Summary of 980127 Meeting W/Duke Energy Corp Re Proposed Rev of Topical Repts.List of Attendees & DEC Slides Encl
ML20203B708
Person / Time
Site: Mcguire, Catawba, McGuire  Duke Energy icon.png
Issue date: 02/10/1998
From: Tam P
NRC (Affiliation Not Assigned)
To:
NRC (Affiliation Not Assigned)
References
TAC-MA0228, TAC-MA228, NUDOCS 9802240395
Download: ML20203B708 (29)


Text

_

=

6e-161 ed - 110 t>Y

[D

'f'l 't p

UNITED STATkS 4 - pg g

j NUCLEAR REGULATORY COMMISSION o

WASHINGTON, D.C. 20046 4001

.., +

February 10, 1998 LICENSEE:

Duke Energy Corporation FACILITIES:

Catawba Nuclear Station, Units 1 and 2 McGuire Nuclear Station, Units 1 and 2

SUBJECT:

MEETING

SUMMARY

- MEETING OF JANUARY 27,1998, REGARDING PROPOSED REVISION OF TCPICAL REPORTS (TAC NOS. MA0228 AND MA0229)

REFERENCES:

(1)

Meeting Notico by P. S. Tam, January 12,1998 (2)

Letter, M. S. Tuckman to NRC,"McGuire and Catawba Transition to Westinghouse Fuel," December 2,1997 On January 27,1998, the staff met with Duke Energy Corpora MC) personnel to discuss DEC's proposed revisions of previously approved topical repo,"

.spport Catawba and McGuire's future transition from Framatome Cogema to Westinghouse fuel. Enclosure 1 lists the meeting participants. Enclosure 2 is the collection of slides prcvided by DEC; the first slide is the meeting agenda. The slides set forth details of DEC's presentation.

DEC personnel stated that the plan is to use Westinghouse MV5H fuel starting around the year 2000, and requested NRC support by:

o completing review of Westinghouse's WRB-2M topical, completing review of DEC's topical reports, reload reports, and Updated Final Safety o

Analysis Report markups consistent with DEC's reload schedule, o

agreeing to DEC's use of Westinghouse's July 88 PAD code revision without resubmittal by DEC, and o

concurring with DEC's use of the SIMULATE 3K code.

The staff stated that, based on DEC's presentation, 'he proposed topical report revisions appear to be minor, Lnd the staff will attempt to perform the required reviews within the current resources consistent with the relative priority of other licensing actions. The staff stated that there are currently no funds budgeted for contractor support; hence, any technical review c m p p,r: m q p c od i kf n

w:.:) a bautwub u 9802240395 980210 PDR ADOCK 05000369 an sa nasaasanas as P

PDR ll ll llll l lllll ll

4

-2 February 10, 1998-beyond " minor" would still have to be performed in-house with a schedule consistent with the staff's workload. -The staff will brief NRC management about what the staff heard in the meeting.

i ORIGINAL. SIGNED BY:

Peter S. Tam, Senior Project Manager Project Directorate ll-2 Division of Reactor Projects -l/II Office of Nuclear Reactor Regulation Docket Nos. 50-369,50-370,50-413J and 50414

Enclosures:

1. List of partic; pants
2. DEC slides cc w/encis: See next page Distdbution:

liard Cooy w/all encls:

_ E-Mail w/ encl.1 only Docket File SCollins/FMiraglia DRoberts PUBLIC JZwolinski RFranovich PD ll 2 Rdg.

HBerkow MGiles OGC FRinaldi SFreeman ACRS PTam NDudley LBerry JJohnson, Rll COgle, Ril SSchaeffer, Ril To receive a copy of this document, Ind5cate in the box: "C" = Copy without cttachment/ enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE PM:PDll-2 LA:PDil-@ y SC:3.R&Bf D:PDil-A /s\\

7 m

NAME P. Tam:cn D'l___ L. Berry ifD E. V7eis's H. Berkohf DATE

'2./9 /98

/-/4(//08' I

~2 // /98

~M J/98'

/ /08

/ /97 DOCUMENT NAME: G:\\CATAWBAtCATA0228. SUM

/> OFFICIAL RECORD COPY

I 2-beyond " minor" would still have to be performed in-house with a schedule consistent with the staffs workload. The staff will brief NRC management about what the staff heard in the meeting.

p Peter S. Tam, Senior Project Manager Project Directorate 11-2 Division of Reactor Projects - 1/II Office of Nuclear Reactor Regulation Docket Nos. 50-369, 50-370, 50-413, and 50-414

Enclosures:

1. List of participants
2. DEC slides cc w/encis: See next page

McGuire Nuclear Station Catawba Nuclear Station Mr. Richard M. Fry, Director cc:

Department of Environmental, Mr. Paul R. Newton Health and Natural Resources Duke Energy Corporation, PBOSE Division of Radiation Protection 422 South Ci,urch Street 3825 Barrett Drive Charlotte, North Carolina 28242 Raleigh, North Carolina 27609-7721 County Manager of Ms. Karen E. Long Mecklenberg County Assistant Attorney General 720 East Fourth Street North Carolina Department of Charlotte, North Carolina 28202 Justice P. O. Box 629 Mr. Michael T. Cash Raleigh, North Carolina 27602 Regulatory Compliance Manager Duke Energy Corporation L. A. Keller McGuire Nuclear Site Manager-Nuclear Regulatory 12700 Hagers Ferry Road Licensing Huntersville, North Carolina 28078 Duke Energy Corporation 526 South Church Street J. Michael McGarry, Ill, Esquire Charlotte, North Carolina 28242-0001

'Winston and Strawn 1400 L Street, NW.

Regional Administrator, Region 11 ~

Washington, DC 20005 U.S. Nuclear Regulatory Commission Atlanta Federal Center Senior Resident inspector 61 Forsyth Street, S.W., Suite 23T85 clo U. S. Nuclear Regulatory Atlanta, Georgia ' 30303 Commission

.12700 Hagers Ferry Road Elaine Wathen Huntersville, North Carolina 28078 Lead REP Planner Division of Emergency Management Mr. T. Richard Puryear 116 West Jones Street Owner's Group (NCEMC)

Raleigh, North Carolina 27603-1335 Duke Energy Corporation 4800 Concord Road York, South Carolina 29745 Dr. John M Barry Mecklenberg County Department of Environmental Protection 700 N. Tryon Street Charlotte, North Carolina 28202 V

McCuire Nuclear Station Catawba Nuclear Station l

cc:

Mr,'M. S. Kitlan North Carolina Electric Membership Regulatory Compliance Manager Coiwiden Duke Energy Ceipeidden P. O. Box 27306 4800 Concord Road Raleigh, North Carolina 27611 York, South Carolina 29745.

Senior Resident inspector North Carolina Municipal Power Route 2, Box 179 N Agency Number 1 1427 Meadowwood Boulevard _

York, South Carolina 29745 P. O. Box 29513 Mr. G. R. Peterson Raleigh, North Carolina -27626-0513 Site Vee President Catawba Nuclear Station County Manager of York County

- Duke Energy Corporation York County Courtheuse 4800 Concord Road York, South Carolina 29745 York South Carolina 29745-9635 Richard P. Wilson, Esquire Mr. H. B. Barron Assistant Attomey General

-Vice President, McGuila Site South Carolina Attorney General's Duke Energy Corporation Office 12700 Hagers Ferry Road P. O. Box 11549 Huntersville, North Carolina 28078

- Columbia, South '_solina 29211 Piedmont Municipal Power Agency 121 Village Drive.

' Greer, South Carolina 29651 Saluda River Electric-P. O. Box 929 Laurens, South Carolina 29360 Max Batavia, Chief.

Bureau of Radiological Health South Carolina Department of

' Health and Environmental Control

.2600 Bull Street Columbia, South Carolina 29201 i

7 9.

Distribution for Meetina Summary-Hard copy w/all enclosures:

6 PUBLIC PD 11-2 Rdg.

OGC ACRS E-Mail w/ enclosure 1 only:

S. Collins /F. Miraglia B, Boger J. Zwolinski

- H. Berkow F. Rinaldi P. Tarn

- L. Berry C. Ogle, Ril D. Roberts R. Franovich M. Giles S. Freeman N. Dudley J. Johnson, Rll S. Schaeffer, Ril -

pwc i3 J

LIST OF P ARTICIPANTS MEETING WITH DUKE ENERGY CORPORATION JANUARY 27.1998 NAME AFFILIATION Herb Berkow NRC/NRR/ Project Directorate 11-2 Kenneth Canady Duke Energy Corporation Richcrd Clark Duke Energy Corporation Ron Gribble Duke Energy Corporation TalHuang NRC/NRR/ Reactor Systems Branch Walton Jensen NRC/NRR/ Reactor Systems Branch Lee Keller Duke Energy Corporation David LaBarge NRC/NRR/ Project Directorate ll-2 Lambros Lois NRC/NRR/ Reactor Systems Branch Chu-Yu Liang NRC/NRR/ Reactor Systems Branch Frank Orr NRC/NRR/ Reactor Systems Branch Frank Rinaldi NRC/NRR/ Project Directorate 11-2 Robert Saint Clair Duke Energy Corporation Gregg Swindlehurst Duke Energy Corporation Peter Tam NRC/NRR/ Project Directorste ll-2 Eric Weiss NRC/NRR/ Reactor Systems Branch

~..

Agenda I.

Purpose of Meeting Canady I:00-1:10 11.

McGuire & Catawba Westinghouse Fuel Transition Transition Topical Report (DPC-NE-2009)

Gribble 1:10-I:30

+

Fuel Design

+

+

Fuel Rod An:4,, sis Thermal flydraulics

+

Core Design Clark I:30-1:45

+

UFSAR Chapter 15 Swindlehurst 1:45-1:50

+

+

Summary Canady I:50-2:00

+

Discussion All 2:00-2:15 III. Oconee MkB11 Fuel Assembly Transition Update

+

MkBII Schedule Gribble 2:15-2:35

+

MkB11 Fuel Design

+

MkBII LTA Program

+

Core Design St. Clair 2:35-2:50 UFSAR Chapter 15 Topical Report Status Swindlehurst 2:50-3:20 l

+

R

+

Summary Canady 3:20-3:30 3

+

Discussion All 3:30-3:45 4

l M Duke

~

EdPower A Duke Emvgy Camp cory

e Westinghouse Fuel Transition

+ McGuire/ Catawba transition to MV5H on C2C11 (5/2000)

+ Duke will perform all non-LOCA analyses.

+ Duke will use new MV5H (Robust Fuel), similar to Wolf Creek LTAs.

M Duke EdPower A Duke Energy Company

s Mk-BW FUEL McGUlRE & CATAWBA m ano meno m eno i

m uro I amTrm nem i

as u,o i

CYCLE C [ -~.. C CLE 1e ',1 l! : CTCLEInn15 cal 001112 1 l. 2 CTCLEII'. l l'

- C vCLE ' t - + l[a 'CYCf.E15- ' "l @

w5 a

3 m

m eno m uro arm m uro se uvo asp

.igno

CtCLE 9! 1 Ii' : CTCLE to. L,1 l n: o;CYCLElt-m 15 calm i ttCLE 12.: 'll-

, CYCLE 13 4 :ll

' OCH 14 id n ] l CtCLE 13 +

y w

3 a

O 5I JuD tf & )

m 4FPO ese E rFO esD up0 att UPU tok iFPO toe tno l.rCYCLE M lh CTCLEf.e': 15 Gal ' CICLE Ite.1 l,

CTCLB 11:s ll., : CVCLE 12 " ' : l l ' n C1CLE 11J rc l l CYC.14 m

I 1

v 43o erpp 4e6 rFro m Erra aus ryyn san EFro sa6 erro M [is i CTCLE F41 l h4 CTCLE 8 'w 1 le ii: CTCLE 9 F!o-1 l i

! ; CYCLE 10 1 li'] l '

! CYCLE 1R utin : l l kH CYCLR lti p o

==

0 U

NI~ hNNNNIY!hNNhYNYIN'IOkNNNiNhNbY[kNNIi Y

NNhNENhkNYINMkNIIhNkIhNISIkNNh 1994 1993 1996 1997 1998 1999 2000 2161 2002 M Duke EdPower-A Dahr Energy Company

Supporting Topicals Topical Title Submittal SER Need Date t

1. Westinghouse WRB-2M Critical Heat Flux correlation 1/98 1/99
2. Duke Power Company Westinghouse Fuel 6/98 7/99 Transition Report, DPC-NE-2009.

Begin Cycle Design - 12/98 Fuel Delivery - 3/2000

[

t D Duke EdPower A Duke Energy Company

Outline for Duke Transition Topical

1. Introduction
2. Fuel Design
3. Core Design

+

Methods Summary

4. Fuel Rod Analysis

+

Fuel Rod ECCS Interface Fuel Rod Internal Pressure and Fuel Melt

+

Fuel Rod Stress, Strain, Flattening, Fatigue and Oxidation

+

DNB Propagation

+

5. Thermal liydraulics Plant Application Description

+

Thermal liydraulic Code and Model

+

+

Critical lieat Flux Correlations Statistical Core Design Analysis

+

6. UFSAR Chapter 15

+

Revision to DPC-NE-3000

+

Revision to DPC-NE-3001

+

Revision to DPC-NE-3002 j

Loss of Coolant Analysis

+

M Duke CdPower A Duke Energy Company

MV5H (Robust) Fuel Design Contains all IRI, reliability, and CHF margin features:

+ Zirlo, IFM, new modified V5H grid

+ Larger GT, rods on bottom, lower HD force, shorter FA

+ P+ grid, longer end plug, pre-oxidized fuel rod

+ IFBA M Duke EdPower.

A Duke Energy Company

f J

s y

d g

2 a

=

x

. {.

ei...

g 4,

g)

~

G.

t

?

o w.

annums C.3 g

q)

Er g

'e.

8 3

$ j'

,j, -

- f-l

. LL, g

e.* <E 5?

s u.,

a 5 3,~E ' i.

c.

e 2

-e 2

~

S 3S m z 3

ga

.eu.e og 3

r7.,g

.gy e

4g*5g ir g.,

yg g[g 5.

ag N

g g, g,

4 u

f,

n.

e Fuel Rod Analysis

+ Duke has a full technology transfer agreement with i

Westinghouse.

+ Duke fuel rod analysis scope will be consistent with current scope being performed for FCF fuel.

+ Duke will perform all PAD 7.0.4 analyses including fuel rod interface with ECCS analysis.

+ W has provided training in Charlotte.

+ Duke PAD analyses are now being reviewed by i

Westinghouse for consistency with licensing basis and methods. (Westinghouse letter to follow).

huk Duke EdPower

-a, ~,-,

i

Fuel Rod Analysis Cont'd

+ Duke is seeking approval for use of current Westinghouse methods.

+ New Westinghouse fuel rod methods scheduled ~ July 98.

+ As part of NRC approval of Duke transition topical (fuel rod analysis chapter), Duke will ask for NRC approval for Duke to use new W methods without a second Duke submittal.

+ Duke would write a commitment letter to use Westinghouse's approved licensing basis for the new PAD methods.

M Duke En9 Power.

A Duke Em Co=) wry

7 Fuel Rod Analysis Cont'd r

Transition Topical Fuel Rod Analysis Chapter Draft Outline

+ Fuel Rod ECCS Interface i

+ Fuel Rod Internal Pressure and Fuel Melt l

1

+ Fuel Rod Stress, Strain, Flattening, Fatigue and Oxidation

+ DNB Propagation l

l i

f M Duke EdPower.

A De Ac E=cegy Cs=epe=v l

W Transition Steady State TH Methods

+ VIPRE-01

+ BWU-Z CHF Correlation for MkBW Fuel

+ WRB-2M Correlation for MV5H (Robust) Fuel

+ Conservative Transition Core Model.

+ Existing NRC approved Duke statistical core design approach will be used (explicit propagation with VIPRE).

+ Continued use of Duke Maximum Allowable Peak (MAP curve methodology).

+ TH Chapter will be ~ identical in content to DPC-NE-2005P (Appendix D), Jan '97.

M Duke EdPower A Duke Enexy Geren, i

e W Transition Steady State TH Methods (Continued)

Transition Topical TH Chapter Draft Outline

+ Plant Application Description

+ Thermal Hydraulic Code and Model

+ Critical Heat Flux Correlations

+ Statistical Core Design Analysis

- Statepoints

- Key Parameters and Uncertainties

- DNB Statistical Design Limits

- Transition Cores M Duke EdPower A Dale Em,gy Grayw=f

a a

.a

~

Nuclear Design Changes

+ SER for DPC-1004A requires re-benchmarking for significantly different I

fuel designs than those in the database.

- Westinghouse MV5H will use Integral Burnable Absorbers (IFBA) and possibly l

WABA's also.

+ SIMLLATE-3K or ARROTrA for Rod Ejection

)

M Duke EdPower-

- r, %

- -a

a Westinghouse Fuel with IFBAs

+ Benchmarking of1FBA cycles was performed on Sequoyah 2 cycles 5-7.

+ 24 axial levels and 4 radial nodes per assembly (current model detail).

+ Developed uncertainty factors using methodology in DPC-NE-1004A for Fm, F, & F. Uncertainties are bounded by those q

z in the Topical Report.

M Duke C#Powen:.

~ c.,.,

Westinghouse Fuel with IFBAs

+ Other benchmarking included boron letdown, rod worths, and HZP ITC.

+ Conclude that current methodology and uncertainties are applicable to IFBA fuel.

i

+ Plan to implement under 50.59 and not include in the transition report.

i M Daske EdPower.

-e

~

I

Rod Ejection Analysis

+ Currently approved for 3-D physics analysis of REA using ARROTTA.

+ Desire to use SIMLLATE-3K.

- Ease of use and consistency with steady-state codes and cross section libraries

- Easier to apply conservatisms

+ SIMLLATE-3K is submitted in the Oconee Chapter 15 Analysis, DPC-NE-3005-P.

M Duke EdPower

- r, c.--

.o G

Rod Ejection Analysis

+ Transition report to include:

- Comparison of ARROTTA and S3K results.

- Typical physics results for BOC & EOC, HZP

& HFP REA.

- Bounding analysis approach similar to approved ARROTTA methodology.

M Duke EdPower.

~~

4 McGuire/ Catawba UFSAR Chapter 15 Topical Reports Affected by Westinghouse Fuel Transition DPC-NE-3000-PA (Rev.1.12/97)

" Thermal-Hydraulic Transient Analysis Methodology" RETRAN-02 plant transient simulation models VIPRE-01 transient core thermal-hydraulic models a

Minor revisions to include Westinghouse fuel assemblies and CHF technology Other minor revisions to update methods possible

McGuire/ Catawba UFSAR Chapter 15 Topical Reports Affected by Westinghouse Fuel Transition l

DPC-NE-3001-PA (Rev. O.11/91)

\\

"AfultidimensionalReactor Transients and Safety Analysis Physics Parameters Afethodology" Rod ejection, steam line break, and dropped rod methods Safety analysis physics parameters methods Rod ejection methodology revision e

Minor revisions to include Westinghouse fuel assemblies and CHF technology Other minor revisions to update methods possible l

s McGuire/ Catawba UFSAR Chapter 15 Topical Reports Affected by Westinghouse Fuel Transition DPC-NE-3002-A (Rev. 2.12/97)

"UFSAR Chapter 15 Transient Analysis kiethodology" UFSAR Ch.15 analysis methods excluding -3001 events No revisions expected e

LOCA Analyses Will be Performed by Westinnhouse l

l l

Summary:

l Westinghouse Transition t

+ NRC support of Westinghouse's WRB-2M topical review.

i

+ NRC support of Duke's topical report review schedules.

+ NRC Support of Duke's planned submittals of reload reports and FSAR markups for the first batch of each unit.

+ Duke's use of Westinghouse's July 98 PAD revision without resubmittal by Duke.

+ Duke's use of SIMULATE 3K.

M Duke EdPower.

,~.n.,c,-,

.