15 JUL M Docket Nos.:
50-445 and 50-446 Mr. William G. Counsil Executive Vice President Texas Utilities ~ Generating Company Skyway Tower,t.. B 81 400 North Olive Street Dallas, Texas 75201
Dear Mr. Counsil:
SUBJECT:
ISAP VII.b.2 RESULTS REPORT In reviewing your Results Report for CPRT ISAP VII.b.2, " Valve Disassembly", and your response of May 23, 1986 to our letter of May 15, 1986, we have determined that we will need the additional information identified in the enclosure to conclude our review.
In order for us to maintain our review schedule a response within ten days is requested.
Please contact us if you have any questions regarding this matter.
Sincerely, t
Vincent S. Noonan, Director PWR Project Directorate #5 Division of PWR I.icensing-A
Enclosure:
Request for Additional Infonnation 4
cc: See next page Distribution tDocket;F. M +
T. Westerman ACRS (10) i' M PDR A. Vietti-Cook I. Barnes I.ccal PDR C. Trammell C. Pale PD#5 R/F OEl.D
,4 T. Novak J. Partlow M. Rushbrook B. Grimes s
\\
- 5 PM:PD8 D:PD#5 I
11 :.j s AVi i-Cook VSN b
/86 7///
7/
OFFICIAL. RECORD COPY e6071so04o e60715 PDR ADOCK 0000 5
p K
b,
,k UNITED STATES
[( },3(T,g NUOLEAR REGULATORY COMMISSION
! g'
,)e:j WASHINGTON, D. C. 20555 le 5(
': syff 1
%,f. < *~
f e
I Docket Nos.:
50-445 and 50-446 l
Mr. William G. Counsil Executive Vice President Texas Utilities Generating Company Skyway Tower,I., B. 81 400 North Olive Street Dallas, Texas 75201
Dear Mr. Counsil:
SUBJECT:
ISAP VII.b.2 RESULTS REPORT In reviewing your Results Report for CPRT ISAP VII.b.2, " Valve Disassembly", and ynur response of May 23, 1986 to our letter of May 15, 1986, we have determined that we will need the additional information identified in the enclosure to conclude our review.
In order for us to maintain our review schedule a response within ten days is requested._,
Please contact us if you have any questions regarding this matter.
Sincerely,
, Director R Projec Dir torate #S Division f PWR I.fcensing-A
Enclosure:
Request for Additional Information cc: See next page l
l l
i
(_
REQUEST FOR ADDITIONAL INFORMATION With regard to the VII,b.2 Results Report, the ERC reinspection has identified two valves XSF-179 (Fuel Pool Cooling and Cleanup System Isometric SF-X-FB-0038) and 1-7046 (Chemical and Volume Control System Isometric CS-1-AB-028) for which the ASME records necessary to certify the valve bonnet have not been located.
As was stated in our previous May 15, 1985, request for additional information, if the valves at issue cannot be certified as ASME Code Valves in response to licensing canmitments, then appropriate action must be taken to establish ASME Code conformance or, alternatively, modified licensing commitments must be submitted to the staff with supporting justification.
Please also provide the impact this information has on the conclusion reached in your VII.b.2 Results Report.
e e
~
i L
W. G. Counsil Comanche Peak Steam Electric Station
':n:.: Utilities Generating Company Units 1 and 2 cc:
Nicholas S. Reynolds, Esq.
Resident Inspector / Comanche Peak Bishop,l.iberman, Cook, Steam Electric Station Purcell & Reynolds c/o U.S. Nuclear Regulatory Commission 1200 Seventeenth Street, NW P. O. Box 38 Washington, D.C.
20036 Glen Rose, Texas 76043 Robert A. Wooldridge, Esq.
Regional Administrator, Region IV Worsham, Forsythe, Sampels &
U.S. Nuclear Regulatory Comission Wooldridge 611 Ryan Plaza Drive Suite 1000
.2001 Bryan Tower, Suite 2500 Arlington, Texas 76011 Dallas, Texas 75201 lanny A. Sinkin Mr. Horner C. Schmidt Christic Institute Manager - Nuclear Services 1324 North Capitol Street Texas Utilities Generating Company Washington, D.C.
20002 Skyway Tower 400 North Olive Street, l.B. 81 Ms. Billie Pirner Garde Dallas, Texas 75201 Citizens Clinic Director Government Accountability Project Mr. Robert E. Ballard, Jr.
1555 Connecticut Avenue, N.W.
Director of Projects Suite 202 Gibbs and Hill, Inc.
Washington, D.C.
20009 11 Pen Plaza New York, New York 10001 David R. Pigott, Esq.
Orrick, Herrington & Sutcliffe 600 Montgomery Street Mr. R. S. Howard San Francisco, California 94111 Westinghouse Electric Corporation P. O. Box 355 Anthony Z. Roisman, Esq.
Pittsburgh, Pennsylvania 15230 Trial lawyers for Public Justice 2000 P. Street, NW i
Renea Hicks, Esq.
Suite 611 Assistant Attorney General Washington, D.C.
20036 Environmental Protection Division P. O. Box 12548, Capitol Station Nancy E. Wiegers Austin, Texas 78711 Spiegel & McDiarmed 1350 New York Avenue, NW Mrs. Juanita Ellis, President Washington, D.C.
20005-4798 Citizens Association for Sound Energy 1426 South Polk Roy P. I.essy, Jr.
Dallas, Texas 75224 Morgan, Lewis & Bockius 1800 M. Street, NW Ms. Nancy H. Williams Suite 700, North Tower CYGNA Washington, D.C.
20036 101 California Street San Francisco, California 94111 2
--.--.e..--
-~
k Texas Utilities Electric Company Comanche Peak Electric Station Units 1 and 2 cc:
Resident Inspector - Comanche Peak l
c/o U.S. Nuclear Regulatory Comission l
P. O. Box 1029 l
Granbury, Texas 76048 Mr. John W. Beck Vice President Texas Utilities Generating Company Skyway Tower 400 N. Olive Street, LBf81 Dallas, Texas 75201 Mr. Jack Redding Licensing Texas Utilities Generating Company 4901 Fainnont Avenue Bethesda. Maryland 20814 William A. Burchette, Esq.
Counsel for Tex-la Electric Cooperative of Texas Peron, Burchette, Ruckert & Rothwell Suite 700 1025 Thomas Jefferson Street, NW Washington, D.C.
20007 GDS Associates Inc.
2525 Cumberland Parkway Suite 450 Atlanta, Georgia 30339 Administrative Judge Peter Bloch U.S. Nuclear Regulatory Commission Washington, D.C.
20555 Elizabeth B. Johnson Administrative Judge Oak Ridge National I.aboratory P. O. Box X, Building 3500 Oak Ridge, Tennessee 37830 Dr. Kenneth A. McCollom 1107 West Knapp Stillwater, Oklahoma 74075 Dr. Walter H. Jordan 881 Outer Drive Oak Ridge, Tennessee 37830