Text
. _ _ _ _ _ - _ _.. _ _ _ _ _ _
10 -Il 51 pQ%
,y
- UNITED STATES a
j j
NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 t
[,,,,*
February 17, 1998 Mr. W. L. Goodwin Manager Regulatory Affairs Westinghouse Electric Corporation Commercial Nuclear Fuel Division
{
Drawer R Columbia, South Carolina 29250
SUBJECT:
EXTENSION OF SCHEDULE - CRITICALITY SAFETY EVALUATIONS
SUMMARY
SCRUBBER SYSTEMS - (TAC Nu. L30925)
\\
Dear Mr. Goodwin:
In accordance with your application dated January 12,1998, ana pursuant to Part 70 to Title 10 g
of the Code of Federal Regulations, Ma, rials License SNM 1107 is hereby amended to extend the Scrubber Systen' criticality safety eveluatica submit'al schedule until March 31,1998.
Accordingly, License Condition S-1 has been amended to include _the date of January 12,1998, and Safety Condition S-2 has been revised to include March 1998 as the schedule for the CSE l
summary submittal and reads as fobws:
S-2.
The Criticality Safety Evaluations (CSEs) and Cnticality Safety Analysis (CSAs) will define the criticality safety bases utilized throughout the plant and will be completed as described in Sections 6.4.1 and 6.4.2 of the license application for each step of the process. A submittal to the NRC will be made by Westinghouse which will include informFL n which the staff will review against the commitments listed in Section 6.2.3 of to ~;ense application. These submittals will not be specific commitments, but are intended as a demonstration of the adequacy of the bases of saf ty itemized in Section 6.2.3. The contents listed in oection 6.4.2 of the license application are commitments. The demonstration will show the logic used by the Columbia Fuel Fabrication Facility (CFFF) in developing the criticality safety bases. It is understood that this demonstration may change over time. The submittal will consit' of a summary of the CSE or CSA as annotated below for each system (w',ich chall include fault trees for those systems for which a CSE will be done). The adequacy of the commitments in Section 6.2.3 of the licerise application will be evaluated and a reply in the form of a letter report will be generated and sent from the staff to Wes?inghouse. The submittal by the CFFF will be provided sccording to the r
following schedule:
t
\\
UN tanks - summary of CSE -10/95 a
URRS Dissolver - summary of CSE - 10/95 Solvent Extraction - summary of CSE - TBD*
URRS Scrap Processing:
9802250056 900217 I
l - (, h..
. j, h., (.
f.
PDR ADOCK 07001151 C
PDR c
}
.w Mr. W. L. Goodwin 2
Low-Level Waste Processing System - summary of CSA - 9/96.
Mop Water System Equipment - summary of CSA - 9/96 Incinerator System - summary of CSE - 9/96 Ash Recovery System - e ummary of CSE - 9/96 Liquid Honing System - summary of CSE - 9/96 Ultrasonic Cleaning System - summary of CSE - 9/96 Shredder System - summary of CSE - 9/96 URRS Waste Treatment - summary of CSA - 11/95 e
IDR Conversion - summary of CSE - Prior to Restart o
-e ADU Conversion - summary of CSE - 4/96 -
ADU Pelleting - summary of CSE - 6/96 e
Pewder Blending - summary of CSE 1/96 Miscellaneous:
Ventilation Systems (Geometry Controlled)-
summary of CSE - 3/98" Ventilation Systems (Moderation Controlled) -
summary cf CSE - 3/98"
^
Scrubber Systems - summary of CSE - 3/98" Hoods & Containment - summary of CSA - 9/96
{
Laboratories - summary of CSA - 9/96 e
IFBA - summary of CGA - 3/96 Storage Pad - NCS is based on DOE reports K-1920 and K-1663 i
e e
Rods - summary of CSA - 3/96 Storage - summary of CSE - 4!97 e
Final Assembly - summary of CSE - 6/97 UF, Cylinder Washing - summary of CSE - 12/95
- The CFFF has performed a CSA upgrade and does nct have a specific date for schedule of this CSE at this time.
" These systems are to be coupled with the Coiumbia Plant Risk Management Program (RMP) to be done for the EPA.
k
Mr. W. L. Goodwin 3
- All other conditions of this license shall remain the same.
l Enclosed are copies of the revised Materials License SNM 1107 and the Safety Evaluation i
Report, which incluc'es the Categorical Fxclusion determination.
l Sincerely, Original signed by:
Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety
_ and Safeguards, NMSS P
Docket 70-1151 i
License
_ SNM-1107 Amendment 11
Enclosures:
- 1. Materials License SNM 1107
- 2. Safety Evaluation Report cc:
Mr. Robert A. Williams Westinghouse Electric ('omoration i
Commercial Nuclear Fus! Division Drawer R Columbia, SC 29250 Djatribution w/ encl. (Control No. 640S) (TAC L30925)[ COMPLETE]
Docket 70-1151 PUBLIC NRC Fi'e Center-Region ll WSchwink FCLB R/F FCSS R/F NMSS R/F DAyres, Ril PMDA SHO-I OFC FCLB,
FCLB M FCLB 6
FCLB
/
NAME-CdMlb Pbhea
- )l d, MAda[gk MWeber[
r DATE 01/[//98 01/l[/98 hll/98 Ojdb8-
Mr. W. L. Goodwin 3
All other conditions of this license shall remain the same.
Enclosed are copies of the revised Materials License SNM-1107 and the Safety Evaluation Report, which includes the Categorical Exclushn determination.
Sincerely, oY Michael F. Weber, Chief Licensing Branch Division of Fuel Cycle Safety and Safeguards, NMSS Docket 70-1151 License SNM-1107 Amendment 11
Enclosures:
- 1. Materials License SNM-1107
- 2. Safety Evaluation Report cc:
Mr. Robert A. Williams Westinghouse Electric Corporation Commercial Nuclear Fuel Division Drawer R Columbia, SC 29250 C