t VIHOINIA 1$LI (*THIC AND l' owl:H Cubtl'ANY I{ ICIIMONID, VIINIINI A UllMfit March 30, 1987 w,,,, 3,,,,,,

Y,d'R l'E P BDRWT NeaLatan Dramareenne U. S. Nuclear Regulatory Commission Serial No.

87 055A Attn: Document Control Desk N0/FPB Washington, D. C.

20555 Docket No.

50 281 License No. DPR-37 1

Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 2 SUPPLEMENTAL INSERVICE INSPECTION REPORT i

As stated in our letter dated March 2, 1987, enclosed is the Supplemental Inservico Inspection Report for Surry Power Station Unit 2.

This report is an Examination Summary. Should you require more detailed information, the entire report will be maintained on file at the station and the corporate office.

In accordance with ASME Section XI, IWA-6220, Reports for Class 1 and I

Class 2 Components, a Form NIS-1, Owner's Report for Inservice Inspections, is provided with this report.

l Very truly yours.

V' C

i n W. L. Stewart Enclosures cc:

U. S. Nuclear Regulatory Commission Region II 101 Mariotta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station b

N 0704010473 (17033o h

{'UH ADOCK 05000201 g}k PDR

\\