ML20205C694
| ML20205C694 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 09/18/1985 |
| From: | Dixon O SOUTH CAROLINA ELECTRIC & GAS CO. |
| To: | Harold Denton Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20205C698 | List: |
| References | |
| NUDOCS 8509230157 | |
| Download: ML20205C694 (1) | |
Text
-.
I c
j s.e, l.
(
SOUTH CAROLIN A ELECTRIC & GAS COMPANY o., omc e n.
cotuwei4. soutw camoup.4 avata o w o,.o,n.
September 18, 1985 vca e.es....,
rwet.. on..no.
Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation s
U. S. Nuclear Regulatory Coussission Washington, DC 20555
Subject:
Virgil C. Summer Nuclear Station Docket No. 50/395 Operating License No. NPF-12 Steam Generator Ibbe Plugging Criteria t
Dear Mr. Denton:
In a letter dated August 30, 1985 f rom Mr. O. W. Dixon, Jr., to Mr. H. R.
Denton, South Carolina Electric and Gas Company (SCE&C) requested an amendaunt to the Virgil C. Summer Nuclear Station Technical Specifications, Section 3/4.4.5, " Steam Generators." This amendaent would allow for the repair of steam generator tubes by an NRC approved method, and would provide for specific alternative actions to tube plugging when such actions had been reviewed and approved by the NRC. As a result of discussions with the NRC Staf f, SCE&C further proposes the bases to the Technical Specifications be revised as shown in Attachment 1.
This revision would provide consistency between the bases and the Technical Specifications and accurately reflect the requirements fo nd therein.
l If ynu should have any further questions, please advise.
Very truly yours,
'j s
x O. W. D1 on, AMM/csw At tachments e
cc:
V. C. Summe r C. A. Price T. C. Nichols, Jr./0. W. Dixon, Jr.
C. L. I,lgon (NSRC)
E. H. Crews, Jr.
K. E. Nodland E. C. Roberts R. A. Stangh W. A. Willises, Jr.
C. O. Percival
(
D. A. Nauman C. W. Hehl J. Nelson Crace J. B. Knotts, Jr.
Group Managers H. G. Shealy O. S. Bradham.
NPCF Flie 5
v.,
t ogg
..