Certificate of Compliance 6294,Rev 0,for Model UNC-2901
ML20198G805
Person / Time
Site: 07000364, 07106294
Issue date: 02/06/1975
From: Macdonald C
NRC
To:
Shared Package
ML20198G802 List:
References
NUDOCS 8601110365
Download: ML20198G805 (3)


Text

[1 US. ATOMIC ENERGY CO\\tu:S

,.,gge m

',3 3

\\

CERTIFICATE OF CCMPL!A 2

y

/ AF he S M g For R.sj.coClive Materials Packam Is. Cerfif.cate Nuero er 1b Rev sinn tao.

Ic. Pacnage ident r.rae.na No.

6294 0

USA /6294/ AF Id, Pa.ia No.

te rot 3e aso, pays 3

2. PRE AM3LE 22.

Th.s corte# rate s issueo to satisfy Sections t 70 ;9',4.173 034,173.305..iN t 73 096 af tie Department of Tra,soortat.rsa rie ardous Mataria.s.-4 mu at ons (49 CFR 3 70-::13 ervt i a CF tt 103) ir o Sect ons 146-19-104 vo 146-13-100 of tne Ceaarrowne at Tramoo Dangerous Car,ces Ragulations (46 CF a 1JG i191, as amentfed.

2*a.

The rauaq.cy erd 'ontents descr.bco n etem 5 te cw. n*=rs tne safety standards ser orrn in Subcart C of Tat e 10, C,:ce af Feceral Raquiat ons. Art 71,"Packagerg of slad.oactiw Ntarer 46 f or Transport ard Trvse;or atun of Rad.oactive Materia: ur cer carta.n Co nait >on s:

2c.

T%is cartil are cces tot rei eve the consianor rrom comoi.ance with any raquiretnint of the r=gulations of the U.S. Decartrmnt of Trans;;or at on or other acoi.cabie ragu:4torv vncies. incluriang the goernrmnt of say country through or into wwn.cn t. e ::aca x;e weil her transcorted.

3. This certificate.s su.vo on it e oasis of a safety an46vses ecort of the package design or 2;:o..cct on-(1) Prepared by IName arwl aldress):

(2) Title and identification of recort or 4;; plication:

Combustion Engineering, Inc.

United Nuclear Corporation application dated Route 21-A April 10, 1970, as supplemented.

Hematite,flissouri 63047 (3) Docket flo. 71-6294

4. CO*.D!TIONS Th.s certificate is cor d.Oonal upon the fulf.lling of tN= requirements of Subpar D of to CFR 71, as applicab:e,and the cor.ditions specified in :::m 5 below,
5. Devription of P tekaging ar d Authorized Cor tents. Model Numoer, Fusile Class, Other Condit ons, ar a Heterences:

(a) Packaging (1) flodel flumber: UtlC-2901 (2)

Description A maximum 10.80-inch square by 30-inch long inner container constructed of minimum 14-gage steel, with bolted and gasketed top flange closure and sealed welded bottom sheet.

Inner container is centered and supported in a 22.5-inch ID by 34-inch high 18-gage steel drum with 16-gage head and D0T Specification 17H closure by asbestos sheets plywood, hardboard, and insulating material.

(3) Drawing The Model flo. UNC-2901 container is constructed in accordance with United fluclear Corporation Drawing No. D-5007-8086, Rev. 2 c

9601110365 750206 PDR ADOCK 07000364 C

PDR

}

(}

Page 2 - Certificate flo. 6294 - Revision flo. 0 - Docket flo. 71-6294 5.

(b)

Contents (1) Type and form of material Uranium dioxide as powder or sintered pellets.

Uranium may be enriched to a maximum 4.1 w/o in the U-235 isotope. The maximum H/U atomic ratio, considering all sources of hydrogenous material within the inner container for power or within the boundry of the pellet array for pellet packages, shall not exceed 4.5.

l (2) Maximum quantity of material per package l

l (i) 427 pounds and 4.81 kgs U-235 as sintered pellets enriched to a maximum 3.75 w/o in the U-235 isotope, or 3.94 kgs U-235 as sintered pellets enriched to a maximum 4.1 w/o in the U-235 isotope.

Pellets shall be packaged in accordance with United fluclear Corporation Drawing flo. D-5008-8192, Rev. 4.

(ii) 230 pounds and 3.61 kgs U-235 as powder or sintered pellets packaged in accordance with l

United fluclear Corporation Drawing flo.

A-5007-2001.

(c)

Fissile Class II and III (1) flinimum transport index to be shown on label for Class II 2.0 (2) Maximun number of packages per shipment for Class III 50 6.

The package authorized by this Certificate of Conpliance is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

7.

Expiration date:

February 28, 1980. '

l i

c h

6 1

o o

L Page 3 - Certificate flo. 6294 - Revision flo. 0 - Docket flo. 7l-6294 REFERErlCES United fluclear Corporation application dated April 10, 1970, requesting approval to deliver special nuclear material to a carrier for transport in the UNC-2901 package.

Supplements dated April 24, July 7, December 11, 1970; and April 15, 1971.

Combustion Engineering, Inc., application dated February 5,1975.

FOR THE U.S. NUCLEAR REGULATORY C0ffi!SSION M [b Charles E. !!acDonald, Chief Transportation Branch Division of !!aterials and l

Fuel Cycle Facility Licensing Date Febrtiary 6. 1975 I