SER Accepting IST Program Requests for Relief Submitted for Third 10-yr Intervals for Pumps & Valves for Plant
ML20203E974
Person / Time
Site: Calvert Cliffs  
Issue date: 02/11/1998
From:
NRC (Affiliation Not Assigned)
To:
Shared Package
ML20203E948 List:
References
NUDOCS 9802270170
Download: ML20203E974 (9)


Text

- _ - _ _ - - _ -

i

/gh5lG Q%

1

,k UNITED STATES

)

a

.j j

NUCLEAR REGULATORY COMMISSION e

WASHINGTON, D.C. 20%Hxiot gy.

BAFETY EVALUATION BY THE OFFICE OF NUCL_ EAR REACTOR REGULATION BELATED TO THE INSERVICE TESTING PROGRAM. THIRD TEN YEAR INTERVAL BALTIMOR[LGAS AND ELECTRIC COMPANY CALVERT CLIFFS NUCLEAR POWER PLANT. UNIT NOS.1 AND 2 QOCKET NOS 50 317 AND 50 318

1.0 INTRODUCTION

The Code of Federal Regulations,10 CFR 50.55a, requires that inservice testing (IST) of certain ASME Code Class 1,2, and 3 pumps and valves are performed in accordance with Section XI of the ASME Boiler and Pressure Vessel Code (the Code) and applicable addenda, except where attematives have been authorized or relief has been requested by the licensee and granted by the Commission pursuant to Sections (a)(3)(l), (a)(3)(ii), or (f)(6)(1) of 10 CFR 50.55a. In proposing attematives or r6 questing relief, the licensee must demonstrate that: (1) the proposed alternatives provide an acceptable level of quality and safety; (2) compliance would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety, or (3) conformance is impractical for its facility. NRC guidance contained in Generic Letter (GL) 89-04,

  • Guidance on Developing Acceptable Inservice Testing Programs," provides alternatives

,o the Code requirements determined acceptable to the staff. Altematives that conform with the guidance in GL 89-04 may be implemented without additional NRC approval. When atteinatives are implemented in accordance with the relevant position in the GL, the staff has determined that relief should be granted pursuant to 10 CFR 50.55a(f)(6)(i) on the grounds that it is authorized by law, will not endanger life or property or the common defense and security, and is otherwise in the public interest. In making this determination, the staff considers the burden on the licensee that would result if the requirements were imposed.

10 CFR 50.55a authorizes the Commission to approve attematives and to grant relief from ASME Code requ,rements upon making the necessary findings. The NRC staff's findings with respect to authonzing attematives and granting or not granting the relief requested as part of the licensee's IST program are contained in this Safety Evaluation (SE).

The Calvert Cliffs IST Program is based on the requirements in the 1989 Edition of the Code,Section XI, Subsections lWP and IWV, which provide that the rules for IST of pumps and valves will meet the requirements set forth in ASME Operations and Maintenance Standards Part 6 (OM-6)," Inservice Testing of Pumps in Light Water Reactor Power Plants," and Part 10 (OM-10),

" Inservice Testing of Valves in Light Water Reactor Power Plants " The Calvert Cliffs IST program c3 vers the third ten year IST interval. The third ten year interval for Units 1 and 2 begins on January 15,1998, and ends on January 14,2008.

2.0 EVALUATION The NRC staff, with technical assistance from Brookhaven National Laboratory (BNL), has reviewed the information concerning IST program requests for relief submitted for the third 9002270170 980211 l

DR ADOCK 0S00 7

Enclosure

~

2 te'.yur nntervals for Calvert Cliu Nuclear Power Plant, Units 1 and 2, in Baltimore Gas and ElecW. Company (the licensee) letters dated April 30,1997, and October 1,1997. The staff adopts the evaluations and recommendations for granting relief or authorizing alternatives contained in the Technical Evaluation Report (TER), included as an Attachment to this SE, prepared by BNL. Attachment 1 to this SE lists each relief request ana 'he status of approval.

The test deferrals of valves, as allowed by OM 10, were also reviewed. Results of the review are provided in Section 4.0 of the TER with recommendations for further review by the licensee for specific deferrals.

For the Calvert Cliffs Units 1 and 2 IST Program, relief is granted from, or alternatives are authorized to, the testing requirements which have been determined to be impractical to perform, where an allemative provides an acceptable level of quality and safety, or where compliance would result > a hardship or unusual difficulty without a compensating increase in quality or safety. Two relief requests were denied: (1) Relief Request VR 03 was denied to use attemate test media in the testing of relief valves because the licensee proposed alternate testing was to request generic relief from all valves instead of requesting specific relief for each valve or group of valves; and (2) Relief Request VR-09 was denied because the licensee did not describe any hardship or unusual difficulty in performing the Code testing. Relief Request PR 05 was granted on an interim basis for a period of 1 year to allow the licensee to either procure new vibration instrumentation that meets the Code requirements or revise and resubmit the relief request. If the licensee intends to revise Relief Request PR 05, this should be performed within 6 months of the date of this SE in order to provide the staff time to review the request and retum it to the licensee we,I before the end of the interim period.

BNL, using the Calvert Cliffs Updated Final Safety Analysis Report, conducted a scope review for the following systems against the requirements of Section XI and the regulations: auxiliary feedwater; main steam; reactor vessel head venting; containment spray; and service water. The review revealed three items that did not appear to be in compliance with the Code requirements (see Section 5.0 of the TER). The licensee should review these items, as well as other systems that might contain similar problems, and revise their program as appropriate.

The IST program relief requests which are granted or authorized are acceptable for implementation and the action items identified in Section 6.0 of the TER should be addressed within 1 year of the date of the SE or by the end of the next refueling outage, whichever is later.

Additionally, the granting of relief is based upon the fulfillment of any commitments made by the licensee in its basis for each relief request and the attematives proposed. Program changes involving new or revised relief requests must be submitted to NRC for review. New or revised relief req asts that meet the positions stated in GL 89-04, should be submitted to the NRC but may be implemented provided the guidance in GL 89 04, Section D, is followed. Program changes that add or delete components from the IST program should also be periodically provided to the NRC.

3.0 CONCLUSION

The Calvert Cliffs IST orogram requests for relief from the Code requirements have been reviewed by the staff with the assistance of its contractor, BNL. The TER provides BNL's evaluation of these relief requests. The staff has reviewed the TER and concurs with the evaluations and recommendations for granting relief or authorizing alternatives. A summary of the relief request determinations is also presented. The authorizing of attematives or granting of relief is based upon the fulfillment of any commitments made by the licensee in its basis for each

O e

o

)

3-re'"f request and the allematives proposed. The implement 9 tion of IST program and relief requests is subject to inspection by the NRC.

For any relief granted pursuant to GL 89 04 the staff (with technical assistJnce from BNL) has reviewed the information submitted by the licensee to determine whether the proposed alternative follows the relevant posit %n in the GL. Relief requests that conform with GL 89 04 are not evaluated in the TER, though any concems identified by such reviews are discussed in Section 6.0,"lST Program i.ecommended Action items." Relief Requests VR 05, VR 07, VR 10, and VR 11 are approved pursuant to GL 89 04 as they conform to the guidance for Position 2 of.

The licensee should refer to the TER, Section 6.0, for a discussion of recommendations identified during the review. The licensee should address each recommendation in accordance with the guidance therein. The IST program relief requests are acceptable for implementation and the action items identified in Section 6.0 of the TER should be addressed within 1 year of the date of this SE or by the end of the next refueling outage, whichever is later, unless otherwise specified in the TER.

The staff concludes that the relief requests as evaluated and modified by this SE will provide reasonable assurance of the operational readitiess of the pumps and valves to perform their safety related functions. The staff has determined that granting relief pursuant to 10 CFR 50.55a (f)(6)(i) and authorizing altematives pursuant to 10 CFR 50.55a (a)(3)(l) or (a)(3)(ii) is authorized by law and will not endanger life or property, or the common defense and security and is otherwise in the public interest.

Attachments: 1. Relief Request Summary

2. Technical Evaluation Report Principal Contributor: Joseph Colaccino Date: February 11, 1998

'U 1

e

-n

o

. -Summary of Pump and Valve Relief Requests Calveit Ckffs Nuclear Pcmer Plant 52 8

b Relief TER Code Requirement Equipment Proposed Alternate Method ofTesting NRC Action Request No.

Section Identification i

PR-01 2.1.1 Part 6,15.1,5.2(c);

LPSI Pumps Verify flowrate above a minimum value Alternate approved in Measurement and quarterly,no evaluation against accordance with evaluation of reference values or ae ia'~i corrective 10CFR50.55a(aX3Xi).

flowrate quarterly actions will be mx*- Measurement and evaluation of flowrate willbe made during test performed at cold shutdowns or refueling oatages.

PR-02

??1 Part 6,15.1,5.2(c);

Steam-driven Verify flowrate above a minimum value A;temate aproved in Measurement and AFW Pumps quarterly,no evaluation against accordance with evalusion of reference values or associated corrective 10CFR50.55a(aX3Xi).

flowrate quarterly actions will be made. Meatwement and evaluation of flowrate will be made during test performed at cold shutdowns or refueling outages.

PR-03 2.2.2 Part 6,15.1,5.2(c);

Motor-driven Verify flowrate above a minimum value Altemate approved in Measurement and AFW Pumps quarterly,no evaluation against accordance with enluation of reference values or avsiatui corrective 10CFR50.55a(aX3Xi).

f;owTate quarterly actions will be made. Measurement and evaluation of flowrat.: will be made during test performed at cold shutdowns or refueling outages.

O 9

o

. -Summary of Pump and Valve Relief Requests Calvert Chffs Nuclear Power Plant NRC Action Relief TER Code Requirement Equipsicat Proposed A!: arete Method ofTesting Identification Request No.

Section PR-04 2.1.2 Part 6,15.1,5.2(c);

HPSI Pur-p Verify flowrate above a minimum value Alternate approvedin accordance with Mm-ur cat and quarterly,no evaluation against 10CFR50.55a(aX3Xi).

reference values or associated corrective l

evaluation of actions will be made. Measurement ana flowrate quarterly evsluation of flowrate willbe made during test performed at cold shutdowns or refueling ondges.

PR-05 23.1 Part 6,14.6.1.6, Charging Use currentinstrumentation with a Altorate ppwved for aninterim period ofone frequency response range from 4 Hz.

Vibration Pumps year naccordancewith instruments' 10CFR50.55a(aX3Xii).

frequency response W

l PR-06 2.1.3 Part 6,15.1,5.2w; Containnient Verify flowrate r.bove a minimum value Altarete wovedin accordance with Measuremera and Spray Pumps quarterly, no evaluation against reference vaiues or associated corrective10CFR50.55a(aX3Xi).

evaluation of actions will be madr.. Measurement and flowratequarterly evaluation of flowrate will be made during test performed at cold shutdowns or refueling o=dves.

Reqw withdrawn per PR.07 Oct.1,1997 letter from C. Cruse, BGE.

9 O

. -Summary of Pump and Valve Relief Requests Calvert Ckffs Nuclear Power Plant NRC Action l

Relief TER Code Requirement Equipment Pruposed Alternate Method ofTesting Identification

' Reqe No. > Smion Measure vibration at location specified Altemate approved in PR-08 2.4.1 Part 6,15.2,4.6.4; Saltwater accordance with Location for Pumps for centrifugal pumps and use 10CFR50.55a(aX3Xii).

centrifugal pumps' hydraulic acceptance incasurement of vibration on vertical criteria.

l line shaft pumps l

and hydraulic x xp".ance criteria Use current 'mstrumentation with a Alternate sproved in PR-09 2.4.2 Part 6,14.o.l.6, Saltwater acconfance with Vibration Cooling frequency response range from 4 IIz.

)

10CFR50.55a(aX3Xii).

instruments' Pumps frequency response range Reliefis not required to PR-10 Part 6, Table 3, Generic Use Figure 1 in Part 6, OMb-1989,that use erratato the 1989 was published as errata.

Edition ofSection XI Footnote (2),

Foahlishment of (OMa-1988, Part 6).

displacementlimits for pumps with Speeds 2600 rpm,or velocity limits for pmnps <600 syn O

O

. -Sumtrary of Pump and Valve Relief Requests Calvert CL4fs Nuclear Power Plant Relief TER Code Requirement Equipment Proposed Alternate Method of Testing NRC Action Request No.

Section Identification VR-01 3.1.1 Part 1,18.1.2.2, All Class 2 Use 1994 Addenda of OM Code.

Alternate apgoved in accordance with Test accumulator and 3 SRVs 10CFR50.55a(aX3Xi).

volume requirements VR-02 3.1.2 Part 1,18.13.4, All Class 2 Use 1995 Edition ofOM Code.

No approval required to use this Code Thermal and 3 SRVs clarification.

equilibrium VR-03 3.13 Part 1,18.1.1.1, All SRVs Test at ambient temperatures without a Reliefdenied.

8.1.2 !, and 8.13.1; -

correlation.

Use ofattemate media (fluid or temru.ture)

Request w!:hdrawn per l

VR-04 Oct.1,1997 letter from C. Cruse, BGE.

Part 10,1432, SI and CS Sample disassembly and inspection Relief Requestin accordance with Generic VR-05 Exercise frequency pump suction program.

Letter 89-04, Position 2, from RWT guidance and is check valves, therefore approved l

1(2)-St-4146 pursuant to 10 CFR l

and 4147 50.55a(fX6Xi) t

. -Summary of Pump and Valve Relief Requests Calved Cliffs Nuclear Power Plant Relief TER Code Requirement Equipment Proposed Alternate Method ofTesting NRC Action Request No.

Section Idatification Part 10,14.2.1, Si and CS Exercise valves during cold shutdown Approval not required.

VR-06 Exercise frequency shutdown conditions.

Valves are not required to achieve or maintain a cooling path safe shutdown.

manual valves,1(2)-

SI-314,319, 324,329, 432,440, 441,444, 452,453, 456, and 457 VR-07 3.2.1 Part 10,143.2, SIT discharge NIT valves each refueling. Ifcheck Relief Request in Exercise frequency check valves, valve maintenance is already planned or accordance with Generic j

1(2)-SI-215, to limit personnel exposure, valves will Letter 89-04, Position 2, 225,235,245 be sample disassembled and inspected.

guidance and is therefore approved pursuant to 10 CFR 50.55a(f)(6)(i)

VR-08 3.2.2 Part 10,143.2, SITand St NIT valves each refueling. If check Approved in accordance Exercise frequency Pumps valve maintenance is already planned or with Generic Letter 89-discharge to limit personnel exposure, valves will 04, Position 2, with check valves, be srmple disassembled and inspected.

provisions.

1(2)-SI-217, 227,237,247 e

9

. -Summary of Pump and Valve Relief Requests Calvert Cliffs Nuclear Power Plant Relief TER Code Requimment Equipment Proposed Altemate Method ofTesting NRC Action Request No.

Section Identification VR-09 3.2.3 Part 10,14.2.2.3(a),

SI shutdown Leak test the valves in accordance with Reliefdenied.

l Category Avalves, cooling PlVs, Appendix J, Option B.

which perform a 1(2)-SI-651 l

function other than and 652-containment MOV isolation, leak test frequency Par

  • 10,14.3.2, CS pump Sample disassembly and inspection Relief Request in VR-10 accordance with Generic Exercise frequency discharge to program.

Letter 89-04, Position 2, spray header check valves, guidance and is

!(2)-SI-316, therefore approved 326,330,340 pursuant to 10 CFR 50.55a (f)(6)(i)

Part 10,14.3.2, Containment Sample disassembly and inspection Relief Request in VR-11 accordance with Generic Exercise frequency sump to SI program.

Letter 89-04, Position 2, and CS pump suction check guidance and is therefore approved valves,1(2)-

SI-4148 and pursuant to 10 CFR 50.55a(f)(6)(i) 4149 i.