ML20205D268

From kanterella
Jump to navigation Jump to search
Rev 18 to Offsite Dose Calculation Manual
ML20205D268
Person / Time
Site: San Onofre  
Issue date: 03/19/1986
From:
SOUTHERN CALIFORNIA EDISON CO.
To:
Shared Package
ML20205D247 List:
References
3081C, PROC-860319, NUDOCS 8608150318
Download: ML20205D268 (63)


Text

{{#Wiki_filter:_ _ _ _ OFFSITE DOSE CALCULATION MANUAL NUCLEAR GENERATION SITE UNITS 2 AND 3 ( a 9608150318 860612 PDR ADOCK 05000361 R PDR APPROVED r MAR 171986 Revision 18 03-19-86

Units 2/3 ODCM Changes in Revision 18 This explanation section for the 00CM changes contain sufficiently detailed information to support the rationale for the changes without benefit of additional or supplemental information. Revision 18 to the Units 2/3 00CM was adopted in order to update the dose parameter tables (pages 2-28 through 2-60), to reflect the latest Land Use Census. In addition, Section 2.4 has been changed in its entirety to reflect a more definitive calculation of 40 CFR 190 dose limitations. Monitor 3RT-7804 has been supplanted by 3RT-7828 for the purpose of containment purge monitoring. Flow rates for containment purge have been revised upwards to maximum expected values based on RT-7828 flow measurements. The changes in this revision to the ODCM do not reduce the accuracy or reliability of the dose calculations or setpoint determinations. This revision was revierd and found acceptable pursuant to Technical Specification 6.5.2.9 on March 17, 1986, and became effective on March 19, 1986. The changes are detailed below. 1. Table of Contents page nos. corrected (pages i,11) 2. List of Tables page nos, corrected (pages tv, v) 3. Table 1-1, page 1-18 updates calibration values for Cs-137 4. Pages 2-8, 2-9, 2-10 and 2-11 a. Deleted: References to monitor 3RT-7804 b. Changed: Flowrates for containment purge in cfm and cc/sec c. Added: References to monitor 3RT-7828 5. Table 2-1 page 2-15 a. Deleted: References to monitor 3RT-7804 b. Changed: Updates calibration values for Xe-133. _..

Units 2/3 ODCM Changes in Revision 18 (Continued) 6. Table 2-4, page 2-27, " Controlling Location Factors" The values in Table 2-4, " Controlling Location Factors," are the a. maximum values for each nuclide of the product of X/Q (Inhalation Pathway) or D/Q (Food and Ground Pathway) and the value of R in g Tables 2-5 through 2-14. b. Changed: Maximal values for: H-3, Mn-54, Co-57, Co-58, Co-60, Zr-95, Nb-95, Te-129m, Cs-136, I-133, I-135, UN-ID. 7. Table 2-5 through 2-14, pages 2-28 through 2-60, " Dose Parameters R " g The values in Tables 2-5 through 2-14 are obtained using the " PARTS" a. code based upon the input data given in Table 2-15 which is appropriate to the 1985 Land Use Census occupancy data. The listings for Table 2-5 through 2-14 giving the receptor distance, sector, X/Q and D/Q information is obtained from the "X0QD0Q" code. This code uses data from the 1979-1983 Dames & Moore report on site-specific wind frequencies, continuous release considerations and terrain recirculation factors. The actual distance to the receptor in each sector is used. i The new tables and new values throughout the R tables including 4 distances, X/Q and D/Q values are a result of reassessments made by the 1985 Land Use Census, b. Table 2-5, page 2-32, includes a new location; " Trestles Beach Tower." Table 2-6, pages 2-34 and 2-39, includes two new locations; " Surf c. Beach Guard Shack" and "S.C. Res. W-Garden," respectively, d. Table 2-7, page 2-43, includes a new location, "S.C. Ranch Parking." Table 2-9, page 2-47, includes a new location, " Sanitary Landfill." e. f. Table 2-10, pages 2-50 and 2-51, includes two new locations, " Camp San Onofre Fr. Stn." and " Sewage Facility," respectively. g. Table 2-14, page 2-60, includes a new location, " Hwy. Patrol Weigh Station." Units 2/3 ODCM Changes in Revision 18 (Continued) 8. Table 2-15, pages 2-61 through 2-69 includes all parameter changes made in the " PARTS" code as a result of the 1985 Land Use Census. 9. Section 2.4, page 2-70, the " Total Dose to the Most Likely Member of the Public", has been revised. A more precise calculation of total dose consists of five equations which are: I Equation (2-20), page 2-70, determines the annual total organ dose a. for all units, all pathways, over the most recent twelve months. This equation uses equation (2-21) below to calculate maximum gaseous organ dose, b. Equation (2-21), page 2-70, determines maximum gaseous pathway organ dose. This equation selects the most restrictive age group / pathway by using Table 2-4, the " Controlling Location Factors". This table lists the highest gas dose attributable to each isotope of all combinations of age group, pathways and sector, Equation (2-22), page 2-71, determines the annual total whole body c. dose for all units, all pathways, over the most recent twelve months. This equation calculates maximum whole body gaseous dose by incorporating equation (2-21) above. d. Equation (2-23), page 2-71, is the direct dose component of caustion (2-22) above. This replaces the former equation (2-22). Equation (2-24), page 2-72, determines the annual total thyroid dose e. for all units, all pathways, over the most recent twelve months. This equation determines maximum gaseous thyroid dose by incorporating equation (2-21) above.

10. Table 5-1, Page 5-5, " Airborne Sampling" a.

Added: 9 State Beach Park ** 10 Bluff 11 Mesa EOF 12 SONGS Evaporation Pond b. Deleted: 4 Northeast Site Boundary c. Changed: 1 City of San Clemente (City Hall) 2 Camp San Onofre (Camp Pendleton) 5 Units 2 and 3 Switchyard ** 6 SONGS Meterological Tower ** Not required by Technical Specifications.

Units 2/3 ODCM Changes in Revision 18 (Continued)

11. Table 5-2, page 5-8, includes all changes made in pressurized ion chamber names, distances and compass directions. Angles relative to true north and distance to the ion chambers in meters, have been added.

a. Changed: Distances for ton chambers S1 through 59 inclusive, have increased. The name for S2 has changed to " SONGS Evaporation Pond" from "El Camino Training Annex" Directions for ion chamber S1 has changed to WNW from W. b. Added: Angles for Si through S9 inclusive, have been added. Distance measurements in meters for 51 through 59 have been added. i I 2025j 1 ODCM TABLE OF CONTENTS ( Pagg LIST OF FIGURES....................................................... iii LIST OF TABLES..........................................".............. iv-v INTRODUCTION......................................................... vi 1.0 LIQUID EFFLUENTS 1.1 Liquid Ef fluent Monitor Setpoints......................... 1-1 1.1.1 Batch Release Setpoint Determination.............. 1-3 1.1.2 Continuous Release Setpoint Determination......... 1-9 1.2 Dose Calculations for Liquid Effluents.................... 1-19 1.3 Rep re s en ta ti ve Sampl i ng.................................... 1-22 2.0 GASEOUS EFFLUENTS 2.1 Ga seous Ef fluent Monitor Setpoints........................ 2-1 l-2.1.1 Plant Stack....................................... 2-1 2.1.2 Conden ser Evacua tion System.............. 2.1.3 Containment Purge................................ 2-5 ......... 2-0 2.2 Ga seous Ef fl uen t Do se Ra te................................ 2-16 2.2.1 Noble Gases....................................... 2-16 2.2.2 Radiciodines and Particulates..................... 2-17 2.3 Ga seous Ef fluent Dose Calculation......................... 2-19 2.3.1 Noble Gases....................................... 2-19 2.3.1.1 Historical Meteorology.................. 2-19 2.3.1.2 Concurren t Me teo ro logy.................. 2-20 2.3.2 Radiciodines and Particulates..................... 2-21 2.3.2.1 Hi storical Meteorology.................. 2-21 2.3.2.2 Concurrent Meteorology.................. 2-23 2.4 Total Dose Calculations................................... 2-67 2.4.1 Total Dose to Most Likely Member of the Pu Thyroid Dose.............................blic .... 2-70 2.4.2 ......... 2-72 l APPROVED MAR 171986 g,yision is 1 03-19-86

p ODCM TABLE OF CONTENTS (Continued) Pagg 3.0 PROJECTED DOSES 3.1 Liquid Dose Projection......................... Gaseous Dose Projection................................... 3-1 3.2 ........... 3-1 4.0 OPERABILITY OF EQUIPMENT........................................ 4-1 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING........................... 5-1 ( APPROVED MAR 171986 11 Rev. 18 03-19-86

b ODCM LIST OF TABLES ( i Table Title Page 1-1 Liquid Effluent Radiation Monitors Ca l i b ra t i o n Co n s t a n t s..................................... 1-18 l 1-2 Dose Commitment Factors Air............................... 1-20 2-1 Gaseous Effluent Radiation Monitors i Calibration Constants..................................... 2-15 i 2-2 Dose Factors for Noble Gas and Daughters.................. 2-25 2-3 Dose Parameters P ik....................................... 2-26 l 2-4 Control li ng Loca tion Factors.............................. 2-27 2-5 Dose Pa rameters R, for Sector P............................ 2-28 thru 2-32 2-6 Dose Parameters R, for Sector Q............................ 2-33 thru 2-39 2-7 Dose Parameters R g fo r Sector R............................ 2-40 th ru ( 2-43 l 2-8 Dose Parameters R f or Secto r A............................ 2-44 thru 9 2-45 2-9 Dose Parameters R fo r S ec to r B............................ 2-4 6 th ru g 2-47 2-10 Dose Parameters R for Sector C............................ 2-48 thru I 2-51 2-11 Dose Parameters R for Sec tor D............................ 2-52 thru l I 2-53 2-12 Dose Parameters R fo r S ec to r E............................ 2-54 th ru l y 2-55 2-13 Dose Parameters R, for Sector F............................ 2-56 thru 2-57 2-14 Dose Parameters R for Sector G............................ 2-58 thru y 1 2-60 ( APPROVED l l iv NAR 171986 Rev. 18 03-19-86 L

ODCM LIST OF TABLES (Continued)) ( Table Title Page 2-15 Parameters Used to Calculate RI........................... 2-61 thru 2-69 5-1 Radiological Environmental Monitoring Sample Locations.... 5-2 thru 5-7 5-2 Radiological Environmental Monitoring Locations........... 5-8 5-3 Sector and Direction Designation for Radiological Environmental Monitoring Sample Location Map.............. 5-9 ( ) APPROVED. MAR 171986 y Rev. 18 03-19-86

Table 1-1 *I I (. Liquid Effluent Radiation Monitor Calibration Constants MONITOR Co-60* Ba-133* Cs-137* 2RT-6753 1.86E-8 2.11E-8 2RT-6759 1.79E-8 1.92E-8 3RT-6753 1.72E-8 1.90E-8 3RT-6759 1.74E-8 1.92E-8 2/3RT-7813 1.79E-9 3.58E-9 4.55E-9 2RT-7817 2.10E-9 3.19E-9 4.75E-9 2RT-7821 2.08E-9 3.17E-9 4.70E-9 3aT-7817 2.24E-9 2.99E-9 5.18E-9 3RT-7821 2.15E-9 3.30E-9 4.83E-9 )

  • (pC1/cc/ cpm)

(*) This table provides typical (i20%) calibration constants for the liquid ef fluent radiation monitors. APPROVED MAR 171986 1-18 Rev. 18 03-19-86

2.1.3 CONTAINMENT PURGE - 2RT-7828, 3RT-7828 2RT-7865. 3RT-7865 ( For the purpose of implementation of Specification 3.11.2.1, the alarm setpoint level for noble gas monitors is based on the gaseous effluent flow rate and the meteorological dispersion factor. The concentration at the detector corresponding to a total body dose rate of 500 mrem /yr at the exclusion bouncary is determined by using: (0.45)(P)(2120,,C((c ) ( 500 mrem /yr) (10 Ci/pci) C 2 det2 =(Flow rate, cfm) (X/Q, sec/m3)'[I (K, mre (2-6) g g 1 pC1/m3 ,g (0.45)(P )(2120,, ) ( 500 mrem /yr) (10 Ci/pCf) C 3 c det3 =(Flow rate, cfm) (X/Q, sec/m )[I (K, mrem (2-7) 3 g 9 i pC1/m3 gg 3 The concentration at the detector corresponding to a 3000 mrem /yr skin dose rate at the exclusion area boundary is determined by us,ing: (0.45)(P)(2120,ij((c ) (3000 mrem /yr) (10 C1/pci) C 2 det2 =(Flow rate, cfm)7X70, sec/m )[I(L (2-6a) 3 g + 1.1M, mrem /yr)( Q,g )] C_ g g i pCi/m (0.45)(P)(2120,,j,I[c ) (3000 mrem /yr) (10 C1/ pct) C 3 det3 =(Flow rate, cfm) (X/Q, sec/m3T[I(L (2-7a) g + 1.1M, mrem /yr)( {C, )] g g i pC1/m8 og APPROVED MAR 171986 2-8 Rev. 18 03-19-86

r-, 2.1.3 CONTAINMENT PURGE - 2RT-7828, 3RT-7828 HF7865, 3RT-7865 (Continued) ( where: Cdet2 = The instantaneous concentration of the Unit 2 detector in pCf/cc. Cdet3 = The instantaneous concentration of the Unit 3 detector in pCi/cc. 0.45 is an administrative values used to account for potential activity from other gaseous release pathways. P and P are administrative values used to account for 2 3 simultaneous purges of both SONGS 2 and SONGS 3. The fractions P and P3 will be assigned such that 2 P2+P3 $ 1.0. ( Flow rate = the observed maximum flowrate in cfm from the ) unit specific monitor 7828. Default values will be the following conservative measured flows: = 50,000 cfm full purge 3,000 cfm mini purge = the above valuer replace the smaller design flowrates. Other parameters are as specified in 2.1.1.1 above. The smaller of the values of maximum permissible O I'

  • det2 equation (2-6) or (2-6a) and C fr m equati ns (2-7) det3 or (2-7a) is to be used in determining the maximum permissible monitor alarm setpoints.

APPROVED MAR 171986 2-9 Rev. 18 03-19-36 t

2.1.3 CONTAINMENT PURGE - 2RT-7828, 3RT-7828, 2RT-7865, 3RT-7865 (Continued) 2.1.3.1 Maximum permissible Alarm Setting (RT-7865) The maximum permissible alarm setting for the Wide Range Gas Monitor expressed as a maximum release rate (pCi/sec) is determined by converting the concentration at the detector, Cd't (pCi/cc),to an equivalent release rate in pCi/sec. A,,x = (Cdet, u 1/cc) (flow rate, cc/sec) Where: A,,, = the maximum permissible release rate C = the. smaller value of Cdet, as obtained from det equation (i-6, 2-6a) for Unit 2 or (2-7, 2-7a) for Unit 3. flow rate = flow rate, cc/sec ( = either 1.416E6 cc/sec for mini purge or y 2.360E7 cc/sec for main purge. .2 Maximum Permissible Alarm Setting (2RT-7828) The maximum permissible alarm setting for 2RT-7828 is in pCi/cc and is the smaller of the values of Cdet2(uC1/cc) from equations (2-6) and (2-6a). If there is no release associated with this monitor, the monitor setpoint should be established as close as practical to background to prevent spurious alarms yet assure an alarm should an inadvertent release occur. APPROUED MAR 171996 2-10 Rev. 18 03-19-86

2.1.4 WASTE GAS HEADER 7865, 2/3RT-7808 For the purpose of Specification 3.11.2.1, the alarm setpoint ( level for noble gas monitors is based on the gaseous effluent flow rate and the meteorological dispersion factor. Since the waste gas header discharges to the plant vent stack, either 3RT-7865 or 2/3RT-7808 may be used to monitor waste gas header releases. The concentration at che detector corresponding to a total body dose rate of 500 mrem /yr or a skin dose rate of 3000 mrem /yr at the exclusion area boundary is determined by using equations (2-1) or (2-2) with sample concentration (C ) and (Cgog) being obtained j from the waste gas decay tank to be releas<ad. The smaller of the values of maximum permissible concentration (Cdet) from equation (2-1) or (2-2) is to be used in de'ermining the maximum permissible monitor alarm setpoint. 2/3RT-7808 The maximom permissible alarm setting (cpm) is determined by using the calibration ' constant for plant vent stack monitor 7808 given in Tabic 2-1. The maximum permissible setpoint is the cpm value corresponding to the concentra-tion Cdet, (smaller value from equation (2-1) or (2-2)). I APPROVED MAR 171966 2-11 Rev. 18 03-19-86

p I Tablo 2-I *) l Gaseous Effluent Radiation Monitor ( Calibration Constants l s MONITOR Kr-85* Xe-133* 2/3RT-7808C 2.9LE-8 4.33E-8 2RT-/818A 3.67E-8 5.12E-8 l 2RT-78188 6.30E-5 6.30E-5 3RT-7818A 3.88E-8 4.40E-8 l 3RT-78188 6.49E-5 6.10E-5 s ( ) l so

  • l l

l

  • (uCi/cc/ cpm)

(*)This table provides typical (220%) calibration constants for the i gaseous effluent radiation monitors, c APPROVED NAR 171986 l 2-15 Rev. 18 03-19-86

TABLE 2-4 I CONTROLLING LOCATION FACTORS l IR W l gk k l Radionuclide mrem /yr per pCi/sec l l l L I H -3 8.06E-4 l Cr-51 1 1.68E-2 l l i Mn-54 1 3.24E0 l l Co-57 8.02E-1 l l Co-58 9.38E-1 l l Co-60 l 4.95El l l Sr-89 l 4.90E1 l l Sr-90 l 1.96E3 l Zr-95 1.68E0 iC l Nb-95 6.58E-1 l Te-129m 4.06E0 l l Cs-134 3.64E1 l Cs-136 4.66E-1 i l Cs-137 l 3.36El I Ba-140 l 3.92E-1 l Ce-141 l 7.42E-1 Ce-144 1.82E1 l ( I -131 6.72E1 l I -133 2.36E0 l 2 I -135 4.96E-1 l UN-ID 3.78E0 1 1 g I I I l l l l l 1 I I I l l l l l 1 1 1 1 I I I I I l' I I ( Footnote: These values to be used in manual calculations are the maximum IR W for all locations based on the most restrictive age group. gA k APPROVED 2-27 Rev. 18 MAR 171936 g3 19 86

TABLE 2-5 ( DOSE PARAMETER R FOR SECTOR P g Page 1 of 5 Pathway = Surf Beach Distance = 0.4 miles l X/Q = 1.8E-6 sec/m* D/Q = 8.2E-9 m 8 l I l Infant l Child l Teen l Adult l lInhala-l Food & Inhala-l Food & Inhala-l Food &lInhala-l Food Radio-l tion l Ground l tion l Ground l tion l Ground l tion l Ground i Nuclide l Pathway l Pathway l Pathway l PathwaylPathway l PathwaylPathway l Pathway l l l l l l l H -3 1 0.0E0 l 0.0E0 l 1.2E1 1 0.0E0 l 5.1El 1 0.0E0 l 1.8E2. l 1 0.0E0 l Cr-51 ' O.0E0 1 0.0E0 l 1.1El l 2.2E4 l 1.2E2 l 1.1ES l 4.7E2 I 6.6ES l Mn-54 0.0E0 0.0E0 l 4.5E2 l 6.6E6 1 2.7E3 1 3.2E7 l 1.1E4 l 2.0E8 i Co-57 0.0E0 0.0E0 1.4E2 ! 1.6E6 1.3E3 1 7.9E6 1 4.5E3 4.9E7 l Co-58 0.0E0 l 0.0E0 3.6E2 1.8E6 3.8E3 l 8.7E6 l 1.5E4 5.4E7 l 1 Co-60 0.0E0 1 0.0E0 1.0E3 1.0E8 1.0E4 1 4.9E8 l 4.1E4 3.1E9 i i Sr-89 0.0E0 0.0E0 6.2E3 l 1.0E2 l 1.8E4 l 4.9E2 l 4.3E4 3.1E3 l Sr-90 0.0E0 H 0.0E0 1.1E6 l 0.0E0 l 4.4E6 l 0.0E0 l 1.4E7 l 0.0E0 l Zr-95 l 0.0E0 0.0E0 6.3E2 l 1.2E6 l 6.0E3 l 5.8E6 [ 2.1E4 l 3.6E7 i Nb-05 l 0.0E0 0.0E0 3.8E2 J 6.6E5 l 3.9E3 1 3.1E6 1.5E4 l 1.9E7 l Te-129m l 0.0E0 0.0E0 5.2E2 9.4E4 l 2.1E3 4.5E5 i 5.2E3 l 2.8E6 i Cs-134 ' O.0E0 0.0E0 1.1E4 3.3E7 l 4.5E4 1.6E8 l 1.2E5 l 9.7E8 l ( Cs-136 0.0E0 l 0.0E0 1 1.8E3 7.2E5 l 7.8E3 3.4E6 1 2.1E4 l 2.1E7 1 Cs-137 0.0E0 l 0.0E0 8.6E3 1 4.9E7 l 3.4E4 1 2.4E8 l 8.9E4 1.5E9 l Ba-140 0.0E0 0.0E0 7.7E2 1 9.9E4 9.2E3 1 4.7ES I 3.1E4 2.9E6 I q Ce-141 0.0E0 0.0E0 5.9E2 6.6E4 5.1E3 1 3.1E5 1.7E4 l 1.9E6 l Ce-144 0.0E0 0.0E0 l 4.0E3 3.3E5 3.5E4 l 1.6E6 1.2E5 l 9.9E6 l I -131 1 0.0E0 0.0E0 l 1.7ES 8.3E4 5.9ES l 3.9E5 l 1.7E6 l 2.5E6 l I -133 0.0E0 0.0E0 l 4.0E4 1.2E4 1.2E5 l 5.6E4 l 3.1E5 l 3.5ES l I -135 0.0E0 0.0E0 ' 8.2E3 1.2E4 ? 2.5E4 l 5.8E4 l 6.4E4 l 3.6ES l UN-10 0.0E0 0.0E0 1.2E3 3.6E6 l.5.4E3 l 1.7E7 l 1.5E4 l 1.1E8 l l l 1 l l 1 l l l i l l i I l l l 1 I l l l 1 l l l l l l l l 1 l l l I I l L l l l I I I l il l l l l l I' I l l l 1 l 1 1 I I I I I L I Inhalation Pathway, units = AlfyMU V A D' i Food & Ground Pathway, units = f,"#Y"I MAR.171986 2-28 Rev. 18 03-19-86

t TABLE 2-5 ( DOSE PARAMETER R FOR SECTOR P g Page 2 of 5 Pathway = Enlisted Beach Distance = 1.2 miles l X/Q = 3.8E-7 sec/m' D/0 = 1.4E-9 m 8 l Infant l Child Teen Adult 'Inhala-Food & IInhala-Food & lInhala-Food &l Inhala-l Food & l JRadio- , tion Ground Ltion l Ground l tion Ground ltion l Ground I Nuclide l Pathway l Pathway Pathway l Pathway l Pathway Pathway l Pathway l Pathway i i I i i l H -3 ' O.0E0 1 0.0E0 l 1.2EI 0.0E0 l 5.1El l 0.0E0 l 1.6El 0.0E0 Cr-51 0.0E0 l 0.0E0 ' 1.1El 2.2E4 l 1.2E2 l 1.1E5 ' 4.1El 1 1.9E4 Mn-54 0.0E0 0.0E0 4.5E2 ,1 6.6E6 l 2.7E3 l 3.2E7 9.5E2 [ 5.7E6 Co-57 0.0E0 0.0E0 1.4E2 1 1.6E6 l 1.3E3 l 7.9E6 1 3.9E2 1.4E6 Co-58 0.0E0 0.0E0 3.6E2 1.8E6 3.8E3 ll 8.7E6 l 1.3E3 1.6E6 Co-60 ' O.0E0 0.0E0 , 1.0E3 1.0E8 .l 1.0E4 4.9E8 l 3.5E3 8.8E7 Sr-89 0.0E0 0.0E0 6.2E3 1.0E2 l 1.8E4 4.9E2 1 3.7E3 l 8 9El Sr-90 0.0E0 0.0E0 1.1E6 0.0E0 ' 4.4E6 0.0E0 1.2E6 0.0E0 l l Zr-95 O.0E0 0.0E0 6.3E2 ' 1.2E6 6.0E3 5.8E6 1.8E3 1.0E6 Nb-95 0.0E0 0.0E0 3.8E2 6.6ES 3.9E3 3.1E6 i 1.3E3 5.6ES i Te-129m 0.0E0 0.0E0 5.2E2 9.4E4 2.1E3 4.5E5 l 4.5E2 8.1E4 Cs-134 0.0E0 l 0.0E0 1.1E4 3.3E7 4.5E4 1.6E8 l 1.0E4 2.8E7 Cs-136 0.0E0 l 0.0E0 1.6E3 7.2E5 7.8E3 3.4E6 1.8E3 6.2E5 ( Cs-137 1 0.0E0 l 0.0E0 8.6E3 4.9E7 3.4E4 2.4E8 7.6E3 4.2E7 1 Ba-140 l 0.0E0 0.0E0 7.7E2 9.9E4 1 9.2E3 4.7ES 2.7E3 8.4E4 L I Ce-141 0.0E0 0.0E0 5.9E2 1 6.6E4 5.1E3. 3.1E5 1.5E3 5.6E4 l l Ce-144 0.0E0 ' O.0E0 4.0E3 3.3E5 3.5E4 l 1.6E6 1.0E4 2.9ES l l 1 -131 0.0E0 ' O.0E0 1.7E5 8.3E4 5.9ES ' 3.9ES 1.5ES 7.1E4 l 1 -133 0.0E0 0.0E0 D 4.0E4 1.2E4 1.2E5 5.6E4 2.6E4 1.0E4 I -135 0.0E0 0.0E0 8.2E3 1.2E4 2.5E4 ' 5.8E4 5.5E3 1.0E4 UN-!D 0.0E0 0.0E0 1.2E3 3.6E6 ,5.4E3 1.7E7 1.3E3 l 3.1E6 1 1 1 l l l l l 1 Inhalation Pathway, units = Food & Ground Pathway, units a hj"c APPROVED 2-29 MAN f 7 I R Rev. 18 03-19-86

TABLE 2-5 ( DOSE PARAMETER R; FOR SECTOR P Page 3 of 5 l Pathway =EnlistedBeachCampgroundCheck-In Distance = 1.5 miles l l X/Q = 3.0E-7 sec/m' 0/Q = 1.1E-9 m 2 l l Infant l Child Teen l Adult l l l l l i l lInhala-l Food & lInhala-l Food & lInhala-l Food & lInhala-Food & 1 i l Radio-l tion l Ground ltion l Ground l tion l Ground l tion l Ground l lNuclide ! Pathway lPathwaylPathwayl Pathway l Pathway l Pathway l Pathway l Pathway l l l l l l 1 l l l l l H -3 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 2.9E2 l 0.0E0 i Cr-51 l 0.0E0 ' O.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 7.6E2 l 1.1E6 i Mn-54 1 0.0E0. 0.0E0 l 0.0E0 0.0E0 1 0.0E0 1 0.0E0 1.8E4 1 3.2E8 i L Co-57

0.0E0 [ 0.0E0 l 0.0E0 0.0E0 l 0.0E0 1 0.0E0 il 7.2E3 l 7.8E7 l

l Co-58 l 0.0E0 ' O.0E0 l 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 2.4E4 l 8.7E7 l l Co-60 0.0E0. 0.0E0 1 0.0E0 0.0E0.1 0.0E0 1 0.0E0 l 6.5E4 l 4.9E9 l l Sr-89 0.0E0 l 0.0E0 1 0.0E0 0.0E0 l 0.0E0 1 0.0E0 l 6.9E4 l 4 9E3 l Sr-90 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 0.0E0 2.3E7 l 0.0E0 Zr-95 0.0E0 l O.0E0 l 0.0E0 0.0E0 0.0E0 1 0.0E0 3.4E4 l 5.7E7 I Nb-95 0.0E0 0.0E0 1 0.0E0 0.0E0 0.0E0 0.0E0 l 2.4E4 I 3.1E7 i Te-129m l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 0.0E0 8.3E3 1 4.5E6 i Cs-134 l 0.0E0 0.0E0 l 0.0E0 0.0E0 l 0.0E0 0.0E0 1.9ES 1.6E9 l l Cs-136 0.0E0 l 0.0E0 0.0E0 ( l Cs-137 0.0E0 1 0.0E0 0.0E0 0.0E0 l 0.0E0 l 0.0E0 3.3E4 3.4E7 l l 0.0E0 l 0.0E0 1 0.0E0 1.4E5 1 2.3E9 l l Ba-140 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 0.0E0 5.0E4 l 4.7E6 l l Ce-141 0.0E0 t 0.0E0 1 0.0E0 0.0E0 0.0E0 0.0E0 l 2.7E4 1 3.1E6 l l Ce-144 0.0E0 0.0E0 l 0.0E0 0.0E0 0.0E0 l 0.0E0 1.9E5 l 1.6E7 l l I -131 0.0E0 0.0E0 l 0.0E0 0.0E0 0.0E0 ; 0.0E0 2.7E6 1 3.9E6 l l I -133 0.0E0 0.0E0 l 0.0E0 0.0E0 0.0E0 l 0.0E0 4.9ES I 5.6E5 l l I -135 0.0E0 1 0.0E0 1 0.0E0 ' O.0E0 0.0E0 ! 0.0E0 1.0E5 5.8E5 UN-ID 0.0E0 l' O.0E0 l 0.0E0 0.0E0 0.0E0 0.0E0 2.4E4 1.7E8 t l 1 r i I I I i 1 I I H l l 1 L I l l l l l l l l l l l I l l l I I I I I i 1 I I l l I I l l l l l l I l l 1 l l l t i I I I l i I I I I I I l l 1 I I I I I I I l I Inhalation Pathway, units =

  • E Food & Ground Pathway, units =

A P P R()V E D t1AR 171986 2-30 Rev. 18 03-19-86

TABLE 2-5 ( DOSE PARAMETER R FOR SECTOR P g Page 4 of 5 l Pathway =FormerNixonEstate(nogarden) Distance = 2.8 miles l X/0 = 1.2E-7 sec/m' 0/Q = 3.4E-10 m 8 l l Infant i Child l Teen Adult lInhala-l Food & Inhala-l Food & IInhala-l Food & i nhala-Food &l. I 1 l Radio-l tion i Ground ition l Ground ltion l Ground ition Ground l lNuclide IPathway i PathwaylPathway l PathwaylPathway l Pathway l Pathway l Pathway,' l l l l f I l ,i H -3 1 6.5E2 l 0.0E0 l 1.1E3 1 0.0E0 l 1.3E3 1 0.0E0 l 1.3E3 1 0.0E0 1 l Cr-51 l 3.6E2 1 3.7E6 l 1.1E3 l 3.7E6 l 3.0E3 1 3.7E6 1 3.3E3 1 3.7E6 Mn-54 l 2.5E4 l 1.1E9 l 4.3E4 l 1.1E9 I 6.7E4 l 1.1E9 1 7.7E4 1 1.1E9 Co-57 ' 4.9E3 1 2.7E8 ! 1.3E4 1 2.7E8 l 3.1E4 l 2.7E8 l 3.1E4 l 2.7E8 l Co-58 l 1.1E4 1 3.0E8 l 3.4E4 1 3.0E8 l 9.5E4 1 3.0E8 l 1.1ES I 3.0E8 I Co-60 3.2E4 l 1.7E10 l 9.6E4 1.7E10 J 2.6ES l 1.7E10 2.8E5 l 1.7E10 l Sr-89 4.0E5 l 1.7E4 1 6.0E5 ' 1.7E4 l 4.3E5 l 1.7E4 3.0E5 l 1 7E4 l l Sr-90 1 4.1E7 l 0.0E0 1 1.0E8 1 0.0E0 1.1E8 l 0.0E0 l 9.9E7 l 0.0E0 l Zr-95 l 2.2E4 l 2.0E8 I 6.1E4 l 2.0E8 1.5ES i 2.0E8 l 1.5E5 l 2.0E8 l Nb-95 l 1.3E4 1 1.1E8 i 3.7E4 l 1.1E8 9.7E4 l 1.1E8 1.0E5 l 1.1E8 Te-129m l 3.2E4 l 1.6E7 I 5.0E4 l 1.6E7 I 5.2E4 l 1.6E7 3.7E4 l 1.6E7 Cs-134 I 7.0E5 1 5.5E9 1 1.0E6 l 5.5E9 l 1.1E6 1 5.5E9 8.5E5 1 5.5E9 Cs-136 l 1.3E5 l 1.2E8 l 1.7E5 l 1.2E8 1.9ES l 1.2E8 l 1.5E5 l 1.2E8 ( Cs-137 1 6.1E5 l 8.2E9 l 8.3E5 l 8.2E9 8.5E5 l 8.2E9 I 6.2E5 l 8.2E9 Ba-140 5.6E4 l 1.6E7 1 7.4E4 l 1.6E7 ' 2.3E5 i 1.6E7 l 2.2E5 l 1.6E7 i Ce-141 2.2E4 l 1.1E7 1 5.7E4 1 1.1E7 1.3E5 l 1.1E7 l 1.2E5 l 1.1E7 l Ce-144 L 1.5E5 l 5.6E7 l 3.9E5 1 5.6E7 l 8.6E5 5.6E7 8.2E5 l 5.6E7 I I -131 1 1.5E7 1.4E7 l 1.6E7 ' 1.4E7 l 1.5E7 ' 1.4E7 1.2E7 l 1.4E7 I -133 1 3.6E6 2.0E6 l 3.8E6 2.0E6 l 2.9E6 2.0E6 J 2.2E6 1 2.0E6 I -135 7.0E5 1 2.0E6 1 7.9ES 2.0E6 l 6.2E5 l 2.0E6 l 4.5ES l 2.0E6 l UN-ID 6.3E4 1 6.0E8 l 1.1E5 6.0E8 , 1.3E5 ' 6.0E8 l 1.0E5 l 6.0E8 I l I I I I I L I I H I I I I I I 1 I I 11 I I l l l l l l l l l l l l l l l l l l I i l l l l J l 1 1 I I I I I l l l l l l l I I I I I I I 4 l I l l l I l I i l l I L I I InhalationPathway, units =]h Food & Ground Pathway, units = (m

  • d APPMH uti/sec MAR 171986 2-31 Rev. 18 03-19-86

1 TABLE 2-5 ( DOSE PARAMETER R; FOR SECTOR P Page 5 of 5 f l Pathway = Trestles Bch Tower Distance = 2.0 miles l 1 X/Q = 2.1E-07 sec/m* D/Q = 6.8E-10 m 2 l l Infant l Child l Teen l Adult l l I I l lInhala-l Food & lInhala-l Food & lInhala-1 Food & lInhala- ! Food & l i l Radio-l tion i Ground L tion l Ground ltion l Ground ltion I Ground l 'Nuclide IPathwayl Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l l I l l l l l l l H -3 l 0.0E0 1 0.0E0 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 2.2E2 1 0.0E0 1 Cr-51 l 0.0E0 1 0.0E0 0.GE0 1 0.0E0 l 0.0E0 0.0E0 l 5.7E2 l 8.0E5 l Mn-54 1 0.0E0 l 0.0E0 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 1.3E4 l 2.4E8 l Co-57 L 0.0E0 1 0.0E0 0.0E0 0.0E0 0.0E0 1 0.0E0 5.4E? I 5.9E7 l l Co-58 0.0E0 l 0.0E0 l 0.0E0 i 0.0E0 ' O.0E0 l 0.0E0 1 24 l 6.5E7 I Co-60 0.0E0 l 0.0E0 0.0E0 l 0.0E0 ' O.0E0 1 0.0E0 ' 4.9E4 1 3.7E9 t l Sr-89 , 0.0E0 1 0.0E0 0.0E0 l 0.0E0 [ 0.0E0 1 0.0E0 5.2E4 l 3.7E3 l l Sr-90 l 0.0E0 0.0E0, 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 1.7E7 1 0.0E0 l 1 Zr-95 l 0.0E0 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 2.6E4 l 4.3E7 I i Nb-95 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 [ 0.0E0 1.8E4 l 2.3E7 i Te-129m J 0.0E0 1 0.0E0 1 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 6.3E3 l 3.4E6 1 Cs-134 0.0E0 l 0.0E0 l 0.0E0 0.0E0 1 0.0E0 1 0.0E0 l 1.5E5 1.2E9 ( Cs-136 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.5E4 2.6E7 L Cs-137 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 ' 1.1E5 J 1.8E9 i l Ba-140 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 3.7E4 l 3.5E6 l l Ce-141 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 2.1E4 1 2.3E6 I Ce-144 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1.4E5 1.2E7 l I -131 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 0.0E0 1 0.0E0 2.0E6 2.9E6 1 -133 0.0E0 I -135 0.0E0 ,1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 3.7E5 4.2E5 0.0E0 1 0.0E0 1 0.0E0 0.0E0 l 0.0E0 7.7E4 4.3E5 UN-10 i 0.0E0 i 0.0E0 l 0.0E0 1 0.0E0 '..O. 0E0 1 0.0E0 l 1.8E4 1.3E8 l l l I I I I ? I l i I i I 1 l l l I I l I l l l l l l l l 1 I I i i i l l I I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I i l i I I I I I Inhalation Pathway, units a K Food & Ground Pathway, units = I" II*"*/Yr) APPROVED uCt/sec - 7 ggg 2-32 Rev. 18 03-19-86

F ~ TABLE 2-6 (~ DOSE PARAMETER R FOR SECTOR Q g Page 1 of 7 l Pathway = State Park Office Trailer Distance = 0.6 miles l l X/Q = 2.2E-6 sec/m 8 D/Q = 1.2E-8 m

  • l l

Infant l Child l Teen l Adult l l I .l l l i l lInhala-l Food & lInhala-l Food & lInhala-1 Food & lInhala-l Food & i 6 IRadio-Ition l Ground ltion l Ground l tion l Ground ltion l Ground ! lNuclide Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway [ Pathway! l l l I I I I I I I l l l H -3 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 5.8E1 1 0.0E0 l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 1.5E2 l 2.1E5 l Mn-54 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.5E3 1 6.3E7 l l Co-57 I 0.0E0 l 0.0E0 i 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.4E3 1 1.6E7 l l Co-58 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 4.9E3 l 1.7E7 l l Co-60 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 1.3E4 l 9.8E8 l l Sr-89 L 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 'l 0.0E0 1 0.0E0 l 1.4E4 l 9.9E2 Sr-90 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 4.5E6 l 0.0E0 i Zr-95 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 6.9E3 l 1.1E7 l l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 4.8E3 1 6.2E6 l Te-129m 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.7E3 i 9.0E5 i Cs-134 ' O.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 J 3.9E4 3.1E8 l L Cs-136 0.0E0 1 0.0E0 i 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 6.7E3 6.9E6 I ( l Cs-137 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 2.8E4 1 4.7E8 l l Ba-140 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0. 1.0E4 l 9.4E5 Ce-141 0.0E0 ' O.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 5.5E3 1 6.2E5 i Ce-144 0.0E0 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 3.7E4 1 3.2E6 l I -131 l 0.0E0 1 0.0E0 [ 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 5.4E5 l 7.9ES I -133 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 9.8E4 l 1.1E5 I I -135 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 2.0E4 i 1.2E5 I UN-ID 0.0E0 l 0.0E0 1 0.0E0 0.0E0 L 0.0E0 1 0.0E0 4.7E3 1 3.4E7 l 1 l l P I I I I I I I I I l 1 1 I l L I i l l l l 1 I I I I l i i i l i I I I I l l I I I I I I 1 i I I l l 1 I I I I I I I I I I I I I I i l l l l l l l 1 I I I I I i i l i l I i l I i i l l I I I i l l l I l i l I I I l l Inhalation Pathway, units = Food & Ground Pathway, units = (* [c'") APPROVED HAR 171986 2-33 Rev. 18 03-19-86

TABLE 2-6 ( DOSE PARAMETER R FOR SECTOR Q g Page 2 of 7 l Pathway = Surf.BeachGuardShack Distance = 0.7 miles l X/Q = 1.8E-06 sec/m' D/Q = 9.9E-09 m 8 l l Infant l Child l Teen I Adult l Inhala-l.cood & Inhala-l Food & Inhala-l Food &JInhala-l Food Radio-tion l Ground Ition l Ground l tion l Ground ltion l Ground l lNuclide Pathway l PathwaylPathway l Pathway l Pathway l Pathway l Pathway l Pathway l l l l l l l l l l l l l l l I I I I l H -3 l 0.0E0 l 0.0E0 0.0E0 0.CEO 0.0E0 l 0.0E0 1 2.9E2 l 0.0E0 l l Cr-51 l 0.0E0 l 0.0E0 ' O.0E0 0.0E0 0.0E0 l 0.0E0 l 7.6E2 l 1.1E6 l Mn-54 l 0.0E0 1 0.0E0 H 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.8E4 l 3.2E8 l Co-57 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 ' O.0E0 1 0.0E0 l 7.2E3 l 7.8E7 l l Co-58 0.0E0 l 0.0E0 1 0.0E0 ' O.0E0 0.0E0 1 0.0E0 l 2.4E4 l 8.7E7 l Co-60 0.0E0 0.0E0 1 0.0E0 0.0E0 l 0.0E0 1 0.0E0 l 6.5E4 l 4.9E9 l Sr-89 1 0.0E0 [ 0.0E0 l 0.0E0 ! 0.0E0 1 0.0E0 1 0.0E0 l 6.9E4 l 4.9E3 l Sr-90 1 0.GE0 l 0.0E0 1 0.0E0 0.0E0 1 0.0E0 l 0.0E0 1 2.3E7 l 0.0E0 l l Zr-95 0.0E0 0.0E0 1 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 3.4E4 ' 5.7E7 i Nb-95 0.0E0 0.0E0 l 0.0E0 0.0E0 0.0E0 1 0.0E0 l 2.4E4 3.1E7 l Te-129m l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 0.0E0 1 0.0E0 l 8.3E3 4.5E6 l Cs-134 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1.9E5 ' 1.6E9 i l Cs-136 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 3.3E4 L 3.4E7 l ( l Cs-137 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1.4E5 1 2.3E9 i Ba-140 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 ! 0.0E0 J 5.0E4 l 4.7E6 l i Ce-141 0.0E0 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 2.7E4 1 3.1E6 l l Ce-144 0.0E0 0.0E0 l' O.0E0 i 0.0E0 l 0.0E0 1 0.0E0 1 1.9E5 l 1.6E7 l l I -131 0.0E0 0.0E0 0.0E0 0.0E0 ' O.0E0 1 0.0E0 l 2.7E6 l 3.9E6 l 1 -133 0.0E0 l 0.0E0 0.0E0 T 0.0E0 0.0E0 1 0.0E0 l 4.9E5 l 5.6ES l I -135 l 0.0E0 ' O.0E0 1 0.0E0 l 0.0E0 0.0E0 l 0.0E0 ' 1.0E5 l 5.8E5 I I UN-10 l 0.0E0 0.0E0 l 0.0E0 0.0E0 0.0E0 ' O.0E0 2.4E4 l 1.7E8 l I I l* ' 4 l l 1 1 I I l 1 1 I I e I I I I I I l l L I I I I l 1 i i i I l l 1 l 1 I I I I T I I I I I I I l l I l 1 I I l l l 1 I I I I I l l l l l l l l l l l l 1-l l l 1 l I Inhalation Pathway, units = f 3 Food & Ground Pathway, units = (* Mm"m-.d APPROVED uC1/sec MAR 171986 2-34 Rev. 18 03-19-86

i TABLE 2-6 ( DOSE PARAMETER R FOR SECTOR Q g Page 3 of 7 l' Pathway = Enlisted 8each Recreation Building i Distance = 1.2 miles l l X/Q = 8.2E-7 sec/m2 0/Q = 4.0E-9 m 8 l l l Infant l Child l Teen Adult l Inhala-1 Food & Inhala-l Food & Inhala-Food & Inhala-l Food & l Radio-l tion i Ground ition l Ground ltion i Ground l tion l Ground l INuclide l Pathway l PathwaylPathway l PathwaylPathway Pathway Pathway l Pathway 1 l l l l l l l l l l l l l l H -3 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.6E2 1 0.0E0 1 l Cr-51 1 0.0E0 1 0.0E0 ! 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 9.5E2 l 1.3E6 l l Mn-54 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 2.2E4 l 3.9E8 Co-57 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 9.0E3 l 9.8E7 Co-58 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 3.0E4 ' 1.1E8 Co-60 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 8.1E4 6.1E9 i Sr-89 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 8.7E4 1 6.2E3 i Sr-90 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 2.8E7 l 0.0E0 Zr-95 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 ' 4.3E4 1 7.2E7 Nb-95 l 0.0E0 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 3.0E4 l 3.9E7 Te-129m j 0.0E0 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1.0E4 l 5.6E6 Cs-134 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 2.4E5 l 1.9E9 l Cs-136 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 4.2E4 l 4.3E7 l ( Cs-137 1 0.0E0 1 0.0E0 1 0.0E0 0.0E0 1 0.0E0 l 0.0E0 l 1.8E5 1 2.9E9 l 8a-140 1 0.0E0 0.0E0 1 0.0E0 0.0E0 l 0.0E0 l 0.0E0 1 6.2E4 l 5.9E6 l ) Ce-141 1 0.0E0 0.0E0 l 0.0E0 1 0.0E0 ! 0.0E0 1 0.0E0 l 3.4E4 l 3.9E6 l Ce-144 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 2.3E5 1 2.0E7 l 0 I -131 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 3.4E6 1 4.9E6 l l I -133 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 6.1E5 l 7.0E5 I I I -135 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 1.3E5 I 7.2E5 l UN-ID l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 2.9E4 l 2.1E8 l l l l l~ ' l l 1 I I i 1 I I l 1 1 I I I I I I I I I I I I l l l 1 f I I I I I l l 1 H I I I I I i l i I I l l l l l 1 l I l l i I l l I I I I I I I I I I I I I I I I I I l l I l l l l l i 1 l 1 l I l l I l l I l I l i l l l 'l I l l Inhalation Pathway, units = "C Food & Ground Pathway, units = 5 APPROVED t1AK 1 T 2-35 Rev. 18 03-19-86

e TA B LF. 2-6 ( DOSE PARAMETER R FOR SECTOR Q g Page 4 of 7 l Pathway = Sheep (Meat) and Shepherd Dictance = 1.6 miles l l X/Q = 5.6E-7 sec/m' 0/Q = 2.6E-9 m 2 l l Infant l Child l Teen l Adult lInhala-l Food & Inhala-l Food & Inhala-l Food & Inhala-l Food & 4 l Radio-l tion l Ground Ition l Ground ition l Ground Ition l Ground l [Nuclide l Pathway l PathwaylPathway l PathwaylPathway l Pathway l Pathway l Pathwayl i i i i i i i i j H -3 1 0.0E0 1 0.0E0 l 0.0E0 l 2.3E2 1 0.0E0 1 1.9E2 l 7.0E0 l 3.2E2 l l Cr-51 l 0.0E0 l 0.0E0 ! 0.0E0 1 1.3E2 1 0.0E0 l 2.6E2 l 1.8E1 l 2.6E4 l l Mn-54 I 0.0E0 l 0.0E0 l 0.0E0 l 2.0E3 l 0.0E0 l 3.6E3 1 4.3E2 l 7.6E6 l l Co-57 l 0.0E0 1 0.0E0 l 0.0E0 l 1.2E4 1 0.0E0 l 2.1E4 l 1.7E2 l 1.9E6 l l Co-58 l G.0E0 l 0.0E0 1 0.0E0 1 2.5E4 l 0.0E0 l 5.0E4 l 5.9E2 l 2.2E6 l l Co-60 l 0.0E0 l 0.0E0 j 0.0E0 l 9.4E4 j 0.0E0 l 1.9E5 l 1.6E3 l 1.2E8 I ) Sr-89 1 0.0E0 1 0.0E0 l 0.0E0 l 1.3E5 1 0.0E0 1 6.7E4 1 1.7E3 l 8.0E4 l Sr-90 1 0.0E0 l 0.0E0 1 0.0E0 1 2.7E6 l 0.0E0 1 2.1E6 ! 5.5E5 l 3.2E6 I Zr-95 1 0.0E0 l 0.0E0 l 0.0E0 l 1.6E5 l 0.0E0 l 2.9E5 l 8.3E2 l 1.9E6 [ Nb-95 1 0.0E0 1 0.0E0 1 0.0E0 l 6.0E5 l 0.0E0 l 1.2E6 i 5.7E2 l 2.9E6 l Te-129m l 0.0E0 l 0.0F0 1 0.0E0 1 1.5E6 I 0.0E0 l 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 1 0.0E0 1 0.0E0 i 0.0E0 l 3.7E5 1 0.0E0 l 3.0E5 l 4.7E3 l 3.8E7 Cs-136 1 0.0E0 l 0.0E0 l 0.0E0 1 1.3E4 l 0.0E0 l 1.1E4 l 8.1E2 l 8.4E5 l ( Cs-137 1 0.0E0 1 0.0E0 1 0.0E0 l 3.2E5 1 0.0E0 1 2.4E5 1 3.4E3 l 5.7E7 l Ba-140 l 0.0E0 1 0.0E0 1 0.0E0 ! 1.3E4 1 0.0E0 l 1.1E4 ! 1.2E3 l 1.3E5 [ j Ce-141 1 0.0E0 l 0.0E0 l 0.0E0 l 3.8E3 1 0.0E0 ! 6.1E3 ! 6.6E2 l 8.5E4 l l Ce-144 1 0.0E0 1 0.0E0 l 0.0E0 [ 4.6E4 l 0.0E0 l 7.6E4 1 4.5E3 1 5.0E5 l l I -131 l 0.0E0 1 0.0E0 1 0.0E0 1 1.7E6 l 0.0E0 l 1.1E6 l 6.6E4 1 1.6E6 l l I -133 l 0.0E0 l 0.0E0 l 0.0E0 1 4.0E-2 l 0.0E0 1 2.2E-2 ! 1.2E4 1 1.3E4 I l I -135 1 0.0E0 1 0.0E0 1 0.0E0 l 2.8E-181 0.0E0 l 1.6E-18i 2.5E3 l 1.4E4 l l UN-10 l 0.0E0 l 0.0E0 1 0.0E0 l 2.8E5 l 0.0E0 l 2.4E5 I 5.7E2 I 4.4E6 I i l l 1 l-1 I I I T I l' l I I I I I I l a I I i i l l I I I I I I I I I I I I l l l l l 1 I I I I l l I I l I I I I 4 l i i I I I I I I i i l I i I I I i l l I I I I I i l i i 1 1 I I I i i l l I I i i l I I I l l l I I l l 1 I I I I i I Inhalation Pathway, units = C l Food & Ground Pathway, units = j APPROVED l t%K 17 N l 2-36 Rev. 18 l 03-19-86

s TABLE 2-6 ( DOSE PARAMETER R; FOR SECTOR Q Page 5 of 7 l Pathway = San Onofre Heights Distance = 1.5 miles l l X/Q = 6.2E-7 sec/m' 0/Q = 2.9E-9 m

  • l l

l Infant l Child l Teen l Adult l Inhali-l Food & Inhala-l Food & Inhala-l Food & Inhala-1 Food & s s -{ Radio-ltion l Ground ltion l Ground ltion I Ground l tion l Ground l lNuclide l Pathway l Pathway l Pathway l PathwaylPathway l Pathway! Pathway l Pathway l l i i i i l i i i i l H -3 l 6.5E2 l 0.0E0 l 1.1E3 l 0.0E0 l 1.3E3 l 0.0E0 l 1.3E3 1 0.0E0 i i Cr-51 1 3.6E2 l 3.7E6 l 1.1E3 1 3.7E6 1 3.0E3 1 3.7E6 l 3.3E3 1 3.7E6 l l Mn-54 1 2.5E4 l 1.1E9 l 4.3E4 l 1.1E9 l 6.7E4 l 1.1E9 1 7.7E4 l 1.1E9 i l Co-57 l 4.9E3 1 2.7E8 l 1.3E4 l 2.7E8 l 3.1E4 l 2.7E8 l 3.1E4 l 2.7E8 l l Co-58 l 1.1E4 l 3.0E8 l 3.4E4 l 3.0E8 l 9.5E4 l 3.0E8 l 1.1E5 l 3.0E8 i l Co-60 l 3.2E4 l 1.7E10 l 9.6E4 l 1.7E10.I 2.6E5 1 1.7E10 l 2.8E5 l 1.7E10 l Sr-89 l 4.0E5 l 1.7E4 l 6.0E5 l 1.7E4 l 4.3E5 l 1.7E4 i 3.0E5 1.7E4 l Sr-90 1 4.1E7 l 0.0E0 i 1.0E8 l 0.0E0 1 1.1E8 l 0.0E0 l 9.9E7 0.0E0 l Zr-95 l 2.2E4 l 2.0E8 l 6.1E4 l 2.0E8 l 1.5E5 l 2.0E8 l 1.5E5 l 2.0E8 l l ' Nb-95 l 1.3E4 l 1.1E8 l 3.7E4 l 1.1E8 l 9.7E4 l 1.1E8 l 1.0E5 i 1.1E8 l l Te-129m 1 3.2E4 l 1.6E7 l 5.0E4 l 1.6E7 I 5.2E4 l 1.6E7 1 3.7E4 l 1.6E7 l l Cs-134 1 7.0E5 l 5.5E9 l 1.0E6 1 5.5E9 l 1.1E6 I 5.5E9 l 8.5E5 1 5.5E9 l f I Cs-136-l 1.3E5 l 1.2E8 l 1.7E5 l 1.2E8 l 1.9E5 l 1.2E8 l 1.5E5 l 1.2E8 l \\ l Cs-137 1 6.1ES l 8.2E9 1 8.3E5 l 8.2E9 l 8.5E5 1 8.2E9 ! 6.2E5 l 8.2E9 l l Ba-140 l 5.6E4 l 1.6E7 l 7.4E4 l 1.6E7 l 2.3E5 l 1.6E7 l 2.2E5 l 1.6E7 l ) l Ce-141 l 2.2E4 l 2.1E7 l 5.7E4 l 1.1E7 l 1.3E5 l 1.1E7 ! 1.2E5 l 1.1E7 l l Ce-144 l 1.5ES l 5.6E7 [ 3.9E5 l 5.6E7 l 8.6E5 l 5.6E7 l 8.2E5 l 5.6E7 l l I -131 1 1.5E7 l 1.4E7 1 1.6E7 l 1.4E7 l 1.5E7 l 1.4E7 l 1.2E7 1 1.4E7 l l I -133 1 3.6E6 l 2.0E6 l 3.8E6 l 2.0E6 l 2.9E6 l 2.0E6 l 2.2E6 1 2.0E6 l l I -135 l 7.0E5 l 2.0E6 l 7.9ES l 2.0E6 l 6.2E5 l 2.0E6 1 4.5ES l 2.0E6 l l UN-ID l 6.3E4 1 6.0E8 l 1.1E5 l 6.0E8 l 1.3E5 l 6.0E8 l 1.0E5 l 6.0E8 l l l l l 1 l~ l l I i 1 1 I I I I I I I I i 1 I i i l I I I I l l l l l 1 I I I I I I l 1 I I I I I I i 1 1 i i I l l I I l l i l I l I I I -l i I I I i I i l I I I I I I I I I I l l l l 1 l I l i l I I I I I I i i l i I I I I I i l I i l Inhalation Pathway, units = YE r Food & Ground Pathway, units = uCi/sec APPROVED t%R 171986 2-37 Rev. 18 03-19-86

TABLE 2-6 -( DOSE PARAMETER R; FOR SECTOR Q Page 6 of 7 l Pathway = San Clemente Ranch (No Residents) Ofstance = 2.2 miles l l X/Q = 3.3E-7 sec/m' 0/Q = 1.4E-9 m 2 l l l Infant l Child l Teen l Adult Inhala-l Food &lInhala-l Food & Inhala-l Food & Inhala-l Food & l Radio-l tion l Ground l tion l Ground Ition l Ground [ tion l Ground l lNuclide l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathwayi l l l l l l l l l l l l 1 I I l l l 1 l H -3 l 0.0E0 l 0.0E0 1 0.0E0 l 4.0E3 l 0.0E0 l 2.6E3 l 0.0E0 l 2.3E3 i l Cr-51 l 0.0E0 l 0.0E0 l 0.0E0 i 6.1E6 1 0.0E0 l 1.0E7 l 0.0E0 l 1.2E7 l l Mn-54 1 0.0E0 1 0.0E0 l 0.0E0 l 6.5E8 l 0.0E0 l 9.2E8 l 0.0E0 l 9.4E8 i l Co-57 l 0.0E0 l 0.0E0 l 0.0E0 l 2.2E9 1 0.0E0 l 3.0E9 l 0.0E0 l 2.7E9 i l Co-58 1 0.0E0 l 0.0E0 1 0.0E0 l 3.7E8 l 0.0E0 l 5.9E8 l 0.0E0 l 6.1E8 l l Co-60 0.0E0 l 0.0E0 1 0.0E0 1 2.1E9 l 0.0E0 l 3.2E9 l 0.0E0 l 3.1E9 l 1 Sr-89 0.0E0 1 0.0E0 1 0.0E0 l 3.5E10 l 0.0E0 l 1.5E10 l 0.0E0 l 9.8E9 l l Sr-90 l 0.0E0 l 0.0E0 1 0.0E0 l 1.4E12 1 0.0E0 l 8.3E11 1 0.0E0 l 6.7E11 l l Zr-95 l 0.0E0 1 0.0E0 l 0.0E0 l 8.8E8 l 0.0E0 l 1.2E9 l 0.0E0 l 1.2E9 l l Nb-95 l 0.0E0 l 0.0E0 l 0.0E0 l 2.9E8 1 0.0E0 1 4.5E8 l 0.0E0 l 4.7E8 i l Te-129m l 0.0E0 1 0.0E0 1 0.0E0 l 2.9E9 l 0.0E0 l 1.8E9 1 0.0E0 1 1.2E9 l l Cs-134 1 0.0E0 1 0.0E0 l 0.0E0 l 2.6E10 l 0.0E0 l 1.6E10 l 0.0E0 l 1.1E10 1 ( l Cs-136 l 0.0E0 l 0.0E0 1 0.0E0 1 2.2E8 1 0.0E0 1 1.7E8 l 0.0E0 1 1.7E8 l l Cs-137 l 0.0E0 1 0.0E0 l 0.0E0 l 2.4E10 l 0.0E0 l 1.4E10 l 0.0E0 1 9.1E9 l l Ba-140 l 0.0E0 l 0.0E0 l 0.0E0 1 2.8E8 l 0.0E0 1 2.1E8 l 0.0E0 l 2.6E8 I I Ce-141 1 0.0E0 1 0.0E0 l 0.0E0 l 4.0E8 l 0.0E0 l 5.3E8 1 0.0E0 1 5.0E8 i l Ce-144 l 0.0E0 l 0.0E0 l 0.0E0 l 1.0E10 1 0.0E0 l 1.3E10 1 0.0E0 l 1.1E10 i l I -131 1 0.0E0 1 0.0E0 l 0.0E0 1 4.8E10 1 0.0E0 l 3.1E10 l 0.0E0 l 3.8E10 l l I -133 l 0.0E0 l 0.0E0 1 0.0E0 l 8.1E8 l 0.0E0 l 4.6E8 l 0.0E0 1 5.3E8 i i I -135 l 0.0E0 l 0.0E0 1 0.0E0 l 9.8E6 l 0.0E0 1 5.7E6 1 0.0E0 1 6.6E6 l l UN-ID l 0.0E0 1 0.0E0 l 0.0E0 l 2.7E9 l 0.0E0 l 1.9E9 1 0.0E0 1 1.3E9 l 1 1 I I I I" I l 1 I I I I I I I I l l l l l l I I I l l l l 1 1 I i 1 l l l l l l l l l 1 1 I i l l 1 I I i l l 1 I I I l l l l l l l l l l I I I I I I I l l 1 I I l l I I I l 1 l l I l l l l l l l l l l l 1 1 I I i l i I I I l l l l I I I InhalationPathway, units =] t Food & Ground Pathway, units = (* ""I f APPROVED t1AR 171986 2-38 Rev. 18 03-19-86 \\

TABLE 2-6 ( DOSE PARAMETER R; FOR SECTOR Q Page 7 of 7 l Pathway = S. C. Res W Garden Distance = 3.9 miles i l X/Q = 1.3E-07 sec/m' 0/4 = 4.5E-10 m 2 l l Infant l Child l Teen l Adult l l l 4 l lInhala-l Food & lInhala-l Food & IInhala-l Food & IInhala-l Food & i l Radio-l tion l Ground l tion i Ground Ition l Ground Ition l Ground l lNuclide l Pathway l PathwaylPathway l Pathway l Pathway l Pathway l Pathway l Pathway! I i i i i i l i i i l H -3 1 6.5E2 l 0.0E0 l 1.IE3 l 4.0E3 l 1.3E3 l 2.6E3 l 1.3E3 l 2.3E3 l I Cr-51 l 3.6E2 1 3.7E6 l 1.1E3 l 9.8E6 l 3.0E3 l 1.4E7 l 3.3E3 l 1.5E7 l l Mn-54 l 2.5E4 l 1.1E9 l 4.3E4 { 1.8E9 l 6.7E4 l 2.0E9 1 7.7E4 l 2.0E9 l l Co-57 l 4.9E3 l 2.7E8 l 1.3E4 l 2.5E9 1 3.1E4 1 3.3E9 i 3.1E4 l 2.9E9 I I Co-58 l 1.1E4 l 3.0E8 1 3.4E4 l 6.7E8 l 9.5E4 l 8.9E8 l 1.1ES l 9.1E8 l l Co-60 1 3.2E4 l 1.7E10 l 9.6E4 l 1.9E10 l 2.6E5 1 2.0E10 l 2.8E5 l 2.0E10 l l Sr-89 l 4.0E5 I 1.7E4 l 6.0E5 1 3.5E10 l 4.3E5 l 1.5E10 l 3.0E5 l 9.8E9 l l Sr-90 1 4.1E7 l 0.0E0 1 1.0E8 l 1.4E12 l 1.1E8 l 8.3E11 l 9.9E7 l 6.7E11 l l Zr-95 l 2.2E4 l 2.0E8 l 6.1E4 l 1.1E9 l 1.5E5 1 1.4E9 l 1.5E5 I 1.4E9 l l Nb-95 ! 1.3E4 l 1.1E8 1 3.7E4 j 4.0E8 l 9.7E4 l 5.6E8 l 1.0E5 1 5.8E8 i l Te-129m l 3.2E4 l 1.6E7 l 5.0E4 l 2.9E9 l 5.2E4 l 1.8E9 I 3.7E4 l 1.2E9 l Cs-134 I 7.0E5 l 5.5E9 l 1.0E6 l 3.1E10 l 1.1E6 l 2.2E10 l 8.5E5 l 1.6E10 l r l Cs-136 l 1.3E5 l 1.2E8 l 1.7E5 l 3.4E8 l 1.9E5 l 2.9E8 l 1.5E5 l 2.9E8 l l Cs-137 1 6.1ES l~8.2E9 I 8.3E5 1 3.2E10 l 8.5E5 1 2.2E10 ! 6.2E5 l 1.7E10 l l Ba-140 l 5.6E4 l 1.6E7 l 7.4E4 l 2.9E8 l 2.3E5 1 2.3E8 l 2.2E5 1 2.8E8 l Ce-141 l 2.2E4 l 1.1E7 l 5.7E4 1 4.1E8 l 1.3E5 I 5.4E8 l 1.2E5 I 5.1E8 l l Ce-144 l 1.5E5 l 5.6E7 l 3.9E5 l 1.0E10 l 8.6E5 l 1.3E10 l 8.2E5 [ 1.1E10 i .l I -131 l 1.5E7 l 1.4E7 l 1.6E7 l 4.8E10 l 1.5E7 l 3.1E10 l 1.2E7 l 3.8E10 l l I -133 1 3.6E6 l 2.0E6 l 3.8E6 l 8.1E8 l 2.9E6 1 4.6E8 l 2.2E6 1 5.3E8 l l I -135 l 7.0E5 1 2.0E6 1 7.9E5 l 1.2E7 l 6.2E5 l 7.7E7 l 4.5E5 l 8.6E6 l l UN-IO l 6.3E4 l 6.0E8 l 1.1ES l 3.3E9 I,1.3E5 1 2.5E9 l 1.0E5 l 1.9E9 l 1 I I I I I I I i l l 1 I I I l l l l l l l l l l 1 I I l 1 1 I I I I l l l I I I I I I l l l l l 1 l l l 1 I I I I I l i I I l I I l I I I I I I I I I I I i 1 i I I I I I i l l 1 I I I I l 1 I I 1 i I I i l i l I I l 1 1 I i l i I I I I I InhalationPathway, units =h] Food & Ground Pathway, units = plg R 1 'l M 2-39 Rev. 18 03-19-86 t

TABLE 2-7 i DOSE PARAMETER R; FOR SECTOR R Page 1 of 4 r 1 Pathway = Sheep (Meat) and Shepherd Distance = 0.9 miles l 1 X/Q = 8.3E-7 sec/m 2 0/0 = 5.2E-9 m 2 l l Infant l Child l Teen l Adult l l l l l i l lInhala-l Food & IInhala-l Food & lInhala-1 Food & IInhala-l Food & 1 i l Radio-Ition i Ground l tion l Ground l tion l Ground l tion l Ground l lNuclide lPathway l Pathway l Pathway l PathwaylPathway l Pathway l Pathway l Pathwayi l I l l l l l l l l l H -3 1 0.0E0 1 0.0E0 l 0.0E0 l 2.3E2 l 0.0E0 l 1.9E2 1 7.0E0 l 3.2E2 l l Cr-51 1 0.0E0 1 0.0E0 1 0.0E0 l 1.3E2 1 0.0E0 1 2.6E2 l 1.8E1 1 2.6E4 l l Mn-54 1 0.0E0 1 0.0E0 1 0.0E0 l 2.0E3 1 0.0E0 1 3.6E3 1 4.3E2 1 7.6E6 l l Co-57 l 0.0E0 l 0.0E0 1 0.0E0 l 1.2E4 1 0.0E0 l 2.1E4 l 1.7E2 1 1.9E6 l l Co-58 I 0.0E0 l 0.0E0 -l 0.0E0 1 2.5E4 1 0.0E0 l 5.0E4 l 5.9E2 l 2.2E6 l l Co-60 l 0.0E0 l 0.0E0 1 0.0E0 l 9.4E4 l 0.0E0 1 1.9E5 l 1.6E3 1 1.2E8 l l Sr-89 l 0.0E0 1 0.0E0 l 0.0E0 1 1.3E5 l 0.0E0 1 6.7E4 ! 1.7E3 l 8.0E4 l Sr-90 l 0.0E0 1 0.0E0 1 0.0E6 l 2.7E6 1 0.0E0 l 2.1E6 1 5.5E5 1 3.2E6 l Zr-95 l 0.0E0 l 0.0E0 1 0.0E0 l 1.6ES l 0.0E0 1 2.9E5 l 8.3E2 1 1.9E6 l l Nb-95 1 0.0E0 l 0.0E0 1 0.0E0 l 6.0E5 l 0.0E0 l 1.2E6 1 5.7E2 1 2.9E6 l l Te-129m i 0.0E0 1 0.0E0 1 0.0E0 1 1.5E6 I 0.0E0 l 1.2E6 1 2.0E2 l 1.5E6 l l Cs-134 l 0.0E0 l 0.0E0 l 0.0E0 l 3.7E5 1 0.0E0 1 3.0E5 I 4.7E3 1 3.8E7 I ( l Cs-136 l 0.0E0 1 0.0E0 ! 0.0E0 l 1.3E4 1 0.0E0 l 1.1E4 l 8.1E2 1 8.4E5 l 1 Cs-137 1 0.0E0 l 0.0E0 1 0.0E0 l 3.2E5 l 0.0E0 l 2.4E5 l 3.4E3 l 5.7E7 l l Ba-140 1 0.0E0 1 0.0E0 l 0.0E0 l 1.3E4 1 0.0E0 l 1.1E4 l 1.2E3 l 1.3E5 I ) l Ce-141 l 0.0E0 1 0.0E0 1 0.0E0 l 3.8E3 l 0.0E0 l 6.1E3 1 6.6E2 l 8.5E4 I I Ce-144 1 0.0E0 1 0.0E0 1 0.0E0 l 4.6E4 1 0.0E0 l 7.6E4 1 4.5E3 1 5.0E5 l I -131 l 0.0E0 1 0.0E0 l 0.0E0 l 1.7E6 1 0.0E0 l 1.1E6 l 6.6E4 1 1.6E6 I I -133 1 0.0E0 1 0.0E0 1 0.0E0 1 4.0E-2 1 0.0E0 l 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 1 0.0E0 1 0.0E0 l 0.0E0 l 2.8E-18j 0.0E0 l 1.6E-18l 2.5E3 l 1.4E4 l l UN-IO l 0.0E0 1 0.0E0 l 0.0E0 l 2.8E5 1 0.0E0 1 2.4E5 l 5.7E2 l 4.4E6 I I l 1 1 I" l I 4 I I I I L I I I I I I I I i 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I l l 1 1 I I I I I I l 1 l l l l l l I I I I I i l I I I I i l I I I I I I I I I I I 'l I I I I' I I i i i i I Inhalation Pathway, units = "C 2 Food & Ground Pathway, units = (* j APPROVED l MAR l l D D 2-40 Rev. 18 03-19-86

1 TABLE 2-7 1 DOSE PARAMETER R; FOR SECTOR R ( l Pathway = San Onofre Mobile Homes Distance = 1.3 miles l I X/Q = 4.7E-7 sec/m' 0/0 u 2.8E-9 m 2 l l l Infant l Child l Teen l Adult I l l l l 4 i 4 l lInhala-l Food & IInhala-l Food & IInhala-l Food & lInhala-l Food & l l Radio-Ition l Ground Ition l Ground Ition l Ground ltion l Ground l INuclide l Pathway lPathwaylPathwaylPathwaylPathwaylPathwaylPathwayl Pathway l l l l l l l l l l l I H -3 l 6.5E2 I 0.0E0 l 1.1E3 1 0.0E0 l 1.3E3 1 0.0E0 l 1.3E3 1 0.0E0 l 1 l Cr-51 ! 3.6E2 1 3.7E6 l 1.1E3 l 3.7E6 1 3.0E3 1 3.7E6 l 3.3E3 l 3.7E6 l l Mn-54 I 2.5E4 l 1.1E9 l 4.3E4 l 1.1E9 I 6.7E4 l 1.1E9 l 7.7E4 l 1.1E9 l l Co-57 l 4.9E3 l 2.7E8 l 1.3E4 l 2.7E8 l 3.1E4 l 2.7E8 l 3.1E4 l 2.7E8 l I Co-58 l 1.1E4 l 3.0E8 1 3.4E4 1 3.0E8 l 9.5E4 l~3.0E8 l 1.1E5 1 3.0E8 l I Co-60 l 3.2E4 l 1.7E10 l 9.6E4 l 1.7E10 1 2.6E5 l 1.7E10 1 2.8E5 l 1.7E10 l l Sr-89 I 4.0E5 l 1.7E4 I 6.0E5 l 1.7E4 l 4.3E5 l 1.7E4 l 3.0E5 1 1.7E4 l l Sr-90 l 4.1E7 1 0.0E0 l 1.0E8 l 0.0E0 1 1.1E8 l 0.0E0 l 9.9E7 l 0.0E0 l l Zr-95 1 2.2E4 l 2.0E8 l 6.1E4 l 2.0E8 l 1.5E5 l 2.0E8 l 1.5E5 1 2.0E8 l l Nb-95 l 1.3E4 l 1.1E8 l 3.7E4 l 1.1E8 i 9.7E4 1 1.1E8 l 1.0E5 l 1.1E8 I l Te-129m l 3.2E4 l 1.6E7 l 5.0E4 l 1.6E7 l 5.2E4 l 1.6E7 l 3.7E4 l 1.6E7 l l Cs-134 I 7.0E5 l 5.5E9 l 1.0E6 1 5.5E9 1 1.1E6 I 5.5E9 l 8.5E5 I 5.5E9 I ( l Cs-136 l 1.3E5 l 1.2E8 l 1.7E5 l 1.2E8 l 1.9E5 l 1.2E8 l 1.5E5 l 1.2E8 l l Cs-137 l 6.1ES l 8.2E9 1 8.3E5 l 8.2E9 l 8.5E5 l 8.2E9 l 6.2E5 l 8.2E9 l l Ba-140 l 5.6E4 i 1.6E7 i 7.4E4 l 1.6E7 l 2.3E5 l 1.6E7 l 2.2E5 l 1.6E7 l l Ce-141 1 2.2E4 l 1.1E7 l 5.7E4 l 1.1E7 l 1.3E5 l 1.1E7 l 1.2E5 l 1.1E7 l l Ce-144 1 1.5E5 l 5.6E7 l 3.9E5 I 5.6E7 l 8.6ES l 5.6E7 l 8.2E5 I 5.6E7 l l I -131 l 1.5E7 l 1.4E7 l 1.6E7 l 1.4E7 l 1.5E7 l 1.4E7 l 1.2E7 l 1.4E7 I I I -133 1 3.6E6 l 2.0E6 1 3.8E6 l 2.0E6 1 2.9E6 l 2.0E6 l 2.2E6 l 2.0E6 i l I -135 l 7.0E5 l 2.0E6 l 7.9E5 l 2.0E6 l 6.2E5 l 2.0E6 l 4.5E5 1 2.0E6 I I UN-ID l 6.3E4 l 6.0E8 l 1.1ES l 6.0E8 l 1.3E5 I 6.0E8 l 1.0E5 l 6.0E8 l I I I I I f I I l I I I I i l l 1 I I I I I I I I I I I l I I I I I l l 1 l l l l t i I l l I I l I I I l l l 1 I I i l l 1 l l I I I I I I I I I I I I I l 1 I I I I I i i i i l l 1 I i l I l l l I I I I I I i l f I l l 1 I I I t I i i l l I I I I I I I l Inhalation Pathway, units = h" Food & Ground Pathway, units = pCi/sec g g 7 jggg 2-41 Rev. 18 03-19-86 i L. )

TABLE 2-7 DOSE PARAMETER R; FOR SECTOR R l Pathway =SanClementeRanch(NoResidents) Distance = 2.3 miles l l X/Q = 2.0E-7 sec/m' 0/Q = 1.0E-9 m 2 l Infant l Child l Teen Adult l'lnhala-l Food & lInhala-l Food & lInhala,' Food &. i 'Inhala-1 Food & l l Radio-l tion i Ground ltion I Ground ltion Ground [ tion l Ground I INuclide IPathway l PathwaylPathway Pathway l Pathway Pathway l Pathway l Pathway l l l l l l l l l H -3 1 0.0E0 1 0.0E0 l 0.0E0 ' 4.0E3 L 0.0E0 1 2.6E3 ' O.0E0 1 2.3E3 l l Cr-51 1 0.0E0 1 0.0E0 1 0.0E0 6.1E6 0.0E0 l 1.0E7 0.0E0 1 1.2E7 I Mn-54 l 0.0E0 1 0.0E0 1 0.0E0 l 6.5E8 0.0E0 l 9.2E8 0.0E0 1 9.4E8 l Co-57 1 0.0E0 -l 0.0E0 l 0.0E0 l 2.2E9 0.0E0 l 3.0E9 l 0.0E0 1 2.7E9 i Co-58 l 0.0E0 l 0.0E0 l 0.0E0 1 3.7E8 ) 0.0E0 l 5.9E8 1 0.0E0 1 6.1E8 I l Co-60 l 0.0E0 0.0E0 l 0.0E0 l 2.1E9 1 0.0E0 l 3.2E9 1 0.0E0 l 3.1E9 l l Sr-89 l 0.0E0 0.0E0 l 0.0E0 1 3.5E10 l 0.0E0 l 1.5E10 1 0.0E0 9.8E9 l l Sr-90 1 0.0E0 l 0.0E0 1 0.0E0 l 1.4E12 1 0.0E0 l 8.3E11 l 0.0E0 < 6.7E11 l l Zr-95 l 0.0E0 l 0.0E0 1 0.0E0 l 8.8E8 i 0.0E0 l 1.2E9 l 0.0E0 1 1.2E9 l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 1 2.9E8 l 0.0E0 l 4.5E8 l 0.0E0 1 4.7E8 l Te-129m 1 0.0E0 1 0.0E0 1 0.0E0 l 2.9E9 l 0.0E0 1 1.8E9 l 0.0E0 l 1.2E9 l Cs-134 1 0.0E0 l 0.0E0 l 0.0E0 l 2.6E10 l 0.0E0 1 1.6E10 1 0.0E0 1 1.1E10 i Cs-136 l 0.0E0 l 0.0E0 1 0.0E0 1 2.2E8 1 0.0E0 l 1.7E8 1 0.0E0 1 1.7E8 I / Cs-137 l 0.0E0 l 0.0E0 1 0.0E0 l 2.4E10 1 0.0E0 1 1.4E10 1 0.0E0 l 9.1E9 l 8a-140 1 0.0E0 0.0E0 1 0.0E0 1 2.8E8 1 0.0E0 1 2.1E8 1 0.0E0 l 2.6E8 1 3 Ce-141 l 0.0E0 1 0.0E0 1 0.0E0 1 4.0E8 ' O.0E0 l 5.3E8 l 0.0E0 l 5.0E8 l l Ce-144 ! 0.0E0 l 0.0E0 l 0.0E0 1 1.0E10 0.0E0 l 1.3E10 1 0.0E0 l 1.1E10 l l I -131 0.0E0 l 0.0E0 l 0.0E0 l 4.8E10 1 0.0E0 1 3.1E10 1 0.0E0 1 3.8E10 l l I -133, 0.0E0 l 0.0E0 1 0.0E0 l 8.1E8 1 0.0E0 1 4.6E8 l 0.0E0 l 5.3E8 I I I -135 1 0.0E0 1 0.0E0 1 0.0E0 1 9.8E6 1 0.0E0 1 5.7E6 1 0.0E0 l 6.6E6 l l UN-ID l 0.0E0 l 0.0E0 1 0.0E0 1 2.7E9 l I I 1 0.0E0 1.9E9 1 0.0E0 1 1.3E9 l l~ l I. I I I I l l l l l I I I I i 1 I I l l 1 1 I I I I l I I l l 1 I i l i I I i I I I i l i I I I I I I I I I I I l i I I i l I I I I I I I I I l l l l I I I I I I I I I I I I I I I L 1 I i I i I l l l 1 Inhalation Pathway, units = Food & Ground Pathway, units = (* d j APPROVED MAR 17 W 2-42 Rev. 18 03-19-86

TABLE 2-7 ( DOSE PARAMETER R; FOR SECTOR R Page 4 of 4 s l Pathway = SC Ranch Packing Distance = 2.6 miles l l X/Q = 1.7E-07 sec/m' 0/Q = 8.2E-10 m

  • l l

Infant l Child l Teen l Adult l l Inhala-l Food & Inhala-l Food & Inhala-l Food & Inhala-l Food & l Radio-l tion l Ground Ition l Ground l tion l Ground ition l Ground i INuclide iPathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l i i i i i i i i i i l H -3 1 0.0E0 1 0.0E0 l 0.0E0 l 4.0E3 l 0.0E0 l 2.6E3 l 1.3E3 1 2.3E3 l l Cr-51 1 0.0E0 l 0.0E0 1 0.0E0 1 6.1E6 1 0.0E0 1 1.0E7 l 3.3E3 l 1.5E7 i i Mn-54 l 0.0E0 l 0.0E0 1 0.0E0 l 6.5E8 l 0.0E0 1 9.2E8 l 7.7E4 l 2.0E9 l l Co-57 l 0.0E0 l 0.0E0 l 0.0E0 l 2.2E9 l 0.0E0 l 3.0E9 1 3.1E4 1 2.9E9 l l Co-58 l 0.0E0 1 0.0E0 1 0.0E0 l 3.7E8 I 0.0E0 l 5.9E8 l 1.1E5 l 9.1E8 I l Co-60 1 0.0E0 1 0.0E0 1 0.0E0 l 2.1E9.1 0.0E0 l 3.2E9 l 2.8E5 1 2.0E10 l l Sr-89 l 0.0E0 1 0.0E0 1 0.0E0 l 3.5E10 ! 0.0E0 l 1.5E10 1 3.0E5 l 9.8E9 i l Sr-90 1 0.0E0 ' O.0E0 1 0.0E0 l 1.4E12 l 0.0E0 l 8.3E11 l 9.9E7 l 6.7E11 l l Zr-95 l 0.0E0. 0.0E0 1 0.0E0 1 8.8E8 l 0.0E0 1 1.2E9 l 1.5ES I 1.4E9 i l Nb-95 1 0.0E0 1 0.0E0 l 0.0E0 1 2.9E8 i 0.0E0 l 4.5E8 l 1.0E5 i 5.8E8 l l Te-129m 1 0.0E0 l 0.0E0 1 0.0E0 l 2.9E9 l 0.0E0 l 1.8E9 l 3.7E4 l 1.2E9 l l Cs-134 l 0.0E0 1 0.0E0 1 0.0E0 l 2.6E10 l 0.0E0 l 1.6E10 l 8.5E5 l 1.6E10 l l Cs-136 l 0.0E0 l 0.0E0 1 0.0E0 l 2.2E8 [ 0.0E0 l 1.7E8 l 1.5E5 l 2.9E8 l ( l Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 l 2.4E10 1 0.0E0 1 1.4E10 1.6.2E5 l 1.7E10 l l Ba-140 l 0.0E0 1 0.0E0 1 0.0E0 1 2.8E8 l 0.0E0 1 2.1E8 1 2.2E5 1 2.8E8 ! l Ce-141 l 0.0E0 1 0.0E0 l 0.0E0 l 4.0E8' l 0.0E0 l 5.3E8 l 1.2E5 ! 5.IE8 l Ce-144 l 0.0E0 1 0.0E0 l 0.0E0 l 1.0E10 l 0.0E0 1 1.3E10 l 8.2E5 l 1.1E10 ! l I -131 1 0.0E0 l 0.0E0 l 0.0E0 l 4.8E10 1 0.0E0 1 3.1E10 1 1.2E7 l 3.8E10 l l I -133 l 0.0E0 l 0.0E0 l 0.0E0 1 8.1E8 1 0.0E0 1 4.6E8 1 2.2E6 1 5.3E8 I l I -135 l 0.0E0 l 0.0E0 1 0.0E0 l 9.8E6 ? 0.0E0 l 5.7E6 l 4.5E5 i 8.6E6 ! l UN-ID l 0.0E0 1 0.0E0 l 0.0E0 l 2.7E9 1 0.0E0 l 1.9E9 l 1.0E5 l 1.9E9 i I I I i r' l I I l 1 I I l l 1 l l 1 1 I I I I l 1 I I I I l l l I I I I I I I l l I I I I I I I I I I I I I I I I I i I I I 1 1 1 I I I I 1 I I I I I I I I I I I I I I I I i i i I i l I l I I l 1 I I i l 1 I i l i I I I I l 1 I I l I InhalationPathway, units =] Food & Ground Pathway, units = APPROVED MAR 171986 2-43 Rev. 18 I 03-19-86

TABl.E 2-8 j ( DOSE PARAMETER R. FOR SECTOR A Page 1 of 2 i l Pathway = Sheep (Meat) and Shepherd Distance = 0.2 miles l l X/Q = 6.7E-6 sec/m' 0/Q = 5.2E-8 m r g l l Infant l Child l Teen i Adult l l l l l i i i l lInhala-l Food & lInhala-l Food & IInhala-i Food & IInhala-l Food & l iRadio-Ition l Ground ition l Ground l tion ! Ground l tion i Ground l lNuclide [ Pathway l PathwaylPathway l PathwaylPathway l PathwayjPathway l Pathway l l i i i i i i i i i l H -3 1 0.0E0 1 0.0E0 l 0.0E0 l 2.3E2 l 0.0E0 l 1.9E2 l 7.0E0 l 3.2E2 l l Cr-51 1 0.0E0 1 0.0E0 1 0.0E0 l 1.3E2 1 0.0E0 l 2.6E2 l 1.8E1 1 2.6E4 l l Mn-54 1 0.0E0 1 0.0E0 l 0.0E0 1 2.0E3 l 0.0E0 l 3.6E3 l 4.3E2 1 7.6E6 l l Co-57 I 0.0E0 1 0.0E0 l 0.0E0 l 1.2E4 l 0.0E0 l 2.1E4 l 1.7E2 l 1.9E6 l l Co-58 l 0.0E0 l 0.0EO. l 0.0E0 l 2.5E4 1 0.0E0 1 5.0E4 l 5.9E2 l 2.2E6 I I Co-60 l 0.0E0 1 0.0E0 1 0.0E0 l 9.4E4.1 0.0E0 1 1.9ES l 1.6E3 1 1.2E8 l l Sr-89 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E5 l 0.0E0 l 6.7E4 l 1.7E3 1 8.0E4 l l Sr-90 l 0.0E0 1 0.0E0 l 0.0E0 l 2.7E6 1 0.0E0 ! 2.1E6 l 5.5E5 l 3.2E6 l l Zr-95 l 0.0E0 l 0.0E0 l 0.0E0 1 1.6E5 l 0.0E0 l 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 l 6.0E5 1 0.0E0 l 1.2E6 l 5.7E2 1 2.9E6 l l Te-129m l 0.0E0 l 0.0E0 1 0.0E0 l 1.5E6 l 0.0E0 1 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 I 0.0E0 l 0.0E0 1 0.0E0 1 3.7E5 1 0.0E0 1 3.0E5 1 4.7E3 1 3.8E7 l l Cs-136 l 0.0E0 l 0.0E0 1 0.0E0 1 1.3E4 1 0.0E0 l 1.1E4 l 8.1E2 l 8.4E5 l ( l Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 l 3.2E5 l 0.0E0 l 2.4E5 l 3.4E3 1 5.7E7 l l Ba-140 1 0.0E0 l 0.0E0 1 0.0E0 l 1.3E4 1 0.0E0 l 1.1E4 l 1.2E3 l 1.3E5 l l Ce-141 1 0.0E0 l 0.0E0 l 0.0E0 l 3.8E3 1 0.0E0 l 6.1E3 l 6.6E2 1 8.5E4 l l Ce-144 l 0.0E0 l 0.0E0 l 0.0E0 1 4.6E4 1 0.0E0 l 7.6E4 l 4.5E3 l 5.0E5 l l I -131 1 0.0E0 l 0.0E0 l 0.0E0 l 1.7E6 l 0.0E0 l 1.1E6 l 6.6E4 l 1.6E6 l l I -133 l 0.0E0 l 0.0E0 1 0.0E0 l 4.0E-2 [ 0.0E0 1 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 l 0.0E0 l 0.0E0 1 0.0E0 l 2.8E-181 0.0E0 l 1.6E-18i 2.5E3 l 1.4E4 l l UH-ID l 0.0E0 1 0.0E0 l 0.0E0 l 2.8E5 1 0.0E0 l 2.4E5 l 5.7E2 l 4.4E6 l l l 1 l 1 I' I I I I I I I I i i l i l i i I 1 1 I I I I I I I I I I I I I l I I I I I I i l l I I I I I i l I I I I I I I l i I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I i 1 1 I I I I I I I I I I I I I I I I I I I I t i ,I i Inhalation Pathway, units = 5" "} Food & Ground Pathway, units = 3 APPROVED t%R 171986 2-44 Rev. 18 03-19-86

TABLE 2-8 ( DOSE PARAMETER R; FOR SECTOR A Page 2 of 2 l Pathway = Camp San Mateo Distance = 3.6 miles l l X/Q = 7.1E-8 sec/m' 0/Q.= 4.1E-10 m.: j l Infant l Child l Teen l Adult l l l l i i l lInhala-l Food & lInhala-1 Food & lInhala-l Food & lInhala-l Food & I l Radio-l tion I Ground l tion I Ground [ tion l Ground ltion l Ground i INuclide l Pathway l Pathway l Pathway l PathwaylPathway l PathwaylPathway l Pathway l l I I l l l 1 l l 1 I I I I I I l H -3 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 1.3E3 l 0.0E0 l l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 3.3E3 l 3.7E6 l l Mn-54 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 7.7E4 l 1.1E9 1 l Co-57 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 3.1E4 l 2.7E8 l l Co-58 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 1.1E5 I 3.0E8 i l Co-60 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 2.8E5 l 1.7E10 ! l Sr-89 l 0.0F0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 3.0E5 l 1.7E4 l l Sr-90 l 0.bt0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 9.9E7 1 0.GE0 l l Zr-95 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 1.5E5 l 2.0E8 l l Nb-95 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.0E5 l 1.1ES i l Te-129m l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 3.7E4 l 1.6E7 l l Cs-134 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 8.5E5 I 5.5E9 i l Cs-136 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 1.5E5 l 1.2E8 ( l Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 6.2E5 l 8.2E9 l l Ba-140 1 0.0E0 1 0.0E0 1 0.0E0 i 0.0E0 1 0.0E0 1 0.0E0 l 2.2E5 1 1.6E7 I l Ce-141 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.2E5 l 1.1E7 l i l Ce-144 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 8.2E5 1 5.6E7 i l I -131 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 1.2E7 l 1.4E7 l l 1 -133 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 2.2E6 1 2.0E6 l l I -135 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 4.5E5 1 2.0E6 l l UN-ID l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.0E5 l 6.0E8 l l l l l l l~ l l l I I I i l l 1 I I I I I l l 1 I l l l l l l I I I I I I I I I l l l l l l l l l l l l l I I l l 1 1 I I I I I I I I I l l l 1 I I I I I I I I I I I i l i I I I I g e e t t i f f i Inhalation Pathway, units = "C" Food & Ground Pathway, units = APPR0yED ( 3102c MAR 171986 2-45 Rev. 18 03-19-86 i

TABLE 2-9 ( DOSE PARAMETER R; FOR SECTOR B Page 1 of 2 l Pathway = Sheep (Meat)andShepherd Distance = 0.2 miles l l X/Q = 6.1E-6 sec/m' 0/Q = 5.3E-8 m r l l Infant l Child l Teen l Adult l l l I l i i i l lInhala-l Food & lInhala-1 Food & IInhala-1 Food & lInhala-1 Food & I l Radio-l tion l Ground Ition l Ground l tion l Ground { tion i Ground l lNuclide l Pathway l PathwayjPathway l PathwaylPathway l PathwaylPathway l Pathwayl i i i I i i i i i l l H -3 l 0.0E0 l 0.0E0 1 0.0E0 1 2.3E2 l 0.0E0 1 1.9E2 I 7.0E0 l 3.2E2 l l Cr-51 l 0.0E0 1 0.0E0 1 0.0E0 l 1.3E2 1 0.0E0 l 2.6E2 i 1.8E1 1 2.6E4 l l Mn-54 l 0.0E0 ! 0.0E0 l 0.0E0 1 2.0E3 1 0.0E0 l 3.6E3 l 4.3E2 1 7.6E6 I l Co-57 I 0.0E0 l 0.'0E0 l 0.0E0 l 1.2E4 l 0.0E0 l 2.1E4 l 1.7E2 l 1.9E6 l l Co-58 l 0.0E0 1 0.0E0 l 0.0E0 1 2.5E4 l 0.0E0 1 5.0E4 I 5.9E2 l 2.2E6 l l Co-60 1 0.0E0 l 0.0E0 1 0.0E0 l 9.4E4 l 0.0E0 i 1.9ES l 1.6E3 1 1.2E8 l l Sr-89 l 0.0E0 1 0.0E0 i 0.0E0 1 1.3E5 l 0.0E0 1 6.7E4 l 1.7E3 1 8.0E4 I I Sr-90 l 0.0E0 1 0.0E0 1 0.0E0 l 2.7E6 l 0.0E0 l 2.1E6 1 5.5E5 l 3.2E6 l l Zr-95 l 0.0E0 1 0.0E0 l 0.0E0 l 1.6E5 l 0.0E0 l 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 l 6.0E5 l 0.0E0 l 1.2E6 1 5.7E2 l 2.9E6 l l Te-129m l 0.0E0 1 0.0E0 l 0.0E0 l 1.5E6 l 0.0E0 l 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 1 0.0E0 l 0.0E0 l 0.0E0 l 3.7E5 1 0.0E0 1 3.0E5 1 4.7E3 l 3.8E7 l ( l Cs-136 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 l 0.0E0 l 1.1E4 l 8.1E2 l 8.4E5 l l Cs-137 1 0.0E0 1 0.0E0 l 0.0E0 l 3.2E5 1 0.0E0 l 2.4E5 1 3.4E3 i 5.7E7 l l Ba-140 l 0.0E0 l 0.0E0 1 0.0E0 l 1.3E4 l 0.0E0 1 1.1E4 l 1.2E3 l 1.3E5 l l Ce-141 l 0.0E0 l 0.0E0 l 0.0E0 1 3.8E3 1 0.0E0 1 6.1E3 1 6.6E2 l 8.5E4 l l Ce-144 1 0.0E0 1 0.0E0 l 0.0E0 l 4.6E4 l 0.0E0 1 7.6E4 l 4.5E3 1 5.0E5 l l I -131 1 0.0E0 l 0.0E0 l 0.0E0 1 1.7E6 1 0.0E0 1 1.1E6 i 6.6E4 l 1.6E6 l l I -133 l 0.0E0 l 0.0E0 l 0.0E0 l 4.0E-2 l 0.0E0 1 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 l 0.0E0 1 0.0E0 l 0.0E0 l 2.8E-181 0.0E0 l 1.6E-18l 2.5E3 l 1.4E4 l l UN-IO l 0.0E0 1 0.0E0 l 0.0E0 l 2.8E5 l l 2.4E5 I 5.7E2 1 4.4E6 l I,0.0E0 l l I I I I I f I l 1 l l l l 1 l l 1 I I I I I I i l l I l l 1 I I I I I I I I I I I I I I I I I I I I l I l l l l l l 1 I I I I I I l I l 1 I l l 1 I I I I I I I I I I I I l l 1 1 I I I I I I I I I I I. 1 I I I I I I I I I I I I I l i I l Inhalation Pathway, units = C APPROVED Food & Ground Pathway, units = MAR 171986 j c 2-46 Rev. 18 03-19-86

TABLE 2-9 (- DOSE PARAMETER R FOR SECTOR B y Page 2 of 2 l Pathway = Sanitary Landfill Distance = 2.1 miles l l X/Q = 1.4E-7 sec/m' 0/Q = 1.2E-9 m 2 l l Infant l Child l Teen l Adult l l l i i i 4 l lInhala-l Food & lInhala-l Food & IInhala-1 Food & IInhala-l Food & I l Radio-ltion l Ground Ition l Ground ltion l Ground (tion l Ground l lNuclide iPathwayl Pathway l Pathway lPathwaylPathwaylPathwaylPathwaylPathwayj i i l i i i i i i i l H -3 I 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 2.9E2 1 0.0E0 [ l Cr-51 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 7.6E2 l 1.1E6 l l Mn-54 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 1.8E4 l 3.2E8 l Co-57 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 7.2E3 1 7.8E7 l l Co-58 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 2.4E4 l 8.7E7 l l Co-60 l 0.0E0 1 0.0E0 1 0.0E0 [ 0.0E0 1 0.0E0 l 0.0E0 l 6.5E4 1 4.9E9 Sr-89 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 i 0.0E0 l 6.9E4 1 4.9E3 l l Sr-90 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.3E7 l 0.0E0 l l Zr-95 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 3.4E4 l 5.7E7 l l Nb-95 l 0.0E0 l 0.0E0 i 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 2.4E4 l 3.1E7 i l Te-129m I 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 8.3E3 1 4.5E6 i Cs-134 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.9E5 l 1.6E9 l Cs-136 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 3.3E4 1 3.4E7 l l i Cs-137-l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.4E5 l 2.3E9 i l Ba-140 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 5.0E4 l 4.7E6 1 ) l Ce-141 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 2.7E4 l 3.1E6 l l Ce-144 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.9E5 1 1.6E7 i l I -131 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 2.7E6 1 3.9E6 l I -13'3 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E6 l 4.9ES l 5.6E5 l l I -135 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 1.0E5 1 5.8E5 l l UN-10 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 1 0.0E0 l 2.4E4 l 1.7E8 l I,0.0E0 l 1 I i l I i i I i l l l l l l l l l l l I I I I I I I l l l 1 1 I I l l l 1 1 1 1 1 I I I l l 1 l l l 1 1 I I I I I I l l 1 I I I I I l l l 1 I I I i 1 I I I I I l l l l l I i 1 1 I I I I I l l 1 I I I I I i l I I I I I I I I Inhalation Pathway, units = h" Food & Ground Pathway, units = AP. PROVED c t1AR 171986 2-47 Rev. 18 03-19-86

TABLE 2-10 ( DOSE PARAMETER R FOR SECTOR C y Page 1 of 4 l Pathway = Sheep (Meat) and Shepherd Distance = 0.2 miles l l X/Q = 6.5E-6 sec/m' D/Q = 5.3E-8 m 2 l l Infant l Child l Teen l Adult l Inhala-l Food & Inhala-l Food & lInhala-l Food & lInhala-l Food & l Radio-l tion l Ground Ition l Ground ltion l Ground Ition l Ground l lNuclide l Pathway lPathwaylPathwaylPathwaylPathwaylPathwaylPathwayl Pathway l l I i l i i i i i i l H -3 l 0.0E0 l 0.0E0 l 0.0E0 1 2.3E2 1 0.0E0 1 1.9E2 l 7.0E0 1 3.2E2 l l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 l 1.3E2 1 0.0E0 1 2.6E2 l 1.8E1 1 2.6E4 l l Mn-54 1 0.0E0 1 0.0E0 1 0.0E0 1 2.0E3 1 0.0E0 l 3.6E3 l 4.3E2 1 7.6E6 l l Co-57 1 0.0E0 l 0.0E0 l 0.0E0 l 1.2E4 1 0.0E0 1 2.1E4 l 1.7E2 l 1.9E6 l l Co-58 l 0.0E0 1 0.0E0 1 0.0E0 1 2.5E4 l 0.0E0 1 5.0E4 l 5.9E2 l 2.2E6 l l Co-60 l 0.0E0 l 0.0E0 1 0.0E0 I 9.4E4 1 0,0E0 1 1.9E5 l 1.6E3 l 1.2E8 l l Sr-89 l 0.0E0 1 0.0E0 1 0.0E0 1 1.3E5 l 0.0E0 l 6.7E4 l 1.7E3 1 8.0E4 l l Sr-90 1 0.0E0 1 0.0E0 1 0.0E0 l 2.7E6 1 0.0E0 l 2.1E6 l 5.5E5 i 3.2E6 l l Zr-95 l 0.0E0 l 0.0E0 l 0.0E0 l 1.6E5 l 0.0E0 1 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 1 0.0E0 1 0.0E0 l 0.0E0 1 6.0E5 1 0.0E0 1 1.2E6 1 5.7E2 l 2.9E6 l l Te-129m I 0.0E0 l 0.0E0 l 0.0E0 l 1.5E6 1 0.0E0 l 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 l 0.0E0 1 0.0E0 1 0.0E0 1 3.7E5 l 0.0E0 l 3.0E5 l 4.7E3 1 3.8E7 i l Cs-136 1 0.0E0 l 0.0E0 1 0.0E0 l 1.3E4 l 0.0E0 l 1.1E4 I 8.1E2 I 8.4E5 I ( l Cs-137 l 0.0E0 1 0.0E0 l 0.0E0 1 3.2E5 1 0.0E0 1 2.4E5 l 3.4E3 l 5.7E7 l l Ba-140 1 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 l 0.0E0 l 1.1E4 l 1.2E3 l 1.3E5 l ) I Ce-141 1 0.0E0 1 0.0E0 1 0.0E0 l 3.8E3 1 0.0E0 l 6.1E3 1 6.6E2 I 8.5E4 l l Ce-144 1 0.0E0 l 0.0E0 1 0.0E0 l 4.6E4 1 0.0E0 1 7.6E4 l 4.5E3 1 5.0E5 l l I -131 1 0.0E0 l 0.0E0 l 0.0E0 l 1.7E6 l 0.0E0 1 1.1E6 i 6.6E4 l 1.6E6 l l I -133 l 0.0E0 1 0.0E0 l 0.0E0 1 4.0E-2 1 0.0E0 l 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 1 0.0E0 l 0.0E0 1 0.0E0 l 2.8E-18l 0.0E0 1 1.6E-181 2.5E3 l 1.4E4 l l UN-ID l 0.0E0 1 0.0E0 1 0.0E0 l 2.8E5 1 0.0E0 l 2.4E5 l 5.7E2 1 4.4E6 l l l l l l f' I i l i I I l I I I l l l l 1 1 I I I I I l 1 1 I I I I i l l l l l 1 I I i l I i l i I I I I I I I I I I I I I I I I l l 1 l l l I I I I I I I I I l l l l l 1 I I I I I l I I I l 1 I I I I I I I I I I I I l l 1 I I I I I I l l I I Inhalation Pathway, units = [ h " Food & Ground Pathway, units = (* "I APPROYED f MAR 171986 2-48 Rev. 18 03-19-86

TABLE 2-10 ( DOSE PARAMETER R FOR SECTOR C g Page 2 of 4 l Pathway = Camp San Onofre Distance = 2.6 miles l l X/Q = 9.2E-8 sec/m: D/Q = 8.4E-10 m 2 l l l Infant l Child l Teen l Adult l Inhala-l Food & Inhala-l Food & IInhala-1 Food & Inhala-l Food & l Radio-l tion l Ground ltion l Ground l tion l Ground l tion l Ground l lNuclide IPathwaylPathwayjPathwaylPathwaylPathwaylPathwaylPathwaylPathwayl i i i i i l i i i i l H -3 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 1.3E3 0.0E0 l l Cr-51 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 3.3E3 3.7E6 I l Mn-54 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 7.7E4 1.1E9 l l Co-57 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 3.1E4 2.7E8 l l Co-58 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.1ES l 3.0E8 l l Co-60 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0.{ 0.0E0 l 0.0E0 l 2.8E5 l 1.7E10 l l Sr-89 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 3.0E5 l 1.7E4 l l Sr-90 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 9.9E7 l 0.0E0 l l Zr-95 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.5E5 1 2.0E8 l l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 1.0E5 i 1.1E8 l l Te-129m l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 3.7E4 l 1.6E7 l l Cs-134 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 8.5ES I 5.5E9 l l Cs-136 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 1.5E5 l 1.2E8 l I l Cs-137-l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 6.2E5 I 8.2E9 i l Ba-140 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 2.2E5 l 1.6E7 I l Ce-141 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 1.2E5 l 1.1E7 l l Ce-144 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 8.2E5 l 5.6E7 l l 1 -131 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.2E7 l 1.4E7 l l I -133 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 2.2E6 [ 2.0E6 l l I -135 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 4.5E5 l 2.0E6 l l UN-ID l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.0E5 1 6.0E8 l l l l l l (" I I I I I i l 1 l l I I I I I i l l 1 I l l l l l l 1 I I I i 1 I I I I I I I l 1 I I I I I I I I I I I i l I I I l l 1 I I I I I I I I I i l I i I l l 1 i l I l i i i I I I l 1 I I I I l l i I I I I I I I i l i I i i l l Inhalation Pathway, units = h" Food & Ground Pathway units = I* "I f APPROVED MAR 171986 2-49 Rev. 18 03-19-86

i TABLE 2-10 i ( DOSE PARAMETER R; FOR SECTOR C Page 3 of 4 l Pathway = Camp San Onofre Fr. Stn Distance = 2.3 miles l X/Q = 1.1E-7 sec/m' D/Q = 1.1E-9 m

  • l l

Infant l Child l Teen l Adult l Inhala-l Food & Inhala-l Food & Inhala-Food &lInhala-l Food & l Radio-l tion l Ground l tion l Ground l tion l Ground (tion i Ground l lNuclide l Pathway lPathwaylPathwayl Pathway l Pathway l Pathway l Pathway l Pathway l l l l l l l l l l l l H -3 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.6E2 1 0.0E0 l l Cr-51 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 9.5E2 l 1.3E6 l l Mn-54 l 0.0E0 1 0.0E0 l 0.0E0 l 0.M0 l 0.0E0 l 0.0E0 1 2.2E4 l 3.9E8 l l Co-57 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 9.0E3 1 9.8E7 l l Co-58 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 ' 3.0E4 l 1.1E8 i Co-60 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0.1 0.0E0 1 0.0E0 8.1E4 l 6.1E9 l Sr-89 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 [ 0.0E0 l 8.7E4 1 6.2E3 l l Sr-90 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 2.8E7 l 0.0E0 l l Zr-95 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 ! 4.3E4 I 7.2E7 l l Nb-95 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 3.0E4 1 3.9E7 l l Te-129m l 0.0E0 } 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.0E4 l 5.6E6 l l Cs-134 l 0.0E0 l 0.0E0 1 0.0E0 1 0.G20 l 0.0E0 1 0.0E0 l 2.4E5 l 1.9E9 I l Cs-136 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 4.2E4 l 4.3E7 l \\ l Cs-137 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.8E5 1 2.9E9 l l Ba-140 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 6.2E4 l 5.9E6 l ) l Ce-141 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 3.4E4 l 3.9E6 l l Ce-144 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 2.3E5 1 2.0E7 l l I -131 1 0.0E0 1 0.0E0 i 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.4E6 l 4.9E6 l l I -153 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 6.lES I 7.0E5 l l I -135 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.3E5 l 7.2E5 l l UN-ID 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 2.9E4 1 2.1E8 I I I I I I l" l 1 I I I I i 1 1 I I l 1 1 I I I I l 1 l 1 1 I I I I i l 1 I l l l l l l l I I I l l 1 1 I i l l l l 1 l I I l I l 1 I l l l l I I l l l 1 l l l 1 I l l l 1 l l l l l 1 1 I I I I I I I I I I I I I I I l l 1 i I I i l I Inhalation Pathway, units = 2 Food & Ground Pathway, units = L*JL***") APPROVED MAR 17 Wd6 ?-50 Rev. 18 03-19-86

TABLE 2-10 ( DOSE PARAMETER R; FOR SECTOR C Page 4 of 4 I l Pathway = Sewage Facility Distance = 2.2 miles l l X/Q = 1.2E-7 sec/m 2 0/Q.= 1.2E-9 m 2 l l l Infant l Child l Teen l Adult lInhala-l Food & Inhala-l Food & Inhala-l Food & Inhala-l Food & IRadio-l tion l Ground l tion I Ground Ition l Ground Itfon l Ground l lNuclide l Pathway l Pathway l Pathway l PathwaylPathway l Pathway l Pathway l Pathway 1 l l l l l l l l l l l 1 I I I i l H -3 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 2.9E2 0.0E0 l l Cr-51 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 I 7.6E2 l 1.1E6 i Mn-54 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.8E4 1 3.2E8 i Co-57 1 0.0E0 1 0.0E0 l 0.0E0 0.0E0 l 0.0E0 1 0.0E0 1 7.2E3 I 7.8E7 I l Co-58 l 0.0E0 1 0.0E0 1 0.0E0 ,l 0.0E0,1 0.0E0 1 0.0E0 I 6.5E4 l 4.9E9 l 0.0E0 1 0.0E0 1 0.0E0 l 2.4E4 l 8.7E7 i l Co-60 l 0.0E0 l 0.0E0 l 0.0E0 l Sr-89 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 6.9E4 I 4.9E3 I l Sr-90 l 0.0E0 l 0.0E0 I b.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 2.3E7 1 0.0E0 l l Zr-95 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 3.4E4 l 5.7E7 l 1 Nb-95 I 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 2.4E4 1 3.1E7 l l Te-129m l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 8.3E3 1 4.5E6 l l Cs-134 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.9E5 l 1.6E9 1 l Cs-136 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 I 3.3E4 i 3.4E7 l l I Cs-137 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.4E5 1 2.3E9 l l Ba-140 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 5.0E4 l 4.7E6 I l Ce-141 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 2.7E4 1 3.1E6 l Ce-144 I 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 1.9ES l 1.6E7 I I -131 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 2.7E6 l 3.9E6 l l I -133 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 4.9E5 I 5.6E5 I l I -135 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 i 1.0E5 1 5.8E5 I I UN-ID I 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 2.4E4 l 1.7E8 l l l 1 l 1 l~ l l I I I I I I I I I I I I I I I I i i l I l 1 1 I I I I I I l l 1 I I I l l l l l l 1 1 I I I I I I l l l i I I I I I I I I I I i l l l l l l 1 1 I I I I I I I I I I l l 1 i l l I l 1 l 1 I I I I I I I I I I I I I i l l l Inhalation Pathway, units = Food & Ground Pathway, units = uc usec APPROVED MAR 171986 2-51 Rev. 18 03-19-86

TABLE 2-11 ( DOSE PARAMETER R FOR SECTOR D g Page 1 of 2 l Pathway = Sheep (Meat)andShepherd Distance = 0.2 miles l l X/Q = 6.3E-6 sec/m' D/Q = 6.6E-8 m 2 l l l Infant l Child l Teen l Adult l l l l i i i I IInhala-l Food & IInhala-l Food & IInhala-1 Food & lInhala-l Food & ! 1 Radio- [ tion l Ground l tion i Ground ltion I Ground Ition l Ground ! INuclide l Pathway l Pathway l Pathway l PathwaylPathway l PathwaylPathway l Pathway l l l i i i i i i i i I H -3 l 0.0E0 1 0.0E0 1 0.0E0 l 2.3E2 l 0.0E0 l 1.9E2 1 7.0E0 1 3.2E2 l l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 1 1.3E2 1 0.0E0 l 2.6E2 l 1.8E1 l 2.6E4 l l Mn-54 1 0.0E0 l 0.0E0 1 0.0E0 l 2.0E3 1 0.0E0 l 3.6E3 l 4.3E2 1 7.6E6 l l Co-57 l 0.0E0 1 0.0E0 1 0.0E0 l 1.2E4 l 0.0E0 1 2.1E4 l 1.7E2 l 1.9E6 [ l Co-58 1 0.0E0 1 0.0E0 1 0.0E0 l 2.5E4 1 0.0E0 1 5.0E4 l 5.9E2 l 2.2E6 I I Co-60 l 0.0E0 l 0.0E0 l 0.0E0 l 9.4E4 1 0.0E0 1 1.9ES l 1.6E3 l 1.2E8 l l Sr-89 l 0.0E0 1 0.0E0 1 0.0E0 l 1.3E5 1 0.0E0 1 6.7E4 1 1.7E3 I 8.0E4 I I Sr-90 1 0.0E0 l 0.0E0 i 0.0E0 l 2.7E6 l 0.0E0 l 2.1E6 I 5.5E5 l 3.2E6 I l Zr-95 l 0.0E0 1 0.0E0 1 0.0E0 l 1.6E5 1 0.0E0 1 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 l 0.0E0 1 0.0E0 l 6.0E5 1 0.0E0 l 1.2E6 i 5.7E2 l 2.9E6 l l Te-129m I 0.0E0 l 0.0E0 1 0.0E0 1 1.5E6 1 0.0E0 1 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 l 0.0E0 1 0.0E0 l 0.0E0 l 3.7E5 1 0.0E0 l 3.0E5 l 4.7E3 l 3.8E7 l 1 Cs-136 l 0.0E0 1 0.0E0 l 0.0E0 1 1.3E4 l 0.0E0 1 1.1E4 l 8.1E2 1 8.4E5 l ( l Cs-137 1 0.0E0 1 0.0E0 l 0.0E0 l 3.2E5 1 0.0E0 l 2.4E5 ! 3.4E3 l 5.7E7 l l Ba-140 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 l 0.0E0 1 1.1E4 ! 1.2E3 l 1.3E5 I l Ce-141 1 0.0E0 l 0.0E0 1 0.0E0 l 3.8E3 l 0.0E0 l 6.1E3 l 6.6E2 l 8.5E4 I I Ce-144 1 0.0E0 l 0.0E0 1 0.0E0 l 4.6E4 I 0.0E0 l 7.6E4 1 4.5E' l 5.0E5 l l I -131 1 0.0E0 1 0.0E0 1 0.0E0 l 1.7E6 1 0.0E0 l 1.1E6 l 6.6E4 l 1.6E6 l l I -133 l 0.0E0 l 0.0E0 l 0.0E0 l 4.0E-2 l 0.0E0 1 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 I 0.0E0 l 0.0E0 1 0.0E0 l 2.8E-18l 0.0E0 l 1.6E-18i 2.5E3 l 1.4E4 i I UN-ID l 0.0E0 1 0.0E0 l 0.0E0 l 2.8E5 l 0.0E0 l 2.4E5 l 5.7E2 l 4.4E6 l l l 1 I l r' l l J l l 1 1 I I I I I I i l l l l l 1 I I I I I I I I I I I I I I I I I I I I i l l l l l I I i I i l i I I I I I I l l l l i l I I l l l 1 1 I I I l l l l l l 1 1 1 1 I I I I l l l l l l l l I I I I i i l l 1 1-1 I I I i i I l Inhalation Pathway, units = h" Food & Ground Pathway, units = APPROVED / MAR 171986 2-52 Rev. 18 03-19-86

TABLE 2-11 ( DOSE PARAMETER R; FOR SECTOR D Page 2 of 2 iPathway=CampSanOnofre Distance = 2.8 miles l l X/Q = 6.6E-8 sec/m' 0/Q = 6.4E-10 m 2 l l Infant I Child l Teen f Adult 1 lInhala-l Food &IInhala-l Food &lInhala-l Food &lInhala-l Food &l IRadio-Ition l Ground l tion l Ground ltion l Ground ition l Ground ! lNuclide l Pathway lPathwaylPathwaylPathwayjPathwaylPathwaylPathwayl Pathway l l l i i i i i i i i l H -3 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 1.3E3 1 0.0E0 1 Cr-51 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.3E3 l 3.7E6 l l Mn-54 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 7.7E4 l 1.1E9 l 1 Co-57 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 3.1E4. I 2.7E8 l l Co-58 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 1.1E5 l 3.0E8 i l Co-60 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 2.8E5 l 1.7E10 ! I Sr-89 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 3.0E5 l 1.7E4 l l Sr-90 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 9.9E7 1 0.0E0 l l Zr-95 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.5E5 l 2.0E8 i Nb-95 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.0E5 l 1.1E8 i Te-129m l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 3.7E4 l 1.6E7 l i Cs-134 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 8.5ES I 5.5E9 l Cs-136 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 1.5E5 l 1.2E8 l ( l Cs-137 l 0.0E0 l 0.0E0 ! 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 6.2E5 l 8.2E9l Ba-140 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 i 0.0E0 l 2.2E5 l 1.6E7 i ) [ Ce-141 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.2E5 l 1.1E7 l l Ce-144 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 8.2E5 l 5.6E7 l l I -131 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 1.2E7 l 1.4E7 l 1 I -1Y3 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 2.2E6 l 2.0E6 l l I -135 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 4.5E5 l 2.0E6 l l UN-ID l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 1.0E5 l 6.0E8 l 1 1 I l 1 I" l I I I I I I I I l l l 1 I I I I I I I I i l l l l l I I I I I I I I I i l l l l l 1 I I I I I I I I l l l l l 1 I I l l 1 I I I I I I l l I I i i i l l l l l l l l l l 1 1 I I I l l l 1 l l l i i l l i l l I I I I I l l I I I I l I Inhalation Pathway, units = Food & Ground Pathway, units = (* ") APPROV$D / c 11AR 171986 2-53 Rev. 18 03-19-86

TABLE 2-12 ( DOSE PARAMETER R; FOR SECTOR E Page 1 of 2 l Pathway = Sheep (Meat)andShepherd Distance = 0.3 miles l l X/Q = 4.5E-6 sec/m' D/Q = 5.9E-8 m 2 l l l Infant l Child l Teen l Adult l lInhala-1 Food & lInhala-l Food & lInhala-l Food &Inhala-l Food &l l Radio-l tion l Ground ltion i Ground ltion l Ground ' tion l Ground l lNuclide l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway Pathway l Pathwayl l I l l l l l l l l l H -3 1 0.0E0 l 0.0E0 1 0.0E0 l 2.3E2 l 0.0E0 l 1.9E2 l 7.0E0 1 3.2E2 l Cr-51 l 0.0E0 1 0.0E0 1 0.0E0 1 1.3E2 l 0.0E0 l 2.6E2 l 1.8E1 l 2.6E4 l Mn-54 l 0.0E0 l 0.0E0 l 0.0E0 l 2.0E3 1 0.0E0 1 3.6E3 l 4.3E2 1 7.6E6 l Co-57 l 0.0E0 l 0.0E0 l 0.0E0 l 1.2E4 1 0.0E0 l 2.1E4 l 1.7E2 l 1.9E6 l Co-58 l 0.0E0 l 0.0E0 l 0.0E0 l 2.5E4 1 0.0E0 1 5.0E4 l 5.9E2 l 2.2E6. l l Co-60 l 0.0E0 l 0.0E0 1 0.0E0 l 9.4E4 l 0.0E0 l 1.9E5 l 1.6E3 l 1.2E8 l l Sr-89 l 0.0E0 l 0.0E0 1 0.0E0 1 1.3E5 l 0.0E0 1 6.7E4 l 1.7E3 l 8.0E4 l l Sr-90 l 0.0E0 1 0.0E0 l 0.0E0 1 2.7E6 l 0.0E0 l 2.1E6 l 5.5E5 l 3.2E6 l l Zr-95 1 0.0E0 l 0.0E0 l 0.0E0 l 1.6ES l 0.0E0 1 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 l 0.0E0 l 0.0E0 l 6.0E5 1 0.0E0 l 1.2E6 1 5.7E2 l 2.9E6 l Te-129m I 0.0E0 l 0.0E0 l 0.0E0 l 1.5E6 l 0.0E0 l 1.2E6 l 2.0E2 l 1.5E6 l Cs-134 l 0.0E0 l 0.0E0 1 0.0E0 l 3.7ES l 0.0E0 l 3.0E5 1 4.7E3 1 3.8E7 l l Cs-136 0.0E0 l 0.0E0 1 0.0E0 l 1.3E4 l 0.0E0 l 1.1E4 l 8.1E2 l 8.4E5 l ( l Cs-137 l 0.0E0 l 0.0E0 1 0.0E0 l 3.2E5 l 0.0E0 l 2.4E5 l 3.4E3 1 5.7E7 l l Ba-140 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 1 0.0E0 1 1.1E4 l 1.2E3 l 1.3E5 l ) Ce-141 1 0.0E0 l 0.0E0 l 0.0E0 1 3.8E3 1 0.0E0 l 6.1E3 1 6.6E2 l 8.5E4 l Ce-144 l 0.0E0 1 0.0E0 1 0.0E0 l 4.6E4 l 0.0E0 l 7.6E4 l 4.5E3 l 5.0E5 l I -131 1 0.0E0 l 0.0E0 1 0.0E0 l 1.7E6 1 0.0E0 l 1.1E6 l 6.6E4 l 1.6E6 i i I -133 1 0.0E0 0.0E0 1 0.0E0 l 4.0E-2 l 0.0E0 1 2.2E-2 l 1.2E4 l 1.3E4 [ I -135 l 0.0E0 0.0E0 l 0.0E0 l 2.8E-181 0.0E0 l 1.6E-18l 2.5E3 l 1.4E4 l UN-ID l 0.0E0 l 0.0E0 1 0.0E0 l 2.8E5 1 0.0E0 l 2.4E5 1 5.7E2 l 4.4E6 L i l l l l r I I l I l l 1 l l I l l l l l l 1 I I l l l l l 1 1 I I l l l l l 1 l l 1 l l l l 1 I l l l l l l l l l l 1 I I I I l l l l l l 1 I I I I l 1 I I I I i I l l l l l 1 I I l 1 l l l l l l l l l l l 1 l l l l l l 1 l I l I Inhalation Pathway, units = C Food & Ground Pathway, units = c APPROVED MAR 171986 2-54 Rev. 18 03-19-86

TABLE 2-12 ~ ( DOSE PARAMETER R; FOR SECTOR E Page 2 of 2 i Pathway = Camp Horno Distance = 4.0 miles l l X/Q = 6.6E-8 sec/m' D/Q = 6.4E-10 m 2 l l i i i + l l Infant I Child Teen Adult l l lInhala-l Food & IInhala-l Food & LInhala-l Food & lInhala-l Food & l Radio-l tion l Ground l tion l Ground Ition l Ground l tion l Ground l lNuclide (Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway 1 l l l l l l l l l l .l H -3 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 1.3E3 1 0.0E0 l l Cr-51 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 3.3E3 l 3.7E6 l l Mn-54 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 7.7E4 l 1.1E9 l' Co-57 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 3.1E4 l 2.7E8 l l Co-58 1 0.0E0 l 0.0E0 l 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 1.1E5 l 3.0E8 i l Co-60 l 0.0E0 l 0.0E0 l 0.0E0 0.0E0 1 0.0E0 l 0.0E0 1 2.8E5 l 1.7E10 l Sr-89 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 3.0E5 l 1.7E4 Sr-90 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 9.9E7 i 0.0E0 l Zr-95 l~0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1.5E5 1 2.0E8 l l Nb-95 1 0.0E0 j 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1.0E5 l 1.1E8 l l Te-129m l 0.0E0 ' O.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 3.7E4 l 1.6E7 l l Cs-134 l 0.0E0 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 8.5E5 l 5.5E9 l Cs-136 l 0.0E0 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 1.5E5 l 1.2E8 l ( Cs-137 l 0.0E0 L 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 6.2E5 l 8.2E9 l [ Ba-140 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 2.2E5 l 1.6E7 l l Ce-141 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 1.2E5 l 1.1E7 l l Ce-144 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 8.2E5 l 5.6E7 l l I -131 1 0.0E0 l 0.0E0 [ 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 1.2E7 l 1.4E7 l l I -133 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.2E6 l 2.0E6 l l I -135 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 4.5E5 l 2.0E6 l 1 UN-ID l 0.0E0 l 0.0E0 1 0.0E0 0.0E0 1 0.0E0 l 0.0E0 l 1.0E5 l 6.0E8 l l 1 1 I l~ ~ l J I l l l 1 L I l l l l l l l l l l l l l l l l l l l 1 I I l l l 1 I I l l l l 1 l 1 I I I I I I I i l I l l l l 1 I I I I I I I I I I I I I I I I l I l l 1 I I l l l l l l 1 1 I I I I l l l 1 I i 1 I I I I I i l l I I I Inhalation Pathway, units = "C Food & Ground Pathway, units = MAR 17 BB6 2-55 Rev. 18 03-19-86

TABLE 2-13 -t DOSE PARAMETER R FOR SECTOR F g Page 1 of 2 i l Pathway = Sheep (Meat) and Shepherd Distance = 0.5 miles l l X/Q = 1.8E-6 sec/m8 D/Q = 1.7E-8 m 2 l l Infant l Child i Teen Adult l l I l s s l IInhala-l Food & lInhala- ! Food & lInhala-l Food & lInhal - l Food & ! l Radio-l tion l Ground l tion l Ground ltion l Ground Ition l Ground i [Nuclide l Pathway lPathwaylPathwaylPathwaylPathwayl Pathway l Pathway l Pathway l l l i i i i i i i i l H -3 1 0.0E0 l 0.0E0 1 0.0E0 1 2.3E2 l 0.0E0 1 1.9E2 1 7.0E0 1 3.2E2 l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 l 1.3E2 1 0.0E0 l 2.6E2 l 1.8E1 1 2.6E4 l l Mn-54 l 0.0E0 l 0.0E0 1 0.0E0 l 2.0E3 1 0.0E0 l 3.6E3 l 4.3E2 l 7.6E6 l l Co-57 1 0.0E0 1 0.0E0 1 0.0E0 l 1.2E4 l 0.0E0 l 2.1E4 l 1.7E2 l 1.9E6 l l Co-58 , 0.0E0 1 0.0E0 1 0.0E0 l 2.5E4 l 0.0E0 1 5.0E4 l 5.9E2 l 2.2E6 l l Co-60 0.0E0 l 0.0E0 1 0.0E0 l 9.4E4 l 0.0E0 1 1.9ES l 1.6E3 l 1.2E8 l l Sr-89 0.0E0 1 0.0E0 l 0.0E0 l 1.3E5 1 0.0E0 l 6.7E4 l 1.7E3 l 8.0E4 l l Sr-90 0.0E0 1 0.0E0 1 0.0E0 l 2.7E6 l 0.0E0 l 2.1E6 1 5.5ES I 3.2E6 i l Zr-95 l 0.0E0 l 0.0E0 1 0.0E0 l 1.6ES 0.0E0 l 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 l 0.0E0 1 0.0E0 l 6.0E5 0.0E0 1 1.2E6 l 5.7E2 l 2.9E6 i l Te-129m l 0.0E0 1 0.0E0 l 0.0E0 l 1.5E6 l 0.0E0 l 1.2E6 1 2.0E2 1 1.5E6 l l Cs-134 l 0.0E0 1 0.0E0 l 0.0E0 l 3.7ES I 0.0E0 l 3.0E5 1 4.7E3 I 3.8E7 l l Cs-136 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 l 0.0E0 1 1.1E4 i 8.1E2 I 8.4E5 l ( l Cs-137 l 0.0E0 1 0.0E0 1 0.0E0 l 3.2E5 1 0.0E0 ! 2.4E5 l 3.4E3 l 5.7E7 i l Ba-140 l 0.0E0 l 0.0E0 1 0.0E0 l 1.3E4 1 0.0E0 l 1.1E4 l 1.2E3 l 1.3E5 I l Ce-141 l 0.0E0 l 0.0E0 l 0.0E0 l 3.8E3 l 0.0E0 1 6.1E3 1 6.6E2 l 8.5E4 1 l Ce-144 l 0.0E0 l 0.0E0 1 0.0E0 l 4.6E4 l 0.0E0 l 7.6E4 l 4.5E3 l 5.0E5 l l I -131 1 0.0E0 1 0.0E0 l 0.0E0 1 1.7E6 l 0.0E0 l 1.1E6 1 6.6E4 l 1.6E6 l l I -133 1 0.0E0 1 0.0E0 1 0.0E0 l 4.0E-2 l 0.0E0 1 2.2E-2 1 1.2E4 l 1.3E4 l l I -135 1 0.0E0 l 0.0E0 l 0.0E0 l 2.8E-181 0.0E0 l 1.6E-181 2.5E3 l 1.4E4 l UN-ID l 0.0E0 1 0.0E0 1 0.0E0 l 2.8E5 1 0.0E0 1 2.4E5 5.7E2 l 4.4E6 l l l l l F l .l l l l l l l 1 l l 11 l 1 I l l l 1 1 I I l l l l l l l l l l I I I I I I I I l 1 l l l l l l l l l I I I I I I l l l l 1 l 1 l l I I l 1 l l l l l l l l l 1 I I I I i l l l l l l l l l 1 l l l l 1 I I I I I I I l l I InhalationPathway, units =h] Food & Ground Pathway, units = / APPROVED MAR 171986 2-56 Rev. 18 03-19-86

TABLE 2-13 ( DOSE PARAMETER R FOR SECTOR F g Page 2 of 2 l Pathway =SanOnofreStateParkGuardShack Distance = 0.8 miles l l X/Q = 8.1E-7 sec/m' 0/Q = 7.1E-9 m 2 1 l Infant I Child l Teen l Adult Inhala-l Food & Inhala-l Food & Inhala-l Food & Inhala-l Food & Radio-l tion l Ground ltion l Ground l tion I Ground [ tion l Ground ! lNuclide IPathway l Pathway l Pathway l PathwaylPathway l PathwaylPathway l Pathway l l i i i i i i i i i H -3 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 2.9E2 1 0.0E0 l Cr-51 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 7.6E2 l 1.1E6 1 Mn-54 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 1.8E4 1 3.2E8 l l Co-57 l 0.0E0 ! 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 7.2E3 1 7.8E7 l l Co-58 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 2.4E4 I 8.7E7 i i Co-60 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 6.5E4 l 4.9E9 l Sr-89 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 6.9E4 l 4.9E3 l l Sr-90 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 2.3E7 1 0.0E0 l l Zr-95 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 3.4E4 l 5.7E7 i l l Nb-95 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 2.4E4 1 3.1E7 I l Te-129m 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 8.3E3 l 4.5E6 l l Cs-134 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 1.9E5 l 1.6E9 l f l Cs-136 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 3.3E4 1 3.4E7 l \\ l Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 1.4E5 l 2.3E9 l Ba-140 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 5.0E4 1 4.7E6 Ce-141 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.7E4 l 3.1E6 i Ce-144 I 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0

0.0E0 1 1.9E5 l 1.6E7 I i

I -131 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 2.7E6 I 3.9E6 l l I -133 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 4.9E5 l 5.6E5 l l I -135 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 1.0E5 l 5.8E5 I I UN-ID 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 2.4E4 l 1.7E8 l I l l r' I I i I L i i l i l i I I L I I I I I I i l l l l l l l 1 l l l 1 1 I I I I I I I I I I 1 l l l l i I I i l I I I i l i I I I I I I I I I I I I I I I I I I I I I I I l l 1 1 I I i 1 i I I i I i l l l l l 1 I I I I I I I I I I I InhalationPathway, units =] Food & Ground Fathway, units = U APPROVED MAR 171986 2-57 Rev. 18 03-19-86

TABLE 2-14 DOSE PARAMETER R FOR SECTOR G i, g Page I of 3 l Pathway = San Onofre State Park Beach Campground Distance = 0.8 miles I i l X/Q = 7.7E-7 sec/m' 0/Q = 3.9E-9 m

  • l l

Infant l Child l Teen l Adult l l l l l i l lInhala-l Food & IInhala-l Food & IInhala-l Food & lInhala-l Food & I i l Radio-l tion l Ground Itton l Ground (tion i Ground (tion l Ground l lNuclide IPathway l PathwaylPathway l Pathway l Pathway l PathwaylPathway 1 Pathway! l l l l l l l l l l l H -3 l 8.0E1 l 0.0E0 l 1.4E2 l 0.0E0 l 1.6E2 1 0.0E0 1 1.8E2 1 0.0E0 l I Cr-51 l 4.4E1 l 5.7ES l 1.3E2 1 5.7E5 l 3.7E2 ! 5.7E5 l 4.7E2 l 6.6E5 l l Mn-54 l 3.1E3 l 1.7E8 1 5.3E3 l 1.7E8 l 8.2E3 1 1.7E8 l 1.1E4 l 2.0E8 l l Co-57 l 6.0E2 l 4.2E7 ! 1.6E3 1 4.2E7 [ 3.9E3 1 4.2E7 l 4.5E3 l 4.9E7 l l Co-58 l 1.4E3 l 4.7E7 i 4.2E3 l 4.7E7 l 1.2E4 1 4.7E7 l 1.5 C.4 l 5.4E7 l l Co-60 3.9E3 l 2.7E9 l 1.2E4 l 2.7E9 1 3.2E4 l 2.7E9 l 4.1E4 1 3.1E9 l l Sr-89 4.9E4 l 2.7E3 1 7.4E4 l 2.7E3 l 5.3E4 l 2.7E3 l 4.3E4 l 3.1E3 l l Sr-90 5.0E6 l 0.0E0 1 1.2E7 1 0.0E0 1 1.3E7 1 0.0E0 1 1.4E7 1 0.0E0 l l Zr-95 1 2.7E3 l 3.1E7 l 7.5E3 1 3.1E7 [ 1.8E4 1 3.1E7 l 2.1E4 1 3.6E7 l l Nb-95 l 1.6E3 1 1.7E7 i 4.6E3 l 1.7E7 l 1.2E4 i 1.7E7 l 1.5E4 i 1.9E7 l l Te-129m l 3.9E3 l 2.4E6 l 6.2E3 l 2.4E6 l 6.4E3 l 2.4E6 l 5.2E3 l 2.8E6 l l Cs-134 l 8.7E4 l 8.4E8 l 1.3E5 l 8.4E8 l 1.4E5 l 8.4E8 l 1.2E5 l 9.7E8 l l Cs-136 l 1.7E4 l 1.9E7 l 2.1E4 l 1.9E7 l 2.4E4 l 1.9E7 l 2.1E4 l 2.1E7 l ( l Cs-137 l 7.5E4 l 1.3E9 l 1.0E5 l 1.3E9 l 1.0E5 l 1.3E9 I 8.9E4 1 1.5E9 l l Ba-140 l 6.9E3 l 2.5E6 l 9.1E3 l 2.5E6 l 2.8E4 l 2.5E6 l 3.1E4 l 2.9E6 l I Ce-141 1 2.7E3 l 1.7E6 1 7.0E3 1 1.7E6 l 1.6E4 l 1.7E6 l 1.7E4 l 1.9E6 l l Ce-144 l 1.8E4 l 8.6E6 l 4.8E4 l 8.6E6 l 1.1E5 l 8.6E6 l 1.2E5 j 9.9E6 l l 1 -131 1 1.8E6 l 2.1E6 l 2.0E6 l 2.1E6 l 1.8E6 l 2.1E6 l 1.7E6 i 2.5E6 l l I -133 1 4.4E5 l 3.0E5 1 4.7ES l 3.0E5 l 3.6E5 l 3.0E5 l 3.1E5 l 3.5E5 I I -135 8.6E4 l 3.1E5 l 9.8E4 1 3.1E5 1 7.7E4 1 3.1ES l 6.4E4 I 3.6E5 l UN-ID 7.7E3 l 9.2E7 l 1.4E4 l 9.2E7 l 1.6E4 l 9.2E7 l 1.5E4 l 1.1E8 I I L I i 1 l~ l l l l l l l 1 1 I l l 1 I I I I i l l l l l l l l l l l l 1 l l 1 I I I I I I l 1 I l l l l l 1 I I I I i l l l l l l l l l l i I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I l l I I I I I I I I I l l l l l l l l I I I Inhalation Pathway, units = "C Food & Ground Pathway, units = ]c APPROVED MAR 171986 2-58 Rev. 18 03-19-86

TABLE 2-14 ( DOSE PARAMETER R FOR SECTOR G g Page 2 of 3 l Pathway = Sheep (Meat) and Shepherd Distance = 2.7 miles l l X/Q = 1.2E-7 sec/m' D/Q = 4.8E-10 m 2 l t l l Infant l Child l Teen l Adult l t I l l l l l lInhala-l Food & lInhala-l Food & lInhala-l Food & lInhala-l Food & 1 1 Radio-l tion Ground l tion I Ground ltion l Ground l tion l Ground l INuclide [ Pathway Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l l l l l l l l l l H -3 l 0.0E0 l 0.0E0 l 0.0E0 l 2.3E2 1 0.0E0 l 1.9E2 l 7.0E0 3.2E2 l l Cr-51 l 0.0E0 1 0.0E0 l 0.0E0 l 1.3E2 1 0.0E0 l 2.6E2 l 1.8E1 2.6E4 l l Mn-54 l 0.0E0 1 0.0E0 l 0.0E0 l 2.0E3 l 0.0E0 1 3.6E3 1 4.3E2 7.6E6 l l Co-57 1 0.0E0 l 0.0E0 l 0.0E0 l 1.2E4 1 0.0E0 l 2.1E4 l 1.7E2 1.9E6 l l Co-58 l 0.0E0 1 0.0E0 1 0.0E0 l 2.5E4 1 0.0E0 1 5.0E4 l 5.9E2 { 2.2E6 i ( l Co-60 l 0.0E0 l 0.0E0 1 0.0E0 l 9.4E4 1 0.0E0 l 1.9E5 l 1.6E3 l 1.2E8 l l Sr-89 l 0.0E0 1 0.0E0 l 0.0E0 l 1.3E5 1 0.0E0 1 6.7E4 l 1.7E3 l 8.0E4 l l Sr-30 l 0.0E0 l 0.0E0 1 0.0E0 l 2.7E6 i 0.0E0 l 2.1E6 1 5.5E5 l 3.2E6 l l Zr-95 1 0.0E0 l 0.0E0 1 0.0E0 l 1.6E5 l 0.0E0 l 2.9E5 l 8.3E2 l 1.9E6 l l Nb-95 l 0.0E0 1 0.0E0 1 0.0E0 l 6.0E5 1 0.0E0 l 1.2E6 l 5.7E2 l 2.9E6 l l Te-129m l 0.0E0 l 0.0E0 l 0.0E0 l 1.5E6 1 0.0E0 l 1.2E6 l 2.0E2 l 1.5E6 l l Cs-134 l 0.0E0 1 0.0E0 1 0.0E0 l 3.7ES l 0.0E0 l 3.0E5 1 4.7E3 l 3.8E7 l l Cs-136 l 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 1 0.0E0 l 1.1E4 l 8.1EP l 8.4E5 l ( Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 l 3.2E5 l 0.0E0 1 2.4E5 l 3.4E3 l 5.7E7 l Ba-140 1 0.0E0 l 0.0E0 l 0.0E0 l 1.3E4 l 0.0E0 l 1.1E4 l 1.2E3 l 1.3E5 l t l Ce-141 1 0.0E0 1 0.0E0 1 0.0E0 l 3.8E3 1 0.0E0 l 6.1E3 1 6.6E2 l 8.5E4 l l Ce-144 l 0.0E0 1 0.0E0 l 0.0E0 l 4.6E4 1 0.0E0 l 7.6E4 l 4.5E3 l 5.0E5 l l I -131 1 0.0E0 l 0.0E0 1 0.0E0 l 1.7E6 1 0.0E0 l 1.1E6 l 6.6E4 l 1.6E6 l l 1 -133 l 0.0E0 l 0.0E0 l 0.0E0 l 4.0E-2 l 0.0E0 l 2.2E-2 l 1.2E4 l 1.3E4 l l I -135 l 0.0E0 l 0.0E0 l 0.0E0 l 2.8E-18l 0.0E0 l 1.6E-18L 2.5E3 l 1.4E4 l UN-ID l 0.0E0 l 0.0E0 0.0E0 ' 2.8E5 1 0.0E0 l 2.4E5 l 5.7E2 l 4.4E6 I I I l~ ' I 1 l l 1 I I l l 1 I I l l l l l l l 1 l l 1 l l 1 I I I I I l 1 i I I l i I I l l 1 l l l 1 I I I I I I I I I I I I l l l l l l l l l l l l 1 1 I I I I I I I I I I I I I l 1 l l l 1 l l 1 1 I I I I l i I l l I I i Inhalation Pathway, units = f ( Food & Ground Pathway, units = c APPROVED MAR 171986 2-59 Rev. 18 03-19-86

T TABLE 2-14 I DOSE PARAMETER R; FOR SECTOR G Page 3 of 3 l Pathway = Hwy Patrol Weigh Station Distance = 2.0 miles l l X/Q = 2.0E-7 sec/m' 0/Q'= 8.5E-10 m

  • l l

l Infant l Child l Teen l Adult l l l l l l l l lInhala-l Food & lInhala-l Food & lInhala-l Food & IInhala-l Food & l l Radio-l tion l Ground Ition l Ground Ition l Ground [tico l Ground l ilNuclide l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathway l Pathwayl l l l l l l l l l H -3 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.9E2 l 0.0E0 l l Cr-51 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 7.6E2 l 1.1E6 l l Mn 54 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 1.8E4 l 3.2E8 l Co-57 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 7.2E3 l 7.8E7 l Co-58 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.4E4 l 8.7E7 l l Co-60 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 6.5E4 l 4.9E9 l l Sr-89 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 6.9E4 l 4.9E3 l l Sr-90 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 l 2.3E7 1 0.0E0 l l Zr-95 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 3.4E4 l 5.7E7 l l Nb-95 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 2.4E4 1 3.1E7 i l Te-129m l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 8.3E3 l 4.5E6 l l Cs-134 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 1.9E5 l 1.6E9 l l Cs-136 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 3.3E4 1 3.4E7 l l Cs-137 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 [ 0.0E0 l 1.4E5 1 2.3E9 l l Ba-140 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 l 5.0E4 4.7E6 l i l Ce-141 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 2.7E4 3.1E6 l l Ce-144 l 0.0E0 1 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 1.9E5 l 1.6E7 l l I -131 l 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 1 2.7E6 1 3.9E6 l I -133 l 0.0E0 l 0.0E0 1 0.0E0 1 0.0E0 1 0.0E0 l 0.0E0 l 4.9E5 l 5.6E5 [ I -135 1 0.0E0 1 0.0E0 l 0.0E0 l 0.0E0 1 0.0E0 l 0.0E0 l 1.0E5 l 5.8E5 1 UN-ID l 0.0E0 ! 0.0E0 0.0E0 1 0.0E0 1,0.0E0 l 0.0E0 l 2.4E4 l 1.7E8 l l l l l 1 l l l l l l 1 1 I I l l l l l l l l 1 1 I l l l l l 1 I I l l I I l l l l l 1 l 1 l l l l I I I I I l l 1 1 I I I I I l l l l l l l l 1 l l l l 1 l l l l l l 6 l l l l I I l l l l 1 i l l l I l l l l l l 1 l 1 Inhalation Pathway, units = "C" ( Food & Ground Pathway, units =

  • ]c APPROVED

/ MAR 171986 2-60 Rev. 18 03-19-86

2.4 TOTAL DOSE CALCULATIONS (3.11.4) ( 2.4.1 Total Dose to Most Likely Member of the Public The total annual dose or total dose commitment to any member of the public, due to releases of radioactivity and to radiation, from uranium fuel cycle sources within 5 miles of the Site is calculated using the following expressions. This methodology is used to neet the dose limitations of 40 CFR 190 per twelve consecutive months. The transportation of radioactive material is excluded from the dose calculations. The Annual Total Dose is determined monthly for maximum organ (gas & liquid), whole body (gas & liquid) and thyroid (gas & liquid) to verify that the Site total ( (Units 1, 2 and 3) is less than or equal to 25 mrem, ) 25 mrem and 75 mrem respectively. .1 Annual Total Organ Dose (f0T(rgan)) 12 2/3 r-H3 n 0 (organ) = I I l D (OG) V D (OL) + D (0G) l (2-20) TOT t=1 j=1 l Jt ja Jt l; L_ _J j = Units 1, 2 and 3 1 = nonths 1 - 12"*

  • NOTE: DH (OG) = 0 for bone jt "All to be summed over the most recent 12 months.

Where: n (2-21) 0 (0G) = K I C,, RRt k; i = each isotope in W jt i=1 specific organ category K=3.1688E-2(c 2-70 APPROVED Rev. 18 MAR 171986 03-19-86

F 2.4.1 Total Dose to Most Likely Member of the Public (Continued) ( n = Number of isotopes in the specified organ category Cgg = Total particulate gas curies released for the month R N Controlling location factors from ikt k = 00CM Tables 2-4, Units 1 and 2/3 0 (0L) = Liquid organ dose for the specified organ in mrem for the je month. [ Reference ODCM Units 2/3 (1-19), Unit 1 (1-13)] D" (OG) = Gas organ dose form tritium in mrem for the month. jt (Note: H3 bone contribution = 0) .2 Annual Total Whole Body Dose (DTOT( B)) 12 2/3 r-l D (WBL) + 0"3(OG) + 0.9 0 (T) l + 0(Direct); (2-22) D (WB) = I I TOT t=1 j=1 l Jt jt je l L. _J J = Units 1, 2 and 3 1 = months 1 - 12*

  • To be summed over the most recent 12 months.

? Where: D (WBL) = Liquid whole body organ dose in mrem for the whole month. jt [ Reference ODCM Units 2/3 (1-19), Unit 1 ODCM (1-13)] D"'(0G) = Gas organ dose from tritium in mrem for the month. jt (from (2-21)) D (T) = Gamma air dose in mrad for the month. Je 0.9 converts mrad to mrem. [ Reference ODCM Units 2/3 (2-14), Unit 100CM (2-10)] c-4 l n 1 0 (Direct) = I l max [D(beach),] - I D(bkgd)g l.0342 (2-23) j=1 l i=1 I n L. _J i = for all TLDs per quarter j = for Quarters 1-4 ( APPROVED 2-71 MAR 17 B86 Rev. 18 03-19-86

2.4.1.2 Annual Total Whole Body Dose (DTOT(W8)) (Continued) (

  • Direct Radiation The direct radiation levels are evaluated most recently using cadmium covered TLDs. The TLDs are placed at 59 locations around the site. The average dose from TLDs 5 to 50 miles from the site 1s used as background. These sites are subject to change.

The background is subtracted from the highest reading beach TLD (numbers 55 through 58). This value is the direct dose but must be prorated by the beach occuoancy time of 300 hours, a factor of 0.0342. .3 Annual Total Thyroid Dose (f0T(THYROID)) ( 12 2/3 r-- 3 D (THiROID) = I I l (D (OG) + D (OL) l ; (2-24) TOT t=1 j=1 l Jt je l t _J j = Units 1, 2 and 3 t = months 1 - 12*

  • To be summed over the most*rscent 12 months.

Where: D (0G) = Thyroid organ dose from gaseous iodine for the month JE in mrem. (from 2-21) D (OL) = Liquid thyroid organ dose for the month in mrem. jt [ Reference ODCM Units 2/3 (1-19), Unit 1 ODCM (1-13)] l APPROVED 2-72 Rev. 18 03-19-86

Psg2 1 9 4 i l TABLE 2-15 ~ l PARAMETERS USED IN " PARTS" CALCULATION OF R l I Distance & IAGE 10RG land Use Crepass Sector (miles) _ GF _ZIN FV FP _ FC _FPF _FGT FPG _ FB _.FBF F Sheep

  • Comments l

1. I 2 San Onofre Surf P 0.4 0 0 0 0 0 0 0 0 0 0 ZIN = 0 hrs /yr Beach 2 2 San Onofre Surf P 0.4 0.0048 0.0104 0 0 0 0 0 0 0 0 GF 0 hrs /yr = Beach ZIN = 91 hrs /yr GF = 42 hrs /yr 3 2 San Onofre Surf P 0.4 0.0229 0.0403 0 0 0 0 0 0 0 0 Beach ZIN = 353 hrs /yr 4 2 San Onofre Surf P 0.4 0.1427 0.1427 0 0 0 0 0 0 0 0 GF = 201 hrs /yr Beach (Lifeguard) ZIN =1250 hrs /yr GF 25 hrs /wk= = 1250 hrs /yr 2. I 2 Former Nixon Estate P 2.8 0.8 1 0 0 0 0 0 0 0 0 (no garden) ZIN =8760 hrs /yr 2 2 Forlier Nixon Estate P 2.8 0.8 1 0 0 0 0 0 0 0 0 Shielding Factor GF=1-0.3X0.7=0.8 (no garden) = 0.7 Fraction of time in the building = 0.3 u 6 3 2 Former Nixon Estate P 2.8 0.8 1 0 0 0 0 0 0 0 0 a (ao garden) 4 2 Former Nixon Estate P 2.8 0.8 1 0 0 0 0 0 0 0 0 (no garden) 3. I 2 Enlisted Beach P 1.5 0 0 0 0 0 0 0 0 0 0 Campground rheck-in 2 2 Enlisted Bc...h P 1.5 0 0 0 0 0 0 0 0 0 0 Campground Check-in 3 2 Enlisted Beach P 1.5 0 0 0 0 0 0 0 0 0 0 Casparound Check-in 4 2 Enlisted Beach P 1.5 0.2283 0.2283 0 0 0 0 0 0 0 0 2tN=40 hrs /wk= Campground Check-in ~ 2000 hrs /yr APPROVED MAR 171986 2-61 Rev.18 03-19-86 s

,/n. L_AF y u, '7 ^ ^ p,. 2d9 TABL 15 -~ PARAMETERS USED IN " PARTS" CALCULATION OF R Distance & IAGE ICRG 1.and Use Compass Sector (miles) . GF _ZIN_1 FP _FG _FPF _ FCT __FPG _FB,_ FBF' F Sheep

  • Comments x

4. I 2 Ealie:S B-ach P 1.2 0 0 0 0 "0 0 0 0 0 0 ZIN = 0 hrs /yr 2 2 Enlisted Beach P 1.2 0.0048 0.0104 0 0 0 0 0 0 0 0 GF 0 hrs /yr = ZIN = 91 hrs /yr ~ ~ GF = 42 hrs /yr 3 2 Enlisted Beach P 1.2 0.0219 0.0403' O O O O O 0 0 0 ZIN = 353 hrs /yr 4 2 _ Enlisted Beach P 1.2 0.0041 0.0123 0 0 0 0 0 0 0 0 GF = 201 hrs /yr ZIN = 106 hrs /yr GF 36 hrs /yr = 5. I 2 Trestles Bch Tower P 2.0 0 0 0 0 0 0 0 0 0 0 2 2 Trestles Bch Tower P 2.0 0 0 0 0 0 0 0 0 0 0 3 2 Trestles Bch Tower P 2.0 0 0 0 0 0 3 0 0 0 0 4 2 Trestles Bch Tower P 2.0 0.1712 0.1712 0 0 0 0 0 0 0 0 ZIN=GF=1500 hrs /yr 6. I 2 San Onofre lleights W Q 1.5 0.8 1 0 0 0 0 0 0 0 0 ZIN =8760 hrs /yr 2 2 San Onofre Ileights W Q 1.%

0. 8 '

1 0 0 0 0 0 0 0 0 GF=1-0.3X0.7=0.8 3 2 San Onofre Heights W Q l.5 0.8 1 0 0 0 0 0 0 0 0 a 4 2 San Onofre lleights W Q l.5 0.8 1 0 0 0 0 0 0 0 0 a j7 I 2 St. Park Office Trailer Q 0.6 0 0 0 0 0 0 0 0 0 0 ~ 2 2 St. Park Office Trailer Q 0.6 0 0 0 0 0 0 0 0 0 0 3 2 St. Park Office Trailer Q 0.6 0 0 0 0 0 0 0 0 0 0 4 2 St. Park Office Trailer Q 0.6 0.0457 0.0457 0 0 0 0 0 0 0 0 ZIN=GF=400 hrs /yr l APPROVED 2-62 Rev.18 MAR 171986 03-19-86

.m m ^ Pcg. of 9 TABt.t 2-15 PARAMETERS USED IN " PARTS" CALCULATION OF R Distance I h IAGE 10RG land Use Compass Sector (miles) GF ZIN FV FP _ FG FPF FGT FPG FB FBF F Sheep

  • _ Comments 8.

I 1 Surf Beach Guard Shack Q 0.7 0 0 0 0 0 0 0 0 0 0 { 2 2 Surf Beach Guard Shack Q 0.7 0 0 0 0 0 0 0 0 0 0 3 2 Surf Beach Guard Shack Q 0.7 0 0 0 0 0 0 0 0 0 0 4 2 Suri deach Guard Shack Q 0.7 0.2283 0.2283 0 0 0 0 0 0 0 0 ZIN=GF=40 hrs /wk= 2000 hrs /yr 9. I 2 Enl Beach Rec Bldg. Q 1.2 0 0 0 0 0 0 0 0 0 0 2 2 Enl Beach Rec. B!dg. Q 1.2 0 0 0 0 0 0 0 0 0 0 i 3 2 En1 Beach Rec. Bldg. Q 1.2 0 0 0 0 0 0 0 0 0 0 4 2 Enl Beach Rec. Bldg. Q l.2 0.2854 0.2854 0 0 0 0 0 0 0 0 ZIN=GF= 50 hrs /wk. 2300 hrs /yr 10. I 2 $heep Heat Q 1.6 0 0 0 0 0 0 0 0 1 1 3.1E-04 2 2 Sheep Heat Q 1.6 0 0 0 0 0 0 0 0 1 1 3.lE-04 3 2 Sheep Heat Q 1.6 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 2 Sheep W at Q 1.6 0.0055 0.0055 0 0 0 0 0 0 1 1 3.1E-04 ZIN=GF=48 hrs /yr= 2 days /yr ' 11. 1 2 SC Res. W Carden Q 3.9 .8 1.0 1.0 0 0.76 0 0 0 0 0 ZIN =8760 hrs /yr 2 2 SC Res. W Carden Q 3.9 .8 1.0 1.0 0 0.76 0 0 0 0 0 GF=1-0.3X0.7=0.8 3 2 SC Res. W Garden Q 3.9 8 1.0 1.0 0 0.76 0 0 0 0 0 4 2 SC Res. W Carden Q 3.9 .R 1.0 1.0 0 0.76 0 0 0 0 0 APPROVED MAR 171986 - 2-63 3,,,3 n

  • ~

n' J

~ A LE 2-15 22 4 ef 9 PARAMETERS USED IN " PARTS" CALCULATION OF R I Distance No. IAGE 10RG 1,and Use Compass Sector (miles) GF _ ZIN FY FP FG _FPF _FGT _FPG FB FBF F Sheep

  • Comments 12.

1 2 SC Ranch (No Res) Q 2.2 0' 0 1 0 0.76 0 0 0 0 0 2 2 SC Ranch (No Res) Q 2.2 0 0 1 0 0.76 0 0 0 0 0 3 2 SC Ranch (No Res) Q 2.2 0 0 1 0 0.76 0 0 0 0 0 4 2 SC Ranch (No Res) Q 2.2 0 0 1 0 0.76 0 0 0 0 0 4 13. 1 2 50 Mobile Ikmes R 1.3 .8 1 0 0 0 0 0 0 0 0 2IN =8760 hrs /yr 2 2 SO Hr5tle Ikmes R I.3 .8 1 0 0 0 0 0 0 0 0 GF=1-0.3X0.7=0.8 3 2 50 Mobile liomes R 1.3 .8 1 0 0 0 0 0 0 0 0 4 2 50 Mobile Homes R 1.3 .8 1 0 0 0 0 0 0 0 0 14 1 2 SC Ran (No Res) R 2.3 0 0 1 0 0.76 0 0 0 0 0 2 2 SC Ran (No Res) R 2.3 0 0 1 0 0.76 0 0 0 0 0 a 3 2 SC P.an (No Res) R 2.3 0 0 1 0 0.76 0 0 0 0 0 i 4 2 SC Ran (No Res) R 2.3 0 0 1 0 0.76 0 0 0 0 0 l 15. I 2 SC Ranch Packing R 2.6 0 0 1 0 0.76 0 0 0 0 0 2 2 SC Ranch Picking R 2.6 0 0 1 0 0.76 0 0 0 0 0 3 2 SC Ranch Packing R 2.6 0 0 1 0 0.76 0 0 0 0 0 4 2 SC Ranch Packing R 2.6 .8 1 1 0 0.76 0 0 0 0 0 i ZIN =8760 hrs /yr I GF=1-0.3X0.7=0.8 i APPROVED 2-64 Rev. 18 MAR 171986 03-19-86

0 m .^. ^ tab 2-15 Page > of 9 PARAMETERS USED IN " PARTS" CALCULATION OF R Distance I Mo. IAGE IORG land Use Compass Sector (miles) . GF ZIN FV FP _ FG FPF FGT FPG FB FBF P Sheep

  • Commients

{ 16. 1 2 Sheep Heat R 0.9 0 0 0 0 0 0 0 0 1 1 3.lE-04 2 2 Sheep Meat R 0.9 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Heat R 0.9 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 2 Sheep Heat R 0.9 0.0055 0.0055 0 0 0 0 0 0 1 1 3.lE-04 ZIN=CF=48 hrs /yr= 2 days /*= 17 I 2 Camp San Mateo A 3.6 0 0 0 0 0 0 0 0 0 0 2 2 Camp San Mateo A 3.6 0 0 0 0 0 0 0 0 0 0 3 2 Cag San Mateo A 3.6 0 0 0 0 0 0 0 0 0 0 4 2 Camp San Mateo A 3.6 0.8 1 0 0 u O O O O O ZIN =8760 hrs /yr GF=1-0.3X0.7=0.8 18. I 2 Sheep Heat A 0.2 0 0 0 0 0 0 0 0 1 1 3.lE-04 6 2 2 Sheep Heat A 0.1 0 0 0 0 0 0 0 0 I 1 3.lE-04 3 2 Sheep Meat A 0.2 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 4 Sheep Heat (Shepherd) A 0.1 0.0055 0.0055 0 0 0 0 0 0 1 1 3.lE-04 ZIN=GF=48 hrs /yr= i 2 days /yr ! 19. I 2 Sheep Meat 8 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-u4 2 2 Sheep Heat B 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Meat B 0.2 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 2 Sheep Meat (Shepherd) B

0. 2 0.0055 0.0055 0 0

0 0 0 0 1 1 3.lE-04 ZIN=GF=4thrs/yr= l 2 days /yr APPROVED MAR 171986 2-65 Rev. 18 03-19-86

m 3 2-15 i . 6 ef 9 PARAMETERS USED IN " PARTS" CALCULATION OF R I Distance h 1 AGE 10RG lard Use Compass Sector (miles) _. GF ZIN FY FP FC FPF FGT rrG _ FB _ FBF F Sheep

  • Causents 20.

1 2 Sanitary Landfill B 2.1 0 0 0 0 0 0 0 0 0 0 2 2 Sanitary Landfill B 2.1 0 0 0 0 0 0 0 0 0 0 3 2 Sanitary Landfill B 2.1 0 0 0 0 0 0 0 0 0 0 4 2 Sanitary Landit11 B 2.1 0.2233 0.2283 0 0 0 0 0 0 0 0 ZIN=GF=40 hrs /wk= 2000 hrs /yr 21. I 2 Camp San Onofre C 2.6 0 0 0 0 0 0 0 0 0 0 2 2 Camp San Onofre C 2.6 0 0 0 0 0 0 0 0 0 0 3 2 Camp San Onofre C 2.6 0 0 0 0 0 0 0 0 0 0 4 2 Camp San Onofre C 2.6 0.8 1.0 0 0 0 0 0 0 0 0 ZIN =8760 hrs /yr GF=1-0.3X0.7=0.8 i 24. 1 2 Camp San Oncfre Fr. Stn C 2.3 0 0 0 0 0 0 0 0 0 0 6 2 2 Ca'p San Onofre Fr. Stn C I2.3 0 0 0 0 0 0 0 0 0 0 1 3 2 Camp San Onofre Fr. Stn C 2.3 0 0 0 0 0 0 0 0 0 0 I 4 2 Cany San Onofre Fr. Stn C 2.3 0.2854 0.2854 0 0 0 0 0 0 0 0 ZIN=GF=50 hrs /wk= 2500 hrs /yr i 23. I 2 Sheep Heat C 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-04 i Z 2 Sheep Heat C 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Heat C 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-04' 4 2 Sheep P-at (Shepherd) C

  • 0.2 0.0055 0.0055 0

0 0 0 0 0 1 1 3.1E-04 ZIN=GF=49:rs/yr= 2 days /yr APPROVED 2-66 Rev.18 MAR 171986 3-19-86

TABLt 15 Pa 7 cf 9 PARAMETERS USED IN " PARTS" CALCULATION OF R ~ i Distance No. IAGE 10RG land Use Compass Sector (miles) GF ZIN FV FF FC FPF FGT FPC FB FBF F Sheep

  • Ceaunent s 24 1

2 Sewage Facility C 2.2 0 0 0 0 0 0 0 0 0 0 2 2 Sewage Facility C 2.2 0 0 0 0 0 0 0 0 0 0 3 2 Sewage Facility C 2.2 0 0 0 0 0 0 0 0 0 0 4 2 Sewage Facility C 2.2 0.2283 0.2283 0 0 0 0 0 0 0 0 ZIN=GF=40 hrs /wk= 2000 hrs /yr 25. I 2 Cany San Onofre D 2.8 0 0 0 0 0 0 0 0 0 0 2 2 Camp San Onofre D 2.8 0 0 0 0 0 0 0 0 0 0 3 2 Camp San Onofre D 2.8 0 0 0 0 0 0 0 0 0 0 4 2 Camp San Onofre D 2.8 0.8 1.0 0 0 0 0 0 0 0 0 ZIN =8760 hrs /yr GF=1-0.3X0.7=0.8 26. I 2 Sheep Meat D 0.2 0 0 0 0 0 0, 0 0 1, 1 3.1E-04 2 2 Sheep Heat D 0.1 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Heat D 0.2 0 0 0 0 0 0 0 0 1 1 3.1E-04 4 2 Sheep Meat (Shepherd) D 0.2 0.0055 0.0055 0 0 0 0 0 0 1 1 3.1E-04 ZIN=GF=48 hrs /yr= 2 days /yr 27 1 2 Camp iknno E 4.0 0 0 0 0 0 0 0 0 0 0 2 2 Camp Horno E 4.0 0 0 0 0 0 0 0 0 0 0 3 2 Camp Horno E 4.0 0 0 0 0 0 0 0 0 0 0 4 2 Camp Horno E 4.0 0.8 1.0 0 0 0 0 0 0 0 0 ZIN =8760 hrs /yr GF-1-0.3I0.7=0.8 APPROVED 2-67 Rev.18 MAR 171986 03-19-86

m ^ TAB -15 PQ cf 9 PARAMETERS USED IN " PARTS" cal.CUI.ATION OF R I Distance h 1 AGE IGtG 1and Use Compass Sector (miles) GF _ZIN FV FP FG _FPF _FGT _FPC 1 FBF F Sheep

  • Comments 28.

1 2 Sheep Meat E 0.3 0 0 0 0 0 0 0 0 1 1 3.IE-04 2 2 Sheep Meat E 0.3 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Heat E 0.3 0 0 0 0 0 0 0 0 1 1 3.1E 04 4 2 Sheep Meat (Shepherd) E 0.3 0.0055 0.0055 0 0 0 0 0 0 1 1 3.lE-04 ZIN=GF 48 hrs /yr= 2 days /yr 29 I 2 San Onofre St. Pk Guard Shack F 0.8 0 0 0 0 0 0 0 0 0 0 2 2 San Onofre St. Pk Guard Shack F 0.8 0 0 0 0 0 0 0 0 0 0 3 2 San Onofre St. Pk Guard Shack F 0.8 0 0 0 0 0 0 0 0 0 0 4 2 San Onofre St. Pk Guard Shack F 0.8 0.2283 0.2283 0 0 0 0 0 0 0 0 ZIN=GF=40 hrs /wk= 2000 hrs /yr 30, 1 2 Sheep Heat F 0.5 ,0 0 0 0 0 0, 0 0 1 1 3.lE-04 2 2 Sheep Meat F 0.'5 0 0 0 0 0 0 0 0 1 1 3.1E-04 3 2 Sheep Meat F 0.5 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 2 Sheep Meat (Shepherd) F 0.5 0.0055 0.0055 0 0 0 0 0 0 1 1 3.lE-04 2!N=GF=48 hrs /yr= 2 days /yr 31. 1 2 San Onofre St. Beach Campand G 0.8 0.1233 0.1233 0 0 0 0 0 0 0 0 ZIN=GF= 1080 hrs /yr= 45 days /yr 2 2 San C ofre St. Beach Campand G 0.8 0.1233 0.1233 0 0 0 0 0 0 0 0 3 2 San onofre St. Beach Campgnd G 0.8 0.1233 0.1233 0 0 0 0 0 0 0 0 4 2 San Onofre St. Beach Campand G 0.8 0.1427 0.1427 0 0 0 0 0 0 0 0 ZIN=GF=25 hrs /wk= (Life Qaard) 1250 hrs /yr APPROVEI) 2-68 Rev.is i MAR 171986 a' 'a *'

v n n 3LE 2-15 Pag of 9 PARAMETERS USED IN " PARTS" CALCULATION OF R I Distance & IAGE 10RG Land Use Compass Sector (alles) GF ZIN FV FF FC _IFF _ PGT. FPG _ FB _ FBF F Sheep

  • Comunents 32.

I 2 ther Patrol weigh Sta G 2.0 0 0 0 0 0 0 G 0 0 0 2 2 16ay Patrol weigh Sta G 2.0 0 0 0 0 0 0 0 0 0 0 3 2 lby Patrol Weigh Sta G 2.0 0 0 0 0 0 0 0 0 0 0 4 2 they Patrol weigh Sta G 2.0 0.2283 0.2283 0 0 0 0 0 0 0 0 ZIN=GF=40 hrs /wk= 2000 hrs /yr 33. I 2 Sheep Heat G 2.7 0 0 0 0 0 0 0 0 I 1 3.lE 04 2 2 Sheep Meat G 2.7 0 0 0 0 0 0 0 0 1 1 3.lE-04 3 2 Sheep Heat G 2.7 0 0 0 0 0 0 0 0 1 1 3.lE-04 4 2 Sheep Meat (Shepherd) G 2.7 0.0055 0.0055 0 0 0 0 0 0 1 1 3.lE-04 ZIN=GF=48 hrs /yr= 2 days /yr MG:2472F 6 1.7 lbs.

  • F Sheep - This factor (3.1I10-4) is the product of FB-0.0192 and Isab to beef consisuption ratio of (106.4 lbs. = 0.0160).

The FB is equal to 2 weeks per year or 1/52 = 0.0192. For calculational reasons. FB must be defaulted to 1.00 and be used separately in a different colisen (F Sheep). 2-63 Rev.18 03-19-86 APPROVED MAR 171996

( Page 4 og g TABLE 5-1 (Continued) ( RADIOLOGICAL ENVIRONMENTAL MONITORING SAMPLE LOCATIONS DISTANCE

  • TYPE OF SAMPLE AND SAMPLING LOCATION (miles)

DIRECTION

  • Airborne 6

SONGS Meteorological Tower ** 'J. 3 NW 1 City of San Clemente (City Hall) 5.5 NW 9 State Beach Park ** 0.4 ESE 3 Huntington Beach Generating Station 37 NW 2 Camp San Onofre (Camp Pendleton)** 1.8 NE 11 NESA EOF 0.5 NNW 5 Units 2 and 3 Switchyard ** 0.13 ESE 10 Bluff 0.5 WNW 12 SONGS Evaporation Pond 0.4 NW Soll Samples 3 3 Basilone Road /I-5 Freeway Offramp 2.0 NW 4 Huntington Beach Generating Station 37 NW 5 East Site Boundary O.2 NNW 1 Camp San Onofre 2.5 NE 2 Old Route 101 - Southeast 3.0 SE Ocean Water D Newport Beach 30 NW A Station Discharge Outfall - Unit 1 0.5 SW 8 Outfall - Unit 2 O.7 SW C Outfall - Unit 3 0.7 SW

  • Distance (miles) and Direction (sector) are measured relative to Units 2 and 3 midpoint.

Direction is determined from degrees true north'. (

    • Not required by Technical Specifications APPROVED 5

MAR 17 B86 gf_i,jg

? TABLE 5-2 ( PIC-RADIOLOGICAL ENVIRONMENTAL MONITORING LOCATIONS-SONGS 2/3 OISTANCE* PRESSURIZED ION CHAMBERS THETA (OEGREES) METERS / MILES DIRECTION / SECTOR

  • S1 San Onofre Beach 298*

1070 0.665 WNW P S2 SONGS Evaporation Pond 313* 890 0.553 NW Q S3 Japanese Mesa 340* 1150 0.715 NNW R S4 NCB - Camp Pendleton 3* 1120 0.696 N A S5 MC8 - Camp Pendleton 19* 1050 0.653 NNE B S6 MCB - Camp Pendleton 46* 940 0.584 NE C 57 MCB - Camp Pendleton 70* 870 0.541 ENE D S8 MCB - Camp Pendleton 98* 1120 0.696 E E 59 San Onofre State Beach 121* 940 0.584 ESE F ( )

  • Distance (meters / miles) and direction (sector) are measured relative to Units 2 & 3 midpoint.

Theta direction is determined from degrees true north. (, APPROVED t1AR 1719RR 5-8 Rev. 18 03-19-86}}