____

OPERATING DATA REPORT DICKETNO. 50-341 COMPLETED BY P. M. Anthony DATE October 15, 1988 TELEPHONE (313)586-1617 OPERATING STATUS 1.

UNIT NAME:

Fermi 2 l Notes:

l 2.

REPORTING PERIOD: September 1988 l

l 3

LICENSED THERMAL POWER (MWt):

3292 l ' To be determined l

4.

NAMEPLATE RATING (GROSS MWe):

1154 l

l 5.

DESIGN ELECT RATING (Net MWe),1093 l

l 6.

MAX DEPENDABLE CAP (GROSS MWe):

l l

7.

MAX DEPENDABLE CAP (Net NWE):

l l

8.

IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS NUMBER 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS: None 9.

POWER LEVEL TO WHICH RESTRICTED, IF ANY (HWe Net):

None

10. REASONS FOR RESTRICTION, IF ANY: Nono THIS MONTH YR TO DATE CUMULATIVE
11. HRS IN REPORTING PERIOD 720 6037 6037
12. HRS REACTOR WAS CRITICAL 0

3072.3 3072.3

13. REACTOR RESERVE SHUTDOWN HRS 0

0 0

14. HOURS GENERATOR OW-LINE 0

2850 2850

15. UNIT RESERVE SHUTDOWN HOURS 0

0 0

16. GROSS THERMAL ENERGY GEN (MWH) 0 7,214,612 7,214,112
17. GROSS ELECT ENERGY GEN (MWH) 0 2,316,048

_2,316,048

18. NET ELECT ENERGY GEN (MWH) 0 2,183,980 2,183,980
19. UNIT SERVICE FACTOR 0

' 47.2 47 2

20. UNIT AVAILABILITY FACTOR 0

47.2 47 2

21. UNIT CAP FACTOR (USING MDC NET)
22. UNIT CAP FACTOR (USING DER NET) 0 33.1 33 1
23. UNIT FORCED OUTAGE RATE 100 22.4 22.4
24. SHVTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATE, DURATION OF EACH)

None

25. IF SHUT DOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP: 10/06/88
26. UNITS IN TEST STATUS (PRIOR TO COMMERCIAL OPERATION):

FORECAST ACHIEVED INITIAL CRITICALITY N/A N/A INITIAL ELECTRICITY N/A N/A COMMERCIAL OPERATION N/A N/A h

i.ih 41 R

PDC

l

.b.

1 l

AVERACE DA1LY UIllt POWER LEftL l

i l

i DOCKET NO.

50-341 l

UNIT FERMI 2 I

l DATE October 15. 1988 COMPLETED BY P. M. Anthony l

I TELEPHONE (313) 586-1617 1

Nonth September, 1988 i

l DAY AVERAGE DAILY POWER LEVEL DAY AVERACE DAILY POWER LEVEL (NWe-Net)

(NWe-Net) 1 0

17 0

i 2

0 18 0

3 0

19 0

i 4

0 M

0

[

i 5

0 21 0

[

t 6

0 22 0

l i

7 0

23 0

t 8

0 24 0

9 0

5 0

10 0

26 "0

f 11 0

27 0

12 0

28 O_

l 13 0

29 0

[

r 14 0

30 0

l t

15 0

31 N/A 16 0

l i

t i

[

?

UNIT SHUTDOWNS AND POutO REDUCTIONS e

DOCmET NO.

50-341 DATJ Octcbee 95. 1988 UNIT NawE per=*

2 COwPLETED SW P _w.

Anthony 2

YELEPHONE (313)586-1617 REPORT WONTH 5epte=cer. 1988 1

I I

I I

I i

I l

l l

1 wtTHO3 OF l LER I Sv5 Coup I CAUSE & CORRECT!vE j

N3.

I DATE l TvpE l DUR 1 REASON I SMUTTING DOwN l NO.

CODE CODE l ACTION TO PREVENT l

l l (1) 1 (HRS)l (2)

! THE REACTOR I

(4) l (5) i RECURRENCE I

I I

I I

f (3)

I I

i I

I I

i i

i I

j 88-006 1 08/29/88 i F

1 720 l 8

I 4

108-032 !

BO

, V l LPCI Loop Select togic still inop-1 I

l

}

l l

l L

l 1 oracle cue to inability to close l

l l

l l

l l 831-70318.

Found torque settch l

l l

1 j

l l

l not prcperty reset foltostog l

l l

l l

I l

l j replacement of operator in 1984.

I i

I I

I l

I i

1 1

1 I

f I

I I

I I

I f

f I

1 I

I (1) F: FORCEO (2) REmSON:

(3) wETHOD:

(4) EXHIBIT G - INSTRUCTIONS 5: SCHEDULED A - EQUIPvtNT FAILURE (EXPLAIN) 1 - MANUAL F OR PREPARATION OF DATA 8 - MAINTENANCE OR TEST 2 - wANUAL SCRAW ENTRY SHEETS FOR LICENSEE C - REFUELING 3 - AUTOMATIC SCRAW EVENT REPORT (LER) *ILE D - REGULATOCV RESTRICTION 4 - CONTINUED (NUREG-0161)

E - OPEnATOR TRAINING & LICENSE ExAw! NATION 5 - REDUCED LOAD F - ADw!NISTRAT!vE 9 - OTHER G.- OPERATIONAL ERROR (EmpLAIN)

H - OTHER (ENPLAIN)

(5) ExHISIT 1 - SAwE SOURCE 6

--