ML20205Q477

From kanterella
Jump to navigation Jump to search

Forwards Memo & Supporting Info Re Reexam of Basis for Licensing Facility in View of Accident at Chernobyl. Continued Operation Justified Until Scheduled Shutdown on 860531.Issue Will Be Reexamined Prior to Restart
ML20205Q477
Person / Time
Site: Fort Saint Vrain 
Issue date: 05/14/1986
From: Stello V
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To: Asselstine, Palladino, Roberts
NRC COMMISSION (OCM)
Shared Package
ML20205Q479 List:
References
TAC-60400, NUDOCS 8605280366
Download: ML20205Q477 (2)


Text

,

May 14, 1986 9 5f682(s Y 6

MEMORANDUM FOR: Chairman Palladino Commissioner Roberts Commissioner Asselstine Commissioner Bernthal Commissioner Zech FROM:

Victor Stello, Jr.

Executive Director for Operations

SUBJECT:

CONTINUED OPERATION OF THE FORT ST. VRAIN NUCLEAR GENERATING STATION The attached memorandum and supporting material are provided for your information. The staff has reexamined the NRC's basis for licensing the Fort St. Vrain gas-cooled reactor in view of-the Soviet RBMK-1000 reactor accident at Chernobyl. Based upon all the information available to us at this time, and our evaluation, the staff concludes that continued operation of Fort St. Vrain is justified until its scheduled shutdown on May 31, 1986. We will re-examine this issue prior to permitting restart, expected around September, 1986. Unless the Commission objects, I propose to make public these conclusions by May 21, 1986.

Original signed by Victor Stello Victor Stello, Jr.

Executive Director for Operations

Enclosure:

As stated cc: SECY OGC OPE POR A DISTRIBUTION:

LCentrabFile /DCSi PNoonan GCunningham, ELD SSPD Reading " -

KHeitner JTAYLOR, IE HBerkow DCrutchfield JFouchard, PA 0 Lynch JKnight RMartin, RIV EDO Reading Glainas TRehm VStello HDenton JRoe DEisenhut JSniezek FMiraglia FSchoeder

  • Revised in ED0; see prior concurrence sheet JHeltemes, AE0D NRR:DIR ED0 f HDenton VSte o 05/13/86*

05//

86 e

8605280366 860514 ADOCK0500g7 PDR P

j

MEMORANDUM FOR:

Chairman Palladino Commissioner Roberts Commissioner Asselstine Commissioner Bernthal Commissioner Zech FROM:

Victor Stello, Jr.

Executive Director for Operations

SUBJECT:

CONTINUED OPERATION OF THE FORT ST. VRAIN NUCLEAR GENERATING STATION x

/

Theattachedmemoran'dumandsupportingmaterieiareprovidedforyour

/

s information. The staff has reexamined the NRO's basis for licensing the

\\

/

Fort St. Vrain gas-cooled reactog in view of the Soviet RBMK-1000 reactor

,/

x accident at Chernobyl.

Based upon'all the information available to us at this

/N time, and our evaluation, the s.t&'ff concludes that continued operation of Fort St. Vrain is justified /and sees no ' reason to take any action regarding

\\

/

\\

such operation.

/

\\,

\\

\\

Victor Stello, Jr.

Executive Director s

for Operations

\\

Enclosure.

g As stated

\\

cc:

SECY OGC OPE DISTRIBUTION:

' Central File PNoonan SSPD~ Reading KHeitner HBerkow DCrutchfield 0 Lynch JKnight EDO Reading GLainas TRehm VStello HDenton DEisenhut FMiraglia FSchoeder JHeltemes, AE0D NRR: IR ED0 HDe on VStello 05/h/86 05/ /86