Exhibit B Prairie Island Nuclear Generating Plant License Amendment Request Dated February 10,1998 Proposed Changes Marked Up On Existing Technical Specification Pages Exhibit B consists of an existing Technical Specification page with the proposed changes highlighted on that page (shaded material to be added, strike-through material to be removed). The page affected by this License Amendment Request is listed below-Table TS.1-1 2
1
TABLE TS.1 1 Rr" 111 9/10/9^
TABLE TS.1-1 QEEEATIONAL MODES REACTOR
% RATED AVERAGE VESSEL llEAD REACTIVITY THERMAL COOLANT CLOSURE BOLTS
[ LODE TITLE CONDITION POWER,_ TEMPERAT_URE FULLY TENSIONED Q
t.
1 POWER OPERATION Critical
> 2%
NA
-YES 2
'110T STANDBY **
Critical 5 2%
NA YES 3
il0T SHUTDOWN **
Suberitical NA h 350*F YES 4
INTERMEDIATE Suberitical NA
< 350'F YES SHUTDOWN **
a 200*F 5
COLD SHUTDOWN Suberitical NA
< 200*F YES 6
REFUELING
.NA*
NA NA NO Boron concentration of the reactor coolant system and the refueling cavity sufficient to ensure that the more restrictive of the following conditions is met:
- a. K.rc $ 0.95, or
-b. Boron concentration 2 2000 ppm?**.
- Prairie Island specific MODE title, not consistent with Standard Technical Specificat. ion MODE titles. MODE numbers are consistent with Standard Technical Specification MODE numbers.
'***Thsle s3 to rTeii61sh tTays teidib 6 r o nTc oiice ht rat tonlishalElisq?1900? ppm 1fo r'1
- d199EAjMODE}.6j operaeioniduring;thsiUnitij2kfor.ce' iputage;whicin; began}gniJanua d
L t
4 l
n
Exhibit C Prairie Island Nuclear Generating Plant
)
License Amendment Request Dated February 10,1998
)
Revised Technical Specification Pages Exhibit C consists of a revised page for the Prrarie Island Technical Specifications with the proposed changes incorporated, The revised page is listed below:
Table TS.1-1 P
TAB',E TS.1 -1 p
s TABLE TS.1-1 OPERATIONAL MODES REACTOR
% RATED 0.VEAACE VESSEL HEAD REACTIVITY THERMAL COOLANT CLOSURE BOLTS HQDE TITLE CONDITION POWER TEMPERATURE EpLLY TENSIONED 1
POWER OPERATION Critical
> 2%
NA YES 2
HOT STANDBY **
Critical 5 2%
NA YES 3
HOT SHUTDOWN **
Suberitical NA h 350'F YES 4
INTERMEDIATE Suberitical NA
< 350*F YES SHUTDOWN **
h 200*F 5
COLD SHUTDOWN
.Suberitical NA
< 200'F YES 6
REFUELINC NA*
NA NA NO
+
Boron concentration of the reactor coolant system and the refueling cavity sufficient to ensure that the more restrictive of the following conditions is met:
- a. K rr s 0.95, or e
- b. Boron concentration 2 2000 ppm ***.
l
- Prairie Isiand specific MODE title, not consistent with Standard Technical Specification MODE titles. MODE numbers are consistent with Standard Technical Specification MODE numbers.
- The reactor coolant system boron concentration shall be 2 1900 ppm for MODE 6 operation during the Unit 2 forced outage which began on January 24, 1998.
I i