ML20203N523

From kanterella
Jump to navigation Jump to search
Forwards SER Finding Position on Items 4.2.1 & 4.2.2 Re Reactor Trip Sys Reliability of Generic Ltr 83-28 Acceptable,Per Util 831105 & 850806 Responses
ML20203N523
Person / Time
Site: Byron  Constellation icon.png
Issue date: 04/28/1986
From: Noonan V
Office of Nuclear Reactor Regulation
To: Farrar D
COMMONWEALTH EDISON CO.
Shared Package
ML20203N525 List:
References
GL-83-28, NUDOCS 8605050467
Download: ML20203N523 (3)


Text

._

s  !

"~

APR 2 8 W Docket Nos: STN 50-454 and StN 50-455 Mr. Dennis L. Farrar Director of Nuclear I.icensing Commonwealth Edison Company P.O. Box 767 Chicago, Il 60690

Dear Mr. Farrar:

SUBJECT:

GENERIC LETTER 83-28: ITEMS 4.2.1 AND 4.2.2 By letters dated November 5, 1983 and August 6, 1985, you responded to Generic letter 83-28 Items 4.2.1 and 4.2.2 for Byron Station, Units 1 and 2. The staff, with assistance from Idaho National Engineering 1.aboratory, has reviewed your responses and found them acceptable for the subject items. The results of our review are contained in the enclosed Safety Evaluation Report, h

Vincent S. Noonan, Director PWR Project Directorate No. 5 Division of PWR licensing-B

Enclosure:

As stated cc: See next page Distribution:

Docket; Files NRC PDR^

LPDR ACRS (10)

J. Partlow H: d?Ide!

T. Novak M. Rushbrook PD#5 R/F PM:PD#5 DIR:PD#5 1.01shan:js ' W V. Noonan 4 /2 6 /86 4 /ze /86 0FFICIAL RECORD COPY 8605050467 860428 PDR ADOCK 05000454 P PDR -

, punq f Ig UNITED STATES g g NUCLEAR REGULATORY COMMISSION y 1j WASHINGTON, D. C. 20555

"%'.....*/ M 2 8 WW Docket Nos: STN 50-454 and StN 50-455 Mr. Dennis (.. Farrar Director of Nuclear t.icensing Commonwealth Edison Company

. P,0. Box 767 Chicago, II. 60690

Dear Mr. Farrar:

SUBJECT:

GENERIC l.ETTER 83-28: ITEMS 4.2.1 AND 4.2.2 By letters dated November 5, 1983 and August 6, 1985, you responded to Generic 1.etter 83-28 Items 4.2.1 and 4.2.2 for Byron Station, Units 1 and 2. The staff, with assistance from Idaho National Engineering 1.aboratory, has reviewed your responses and found them acceptable for the subject items. . The results of our review are contained the enclosed Safety Evaluation Report.

p.lua Yor Vincent S. Noonan, Director PWR Project Directorate No. 5 Division of PWR I.icensing-B

Enclosure:

As stated cc: See next page 5

'Mr. Dennis L. Farrar Byron Station 7 Commonwealth Edison Company Units 1 and 2 cc:

Mr. William Kortier Ms. Diane Chavez Atomic Power Distribution 528 Gregory Street Westinghouse Electric Corporation Rockford, Illinois 61108 Post Office Box 355 Pittsburgh, Pennsylvania 15230 Regional Administrator, Region III U. S. Nuclear Regulatory Commission Michael Miller 799 Roosevelt Road Isham, t.incoln & Beale Glen Ellyn, Illinois 60137 One First National Plaza 42nd Floor Joseph Gallo Esq.

Chicago, Illinois 60603 Isham, Lincoln & Beale Suite 1100 Mrs. Phillip B. Johnson 1150 Connecticut Avenue, N.W.

1907 Stratford lane Washington, D. C. 20036 Rockford, Illinois 61107 Douglass Cassel, Esq.

Dr. Bruce von Zellen 109 N. Dearborn Street Department of Biological Sciences Suite 1300 Northern Illinois University Chicago, Illinois 60602 DeKalb, Illinois 61107 Ms. Pat Morrison Mr. Edward R. Crass 5568 Thunderidge Drive Nuclear Safeguards & licensing Rockford, Illinois 61107 Sargent & l. undy Engineers 55 East Monroe Street Ms. Lorraine Creek Chicago, Illinois 60603 Rt. 1, Box 182 Manteno. Illinois 60950 Mr. Julian Hinds U. S. Nuclear Regulatory Commission Byron / Resident Inspectors Offices 4448 German Church Road Byron, Illinois 61010 Mr. Michael C. Parker, Chief Division of Engineering Illinois Department of Nuclear Safety 1035 Outer Park Drive Springfield, Illinois 62704