ML20203C197

From kanterella
Jump to navigation Jump to search

Forwards SE Re Relief Requests Associated W/Second 10 Yr Interval Insp Program.Proposed Alternative in RR-28 Provides Acceptable Level of Quality & Safety
ML20203C197
Person / Time
Site: Vogtle  
Issue date: 12/09/1997
From: Berkow H
NRC (Affiliation Not Assigned)
To: Mccoy C
SOUTHERN NUCLEAR OPERATING CO.
Shared Package
ML20203C202 List:
References
TAC-M98977, TAC-M98978, NUDOCS 9712150253
Download: ML20203C197 (3)


Text

r Mr. C. K. McCCy Distribution:

Vice President 90 emit 19e"8 LBerry MTschiltz Southern Nuclear Operating PUBLIC DJaffe JJohnson, Rll Company, Inc.

PD ll 2 Rdg.

OGC PSkinner, Rll Post Office Box 1295 BBoger GHill(4)

Birmingham, Alabama 352011295 HBerkow ACRS THarris (e-mail to TLH3 - SE only)

SUBJECT:

RELIEF REQUESTS ASSOCIATED WITH THE SECOND 10 YEAR INTERVAL INSPECTION PROGRAM - VOGTLE ELECTRIC GENERATING PLANT, UNITS 1 AND 2 (TAC NOS. M98977 AND M98978)

Dear Mr. McCoy:

By letter dated May 29,1997, Southern Nuclear Operating Company, Inc. (SNC), submitted the Vogtle Electric Generating Plant, Units 1 and 2 (Vogtle), secor d 10 year interval inservice inspection program with associated requests for relief from certain provisions of the American Society of Mechanical Engineers (ASME) Doller and Pressure Vessel Code (ASME Code),

Section XI.

On October 24,1997, the staff issued its safety evaluation of the SNC requests for relief related to ASME Code provisions for certain pipe weld examinations, smallitem repair and replacement criteria, corrective actions for leakage at bolted connections, and insulation removal to support certain visual examinations (RR 17, RR 22, RR 25, and RR 26). The staff has also completed its review of RR 28, which requests approval for the use of ASME Code Case N 508-1 as an alternative to ASME Code provisions for snubber and pressure relief valve testing. The staff concludes that the proposed alternative in RR 28 provides an acceptable level of quality and safety, and is therefore authorized pursuant to 10 CFR 50.55a(a)(3)(i). The basis for this conclusion is described in the staff's Safety Evaluation (enclosed).

If you have any questions regarding this response to your requests, please have your representative contact David H. Jaffe at (301) 4151439.

Sincerely, ORIGINAL SIGNED BY D. LABARGE FOR:

Herbert N. Berkow, Director Project Directorate ll 2 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-424 and 50-425

\\

Enclosure:

Safety Evaluation O\\

3 cc w/ encl: See next page DOCUMENT NAME:G\\VOGTLE\\VOG98977.LT2 *See previous concurtspe OFFICE PDil 2 PDil.2/LA', h,

ON PDfl h /

NAME D JAFk L BERRY h

b:

Oh ik'f /97 11/1_3/97

/

7*

I /9 /97 DATE hESNO YES#f@)

YES NO COPY YES NO DFFICIAL RECORD COPY 971 P"2150253971209 ll1l.i.li!!Ill.!!.Ili.I,3m, qn v CBM "

  • 9F

r-pm:gk UNITE 3 STATES a

I j

,}

NUCLEAR REGULATORY COMMISSION W AsHINGToN, D.C. 3000H001

/c December 9, 1997 Mr. C. K. McCoy Vice President Southem Nuclear Operating Company, Inc.

Post Office Box 1295 Birmingham, Alabama 35201 1295 GUBJECT:

RELIEF REQUESTS ASSOCIATED WITH THE SECOND 10-YEAR INTERVAL.

INSPECTION PROGRAM - VOGTLE ELECTRIC GENERATING Pl. ANT, UNITS 1 AND 2 (TAC NOS. M98977 AND M98978)

Dear Mr. McCoy:

By letter dated May 29,1997, Southem Nuclear Operating Company, Inc. (SNC), submlited the Vogtle Electric Generating Plant, Units 1 and 2 (Vogtle), second 10 year interval inservice inspection program with associated requests for relief from certain provisions of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (ASME Code),

Section XI.

On October 24,1997, the staff issued its safety evaluation of the SNC requests for relief related to ASME Code provisions for certain pipe weld examinations, smallitem repair and replacement criteria, corrective actions for leakage at bolted connections, and insulation removal to support certain visual examinations (RR 17, RR 22, RR 25, and RR 26). The staff has also completed its review of RR 28, which requests approval for the use of ASME Code Case N 508-1 as an attemative to ASME Code provisions for snubber cr.d pressure relief valve testing. The staff concludes that the proposed attemative in RR 28 provides an acceptable level of quality and safety and is therefore authorized pursuant to 10 CFR 50.55a(a)(3)(i). The basis for this conclusion is described in the staff's Safety Evaluation (enclosed).

If you have any questions regarding this response to your requests, please have your representative contact David H. Jaffe at (301) 4151439.

Sincerely, Y

Herbert N. Berkow, Director Project Directorate 112 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-424 and 50-425

Enclosure:

Safety Evaluation ec w/ encl: See next page

Vogtle Electric Generating Plant cc:

Mr. J. A. B6iley Harold Reheis, Director Manager, Licensing Department of Natural Resources Southern Nuclear Operating 205 Butler Street, SE. Suite 1252 Company, Inc.

Atlanta, Georgia 30334 P. O. Box 1295 Birmingham, Alabama 352011295 Attorney General Law Department Mr. J. B. Beasley 132 Judicial Bui! ding General Manager, Vogtle Electric Atlanta, Georgia 30334 Generating Plant Southern Nuclear Operating Mr. R. D. Barker Company, Inc.

Program Manager P. O. Box 1600 Fossil & Nuclear Operations Waynesboro, Georgia 30830 Oglethorpe Power Corporation 2100 East Exchange Place Regional Administrator, Region ll P. O. Box 134g U. S. Nuclear Regulatory Tucker, Georgia 30085-1349 Commission Atlanta Federal Center Charles A. Patrizia, Esquire 61 Forsyth Street, SW., Suite 23T85 Paul, Hastings, Janofsky & Walker Atlanta, Georgia 30303 10th Floor 1299 Pennsylvania Avenue Office of Planning and Budget Washington, DC 20004 9500 Room 615B 270 Washington Street, SW.

Arthur H. Domby, Esquire Atlanta, Georgia 30334 Troutman Sanders NationsBank Plaza Mr. J. D. Woodard 600 Peachtree Street, NE.

Executive Vice President Suite 5200 Southern Nuclear Operating Atlanta, Georgia 30308 2216 Company, Inc.

P. O. Box 1295 Resident inspector Birmingham, Alabama 352011295 Vogtle 8805 River Road Steven M. Jackson Waynesboro, Georgia 30830 Senior Engineer - Power Supply Municipal Elf.ctri: Aothority Office of the County Commissioner of Georgia Burke County Commission 1470 Riveredge Parkway, NW.

Waynesboro, Georgia 30830 Atlanta, Georgia 30328-4684

_ ;1

_