_ _ _ _ _ _ _ _ _ _ _ _ - - _ _
i ENCIDSURE 5 BRUNSWICK STEAM ELECTRIC PIANT, UNITS 1 AND 2 NRC DOCKETS 50 325 6 50-324 OPERATING LICENSES DPR 71 & DPR 62 REQUEST FOR LICENSE AMENDMENT OPERATIONAL CONDITION TABLE FOOTNOTE UNIT 1 TECHNICAL SPECIFICATION PAGES s
/
l 8811030466 881028 PDR ADOCK 05000324 P
i (BSEP-1-141).
TABLE 1.2 OPERATIONAL CONDITIONS se AVERACE OPERATIONAL MODE SWITCH REACTOR COOLANT CONDITIONS POSITIONS TEMPERATURE 1.
POWER OPERATION Run Any temperature 2.
STARTUP Startup/ Hot Standby Any temperature Shutdown '***
> 212'T d
3.
HOT SHUTDOWN 4.
COLD SHUTDOWN Shutdown #'E#'***
3 212'F 5.
REFUELINC*
Shutdown or Refuet**'#
$ 212'F 1
I i
f The reactor mode switch may.be placed in the Run or Startup/ Hot Standby position to test th's switch interlock functions provided that the control rods are verified to remain fully inserted by a second licensed operator or other technically qualified member of the unit technical staf f.
- The reactor mode switch may be placed in the Refuel position while a single control rod drive is being removed from the reactor pressure vesset per Specification 3.9.10.1.
- Fuel in the reactor vessel with the vessel head closure bolts less than fully tensioned or with the head removed.
- See Special Test Exceptions 3.10.1 and 3.10.1.
- The reactor mode switch may be placed in the Refuel position while a single control rod is being moved provided that the one-rod-out interlock l
is OPERABLE.
BRUNSWICK - UNIT 1 1-10 Amendment No.
- e ENC 14SURE 6 BRUNSWICK STEAM ELECTRIC PIANT, UNITS 1 AND 2 NRC DOCKETS 50 325 6 50 324 OPERATINC LICENSES DPR 71 & DPR 62 REQUEST FOR LICENSE AMENDMENT OPERATIONAL CONDITION TABLE FOOTNOTE UNIT 2 TEC11NICAL SPECIFICATION PAGES
(BSEP-2-143)
TABLE 1.2 OPERATIONAL CONDITIONS bl AVERAGE OPERATIONAL MODE SWITCH REACTOR COOLANT CONDITIONS PO9ITIONS TEMPERATURE 1.
POWER OPERATION Run Any temperature 2.
STARTUP Startup/ Hot Standby Any temperature 3.
HOT SHUTDOWN Shutdown #'***
> 212*F 4.
COLD SHUTDOWN Shutdown #'E0'***
$ 212'F 5.
REFUELINC*
Shutdown or Refuel **'I
$ 212*F
- The reactor mode switch may be placed in the Run or Startup/ Hot Standby position to test the switch interlocit functions provided that the control rods are verified to remain fully inserted by a.econd licensed operator or other technically qualified member at the unit technical staff.
- The reactor mode switch may be placed in the Refuel position while a single control rod drive is being removed from the reactor pressure vessel per Specification 3.9.10.1.
- Fuel in the reactor vessel with the vessel head closure bolts less than fully tensioned or with the head removed.
See Special Test Exceptions 3.10.1 and 3.10.3.
The reactor mode switch may be placed in the Refuct position while a single control rad is being moved provided that the one-rod-out interlock l
is OPERABLE.
BRUNSWICX - UNIT 2 1-11 Amendment No.