ML20203D470

From kanterella
Jump to navigation Jump to search
Notice of Violation from Insp on 860106-10
ML20203D470
Person / Time
Site: Crystal River Duke Energy icon.png
Issue date: 04/16/1986
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20203D468 List:
References
50-302-86-04, 50-302-86-4, NUDOCS 8604220117
Download: ML20203D470 (1)


Text

1 4

. o ENCLOSURE 1 NOTICE OF VIOLATION Florida Power Corporation Docket No. 50-302 Crystal River Unit 3 License No. DPR-72 The following violation was identified during an inspection conducted on January 6-10, 1986. The Severity Level was assigned in accordance with the NRC Enforcement Policy (10 CFR Part 2, Appendix C).

Technical Specification 6.8.1 states that written procedures shall be established, implemented and maintained covering the applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33, November, 1972.

. Appendix "A" of Regulatory Guide 1.33, November 1972 recommended procedures for combating emergencies and other significant events including reactor trip.

Contrary to the above, three examples were noted where the licensee failed to properly implement required procedures in the performance of abnormal procedure AP-580, Reactor Protection System Actuation, following the reactor trip on January 1, 1986, specifically:

a. The operators failed to depress the reactor trip push button as specified by Immediate Action 1 of AP-580.
b. The operators performed only Remedial Action 3, open MVV-24, of the four actions specified by Immediate Action 6 of AP-580.
c. The operators did not open the suction from the Borated Water Storage Tank to the running makeup pump (s) as specified by the Detailed Action to be performed under Followup Action 2 of AP-580 3 when Make-up Tank level is less than or equal to 55 inches.

This is a Severity Level IV violation (Supplement I).

Pursuant to 10 CFR 2.201, you are required to submit to this office within 30 days of the date of this Notice, a written statement or explanation in reply, including: (1) admission or denial of the alleged violation; (2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

Security or safeguards information should be submitted as an enclosure to facilitate withholding it from public disclosure as required by 10 CFR 2.790(d) or 10 CFR 73.21. .--

Date: April 16, 1986 .

8604220117 860416 PDR 0

ADOCK 05000302 PDR