Sump Discharge X-18 AO Plug Air /Ac 8

Outside Spring A.F.RM Not Applicable Open Traveling Incore Explosive One valve Probe X-35A,B.C.D Shear De A

Outside Dc RM Not Applicable Open on each line One valve on 1

Trav211ng Incore each line Probe X-35A,B,C,D SO Ball Ac A

Outside Ac A.F.RM Not Applicable Open Note (14)

Traveling Incore Probe Purge X-358 S0 Valve Ac A

Outside Spring A F.RM Not Applicable Closed Traveling Incore Prot *;rge X-358 Check Fwd. Flow A

Inside Process Rev. Flow Not Applicable Closed WC1 - Turbine Steen Supply X-11 M0 Gate Ac A

Inside Ac L.RM 20 Sec Open 1 Signal "G" opens

) valve.

HPCI - Turbine 1 Signal "L" Steam Supply X-11 M0 Gate De A

Outside De L.RM 20 Sec Closed 1 overrides and h

  • 5' 5 '* l "-

Amendment No, g, g108 201

JAFNPP 4

Tel2 3.7-1 (Cont'd)

PROCESS PIPELIE PEETRATING PRINRRY CONTAIMENT (Numbers in perentheses are keyed to numbers on following pages: signal codes are Ifsted on following pages) rower LeCatten rower posfag Drywell Valve Type to Open Ref. to to Close Isolation Tfee Nonnel Resorts and Line Isolated Penetration (6)

(5) (6)

Group Drywell (5) (6)

Signal (7)

Status Exceptions

\\

D oses on Rev.

flow or low NPCI - Turhine Exhaust X-214 Check Fwd flow B

Outside Process Rev flow Not appifcable Open exhaust pressure MPCI - Turbine Enhaust X-214 Check Fwd flow B

Outside Process Rev. flow Not applicable Open i

NPCI - Puep Section X-226 M0 Gate Oc B

Outside Oc L.RM Not applicable Closed MPCI - Pump Section X-226 IS Gate Oc 5

Outside De L,150 Not appifcable Closed i

j MpCI - Puup Discharge X-g5 NO Gate Dc B

Outstde Dc M

Not appitcable Closed WCI - Turbine I.

Exhaust Drafn X-222 Stop Check Fud flow B

Outside Process Rev. flow Not appilcable Closed NPCI - Ninfaus 1

Pump Flow X-21 5 Check Fud flow B

Outside Process Rev. flow Not appifcable Closed l

MpCI - NInimum Pump Flow X-21 5 No Globe De B

Outstde De L.M 10 Soc Closed DETNELL ATIESpMERIC CONTROL AIS SERVICES Service Alr to Bryuell X-21 Check Process C

Inside Process Rev. flow Not appitcable Closed i

Service Air to Not app 1fcable Closed Drywell X-21 Hand Gate Hand C

Outside Hand Instrument Air to Dryuell X-22 Check Process C

Inside Process Rev. flow Not appifcable Open Fall in open Instrument Air to iDrywell X-22 30 Valve Spring C

Outside Ac M

Not applicele Open position to ensure adegoate pneumetfc supply Breathing Air to Drywell X-61 Check Process C

Inside Process Rev. flow Ilot applicable Closed Breathing Air to Not applicable Closed Dryuell X-61 Hand Gate IIend C

Outside Hand Dryuell Purge Inlet X-25, X-71 A0 Butterfly Atr/Ac B

Outside Spring F.A,7,RM S see Closed Dryuell Purge inlet X-25, X-71 A0 Butterfly Air /Ac 3

Outstde Spring F. A.Z,M S sec Closed ~

X-26A,3 A0 Butterfly Afr/Ac B

Outside Spring F.A,Z,WI 5 see Closed Amenement no.js(jd"g108 202

s'4 JAFIIPP

.s Tab 13 3.7-1 (Cont'd)

PROCESS PIPELINE PfKTRATIIIG PRIMARY CONTAIISEElli (Numbers in parentheses are keyed to numbers on following pages: signal codes are If sted on following pages)

Power 1ocation Power Closing Brywell Valve Type to Open lief, to to Close Isolation Tfee Monnel Remerts and Line Isolated Penetration (6)

(5) (6)

Group Dryuell (5) (6)

Signal (7)

Status Exceptions CAO Supply to

) Faf1 ia open Instrument Air to

) position to Drywell I-57c SO Valve Spring C

Outside Ac RM Hot appilcable Open

) ensure adequate

) pneumatic supply CAO Supply to Instrument Af r to Drywell I-57c Check Process C

Inside Fracess Rev. flow liot appifcable Closed Amendment No.gg 108

.